• Title/Summary/Keyword: 본 인증

Search Result 6,146, Processing Time 0.031 seconds

Analysis and Improvement Strategies for Korea's Cyber Security Systems Regulations and Policies

  • Park, Dong-Kyun;Cho, Sung-Je;Soung, Jea-Hyen
    • Korean Security Journal
    • /
    • no.18
    • /
    • pp.169-190
    • /
    • 2009
  • Today, the rapid advance of scientific technologies has brought about fundamental changes to the types and levels of terrorism while the war against the world more than one thousand small and big terrorists and crime organizations has already begun. A method highly likely to be employed by terrorist groups that are using 21st Century state of the art technology is cyber terrorism. In many instances, things that you could only imagine in reality could be made possible in the cyber space. An easy example would be to randomly alter a letter in the blood type of a terrorism subject in the health care data system, which could inflict harm to subjects and impact the overturning of the opponent's system or regime. The CIH Virus Crisis which occurred on April 26, 1999 had significant implications in various aspects. A virus program made of just a few lines by Taiwanese college students without any specific objective ended up spreading widely throughout the Internet, causing damage to 30,000 PCs in Korea and over 2 billion won in monetary damages in repairs and data recovery. Despite of such risks of cyber terrorism, a great number of Korean sites are employing loose security measures. In fact, there are many cases where a company with millions of subscribers has very slackened security systems. A nationwide preparation for cyber terrorism is called for. In this context, this research will analyze the current status of Korea's cyber security systems and its laws from a policy perspective, and move on to propose improvement strategies. This research suggests the following solutions. First, the National Cyber Security Management Act should be passed to have its effectiveness as the national cyber security management regulation. With the Act's establishment, a more efficient and proactive response to cyber security management will be made possible within a nationwide cyber security framework, and define its relationship with other related laws. The newly passed National Cyber Security Management Act will eliminate inefficiencies that are caused by functional redundancies dispersed across individual sectors in current legislation. Second, to ensure efficient nationwide cyber security management, national cyber security standards and models should be proposed; while at the same time a national cyber security management organizational structure should be established to implement national cyber security policies at each government-agencies and social-components. The National Cyber Security Center must serve as the comprehensive collection, analysis and processing point for national cyber crisis related information, oversee each government agency, and build collaborative relations with the private sector. Also, national and comprehensive response system in which both the private and public sectors participate should be set up, for advance detection and prevention of cyber crisis risks and for a consolidated and timely response using national resources in times of crisis.

  • PDF

Home Meal Replacement Consumption Status and Product Development Needs according to Dietary Lifestyle of Hong Kong Consumers (홍콩 소비자의 식생활 라이프스타일에 따른 HMR 소비실태와 제품개발 요구도)

  • Paik, Eun-Jin;Lee, Hyun-Jun;Hong, Wan-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.7
    • /
    • pp.876-885
    • /
    • 2017
  • This study aimed to identify the characteristics of Home Meal Replacement (HMR) product purchases and the need for HMR product development for Hong Kong consumers in order to suggest market segmentation strategies according to consumers' dietary lifestyle. For this, an online survey was conducted on a panel of 521 Hong Kong consumers with HMR purchase experience registered at a specialized organization. Data analysis was performed using SPSS (ver. 23.0). HMR purchase characteristics of Hong Kong consumers according to dietary lifestyle showed significant differences in all items, including 'number of purchases', 'purchase location', 'cost of single purchase', and 'reason for purchase'. According to dietary lifestyle, participants were divided into three clusters: 'High interest', 'normal interest', and 'low interest'. In the case of 'high interest in dietary life group', 'low-sodium food' was the most common, followed by 'heating food', 'low sugar food', and 'low calorie food'. In the case of 'moderate interest in dietary life group', 'low-sodium food' was the most common, followed by 'low sugar food', 'low calorie food', and 'nutritious meal'. In the case of 'low interest in dietary life group', 'low sugar food' was the most common, followed by 'low-sodium food', 'various new menu', and 'easy-to-carry dehydrated food'. For the 'high interest' group, the highest proportion of consumers were male in between the ages of 20 to 29, married, and worked in an office job. The 'high interest' consumers also showed a tendency to pay '15,000 to 20,000 KRW' per single purchase. The 'normal interest' group consisted of an even proportion of male and female consumers, with the most common age range being from 30 to 39 years, and most were married. These consumers preferred to spend 'less than 10,000 KRW' or '10,000 KRW to 15,000 KRW' per single purchase, which is in the lower price range for HMR purchases. The 'low interest in dietary life group' had more females gender-wise, were unmarried, and worked in an office job, For a single purchase, the 'low interest' group chose to pay less than 10,000 KRW, which is relatively lower than the other two clusters. The results of this study can be used as baseline data for building marketing strategies for HMR product development. It can also provide basic data and directions for new HMR export products that reflect consumer needs in order to create a market segmentation strategy for industrial applications.

Assessment of Demand and Use of Fresh-Cut Produce in School Foodservice and Restaurant Industries (학교급식 및 외식업체에서의 신선편이 농산물 사용실태 및 요구도 평가)

  • Sun, Shih-Hui;Kim, Ju-Hee;Kim, Su-Jin;Park, Hye-Young;Kim, Gi-Chang;Kim, Haeng-Ran;Yoon, Ki-Sun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.6
    • /
    • pp.909-919
    • /
    • 2010
  • The purpose of this study was to investigate the demand and use of fresh-cut produce in school foodservice and restaurant industries. The subjects of this survey study were 200 school nutritionists and 70 cooks or managers in the restaurant industry nationwide. The data were collected by means of self-administered or e-mail questionnaires. Data analysis was completed using the SPSS window (ver. 12.0) program including frequency, $\chi^2$-test and t-test. Survey questions assessed the general characteristic of respondents, and the supply, use, and demand of fresh-cut produce in school foodservice and restaurant industries. Over 74% of the subjects have used fresh-cut produce. Most of the school foodservice (84.0%) kept fresh-cut produce for one day, while restaurant industry (28.3%) kept them up to three days. The nutritionists of school foodservice and managers of restaurant industry considered origin and date of production as the most important factor, respectively, when fresh-cut produce were being used. Fresh-cut root vegetable, such as potato and carrot was used mostly. The main reason not to use the fresh cut produce was due to the distrust of the fresh-cut produce safety in school foodservice and cost in restaurant industry. The main problem in fresh-cut produce use was the need of rewashing (29.9%) in school foodservice and irregular size (39.0%) in restaurant industry. These results indicate that the quality standard and size specification must be prepared with production guideline of safe fresh-cut produce.

Contents of Heavy Metals in Marine Invertebrates from the Korean Coast (한국 연안산 해산 무척추동물의 중금속 함량)

  • Mok, Jong-Soo;Lee, Ka-Jeong;Shim, Kil-Bo;Lee, Tae-Seek;Song, Ki-Cheol;Kim, Ji-Hoe
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.6
    • /
    • pp.894-901
    • /
    • 2010
  • To measure the heavy metal contents of marine invertebrates, we collected 239 individuals representing 52 species from the eastern (Pohang), western (Gunsan), and southern (Tongyeong) coasts of Korea: 34 species of molluscan shellfish (Gastropoda and Bivalvia), 6 species of Cephalopoda, 8 species of Crustacea, and 4 other species. The mean levels of the heavy metals in the samples taken from the edible portion of each Gastropoda were high in the order of Zn ($21.471\;{\mu}g/g$), Cu ($4.115\;{\mu}g/g$), Mn ($0.868\;{\mu}g/g$), Ni ($0.254\;{\mu}g/g$), Pb ($0.238\;{\mu}g/g$), Cd ($0.154\;{\mu}g/g$), and Cr ($0.110\;{\mu}g/g$). The heavy metals in the Bivalvia were high in the order of Zn ($35.655\;{\mu}g/g$), Mn ($5.500\;{\mu}g/g$), Cu ($3.129\;{\mu}g/g$), Cd ($0.423\;{\mu}g/g$), Ni ($0.402\;{\mu}g/g$), Cr ($0.233\;{\mu}g/g$), and Pb ($0.232\;{\mu}g/g$). The heavy metals in the Cephalopoda were high in the order of Zn ($18.380\;{\mu}g/g$), Cu ($3.594\;{\mu}g/g$), Mn ($0.630\;{\mu}g/g$), Cr ($0.150\;{\mu}g/g$), Pb ($0.068\;{\mu}g/g$), Cd ($0.034\;{\mu}g/g$), and Ni ($0.030\;{\mu}g/g$). The heavy metals in the Crustacea were high in the order of Zn ($25.333\;{\mu}g$/g), Cu ($9.042\;{\mu}g/g$), Mn ($0.659\;{\mu}g/g$), Cr ($0.592\;{\mu}g/g$), Cd ($0.207\;{\mu}g/g$), Pb ($0.126\;{\mu}g/g$), and Ni ($0.094\;{\mu}g/g$). Therefore, the mean levels of the harmful heavy metals (Cd and Pb) in marine invertebrates were high in the order of Bivalvia>Crustacea=Gastropoda>Cephalopoda. The average daily intakes of the heavy metals from the fisheries products were as follows: Cd ($6.88\;{\mu}g$), Cr ($19.13\;{\mu}g$), Cu ($137.02\;{\mu}g$), Mn ($156.13\;{\mu}g$), Ni ($11.39\;{\mu}g$), Pb ($7.01\;{\mu}g$) and Zn ($1,025.94\;{\mu}g$). The average weekly intakes of Cd, Cu, Pb and Zn from the fisheries products were 11.47%, 0.46%, 3.27% and 1.71% respectively, as compared with PTWI (Provisional Tolerable Weekly Intakes) established by FAO/WHO Expert Committee for Food Safety Evaluation.

Application of Westgard Multi-Rules for Improving Nuclear Medicine Blood Test Quality Control (핵의학 검체검사 정도관리의 개선을 위한 Westgard Multi-Rules의 적용)

  • Jung, Heung-Soo;Bae, Jin-Soo;Shin, Yong-Hwan;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.115-118
    • /
    • 2012
  • Purpose: The Levey-Jennings chart controlled measurement values that deviated from the tolerance value (mean ${\pm}2SD$ or ${\pm}3SD$). On the other hand, the upgraded Westgard Multi-Rules are actively recommended as a more efficient, specialized form of hospital certification in relation to Internal Quality Control. To apply Westgard Multi-Rules in quality control, credible quality control substance and target value are required. However, as physical examinations commonly use quality control substances provided within the test kit, there are many difficulties presented in the calculation of target value in relation to frequent changes in concentration value and insufficient credibility of quality control substance. This study attempts to improve the professionalism and credibility of quality control by applying Westgard Multi-Rules and calculating credible target value by using a commercialized quality control substance. Materials and Methods : This study used Immunoassay Plus Control Level 1, 2, 3 of Company B as the quality control substance of Total T3, which is the thyroid test implemented at the relevant hospital. Target value was established as the mean value of 295 cases collected for 1 month, excluding values that deviated from ${\pm}2SD$. The hospital quality control calculation program was used to enter target value. 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T of Westgard Multi-Rules were applied in the Total T3 experiment, which was conducted 194 times for 20 days in August. Based on the applied rules, this study classified data into random error and systemic error for analysis. Results: Quality control substances 1, 2, and 3 were each established as 84.2 ng/$dl$, 156.7 ng/$dl$, 242.4 ng/$dl$ for target values of Total T3, with the standard deviation established as 11.22 ng/$dl$, 14.52 ng/$dl$, 14.52 ng/$dl$ respectively. According to error type analysis achieved after applying Westgard Multi-Rules based on established target values, the following results were obtained for Random error, 12s was analyzed 48 times, 13s was analyzed 13 times, R4s was analyzed 6 times, for Systemic error, 22s was analyzed 10 times, 41s was analyzed 11 times, 2 of 32s was analyzed 17 times, $10\bar{x}$ was analyzed 10 times, and 7T was not applied. For uncontrollable Random error types, the entire experimental process was rechecked and greater emphasis was placed on re-testing. For controllable Systemic error types, this study searched the cause of error, recorded the relevant cause in the action form and reported the information to the Internal Quality Control committee if necessary. Conclusions : This study applied Westgard Multi-Rules by using commercialized substance as quality control substance and establishing target values. In result, precise analysis of Random error and Systemic error was achieved through the analysis of 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T rules. Furthermore, ideal quality control was achieved through analysis conducted on all data presented within the range of ${\pm}3SD$. In this regard, it can be said that the quality control method formed based on the systematic application of Westgard Multi-Rules is more effective than the Levey-Jennings chart and can maximize error detection.

  • PDF

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.