• Title/Summary/Keyword: 본드 수

Search Result 62, Processing Time 0.022 seconds

Basic Analysis of Bubble Behavior in the Viscous Flow Domain with the Free Interface (자유표면을 가지는 점성 유동장내의 기포거동에 관한 기초해석)

  • I.R. Park;H.H. Chun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.39 no.1
    • /
    • pp.16-27
    • /
    • 2002
  • A level-set method is used for analyzing the behaviors of gas bubbles in two fluids incompressible viscous flow domain. The governing equations are solved by using a finite volume method. The numerical results are verified by comparing with the experimental and other computational results. Computations for the deformations and motions of one or multi-bubbles in the flow domain with the initial undisturbed free interface are conducted. It can be seen that numerical results for different surface tension and density ratio arise very different behaviors of bubbles. When bubbles rise near the free interface, the free interface gives some great influence on the behaviors of bubbles. The present results computed by a level-set method give useful information about the properties of bubble motions and deformations.

Anomaly Detection Using Visualization-based Network Forensics (비정상행위 탐지를 위한 시각화 기반 네트워크 포렌식)

  • Jo, Woo-yeon;Kim, Myung-jong;Park, Keun-ho;Hong, Man-pyo;Kwak, Jin;Shon, Taeshik
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.1
    • /
    • pp.25-38
    • /
    • 2017
  • Many security threats are occurring around the world due to the characteristics of industrial control systems that can cause serious damage in the event of a security incident including major national infrastructure. Therefore, the industrial control system network traffic should be analyzed so that it can identify the attack in advance or perform incident response after the accident. In this paper, we research the visualization technique as network forensics to enable reasonable suspicion of all possible attacks on DNP3 control system protocol, and define normal action based rules and derive visualization requirements. As a result, we developed a visualization tool that can detect sudden network traffic changes such as DDoS and attacks that contain anormal behavior from captured packet files on industrial control system network. The suspicious behavior in the industrial control system network can be found using visualization tool with Digital Bond packet.

Analysis of demonstration research on solar heat pump system for room and hot water heating in the southern part of South Korea (남부지역의 태양열이용 열펌프식 온수.난방시스템의 실증연구 분석)

  • Sun, Kyung Ho;Kim, Ki Sun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.198.1-198.1
    • /
    • 2010
  • The goal of this study is to measure and compare the performance of solar heat pump for room and hot water heating. To accomplish the goal, solar heat pump with alumium roll bond type evaporator and indoor heat exchanger(condenser) was built and fully instrumented with thermocouples and pressure transducers etc. The test results showed that the COP(coefficient of performance) of HFC-134a($CF_3CH_2F$) were higher than those of CFC-12($CF_2Cl_2$). One "stratospherically safe" new refrigerant is 1,1,1,2-tetrafluoroethane(HFC-134a), which is thermodynamically similar to CFC-12 and considered to be a potential direct replacement for CFC-12 in air-conditioning and refrigeration applications. The solar heat pump system for room heating was designed to show the best efficiency that the room temperature make $18{\sim}20^{\circ}C$ and $23{\sim}25^{\circ}C$ in the southern part of South Korea during November, December, and January.

  • PDF

RF Interconnection Technique of MMIC Microwave Switch Matrix for 60 dB On-to-off Isolation (60 dB 온-오프 격리도를 위한 통신 위성 중계기용 MMIC MSM의 RF 결합 방법)

  • Noh Youn-Sub;Jang Dong-Pil;Yom In-Bok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.2 s.105
    • /
    • pp.134-138
    • /
    • 2006
  • The isolation performance of the S-band single-pole single-throw(SPST) monolithic microwave integrated circuit (MMIC) switch with two different RF-interconnection approaches, microstrip and grounded coplanar waveguide(GCPW) lines, are investigated. On-to-off isolation is improved by 5.8 dB with the GCPW design compared with the microstrip design and additional improvement of 6.9 dB is obtained with the coplanar wire-bond interconnection(CWBI) at a 3.4 GHz. The measured insertion loss and third-order inter-modulation distortion(IMD3) are less than 1.94 dB over $3.2{\sim}3.6\;GHz$ and greater than 64 dBc.

Separation of Neodymium from NdEeB Permanent Magnetic Scrap (NdFeB계 영구자석 스크랩으로부터 네오디뮴의 분리회수)

  • Yoon Ho-Sung;Kim Chul-Joo;Lee Jin-Yeung;Kim Sung-Don;Kim Joon-Soo;Lee Jae-Chun
    • Resources Recycling
    • /
    • v.12 no.6
    • /
    • pp.57-63
    • /
    • 2003
  • In this study, the separation of neodymium was investigated from NdFeB permanent magnet scrap. Decomposition and leach-ing process of NdFeB permanent magnet scrap by oxidation roasting and sulfuric arid leaching were examined. Neodymium could be separated from iron by double salt precipitation using sodium sulfate. The optimum conditions established for decom-position and leaching are as follows: oxidation roasting temperature is $500^{\circ}C$ for sintered scrap and $700^{\circ}C$ for bonded scrap, concentration of sulfuric acid in leaching solution is 2.0 M, leaching temperature and time is $50^{\circ}C$ and 2 hrs, and pulp density is 15%. The leaching yield of neodymium and iron was 99.4% and 95.7% respectively. The optimum condition for separation of neodymium by double-salt precipitation was 2 equivalents of sodium sulfate and $50^{\circ}C$ The yield of neodymium was above 99.9%.

The Susceptibility of LNA(Low Noise Amplifier) Due To Front-Door Coupling Under Narrow-Band High Power Electromagnetic Wave (안테나에 커플링되는 협대역 고출력 전자기파에 대한 저잡음 증폭기의 민감성 분석)

  • Hwang, Sun-Mook;Huh, Chang-Su
    • Journal of IKEEE
    • /
    • v.19 no.3
    • /
    • pp.440-446
    • /
    • 2015
  • This study has examined susceptibility of LNA(Low Noise Amplifier) due to Front-Door Coupling under Narrow-Band high power electromagnetic wave. M/DFR(Malfunction/Destruction Failure Rate) was measured to investigate the diagnostic of IC test. In addition, decapsulation analysis was used to understand the inside of the chip state in LNA devices. The experiments is employed as an open-ended waveguide to study the destruction effects of LNA using a 2.45 GHz Magnetron as a high power electromagnetic wave. The susceptibility level of LNA was assessed by electric field strength, and its failure modes were observed. The malfunction of LNA device has showed as the type of self-reset and power-reset. The electric field strength of malfunction threshold is 524 V/m and 1150 V/m respectively. Also, he electric field of destruction threshold is 1530 V/m. Three types of damaged LNA were observed by decapsulation analysis: component, onchipwire, and bondwire destruction. Based on these results, the susceptibility of the LNA can be applied to a database to help elucidate the effects of microwaves on electronic equipment.

Wide-Band 6~10 GHz InGaAs 0.15μm pHEMT 27 dBm Power Amplifier (광대역 응용을 위한 6~10 GHz InGaAs 0.15μm pHEMT 27 dBm급 전력증폭기)

  • Ahn, Hyun-Jun;Sim, Sang-Hoon;Park, Myung-Cheol;Kim, Seung-Min;Park, Bok-Ju;Eo, Yun-Seong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.10
    • /
    • pp.766-772
    • /
    • 2018
  • A 6~10 GHz wide-band power amplifier was designed using an InGaAs enhancement-mode(E-mode) $0.15{\mu}m$ pseudomorphic high-electron-mobility transistor(pHEMT). The positive gate bias of the E-mode pHEMT device removes the need for complex negative voltage generation circuits, therefore reducing the module size. The wire bond and substrate loss parameters were modeled and extracted using a three-dimensional electromagnetic(3D EM) simulation. For wideband characteristics, lossy matching was adopted and the gate bias was optimized for maximum power and efficiency. The measured gain, in/output return loss, output power, and power-added efficiency were greater than 20 dB, 8 dB, 27 dBm, and 35 %, respectively, in the 6~10 GHz band.

Study on Underwater Welding ( Report 1 ) - Its Weldability -

  • 남기우
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.19 no.1
    • /
    • pp.63-70
    • /
    • 1983
  • Recently, many studies for developing the underwater welding techniques have been carried out in the advanced countries as a manufacturing process and a repairing method according as a great deal of interest in development for various marine industrial fields has been gradually increased. But no study on such underwater welding is available at present in our country. In this study, underwater welding was carried out for welding of domestic structural steel plates (SM41A) of 10 mm thickness, using six types of domestic coated arc welding electrodes on a self-made gravity type underwater welding device, resulting in investigation for the underwater weldability of the domestic structural steel plates as well as for the underwater welding properties and practicability of the domestic welding electrodes.

  • PDF

A Study on the Evaluation of Shear Resisting Capacity for the Various Perforated Shape Shear Connector (합성거동을 위한 유공판형 전단연결재의 강도평가에 관한 연구)

  • Kim, Young-Ho
    • Composites Research
    • /
    • v.21 no.5
    • /
    • pp.1-8
    • /
    • 2008
  • In recent years, the reversed L-shaped perforated shear connector has been developed to mitigate the problem associated with headed stud and Perforbond shear connector and to simulate the simultaneous failure of concrete and shear connector. And FRP perforated shear connector has been applied to composite concrete and FRP module in the FRP-concrete composite bridge deck. The design criterion of the reversed L-shaped and FRP perforated shear connector has not been established yet since the lack of experimental and analytical study results. In this paper, the existing design equations for the Perforated were briefly discussed and the equation fur the prediction of shear resisting capacity of the reversed L-shaped and FRP perforated shear connector was suggested based on the experimental test, FEM analysis. and the existing equation for the Perfobond. The predict results obtained by the suggested equation arc compared with the experimental results, the applicability and effectiveness of suggested equation was verified.

Experimental Study on the Flexural Behavior of Inverted T-Shaped Steel·Concrete Composite Deck for Bridges (역T형강·콘크리트 합성바닥판의 휨거동에 관한 실험적 연구)

  • Kim, Sung Hoon;Park, Young Hoon;Lee, Seung Yong;Choi, Jun Hyeok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3A
    • /
    • pp.331-340
    • /
    • 2008
  • This study is to suggest the details of new concept of bridge deck. Experimental studies on the behavior of a inverted T-shaped steelconcrete composite deck were carried out. The part of inverted T-shaped steel is embedded in concrete. Reinforced concrete deck specimen and composite deck specimens were fabricated and static bending fracture tests were conducted. The ultimate strength and fracture strength of specimens were evaluated. The effects of shear hole crossing bars of composite deck were also analyzed. From the results of experiments, composite deck with shear hole crossing bar increased shear strength, and showed typical tensile failure. Ultimate strength and fracture strength of composite deck with shear hole crossing bar are higher than those of reinforced concrete deck. The displacement of composite deck is higher than that of reinforced concrete deck.