• Title/Summary/Keyword: 복합재료판

Search Result 537, Processing Time 0.03 seconds

A Study on Real-Time Defect Detection Using Ultrasound Excited Thermography (초음파 서모그라피를 이용한 실시간 결함 검출에 대한 연구)

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Jung, Hyun-Kyu;Kim, Seung-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.211-219
    • /
    • 2006
  • The UET(ultrasound excited thermography) for the ,eat-time diagnostics of the object employs an infrared camera to image defects of the surface and subsurface which are locally heated using high-frequency putted ultrasonic excitation. The dissipation of high-power ultrasonic energy around the feces of the defects causes an increase In temperature. The defect's image appears as a hot spot (bright IR source) within a dark background field. The UET for nondestructive diagnostic and evaluation is based on the image analysis of the hot spot as a local response to ultrasonic excited heat deposition. In this paper the applicability of VET for fast imaging of defect is described. The ultrasonic energy is injected into the sample through a transducer in the vertical and horizontal directions respectively. The voltage applied to the transducer is measured by digital oscilloscope, and the waveform are compared. Measurements were performed on four kinds of materials: SUS fatigue crack specimen(thickness 14mm), PCB plate(1.8 mm), CFRP plate(3 mm) and Inconel 600 plate (1 mm). A high power ultrasonic energy with pulse durations of 250ms Is injected into the samples in the horizontal and vertical directions respectively The obtained experimental result reveals that the dissipation loss of the ultrasonic energy In the vertical injection is less than that in the horizontal direction. In the cafe or PCB, CFRP, the size of hot spot in the vortical injection if larger than that in horizontal direction. Duration time of the hot spot in the vertical direction is three times as long as that in the horizontal direction. In the case of Inconel 600 plate and SUS sample, the hot spot in the horizontal injection was detected faster than that in the vertical direction

Effect of the difference in spectral outputs of the single and dual-peak LEDs on the microhardness and the color stability of resin composites (Single-peak LED와 dual-peak LED의 출력 파장 차이가 복합 레진 미세 경도와 색 안정성에 미치는 영향)

  • Park, Hye-Jung;Son, Sung-Ae;Hur, Bock;Kim, Hyeon-Cheol;Kwon, Yong-Hoon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.2
    • /
    • pp.108-113
    • /
    • 2011
  • Objectives: To determine the effect of the spectral output of single and dual-peak light emitting diode (LED) curing lights on the microhardness and color stability of commercial resin composites formulated with camphorquinone and alternative photoinitiators in combination. Materials and Methods: Three light-polymerized resin composites (Z100 (3M ESPE), Tetric Ceram (Ivoclar Vivadent) and Aelite LS Posterior (Bisco)) with different photoinitiator systems were used. The resin composites were packed into a Teflon mold (8 mm diameter and 2 mm thickness) on a cover glass. After packing the composites, they were light cured with single-peak and dual-peak LEDs. The Knoop microhardness (KHN) and color difference (${\Delta}E$) for 30 days were measured. The data was analyzed statistically using a student's t-test (p < 0.05). Results: All resin composites showed improved microhardness when a third-generation dual-peak LED light was used. The color stability was also higher for all resin composites with dual-peak LEDs. However, there was a significant difference only for Aelite LS Posterior. Conclusions: The dual-peak LEDs have a beneficial effect on the microhardness and color stability of resin composites formulated with a combination of camphorquinone and alternative photoinitiators.

The Clinical Analysis of Lateral Discoid Meniscus in Adults Over 40 years old (40세 이상에서 발견된 외측 원판형 연골의 임상분석)

  • Lim, Hong-Chul;Noh, Kyoung-Sun;Jung, Hyo-Sub
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.77-82
    • /
    • 2006
  • Purpose: The purpose of this study was to analyze the clinical results of symptomatic lateral discoid meniscus found in adults over 40 years old. Materials & Methods: From March 1994 to March 2004, 53 cases treated for lateral discoid meniscus in 48 patients aged over 40 years with the mean age $48.4(40{\sim}62)$ who were followed up more than 1 year, were analyzed by physical findings, simple X-ray, MRI and arthroscopic exam. Results: Most of the cases (42 cases, 79.2%) had symptoms for less than 1 year duration. 26 cases(49.1 %) out of 53 had trauma history. Simple radiologic evaluation showed that lateral condylar abnormality such as the flattening of lateral femoral condyle, marginal osteophytes, and subchondral sclerosis was seen in 37cases(69.8%). Also medial condyle showed degenerative changes in 16 cases (30.2%). Tear of discoid meniscus in 45 cases(84.9%) were examined by arthroscope and tear was not detected in 8 cases(15.1%). Type of tear was complex(18 cases), longitudinal(12 cases), horizontal(11 cases) and transverse(4 cases). Concomitant medial meniscal rupture was found in 7 cases(13.2%). The simple procedure done was reshaping(46 cases), subtotal resection(5 cases), total resection(1 case) and meniscal repair after reshaping in 6 cases, and arthroplasty was performed after arthroscopic examination in 1 case. Conclusion: Onset of symptom in adult lateral discoid meniscus is usually traumatic in origin. Most cases showed radiologic abnormality such as degenerative change in lateral condyles as well as medial condyles and the results of preservative surgical treatment was the most preferred option in most patients.

  • PDF

Shear Strength Model for Interior Flat Plate-Column Connections (무량판 슬래브-기둥 내부 접합부에 대한 전단강도모델)

  • Choi, Kyoung-Kyu;Park, Hong-Gun
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.345-356
    • /
    • 2010
  • An alternative design method for interior flat plate-column connections subjected to punching shear and unbalanced moment was developed. Since the slab-column connections are severely damaged by flexural cracking before punching shear failure, punching shear was assumed to be resisted mainly by the compression zone of the slab critical section. Considering the interaction with the flexural moment of the slab, the punching shear strength of the compression zone was evaluated based on the material failure criteria of concrete subjected to multiple stresses. The punching shear strength was also used to evaluate the unbalanced moment capacity of the slab-column connections. For verification, the proposed strength model was applied to existing test specimens subjected to direct punching shear or combined punching shear and unbalanced moment. The results showed that the proposed method predicted the strengths of the test specimens better than current design methods in ACI 318 and Eurocode 2.

A study on fatigue properties of GFRP in synthetic sea water (인공해수중 GFRP의 피로특성에 관한 연구)

  • 김연직;임재규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.6
    • /
    • pp.1351-1360
    • /
    • 1993
  • The fatigue behavior of GFRP composites is affected by environmental parameters. Therefore, we have to study on effect of sea water on fatigue behavior of GFRP composites as to maintain the safety and confidence in design of ocean structure of GFRP. In this paper, we investigated the fatigue properties of chopped strand glass mat/polyester composite in synthetic sea water. (pH 8.2) In case of the glass fiber (CSM type) reinforced polyester composite materials, the fatigue crack in the both dry and wet specimens tested in air or synthetic sea water occurred at the initial of cycle. Thereafter, it was divided with two regions that one decreased with the crack extension and the other increased with the crack extension. The transition point occurred during the crack propagation shifted to high ${\Delta}K$ value as load increase but its point is not changed regardless of immersion or test environment under a constant load. The synthetic sea water degrades the bond strength between fiber and matrix, thereby the tendency of rapid deceleration and acceleration of the crack growth was appeared.

Prediction of Fatigue Life in 2 Ply Rubber/Cord Laminate (2층 고무/코드 적층판의 피로 수명 예측)

  • 임동진;이윤기;윤희석;김민호
    • Composites Research
    • /
    • v.16 no.3
    • /
    • pp.9-17
    • /
    • 2003
  • In order to simulate the crack connection between cords and the interply crack growth in the belt-layer of real tire, 2 ply rubber/cord laminate specimens with exposed edges were tested in 4~11mm displacement control. Measurement of the crack connection is evaluated when crack reaches the half of the length between 45$^{\circ}$ aligned cords, and the amount of the crack growth is measured by the steel probe method. 2 dimensional analytic modeling was performed to simulate the crack connection between cords at the exposed edges. Also, the theoretical life of the specimens was calculated from the crack connection life between cords(critical value) and from the critical value to the final failure by the use of Tearing energy(T); the strain energy release per unit area of one fracture surface of a crack. Then, theoretical life was compared with those of experiments. The life prediction up to the critical value has about 20% error compared to experimental life, and up to the final failure about 65% error. Therefore, total theoretical life has about 45% error compared to the experimental life, which is conceivable in the case of rubber.

An Empirical Formulation for Predicting the Thickness of Multilayer PCB (다층 PCB의 두께 예측을 위한 실험식 도출 연구)

  • Kim, Nam-Hoon;Han, Gwan-Hee;Lee, Min-Su;Kim, Hyun-Ho;Shin, Kwang-Bok
    • Composites Research
    • /
    • v.35 no.3
    • /
    • pp.182-187
    • /
    • 2022
  • In this paper, the thickness of a multilayer PCB was predicted through an empirical formulation based on the physical properties of the prepreg used in multilayer PCB. Since the thickness of prepreg reduction when manufacturing a PCB due to the physical properties and copper foil residual rate, it is necessary to accurately predict the thickness of the PCB through the thickness empirical formulation. To determine the density of the prepreg, the mass and thickness of the prepreg were measured. To manufacture the CCL, the prepreg and copper foil were laminated using a hot press machine, and the thickness was measured using a microscope and micrometer. An 8-layerd PCB was designed with different circuit densities to measure the change in the thickness with the copper foil residual ratio, and the proposed empirical formulation was verified by comparing the measured thickness with the value obtained using the empirical formulation. As a result, the errors for the CCL and multilayer PCB were 2.56% and 4.48%, respectively, which demonstrated the reliability of the empirical formulation.

Interfacial shear strength test by a hemi-spherical microbond specimen of carbon fiber and epoxy resin (탄소섬유/에폭시의 반구형 미소접합 시험편에 대한 계면강도 평가)

  • Park, Joo-Eon;Gu, Ja-Uk;Kang, Soo-Keun;Choi, Nak-Sam
    • Composites Research
    • /
    • v.21 no.4
    • /
    • pp.15-21
    • /
    • 2008
  • Interfacial shear strength between epoxy and carbon fiber was analyzed utilizing a hemi-spherical microbond specimens adhered onto single carbon fiber. The hemi-spherical microbond specimen showed high regression coefficient and small standard deviation in the measurement of interfacial strength as compared with a droplet and an inverse hemi-spherical one. This seemed to be caused by the reduced meniscus effects and the reduced stress concentration In the region contacting with a pin-hole loading device. Finite element analysis showed that the stress distributions along the fiber/matrix interface in the hemi-spherical specimen had a stable shear stress distribution along the interface without any stress mode change. The experimental data was also different according to the kinds of loading device such as the microvise-tip and the pin-holed plate.

Improvement on Interfacial, Thermal, and Water Resistance Properties of Wood Sandwich Composites for Stone Bed using CNT-Animal Glue Adhesive (탄소나노튜브/아교 접착제를 이용한 돌침대용 목재 샌드위치 복합재의 계면, 열적 및 방수특성 증가)

  • Kim, Jong-Hyun;Kwon, Dong-Jun;Shin, Pyeong-Su;Baek, Yeong-Min;Park, Ha-Seung;Moon, Sun-Ok;Park, Joung-Man
    • Composites Research
    • /
    • v.30 no.4
    • /
    • pp.235-240
    • /
    • 2017
  • Animal glue, a water-soluble adhesive, has been used historically for high-performance traditional furniture despite the disadvantage of weakness against moisture. Many scientists studied the ways to improve water resistance of animal glue. Improvements on the interfacial, thermal, and water resistance properties of wood sandwich composites (WSC) was studied with carbon nanotube (CNT) wt% in animal glue. Real-time temperature of WSC was measured after WSC was heated with increasing CNT wt%. Lap shear test was performed to determine the interfacial properties of wood and animal glue with CNTs. Water resistance properties of animal glue were determined by lap shear test using specimens dipped in water and the results were compared with the dry case. Hydrophobicity of animal glue by static contact angle was correlated with the variation of lap shear test. Interfacial, thermal, and water resistance properties for animal glue were improved with properly added CNTs.

A Study on Experimental Vibration pre-estimation Techniques of Structure (구조물의 실험적 진동예측 기술에 관한 연구)

  • 이홍기;권형오
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.48-52
    • /
    • 1992
  • 진동원을 가진 장비를 임의의 구조물에 설치할 경우 관심이 되는 문제는 구 조물의 임의의 위치에서의 진동 수준을 추정하는 일이다. 특히 정밀장비를 다루는 반도체 공장에서 크린룸이나, 정밀측정, 분석 실험실등 미진동을 제 어해야 하는 분야에서는 더욱 그 필요성이 대두되고 있다. 진동제어가 필요 한 공간에 대한 진동수준의 예측이 가능할 경우 진동윈이나 수진점(active and passive type)방진에서 최적화된 전달률(transmissibility)을 명확히 결정 할 수 있어 설계와 시행오차를 최소화 할 수 있다. 그러나 이러한 실제문제 를 다룰 경우 대부분 진동제어 구조물은 복잡하고 설치 운용되는 장비들은 대형, 복합장비가 사용되는 것이 일반적이고 수행기간도 여러가지 공정상 단 시간에 이루어져야 하는 현실적인 어려움이 있다. 진동제어가 필요한 구조물 에 대한 임의의 공간에서 진동수준을 신속하고 정확하게 예측하기 위해서는 최소한 두 가지 정보만이라도 명확히 해야 한다. 하나는 장비의 주파수별 정 확한 가진력의 산정이고 다른 하나는 장비가 설치되고 진동제어가 필요한 구조물에 대한 동적특성(dynamic property)이다. 가진력에 대한 정보는 일반 적으로 장비제작사가 제시하는 것이 원칙이나 그렇지 못할 경우 구조해석 기술자(structure engineer)가 해석적으로 추정하거나 또는 명확히 가진 특성 을 알지 못하는 복잡한 장비는 실험적으로 결정해야 한다. 구조물의 동적 특 성을 나타내는 모빌리티(mobility)를 구하는 방법은 해석적인 방법과 실험적 인 방법이 있으나 복합재료, 복잡한 구조형태나, 지지조건, 다양한 결합부의 동적 특성을 정의하여 해석적으로 정확히 해결하기에는 어려움이 있다. 이러 한 제한조건을 손쉽게 해결하는 방법은 실 구조물에 대한 동적실험(dynamic test)을 통하여 단기간에 동적특성을 결정하고 SDM(structure dynamic modification)이나 FRS(force response simulation)를 수행하여 임의의 좌표 공간에 대한 진동수준을 해석적으로 예측할 뿐만 아니라 구조물의 진동제어 를 위한 동적인자를 변경시킬 수 있는 정보를 제공하며 장비를 방진할 경우 신뢰성 있는 전달률을 결정할 수 있다. 실험적으로 철교, 교량이나 건물의 철골구조 및 2층 바닥 등 대,중형의 복잡한 구조물에 대항 동특성을 나타내 는 모빌리티를 결정할 경우 충격 가진 실험이 사용되는 실험장비 측면에서 나 실험을 수행하는 과정이 대체적으로 간편하다. 그러나 이 경우 대상 구조 물을 충분히 가진시킬수 있는 용량의 대형 충격기(large impact hammer)가 필요하게 된다. 이러한 동적실험은 약 길이 61m, 폭 16m의 4경간 교량에 대 하여 동적실험을 수행하여 가능성을 확인하였다. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다.

  • PDF