Browse > Article
http://dx.doi.org/10.4334/JKCI.2010.22.3.345

Shear Strength Model for Interior Flat Plate-Column Connections  

Choi, Kyoung-Kyu (School of Architecture, Soongsil University)
Park, Hong-Gun (Dept. of Architecture, Seoul National University)
Publication Information
Journal of the Korea Concrete Institute / v.22, no.3, 2010 , pp. 345-356 More about this Journal
Abstract
An alternative design method for interior flat plate-column connections subjected to punching shear and unbalanced moment was developed. Since the slab-column connections are severely damaged by flexural cracking before punching shear failure, punching shear was assumed to be resisted mainly by the compression zone of the slab critical section. Considering the interaction with the flexural moment of the slab, the punching shear strength of the compression zone was evaluated based on the material failure criteria of concrete subjected to multiple stresses. The punching shear strength was also used to evaluate the unbalanced moment capacity of the slab-column connections. For verification, the proposed strength model was applied to existing test specimens subjected to direct punching shear or combined punching shear and unbalanced moment. The results showed that the proposed method predicted the strengths of the test specimens better than current design methods in ACI 318 and Eurocode 2.
Keywords
slab-column connections; concrete slabs; direct punching shear; eccentric shear; unbalanced moment;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Choi, K., Reda Taha, M. M., Park, H., and Maji, A. K., “Punching Shear Strength of Interior Concrete Slab-column Connections Reinforced with Steel Fibers,” Cement and Concrete Composites, Vol. 29, No. 5, 2007, pp. 409-420.   DOI   ScienceOn
2 Chen W. F., Plasticity in Reinforced Concrete, New York, McGraw-Hill, 1982, pp. 204-205.
3 Kupfer, H. B., Hildorf, H. K., and Rusch, H., “Behavior of Concrete under Biaxial Stresses,” ACI J., Vol. 66, No. 8, 1969, pp. 656-666.
4 CSA A23.3-M04 Technical Ccommittee, Design of Concrete Structures, Canadian Standards Associations, Toronto, Ontario, 2004.
5 Manterola, M., “Poinconnement de Ddalles Ssans Aarmature d’effort Ttrenchant,” ComiteEuropeen du Beton (Hrsg.), Dalles, Structures Pplanes, CEB-Bull, Paris, d’Information 1966, 58 pp.
6 Farhey, D. N., Adin, M. A., and Yankelevsky, D. Z., “Flat Slab-Column Subassemblages under Lateral Loading,” J. Struct. Engrg., ASCE, Vol. 119, No. 6, 1993, pp. 1903-1916.   DOI   ScienceOn
7 Ramdane, K. E., “Punching Shear of High Performance Concrete Slabs,” Utilization of High Strength/high Performance Concrete, Laboratoire Central des Ponts et Chausees, Paris, Vol. 3, 1996, pp. 1015-1026.
8 Marzouk, H. and Hussein, A., “Experimental Investigation on the Behavior of High-strength Concrete Slabs,” ACI Struct. J., Vol. 88, No. 6, 1991, pp. 701-713.
9 Regan, P., “Symmetric Punching of Reinforced Concrete Slabs,” Magazine of concrete research, Vol. 38S, 1986, pp. 115-128.
10 Morrison, D. G. and Sozen, M. A., “Response of Reinforced Concrete Plate-Column Connections to Dynamic and Static Horizontal Loads,” Civil Engineering Studies, Structural Research Series, No. 490, University of Illinois, Urbana, Apr. 1981.
11 Park, H. and Choi, K., “Improved Strength Model for Interior Flat Plate-column Connections Subject to Unbalanced Moment,” ASCE J. Structural Engrg., Vol. 132, No. 5, 2006, pp. 694-704.   DOI   ScienceOn
12 Tian, Y., Jirsa, J. O., and Bayrak, O., “Nonlinear Modeling of Slab-column Connections under Cyclic Loading,” ACI Struct. J., Vol. 106, No. 1, 2009, pp. 30-38.
13 Zararis, P. D. and Papadakis, G. C., “Diagonal Shear Failure and Size Effect in RC Beams without Web Reinforcement,” J. Struct. Engrg., ASCE, Vol. 127, No. 7, 2001, pp. 733-742.   DOI   ScienceOn
14 Park, H., Choi, K., and Wight, J. K., “Strain-based Shear Strength Model for Slender Beams without Web Reinforcement,” ACI Struct. J., Vol. 103, No. 6, 2006, pp. 783-793.
15 Choi, K., Park, H., and Wight, J. K., “Unified Shear Strength Model for Reinforced Concrete Beams- Part I: Development,” ACI Struct. J., Vol. 104, No. 2, 2007, pp. 142-152.
16 Kotsovos, M. D. and Pavlovic, M. N., Ultimate Limit-state Design of Concrete Structures: a New Approach, Thomas Telford, London, 1998. 208 pp.
17 Jelic, I., Pavlovic, M. N., and Kotsovos, M. D., “A Study of Dowel Action in Reinforced Concrete Beams,” Magazine of Concrete Research, Vol. 51, No. 2, 1999, pp. 131-141.   DOI   ScienceOn
18 Tureyen, A. K. and Frosch, R. J., “Concrete Shear Strength: Another Perspective,” ACI Struct. J., Vol. 100, No. 5, 2003, pp. 609-615.
19 FIP 12, Punching of Structural Concrete Slabs, CEB-FIP Task Group, Lausanne, Switzerland; 2001, 314 pp.
20 최경규, 박홍근, “플랫플레이트-기둥 접합부의 뚫림전단 강도,” 콘크리트학회지, 14권, 6호, 2002, pp. 961-972.
21 Long, A. E. and Rankin, G. I. B., “Prediction of the Punching Strength of Conventional Slab-column Specimens,” Proc. Institution Civ. Engrs., Vol. 82, 1987, pp. 327-345.   DOI
22 Pralong, J., Poinconnement Symetrique Des Plachersdalles, IBK-Bericht Nr., 131, Insitut fur Baustatik und Konstruktion ETH Zurish, 1982.
23 Kinnunen, S. and Nylander, H., “Punching of Concrete Slabs without Shear Reinforcement,” Transactions, No. 158, Royal Institute of Technology, Stockholm, 1960, 112 pp.
24 Luo, Y. H. and Durrani, A. J., “Equivalent Beam Model for Flat-slab Buildings-Part I: Interior Connections,” ACI Struct. J., Vol. 92, No. 1, 1995, pp. 115-124.
25 Alexander, S. D. B. and Simmonds, S. H., “Ultimate Strength of Slab-Column Connections,” ACI Struct. J., Vol. 84, No. 3, 1987, pp. 255-261.
26 Bazant, Z. P. and Cao, Z., “Size Effect in Punching Shear Failure of Slabs,” ACI Struct. J., Vol. 84, No. 1, 1987, pp. 44-53.
27 Pan, A. and Moehle, J. P., “Later Displacement Ductility of Reinforced Concrete Flat Plates,” ACI Struct. J., Vol. 86, No. 3, 1989, pp. 250-258.
28 최경규, 박홍근, “플랫플레이트-기둥 접합부의 뚫림전단 강도,” 콘크리트학회지, 16권, 2호, 2004, pp. 163-174.   과학기술학회마을   DOI   ScienceOn
29 ACI Committee 318, Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary (ACI 318R-08), Amerian Concrete Institute, USA, 2008, 473 pp.
30 CEB-FIP MC 90, Design of Concrete Structures, CEB-FIPModel-Code 1990, Thomas Telford, 1993, 437 pp.
31 BS 8110, Structural Use of Concrete, Part 1, Code of Practice for Design and Construction, British Standards Institution, London, 1997, 172 pp.
32 EC 2, Design of Concrete Structures Part I: General Rules and Rules for Buildings, European Committee for Standardization Brussels, 2002, 225 pp.
33 Yitzhaki, D., “Punching Strength of Reinforced Concrete Slabs,” ACI J., 1966, Vol. 63, No. 5, pp. 527-542.
34 MacGregor, J. G. and Wight, J. K., Reinforced Concrete: Mechanics and Design, Prentice Hall, NJ, 2005, 1132 pp.