• Title/Summary/Keyword: 복합신소재구조물

Search Result 64, Processing Time 0.022 seconds

Continuum Based Plasticity Models for Cubic Symmetry Lattice Materials Under Multi-Surface Loading (다중면 하중하에 정방향 대층구조를 가진 격자재료의 연속적인 소성모델)

  • Seon, Woo-Hyun;Hu, Jong-Wan
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.3
    • /
    • pp.1-11
    • /
    • 2011
  • The typical truss-lattice material successively packed by repeated cubic symmetric unit cells consists of sub-elements (SE) proposed in this study. The representative continuum model for this truss-lattice material such as the effective strain and stress relationship can be formulated by the homogenization procedure based on the notation of averaged mechanical properties. The volume fractions of micro-scale struts have a significant influence on the effective strength as well as the relative density in the lattice plate with replicable unit cell structures. Most of the strength contribution in the lattice material is induced by axial stiffness under uniform stretching or compression responses. Therefore, continuum based constitutive models composed of homogenized member stiffness include these mechanical characteristics with respect to strength, internal stress state, material density based on the volume fraction and even failure modes. It can be also recognized that the stress state of micro-scale struts is directly associated with the continuum constitutive model. The plastic flow at the micro-scale stress can extend the envelope of the analytical stress function on the surface of macro-scale stress derived from homogenized constitutive equations. The main focus of this study is to investigate the basic topology of unit cell structures with the cubic symmetric system and to formulate the plastic models to predict pressure dependent macro-scale stress surface functions.

Study on the Crack and Thermal Degradation of GFRP for UPE Gelcoat Coated Underground Pipes Under the High Temperature Water-Immersion Environment (고온 수침 환경에서 UPE 겔코트 코팅된 지중 매설 파이프용 GFRP의 열화 및 크랙 발생 특성에 관한 연구)

  • Kim, Daehoon;Eom, Jaewon;Ko, Youngjong;Lee, Kang-Il
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.169-177
    • /
    • 2018
  • Glass fiber reinforced polyester (GFRP) composites are widely used as structural materials in harsh environment such as underground pipes, tanks and boat hulls, which requires long-term water resistance. Especially, these materials might be damaged due to delamination between gelcoat and composites through an osmotic process when they are immersed in water. In this study, GFRP laminates were prepared by surface treatment of UPE (unsaturated polyester) gelcoat by vacuum infusion process to improve the durability of composite materials used in underground pipes. The composite surface coated with gelcoat was examined for surface defects, cracking, and hardness change characteristics in water-immersion environments (different temperatures of $60^{\circ}C$, $75^{\circ}C$, and $85^{\circ}C$). The penetration depth of cracks was investigated by micro CT imaging according to water immersion temperature. It was confirmed that cracks developed into the composites material at $75^{\circ}C$ and $85^{\circ}C$ causing loss of durability of the materials. The point at which the initial crack initiated was defined as the failure time and the life expectancy at $23^{\circ}C$ was measured using the Arrhenius equation. The results from this study is expected to be applied to reliability evaluation of various industrial fields where gelcoat is applied such as civil engineering, construction, and marine industry.

재료 및 파괴부문

  • 김영진
    • Journal of the KSME
    • /
    • v.43 no.8
    • /
    • pp.32-43
    • /
    • 2003
  • 2002년도 재료 및 파괴부문의 연구는 예년에 비해 더욱 활성화되었다. 부문 학술대회에서 효율적인 학술토의 및 아이디어 교환을 위해 기획 세션을 구성하여 대회를 운영하였으며, 기획 세션의 종료 및 세션 조직위원으로 활동한 회원은 다음과 가다. CAE/피로설계(이영신, MSC Korea), 신소재 및 복합재료(한경섭, 포항공대), 접합부의 강도평가(남기우, 부경대), 신뢰성 평가(진태은, 한전기술), 구조물의 손상평가(신병천, KIMM), NDT 기법 응용(윤동진, 표준연), 전자패키징 신뢰서(이순복, KAIST), 계산역학(박재학, 충북대), 발전소요소 진단 및 평가(박윤원, 원자력안전기술원), RBI-FFS-IT(최지붕, 성균관대), NT 분야(박준협, 동명정보대), 에너지 및 화력발전분야(하정수, 전력연구원)이다. 본 연감의 내용도 위에 언급한 기획 세션 주제별로 나누어 활동 사항을 요약하였다. 일부 논문은 분야가 중복되기도 하지만 본 연감에서는 주요 세션에서만 언급하였으며, 지면 관계상 많은 우수한 연구 활동에 대해 적절히 언급되지 못한 면도 있음을 발혀둔다.

  • PDF

Numerical Analysis on the Behavior of Revetment Reinforced by Sand Compaction Pile According to Area Replacement Ratio (수치해석을 이용한 모래다짐말뚝 치환율에 따른 호안 구조물의 거동 분석)

  • Kim, Byoung-Il;Bong, Tae-Ho;Han, Jin-Tae;Jang, Young-Eun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.3
    • /
    • pp.1-8
    • /
    • 2018
  • Sand compaction pile (SCP) is a ground improvement method which is used to secure the stability of the soft ground by using a type of replacement pile filled with coarse grained material. The behavior characteristics of the SCP, which is frequently used for improving both the onshore and offshore ground, is governed by the ground condition, the installation method, and replacement ratio. Therefore, the stability of the SCP in terms of the bearing capacity and displacement needs to be evaluated considering both the design values and in-situ conditions of construction site. In this study, numerical analysis is carried out based on the conditions of 00 revetment construction site in South Korea where unexpected displacement occurred during construction of SCP. Based on the analysis results, the displacement of the revetment structure according to the replacement ratio of the SCP was compared to the result calculated from design formulas. The results showed that the lateral displacement can be exceeded the reference value from proposed criteria regardless of increased replacement ratio of SPC. It is also confirmed that the behavior of the structure according to the replacement ratio of SPC in not reflected in the existing calculation methods. Therefore, the stability of the SCP composite ground should be examined through the site inspection after the SCP construction.

Analysis on the Shear Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel (L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 전단 거동 분석)

  • Yu, Sung-Yong;Ju, Ho-Seong;Ha, Soo-Kyoung
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.2
    • /
    • pp.105-117
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.

Experimental Investigations of Combination Effects of Installation Damage and Creep Deformation on Long-Term Design Strength of Geogrids (지오그리드의 장기설계인장강도에 미치는 시공시 손상 및 크리프 변형 복합효과에 대한 실험적 평가)

  • Cho, Sam-Deok;Lee, Kwang-Wu;Oh, Se-Yong;Lee, Do-Hee
    • Journal of the Korean Geosynthetics Society
    • /
    • v.4 no.4
    • /
    • pp.23-37
    • /
    • 2005
  • The factors affecting the long-term design strength of geogrid can be classified into factors on creep deformation, installation damage, temperature, chemical degradation and biological degradation. Especially, creep deformation and installation damage are considered as main factors to determine the long-term design strength of geogrid. Current practice in the design of a reinforced soil structures is to calculate the long-term design strength of a geosynthetic reinforcement damaged during installation by multiplying the two partial safety factors, $RF_{ID}$ and $RF_{CR}$. This method assumes that there is no evaluation of synergy effect between installation damage and creep deformation of geogrids. This paper describes the results of a series of experimental study, which are carried out to assess the combined effect of the installation damage and the creep deformation for the long-term design strength of geogrid reinforcements. A series of field tests was carried out to assess installation damage of various geogrids with respect to different fill materials, and then creep tests are conducted to evaluate the creep deformation of both undamaged and damaged geogrids. The results indicated that the tensile strength reduction factors, RF, considering the combined effect between the installation damage and the creep deformation is less than that calculated by the current design method.

  • PDF

Numerical Analyses of Critical Buckling Loads and Modes of Anisotropic Laminated Composite Plates (비등방성 복합 적층판의 임계좌굴하중 및 모드의 수치 해석)

  • Lee, Sang Youl;Yhim, Sung Soon;Chang, Suk Yoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.3 s.36
    • /
    • pp.451-461
    • /
    • 1998
  • The solution of anisotropic plate via the classical methods is limited to relatively load and boundary conditions. If these conditions are more complex, the analysis becomes increasingly tedious and even impossible. For many plate problems of considerable practical interest, analytic solutions to the governing differential equations cannot be found. Among the numerical techniques presently available, the finite difference method and the finite element method are powerful numerical methods. The objective of this paper is to compare with each numerical methods for the buckling load and modes of anisotropic composite laminated plates considering shear deformation. In applying numerical methods to solve differential equations of anisotropic plates, this study uses the finite difference method and the finite element method. In determining the eigenvalue by Finite Difference Method, this paper represent good convergence compared with Finite Element Method. Several numerical examples and buckling modes show the effectiveness of various numerical methods and they will give a guides in deciding minimum buckling load and various mode shapes.

  • PDF

Effect of Intestinal Function Enhancer (KTG075) on Mucin 2 Secretion (장기능개선제-신소재(KTG075)의 대장관 내 mucin 2 분비에 미치는 영향)

  • Lee, You-Hui;Baik, Soon-Ok;Kim, Hyun-Kyung;Ryu, Myung-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.991-994
    • /
    • 2004
  • Effects of formulation KTG075 from edible plants on intestinal function, particularly on Mucin 2 secretion, were examined by loperamide-induced constipation method using Sprague Dawley rats (SD rats, male). Crypt epithelial cells containing more mucus and mucus layer stained with alcian blue were significantly thicker in KTG075 group than control group. When Biogenex AM358 of antibody against Mucin 2 was used, crypt epithelial cells secreted more Mucin 2 in KTG075 group than control group. The Mucus layer at fecal surface was thinner and less mucus was recovered from mucosal surface in constipated rats than in KTG075 group. Mucus production of crypt epithelial cells and mucus contents at fecal and mucosal surfaces were reduced by loperamide-induced constipation. These results indicate formula KTG075 accelerates evacuation and activates intestines.

Feasibility and Filtering Efficiency of Geotextile Tube Structure with Polymer Material (지오텍스타일 재질에 따른 필터성능 및 튜브구조물 적용성 분석)

  • Oh, Young-In;Shin, Eun-Chul;Kim, Sung-Yoon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.4 no.1
    • /
    • pp.7-15
    • /
    • 2005
  • In recent years, the geotextile tubes filled with dredged material have been used in dike and breakwater construction for a number of projects around the world, and their use in this field is growing very fast. One of the most attractive advantages of geotextile tube technology is can be use the in-situ filling materials by hydraulic pumping, it can be also established lower costs and fast construction than other technology. Geotextiles form one of the two largest groups of geosynthetics and it is commonly made by two major types of polymer material(Polypropylene, Polyester). The objective of this paper is to examine several issues associated with drainage function and feasibility of geotextile tube structure such as filtering efficiency, dewatering efficiency, and filling process with polymer materials. Based on the laboratory filtering test and in-situ tests, polypropylene goetextile is more effective for drainage function of geotextile tube technology.

  • PDF

Numerical Study on Direct Shear Test of Composite Shotcrete with Sprayable Waterproofing Membrane (차수용 박층 멤브레인의 직접전단실험에 관한 수치해석 연구)

  • Lee, Kicheol;Choi, Soon-Wook;Kim, Dongwook;Lee, Chulho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.189-197
    • /
    • 2018
  • A sprayable waterproofing membrane which has relatively high adhesive property onto concrete enables faster construction with better waterproof performance compared with a conventional sheet membrane. However, the sprayable waterproofing membrane is a recently developed material and its performance and behavior with structures are not sufficiently reported. Therefore, in this study, the shear behavior of sprayable waterproofing membrane was numerically analyzed using the results of previous studies of composite shotcrete with sprayable waterproofing membrane. From the previous study, shear behavior of shotcrete with sprayable waterproofing membrane was different from shotcrete case and there was a limitation to express the behavior of the interface in general shear strength method. Therefore, in this study, the direct shear test was numerically simulated using two contact models, and then the best suitable method to express the shear behavior of the sprayable waterproofing membrane was suggested.