• Title/Summary/Keyword: 복합시설물

Search Result 142, Processing Time 0.034 seconds

Scheduling Technique for Remodeling Project of Inhabited Condition (재실 리모델링 특성을 반영한 공정계획 기법)

  • Paik, Hwa-Sook;Nam, Wook-Jin;Kim, Sung-Han;Kim, Hyung-Jin;Choi, Jong-Soo;Kim, Kyung-Hwan
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.2
    • /
    • pp.141-149
    • /
    • 2013
  • This paper presents a scheduling technique that reflects various constraints in remodeling project of inhabited condition. The remodeling project of inhabited condition is required more detailed planning and control due to claims by noise, vibration, dust, smells, limited lift capacity, and limited temporary stock area. Because of the constraints, complexity in scheduling is increased and earlier completion is required to reduce the possibility of safety and environment accidents. Especially, in case of inhabited condition, the scheduling should be linked day-time/night-time/weekend work. This paper proposes a structured scheduling technique to incorporate those constraints in remodeling of inhabited condition. This scheduling technique considers not only remodeling process but also dismantling, newly-construction, and residents movement. Process expression method using MS-Project also presented to keep connectivity with existing scheduling system.

An analysis of related parameters of the detention pond in trunk sewer considering temporal distribution of rainfall (강우의 시간적 분포를 고려한 간선저류지의 관련매개변수 분석)

  • Lee, Sung Ho;Lee, Jae Joon;Lee, Hoo Sang;Rhee, Dong Sop
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.214-214
    • /
    • 2017
  • 우리나라는 도시화 및 산업화로 도시지역의 대부분이 불투수층으로 변화하였으며, 국지성 호우의증가로 홍수 저감시설의 방어능력이 취약한 실정이다. 따라서 홍수방어 개선을 위한 여러 방안들이 이루어지고 있으며, 그 중 저류지는 도시지역에서 유역 하류의 홍수피해 저감 및 흐름을 지체시켜 유출률을 감소시키는 시설물로 홍수 저감을 위한 시설물로 가장 많이 사용되고 있다. 저류지는 큰 규모일수록 유역의 하류지역에 설치할 경우 가장 큰 유출저감효과를 가지는 것으로 알려져 있다. 하지만 저류지의 위치를 유역의 하류가 아닌 상류지역에 설치할 경우에는 단기간 강우의 시간적 분포가 강우 초기에 집중될 경우 저류지의 허용용량이 초기에 도달하게 되어 추가적인 강우가 발생할 경우 본래의 역할을 하지 못하는 경우가 빈번하게 발생하고 있다. 그러므로 다양한 강우강도 및 시간적 분포를 고려하여 유역의 특성 및 저류지의 설치위치에 따른 관계를 분석할 필요가 있다. 본 연구에서는 도시화, 산업화 인구집중으로 인해 동일규모의 강우에서도 우수유출이 증대되고 있는 도시지역에서 원활한 내수배제를 위해 기존의 우수관거를 연계한 저류시스템인 간선저류지 개념을 적용하여 강우강도 및 시간적 분포에 따른 간선저류지의 관련매개변수를 분석하였다. 대상유역은 세장형, 집중형, 중앙형의 3가지 형상의 가상유역으로 선정하여 다양한 지속기간의 강우량을 적용하였으며, 간선저류지의 설치위치는 전체 유역면적에 대한 저류지 상류부 면적의 비(저류지 상류부 면적비, DUAR ; Dimensionless Upstream Area Ratio)를 20%, 40%, 60%, 80%로 변화시키면서 강우의 시간적 분포에 따른 간선저류지의 매개변수 분석에 관한 연구를 진행하였다.

  • PDF

A Fundamental Study about a Quality Certification of 3D Precision Indoor Geospatial Information - Focused on Yeongdeungpo Station - (3차원 정밀 실내공간정보 품질인증 방안에 관한 기초연구 - 영등포역을 중심으로-)

  • Lee, Ki Sung;Jeong, In Hun;Choi, Yun Soo;Kim, Sang Bong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.1
    • /
    • pp.3-14
    • /
    • 2015
  • As buildings in the downtown area, such as the complex building connected to the skyscraper and the underground facility, have become large and complex, the range of target domain of the space information service is rapidly expanding to the interior space; it is considered that this change will create various demands of service such as the indoor geospatial information base safety, the management of facility, and the interior navigation in the future, along with spread of mobile devices and development of IT technology. As for the indoor geospatial information, however, there is no certification standard of the established indoor geospatial information data quality, so preparing the certification standard is urgent. Thus, this study reviewed foreign and domestic research cases and prepared measures for quality verification of the indoor geospatial information to conduct a verification test of the Yeongdeungpo Station indoor geospatial information, established in 2014. As a result, through the verification test of the method and standard of the indoor geospatial information quality certification suggested by this research, it was identified that the uniform and higher quality data could be classified, and the types of error high frequently occurring could be investigated. These results are expected to be utilized as the basic data for establishing quality certification system for the indoor geospatial information in the future.

Application of SP Survey and Numerical Modeling to the Leakage Problem of Irrigation facilities (수리시설물 누수탐지에 대한 자연전위법 적용 및 수치 해석)

  • Song Sung-Ho;Kwon Byung-Doo;Yang Jun-Mo;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.257-261
    • /
    • 2002
  • We have carried out integrated research including field survey and numerical modeling to appraise the applicability of SP method to the leakage problems of irrigation facilities. The leakage pattern of the dike studied here can be classified into the three categories: leakage through the abutment, leakage by piping through dike, and leakage due to the composite effects of landslide and distortion of the dike structure. for the numerical modeling to interpret quantitatively SP survey results acquired at dike, we have modified the computer code proposed by Sill (1983) to apply to the leakage problems. The numerical studies match the characteristic patterns of SP anomalies according to the leakage types and appear to be very useful to interpret the leakage zone and path. The SP monitoring results were also well coincided with tidal variations observed at every embankment so we found the SP method is quite effective not only to detect the leakage zone but also to determine the leakage trend. The numerical modeling results also reproduced the SP anomalies due to seawater leakage in the embankment.

Development of Hybrid Power Storage System for Urban Railway with UPS Function for Emergency Power Generation (비상발전용 UPS 기능을 갖춘 도시철도용 복합형 전력저장시스템 개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.191-196
    • /
    • 2019
  • In the case of urban railway facilities, the power supply should be maintained for the safe movement of passengers in communication facilities, disaster prevention facilities and boarding area security because of the confusion when power supply is cut off due to the nature of public transportation. In addition, considering that the number of trains is running on the urban railway line, it is necessary to operate at least 30 minutes for the bus stop and at least 1 hour for the communication and disaster prevention facilities. Therefore, it is essential to supply emergency power source to maintain stable operation of induction lamp and smoke exhaust system because main power is cut off in order to prevent further spread due to fire in case of the history of urban railway section or vehicle fires. Recently, UPS(Uninterruptible Power Supply) function to prevent power outage in emergency, emergency power generation combined with ESS function which saves electricity at nighttime price time, A hybrid power storage system with a UPS function.

Construction Stage Analysis of Structure Settlement Using Underpinning (언더피닝 공법을 이용한 구조물 침하에 대한 시공 단계 해석)

  • Lee, Jonghyop;Heo, Seungjin;Ok, Suyeol;Lim, Yunmook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3A
    • /
    • pp.131-138
    • /
    • 2012
  • This paper aims to present accurately analytical modeling method for underpinning using uncertainty reduction, obtained from comparison between numerical analysis and Site measuring data during construction and service stages. Combination of various conditions should be considered for using numerical analysis to predict the behavior of the structure accurately, even though complexly considered the conditions, real construction should be secured the stability by applying the actual instrument measurement data because predicted results are including the considerable uncertainty. In order to secure the stability during construction, the real time instrument measurements together with numerical analysis results performed before construction state are complementary used actively. From the results of this study, the significant settlements are occurred not only in underpass structure of adjacent excavation area but also in the permanent steel pipe structures were analyzed. From the site measurement results of underpass settlement, the settlements are occurred in every stages of excavation, furthermore observed tendency is asymmetrical excavation patterns are settled more than symmetrical excavation patterns. The essential consideration points for numerical analysis are construction sequence, the direction of the existing facilities, the methods of elements modeling, the applied factors for nature of material and different results would be occurred depending upon inputting the above factors.

A Study on Indoor Route Guidance at Railway Stations for the Transportation Vulnerable (교통약자의 철도역 실내 길안내 방안에 관한 연구)

  • Jae-Bum Shin;Seong-Cheol Kim
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.4
    • /
    • pp.167-178
    • /
    • 2023
  • Our society is rapidly changing, and there is a growing demand for various convenience services in our daily lives. Among these services, railway and subway stations require tailored wayfinding services to accommodate individuals with disabilities. Currently, signage and information desks are the primary means of navigation. However, individuals with disabilities often rely on assistance from others due to physical discomfort or cognitive impairments. In this paper, we propose a customized wayfinding system within railway stations to assist individuals with disabilities. This system aims to ensure safe and convenient mobility in complex indoor environments, including transfer facilities.

The Media Pole Design Applying the Playfulness of Scribbling (낙서의 유희성을 반영한 '미디어 폴' 디자인)

  • Kim, Hee Eun;Ryoo, Han Young
    • Design Convergence Study
    • /
    • v.14 no.5
    • /
    • pp.103-115
    • /
    • 2015
  • This study sheds light on the entertaining aspects of Media Pole that is located in Gangnam U-Street and proposes design that considers the aspects of the form, experience, contents and communication of scribbling. Functioning as public digital media, Media Pole provides various convenient services related to the area. According to the research on user's behavior upon Media Pole, photo related services, which can be categorized as entertainment, were found to be the most frequently used services among various services. Taking user's behaviors into consideration, this study highlights the entertaining aspects of Media Pole and suggests design that applies the playfulness of scribbling. The playful characteristics of scribbling were applied to the Media Pole's user interface, interaction, application and interlocking functions. As a result, users are expected to increase as Media Pole becomes more playful than before. Since scribbling is an act of intrinsic human's desire, it will attract users to participate more voluntarily. It can be applied not only to Media Pole, but to any public digital media devices.

A study on the optimal reinforced zone of a small sectional shield TBM tunnel in difficult ground (특수지반 구간의 소단면 쉴드 TBM 터널 굴착 시 최적 보강영역 연구)

  • Kang, Byung-Yun;Park, Hyung-Keun;Cha, Jae-Hoon;Kim, Young-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.735-747
    • /
    • 2019
  • Due to the lack of ground space by urbanization, the demand of utility tunnels for laying social facilities is increasing. During the construction of a utility tunnel in downtown area using a shield TBM, various problems may occur when difficult ground is encountered such as mixed ground and cobbly ground. Thus, in this study, using MIDAS GTS NX (Ver. 280), a numerical analysis was performed on characteristics of difficult ground, reinforced area, depth of cover and groundwater level to analyze the optimal ground reinforced area according to combination of parameters. As a result, it was difficult to secure stability in unconstrained excavation cases on both the mixed ground and the cobbly ground. However, when ground reinforcement grouting as much as 2.0D is applied, convergence occurred within the allowable limit, except for mixed ground with a depth of cover 30 m. In addition, excessive leakage occurred during excavation of both the mixed ground and the cobbly layers. It was able to secure stability after applying waterproof grouting.

The Korea Academia-Industrial cooperation Society (유리섬유 복합재료를 이용한 화재 비상통로용 스크린 소재 성능에 관한 연구)

  • Lee, Jung-Yub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.653-659
    • /
    • 2018
  • High-rise buildings and complex facilities are a representative urban system for the masses, and it requires an increasing role of commodity and safety. Smoke and toxic gasses can cause accidents due to fire in these systems. The purpose of this study is to develop a fiber screen material for emergency evacuation passages that can be avoided quickly and safely in cases of disasters. The fiber screen material is applicable to folding devices for emergency evacuation passages. The material is different from general steel material in that it is lightweight with less burden during storage for a long time in a roll form in a folding device. It also has an excellent secondary function in that it is less affected by radiant heat. Three kinds of fiber screen materials were selected that have good flame retardancy and post-processing characteristics. A performance evaluation was performed by a heat shrinkage test, contact heat test, combustibility test, flame retardancy test, tensile strength test, and tear strength test. As a result, the lightweight fabric shows excellent performance through post-processing, and silicone resin coating can secure safety of the pizza by the fiber screen material performance and radiant heat. The optimum post-treatment conditions were evaluated by performing a burning test after coating two kinds of glass fibers and four types of flame-retardant silicone resins with different weight and thickness.