• Title/Summary/Keyword: 복조

Search Result 653, Processing Time 0.02 seconds

Burst Mode AGC Loop and Preamble Detector for VDL Mode-2 (VDL Mode-2 를 위한 버스트 모드 AGC 루프 및 프리엠블 검출기)

  • Gim, Jong-Man;Eun, Chang-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.7C
    • /
    • pp.706-714
    • /
    • 2009
  • In this paper, we proposed a burst mode AGC loop and preamble detector applicable for VDL(VHF Digital Link) mode-2 using D8PSK modulation scheme and the performance analysis of proposed schemes is described. Generally the AGC scheme can be divided into two types, continuos and burst mode AGC. The continuos mode is performed well only with an analog feedback AGC loop. But the analog feedback AGC loop is not suitable for burst mode since its gain lock time is more than preamble duration, which causes the preamble detector misses preamble. Hence a fast digital AGC loop is required for burst mode. Also the AGC loop has to be designed with full gain during idle time to detect bursts although the signal level is very low. If the time to acquire gain lock is slow, the preamble detector fail to detect burst due to saturation of a lot of preamble samples. The receiver performance might be down even if the burst was detected because the preamble is used to estimate several parameters need to demodulation at receiver. In this paper we analysed relationships between the AGC loop and preamble detector. we present an AGC loop and preamble detector in burst mode.

HIDDEN CARIES: CASE REPORT (Hidden caries의 치험례)

  • Yoon, Hye-Jeong;Kim, Seong-Oh;Son, Heung-Kyu;Choi, Byung-Jai;Lee, Jae-Ho;Song, Je-Seon;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.4
    • /
    • pp.532-536
    • /
    • 2010
  • Hidden caries is a subtype of the occlusal pit and fissure caries type and is defined as a dentinal caries lesion near the occlusal surface of the tooth seen on a radiograph. In visual examination, the occlusal enamel is seen intact or is minimally perforated. Covert caries, Occlult caries or Fluoride syndrome are used as synonym. The percentage of occlusal dentin lesions that are clinically undetected ranges from 1.4-50%. Little is known about the mechanisms involved in the development of hidden caries. But it is thought that extensive use of topical fluoride or the special bacteriological profile has been a major factor. This case report is about detection and treatment of hidden caries of two children who visited the department of pediatric dentistry, Yonsei University Dental Hospital. The color of caries dentin found in hidden caries lesion is lighter than cavity forming caries, which makes it more difficult to detect caries by visual examination. Therefore diagnosis of hidden caries is often accomplished after clinical sign is recognized by patients. The use of advanced caries detection aids such as Diagnodent.. with periodic radiographic examination is seemed to be helpful for early detection of hidden caries.

Microleakage and Shear Bond Strength of Biodentine at Different Setting Time (BiodentineTM의 경화시간에 따른 미세누출과 전단결합강도)

  • Song, Yong Ho;Lee, Nanyoung;Lee, Sangho;Jih, Myeongkwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.3
    • /
    • pp.344-353
    • /
    • 2018
  • The purposes of this study were to evaluate microleakage of Biodentine, one of the tricalcium silicate based pulp-capping materials, and to compare the shear bond strength between composite resin and Biodentine with different setting times. For microleakage evaluation, 70 bovine teeth were used. Cavities were formed on the labial surfaces and filled with Biodentine. The teeth were divided into seven groups, each consisting of 10 teeth. The specimens were prepared by applying the composite resin on the upper side after different setting times. To evaluate shear bond strength, 210 acrylic resin blocks with central grooves were prepared, and the grooves were filled with Biodentine. The acrylic resin blocks were divided into seven groups of 30 specimens each, and the specimens were prepared by applying the composite resin on the upper side after different setting times. In samples with setting time of 24 hours or longer period, the microleakage between composite resin and Biodentine was reduced significantly while the shear bond strength increased to offset the polymerization shrinkage of the composite resin. Setting Biodentine for more than 24 hours before composite resin restoration would lead to more favorable clinical result.

Dual-Band Six-Port Direct Conversion Receiver with I/Q Mismatch Calibration Scheme for Software Defined Radio (Software Defined Radio를 위한 I/Q 부정합 보정 기능을 갖는 이중 대역 Six-Port 직접변환 수신기)

  • Moon, Seong-Mo;Park, Dong-Hoon;Yu, Jong-Won;Lee, Moon-Que
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.6
    • /
    • pp.651-659
    • /
    • 2010
  • In this paper, a new six-port direct conversion receiver for high-speed multi-band multi-mode wireless communication system such as software defined radio(SDR) is proposed. The designed receiver is composed of two CMOS four-port BPSK receivers and a dual-band one-stage polyphase filter for quadrature LO signal generation. The four-port BPSK receiver, implemented in 0.18 ${\mu}m$ CMOS technology for the first time in microwave-band, is composed of two active combiners, an active balun, two power detector, and an analog decoder. The proposed polyphase filter adopt type-I architecture, one-stage for reduction of the local oscillator power loss, and LC resonance structure instead of using capacitor for dual-band operation. In order to extent the operation RF bandwidth of the proposed six-port receiver, we include I/Q phase and amplitude calibration scheme in the six-port junction and the power detector. The calibration range of the phase and amplitude mismatch in the proposed calibration scheme is 8 degree and 14 dB, respectively. The validity of the designed six-port receiver is successfully demonstrated by modulating M-QAM, and M-PSK signal with 40 Msps in the two-band of 900 MHz and 2.4 GHz.

A 2.4 GHz Bio-Radar System with Small Size and Improved Noise Performance Using Single Circular-Polarized Antenna and PLL (하나의 원형 편파 안테나와 PLL을 이용하여 소형이면서도 개선된 잡음 성능을 갖는 2.4 GHz 바이오 레이더 시스템)

  • Jang, Byung-Jun;Park, Jae-Hyung;Yook, Jong-Gwan;Moon, Jun-Ho;Lee, Kyoung-Joung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.12
    • /
    • pp.1325-1332
    • /
    • 2009
  • In this paper, we design a 2.4 GHz bio-radar system that can detect human heartbeat and respiration signals with small size and improved noise performance using single circular-polarized antenna and phase-locked loop. The demonstrated bio-radar system consists of single circular-polarized antenna with $90^{\circ}$ hybrid, low-noise amplifier, power amplifier, voltage-controlled oscillator with phase-locked loop circuits, quadrature demodulator and analog circuits. To realize compact size, the printed annular ring stacked microstrip antenna is integrated on the transceiver circuits, so its dimension is just $40\times40mm^2$. Also, to improve signal-to-noise-ratio performance by phase noise due to transmitter leakage signal, the phase-locked loop circuit is used. The measured results show that the heart rate and respiration accuracy was found to be very high for the distance of 50 cm without the additional digital signal processing.

2N-Point FFT-Based Inter-Carrier Interference Cancellation Alamouti Coded OFDM Method for Distributed Antennas systems (분산안테나 시스템을 위한 2N-점 고속푸리에변환 기반 부반송파 간 간섭 자체제거 알라무티 부호화 직교주파수분할다중화 기법)

  • Kim, Bong-Seok;Choi, Kwonhue
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.12
    • /
    • pp.1030-1038
    • /
    • 2013
  • The proposed Alamouti coded OFDM effectively cancels Inter Carrier Interference (ICI) due to frequency offset between distributed antennas. The conventional Alamouti coded OFDM schemes to mitigate ICI utilize N-point Inverse Fast Fourier Transform/Fast Fourier Transform (IFFT/FFT) operations for OFDM modulation and demodulation processes with total N subcarriers. However, the performance degrades because ICI is also repeated in N periods due to the property of N-point IFFT/FFT operation. In order to avoid this problem, null data are used at the subcarriers with large ICI and thus, data rate decreases. The proposed scheme employs 2N-point IFFT/FFT instead of N-point IFFT/FFT in order to increase sampling rate. By increasing sampling rate, the amount of interference significantly decreases because the period of ICI also increases. The proposed scheme increases the data rate and improves the performance by reducing amount of ICI and the number of null-data. Furthermore, the gain of the performance and data rate of the proposed scheme is significant with higher modulation such as 16-Quadarature Amplitude Modulation (QAM) or 64-QAM.

Multi-Point Optical Fiber Grating Strain Sensor System (광섬유 격자 다중화 스트레인 센서 시스템)

  • Lee, Yong-Wook;Jung, Jae-Hoon;Chung, Seung-Hwan;Lee, Byoung-Ho;Kim, Nam-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.2
    • /
    • pp.147-151
    • /
    • 2001
  • An optical fiber sensor is capable of nondestructive measurement of a structure and it has an advantage of the immunity to electromagnetic interference because light is not affected by electromagnetic wave. In addition, if optical fibers are buried in an object like a concrete, this sensor tan analyze defects and physical status of the object without disassembling it. Especially, the fiber Bragg grating sensor is a promising optical fiber sensor capable of nondestructive test of such an object. A fiber Bragg grating has the characteristics of reflecting or blotting light of a specific wavelength. If we apply physical quantity like strain to the fiber Bragg grating, the center wavelength of the reflected light is shifted and then we can find the physical quantity applied to the fiber Bragg grating by measuring the center wavelength shift of the reflected light. The fiber Bragg grating sensor capable ot static and dynamic strain measurement is being used in health-monitoring of buildings, structures, etc. Recently increasing is interest in dynamic strain measurement inevitable to the civil structures such as roads and bridges. In this study we implemented the optical fiber sensor system which can measure dynamic strain at multiple points using Fabry-Perot wavelength demodulation. And we measured the static and dynamic strain using this sensor system with a test structure(cantilever). Measurement results were similar to those obtained with the conventional electrical measurement methods.

  • PDF

A Design of Software Receiver for GNSS Signal Processing

  • Choi, Seung-Hyun;Kim, Jae-Hyun;Shin, Cheon-Sig;Lee, Sang-Uk;Kim, Jae-Hoon
    • Journal of Satellite, Information and Communications
    • /
    • v.2 no.2
    • /
    • pp.48-52
    • /
    • 2007
  • Recently, the research of GPS receiver which uses the Software-Defined Radio(SDR) technique is being actively proceeded instead of traditional hardware-based receiver. The software-based GPS receiver indicates that the signal acquisition and tracking treated by the hardware-based platform are processed as the software technique through a microprocessor. In this paper, GPS software receiver is designed by using SDR technique and then the signal acquisition, tracking, and the navigation message decoding parts are verified through the PC-based simulation. Moreover, the efficient algorithms are developed about the signal acquisition and tracking parts in order to obtain the accurate pseudorange. Finally, the pseudorange is calculated through the relative channel delay received through the different satellite of L1 frequency band. GPS software receiver proposed in this paper will be included in the element of GPS/Galileo complex system of development target and will provide not only the method that verifies the performance for Galileo Sensor Station standard but also usability by providing various debugging environments.

  • PDF

Electrical Characteristics Measurement of Eddy Current Testing Instrument for Steam Generator in NPP (원전 증기발생기 와전류검사 장치의 전기적 특성 측정)

  • Lee, Hee-Jong;Cho, Chan-Hee;Yoo, Hyun-Joo;Moon, Gyoon-Young;Lee, Tae-Hun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.465-471
    • /
    • 2013
  • A steam generator in nuclear power plant is a heatexchager which is used to convert water into steam from heat produced in a nuclear reactor core, and the steam produced in steam generator is delivered to the turbine to generate electricity. Because of damage to steam generator tubing may impair its ability to adequately perform required safety functions in terms of both structural integrity and leakage integrity, eddy current testing is periodically performed to evaluate the integrity of tubes in steam generator. This assessment is normally performed during a reactor refueling outage. Currently, the eddy current testing for steam generator of nuclear power plant in Korea is performed in accordance with KEPIC & ASME Code requirements, the eddy current testing system is consists of remote data acquisition unit and data analysis program to evaluate the acquired data. The KEPIC & ASME Code require that the electrical properties of remote data acquisition unit, such as total harmonic distortion, input & output impedance, amplifier linearity & stability, phase linearity, bandwidth & demodulation filter response, analog-to-digital conversion, and channel crosstalk shall be measured in accordance with the KEPIC & ASME Code requirements. In this paper, the measurement requirements of electrical properties for eddy current testing instrument described in KEPIC & ASME Code are presented, and the measurement results of newly developed eddy current testing instrument by KHNP(Korea Hydro & Nuclear Power Co., LTD) are presented.

Antioxidant Activity, Total Phenolics, Vitamin C and Sugar Content during Fruit Ripening of Five Different Jujube Cultivars (대추(Zyziphus jujuba) 품종별 성숙정도에 따른 항산화 활성, 총페놀 함량, 비타민 C 함량 및 당함량)

  • Park, Youngki;Kim, Jae-Hee
    • Korean Journal of Plant Resources
    • /
    • v.29 no.5
    • /
    • pp.539-546
    • /
    • 2016
  • The aim of this study was to analyze antioxidant activity, total phenolics, and vitamin C content in unripe and ripe jujube cultivar and to investigate correlation between antioxidant and chemical constituents including total phenolics and vitamin C. The antioxidant activity was measured by the DPPH radical scavenging activity, ABTS radical scavenging activity, and reducing power. Although, the weight, diameter and soluble solids of Zyziphus jujuba fruit were increased with the progress of ripening, antioxidant activity and total phenolics were decrease during ripening. The highest free-radical scavenging activity (at 2.5 ㎎/㎖) and reducing power (at 1 ㎎/㎖) in fruit were 81.75% (Bokjo, unripe) and 0.80 (Mudeung, unripe), respectively. The highest total phenolic content in unripe fruit of Mudeung was 62.50 ㎍/g. A linear correlation (r=0.911) was shown between DPPH radical scavenging activity and total phenolic content.