• Title/Summary/Keyword: 복사휘도

Search Result 47, Processing Time 0.02 seconds

Infrared Signature Analysis on a Flat Plate by Using the Spectral BRDF Data (파장별 BRDF 데이터를 이용한 평판의 적외선 복사휘도 특성 분석)

  • Choi, Jun-Hyuk;Kim, Dong-Geon;Kim, Jung-Ho;Kim, Tae-Kuk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.6
    • /
    • pp.577-585
    • /
    • 2010
  • This paper is a part of developing a software that predicts the infrared signal emitted from a ground object by considering solar irradiation. The radiance emitted from a surface can be calculated by using the temperature and optical characteristics of the surface object. The bidirectional reflectance distribution function (BRDF) is defined as the ratio of reflected radiance to incident irradiance. It is a very important surface reflection property that decides the reflected radiance from the object. In this paper, the spectral radiance received by a remote sensor over the mid-wave infrared(MWIR), and the long-wave infrared(LWIR) regions are computed and compared each other for several different materials. The results show that the optical surface properties such as the BRDF and the emissivity of the object surface can play a major role in generating the infrared signatures of various objects, and the largest infrared signal may reach up to 10 times the smallest one when the infrared signals obtained from a flat plate with different surface conditions under the sun light.

Improvement of Spatial Radiance Uniformity of Small Integrating Spheres (소형 적분구의 공간 복사 휘도 균일도 향상 연구)

  • Yong Shim Yoo;Dong Joo Shin;Bong Hak Kim
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.5
    • /
    • pp.202-209
    • /
    • 2023
  • A KRISS-type small integrating sphere with a high spatial radiance uniformity was made using pressed polytetrafluoroethylene (PTFE) and a reflective rod to calibrate the spectral radiance responsivity of absolute radiant thermometers. The spatial radiance uniformity of the KRISS-type small integrating sphere was ±0.009%, five times higher than the best value reported by foreign national metrology institutions thus far. In addition, we improved the spatial radiance uniformity of a commercial sintered PTFE integrating sphere by a factor of 10.

Simulation of TOA Visible Radiance for the Ocean Target and its Possible use for Satellite Sensor Calibration (해양 표적을 이용한 대기 상단 가시영역에서의 복사휘도 모의와 위성 센서 검보정에의 활용 가능성 연구)

  • Kim, Jung-Gun;Sohn, Byung-Ju;Chung, Eui-Seok;Chun, Hyoung-Wook;Suh, Ae-Sook;Kim, Kum-Lan;Oh, Mi-Lim
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.6
    • /
    • pp.535-549
    • /
    • 2008
  • Vicarious calibration for the satellite sensor relies on simulated TOA (Top-of-Atmosphere) radiances over various targets. In this study, TOA visible radiance was calculated over ocean targets which are located in five different regions over the Indian and Pacific ocean, and its possible use for the satellite sensor calibration was examined. TOA radiances are simulated with the 6S radiative transfer model for the comparison with MODIS/Terra and SeaWiFS measurements. Geometric angles and sensor characteristics of the reference satellites were taken into account for the simulation. AOT (Aerosol Optical Thickness) from MODIS/Terra, pigment concentrations from Sea WiFS, and ozone amount from OMI measurements were used as inputs to the model. Other atmospheric input parameters such as surface wind and total column water vapor were taken from NCEP/NCAR reanalysis data. The 5-day averaged radiances over all targets show that the percent differences between simulated and observed radiances are within about ${\pm}5%$ in year 2005, indicating that the calculated radiances are in good agreement with satellite measurements. It has also been shown that the algorithm can produce the SeaWiFS radiances within about ${\pm}5%$ uncertainty range. It has been suggested that the algorithm can be used as a tool for calibrating the VIS bands within about 5% uncertainty range.

Design and Implementation of a Radiative Temperature Measurement System for a Flash Light (섬광의 복사온도 측정 장치의 설계 및 제작)

  • Jin, Jung-Ho;Han, Seungoh;Yang, Hee Won;Park, Seung-Man
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.1
    • /
    • pp.30-37
    • /
    • 2015
  • The design and implementation of a radiative temperature measurement system for a flash light are carried out. Since a massive amount of energy is emitted within a very short time, it is impossible to measure the temperature of a flash with a conventional method. It is also irrelevant to measure one with an optical noncontact method. In this paper, a radiative temperature measurement system using the ratio of spectral radiances over mid- and long-wavelength infrared (IR) is designed and implemented. The implemented system utilizes optical bandpass filters to divide the wavelengths within the mid- and long-wavelength IR ranges, and pyroelectric IR detectors to measure the incident optical power of each wavelength-divided channel. It is shown that the measured radiative temperature of a flash is in the range of 1393 to 1455 K. This temperature-measurement system can be utilized to obtain information about the spectral radiance of a flash as a light source, which is of crucial importance to approaching the modeling and simulation of the various effects of a flash.

Evaluation of Blue Light Hazards in LED Lightings (LED 조명에 대한 청색광 위험 평가)

  • Jung, Myoung Hoon;Yang, Seok-Jun;Yuk, Ju Sung;Oh, Sang-Young;Kim, Chang-Jin;Lyu, Jungmook;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.293-300
    • /
    • 2015
  • Purpose: To evaluate blue light hazards of LED lightings in an optical store with blue light radiance used as the quantitative indicators of photobiological hazard. Methods: The spectral radiance of each LED lightings was measured, and blue-light radiance and the corresponding maximum exposure time were calculated. Then each LED lighting was classified according to the risk group from IEC 62471 standard. Results: The yellow LED lightings used in showcases and white LED lightings used on ceilings and logo were classified into risk group RG0. But the white LED lightings used on showcases were classified into risk group RG1. The blue light radiances of white LED lightings used in showcases are dozens of times larger than that of fluorescent lamp. Conclusions: Using the value of the blue light radiance could quantitatively express the blue light hazard to various lightings. It was confirmed that white LED lightings for the showcases had high blue light hazards because of their high luminance and color temperature. Therefore, when replacing lightings in optical shop it is necessary to select the appropriate brightness and color temperature for eye health in the long term.

Bias Characteristics Analysis of Himawari-8/AHI Clear Sky Radiance Using KMA NWP Global Model (기상청 전구 수치예보모델을 활용한 Himawari-8/AHI 청천복사휘도 편차 특성 분석)

  • Kim, Boram;Shin, Inchul;Chung, Chu-Yong;Cheong, Seonghoon
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_1
    • /
    • pp.1101-1117
    • /
    • 2018
  • The clear sky radiance (CSR) is one of the baseline products of the Himawari-8 which was launched on October, 2014. The CSR contributes to numerical weather prediction (NWP) accuracy through the data assimilation; especially water vapor channel CSR has good impact on the forecast in high level atmosphere. The focus of this study is the quality analysis of the CSR of the Himawari-8 geostationary satellite. We used the operational CSR (or clear sky brightness temperature) products in JMA (Japan Meteorological Agency) as observation data; for a background field, we employed the CSR simulated using the Radiative Transfer for TOVS (RTTOV) with the atmospheric state from the global model of KMA (Korea Meteorological Administration). We investigated data characteristics and analyzed observation minus background statistics of each channel with respect to regional and seasonal variability. Overall results for the analysis period showed that the water vapor channels (6.2, 6.9, and $7.3{\mu}m$) had a positive mean bias where as the window channels(10.4, 11.2, and $12.4{\mu}m$) had a negative mean bias. The magnitude of biases and Uncertainty result varied with the regional and the seasonal conditions, thus these should be taken into account when using CSR data. This study is helpful for the pre-processing of Himawari-8/Advanced Himawari Imager (AHI) CSR data assimilation. Furthermore, this study also can contribute to preparing for the utilization of products from the Geo-Kompsat-2A (GK-2A), which will be launched in 2018 by the National Meteorological Satellite Center (NMSC) of KMA.

Characteristics of Photodetectors for spectral radiance measurements (분광복사휘도 측정용 광검출기의 특성 평가)

  • 서정철;박승남;김봉학
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.5
    • /
    • pp.376-381
    • /
    • 2001
  • We have fabricated a spectroadiometric system to measure spectral radiance of optical sources and evaluated its characteristics such as spectral responsivity, nonlinearity, and so on. The measurement system with PMT, Si, InGaAs, and IR-enhanced InGaAs detectors has shown a good linearity and a wide spectral responsivity of 250∼2500 nm. This spectroradiometric system will be used as the primary national standard system of spectral radiance measurements.

  • PDF

Infrared Characteristics of Some Flash Light Sources (섬광의 적외선 특성 연구)

  • Lim, Sang-Yeon;Park, Seung-Man
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.1
    • /
    • pp.18-24
    • /
    • 2016
  • To effectively utilize a flash and predict its effects on an infrared device, it is essential to know the infrared characteristics of the flash source. In this paper, a study of the IR characteristics of flash light sources is carried out. The IR characteristics of three flash sources, of which two are combustive and the other is explosive, are measured with an IR characteristic measurement system over the middle- and long-wavelength infrared ranges. From the measurements, the radiances over the two IR ranges and the radiative temperatures of the flashes are extracted. The IR radiance of flash A is found to be the strongest among the three, followed by those of sources C and B. It is also shown that the IR radiance of flash A is about 10 times stronger than that of flash B, even though these two sources are the same type of flash with the same powder. This means that the IR radiance intensity of a combustive flash source depends only on the amount of powder, not on the characteristics of the powder. From the measured radiance over MWIR and LWIR ranges for each flashes, the radiative temperatures of the flashes are extracted by fitting the measured data to blackbody radiance. The best-fit radiative temperatures (equivalent to black-body temperatures) of the three flash sources A, B, and C are 3300, 1120, and 1640 K respectively. From the radiance measurements and radiative temperatures of the three flash sources, it is shown that a combustive source radiates more IR energy than an explosive one; this mean, in turn, that the effects of a combustive flash on an IR device are more profound than those of an explosive flash source. The measured IR radiances and radiative temperatures of the flash sources in this study can be used to estimate the effects of flashes on various IR devices, and play a critical role for the modeling and simulation of the effects of a flash source on various IR devices.

Development of the GOCI Radiometric Calibration S/W (정지궤도 해양위성(GOCI) 복사보정 S/W 개발)

  • Cho, Seong-Ick;Ahn, Yu-Hwan;Han, Hee-Jeong;Ryu, Joo-Hyung
    • Proceedings of the KSRS Conference
    • /
    • 2009.03a
    • /
    • pp.167-171
    • /
    • 2009
  • 정지궤도에서는 세계 최초의 해양관측위성으로 개발된 정지궤도 해양위성(GOCI, Geostationary Ocean Color Imager)은 통신해양기상위성(COMS, Communication, Ocean and Meterological Satellite)의 탑재체로서 2009년말 발사 예정이다. 정지궤도 해양위성의 복사보정은 센서의 전기적 특성에 의한 잡음을 제거하기 위한 암흑전류 교정(Dark Current Correction)을 먼저 수행한 다음, 주운영지상국인 해양위성센터(KOSC, Korea Ocean Satellite Center)에서 수신된 위성의 원시자료의 Digital Number(DN)를 실제 해양원격탐사에서 이용하는 물리량인 복사휘도(Radiance, $W/m^2/{\mu}m/sr$)로 변환하는 복사보정을 수행한다. 정확도 높은 복사보정을 수행하기 위해서는 기준광원의 복사휘도와 센서의 물리적 특성을 정확하게 알아야 한다. 정지궤도 해양위성 궤도상 복사보정(on-orbit radiometric calibration)에서는 태양이 기준광원이기 때문에, 기준 태양복사모델(Thuillier 2004 Solar Irradiance Model)에서 지구-태양간 거리 변화(1년 주기)를 보정한 태양의 방사도 (Irradiance)를 이용하고, 태양입사각에 대한 태양광 확산기의 감쇄 특성 변화를 고려하여 센서에 입력되는 복사휘도를 계산한다. 센서의 물리적 특성으로 인한 복사보정의 오차를 줄이기 위해 우주방사선 및 우주먼지(space debris)로 인해 위성 운용기간 중 그 특성이 저하되는 태양광 확산기(solar Diffuser)의 특성변화를 모니터링하기 위한 DAMD(Diffuser Aging Monitoring Device)를 이용한다. 정지궤도 해양위성 주관운영기관인 한국해양연구원의 해양위성센터에서는 정지궤도 해양위성 복사보정을 수행하기 위한 S/W를 통신해양기상위성 자료처리시스템 개발사업의 일환으로 개발하였으며, 관련 성능 시험을 수행하고 있다.

  • PDF

A Preliminary Analysis on the Radiometric Difference Across the Level 1B Slot Images of GOCI-II (GOCI-II Level 1B 분할영상 간의 복사 편차에 대한 초기 분석)

  • Kim, Wonkook;Lim, Taehong;Ahn, Jae-hyun;Choi, Jong-kuk
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_2
    • /
    • pp.1269-1279
    • /
    • 2021
  • Geostationary Ocean Color Imager II (GOCI-II), which are now operated successfully since its launch in 2020, acquires local area images with 12 Level 1B slot images that are sequentially acquired in a 3×4 grid pattern. The boundary areas between the adjacent slots are prone to discontinuity in radiance, which becomes even more clear in the following Level 2 data, and this warrants the precise analysis and correction before the distribution. This study evaluates the relative radiometric biases between the adjacent slots images, by exploiting the overlapped areas across the images. Although it is ideal to derive the statistics from humongous images, this preliminary analysis uses just the scenes acquired at a specific time to understand its general behavior in terms of bias and variance in radiance. Level 1B images of February 21st, 2021 (UTC03 = noon in local time) were selected for the analysis based on the cloud cover, and the radiance statistics were calculated only with the ocean pixels. The results showed that the relative bias is 0~1% in all bands but Band 1 (380 nm), while Band 1 exhibited a larger bias (1~2%). Except for the Band 1 in slot pairs aligned North-South, biases in all direction and in all bands turned out to have biases in the opposite direction that the sun elevation would have caused.