• Title/Summary/Keyword: 복사영역

Search Result 305, Processing Time 0.02 seconds

Simulation of TOA Visible Radiance for the Ocean Target and its Possible use for Satellite Sensor Calibration (해양 표적을 이용한 대기 상단 가시영역에서의 복사휘도 모의와 위성 센서 검보정에의 활용 가능성 연구)

  • Kim, Jung-Gun;Sohn, Byung-Ju;Chung, Eui-Seok;Chun, Hyoung-Wook;Suh, Ae-Sook;Kim, Kum-Lan;Oh, Mi-Lim
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.6
    • /
    • pp.535-549
    • /
    • 2008
  • Vicarious calibration for the satellite sensor relies on simulated TOA (Top-of-Atmosphere) radiances over various targets. In this study, TOA visible radiance was calculated over ocean targets which are located in five different regions over the Indian and Pacific ocean, and its possible use for the satellite sensor calibration was examined. TOA radiances are simulated with the 6S radiative transfer model for the comparison with MODIS/Terra and SeaWiFS measurements. Geometric angles and sensor characteristics of the reference satellites were taken into account for the simulation. AOT (Aerosol Optical Thickness) from MODIS/Terra, pigment concentrations from Sea WiFS, and ozone amount from OMI measurements were used as inputs to the model. Other atmospheric input parameters such as surface wind and total column water vapor were taken from NCEP/NCAR reanalysis data. The 5-day averaged radiances over all targets show that the percent differences between simulated and observed radiances are within about ${\pm}5%$ in year 2005, indicating that the calculated radiances are in good agreement with satellite measurements. It has also been shown that the algorithm can produce the SeaWiFS radiances within about ${\pm}5%$ uncertainty range. It has been suggested that the algorithm can be used as a tool for calibrating the VIS bands within about 5% uncertainty range.

Development Trend of Japanese Optical Payloads (일본의 광학탑재체(지상/해양 관측용) 개발 경향)

  • Myung, Hwan-Chun
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.8 no.2
    • /
    • pp.65-75
    • /
    • 2010
  • In 2014, Japan is scheduled to launch GCOM(Global Change Observation Mission)-C for the global change observation mission, where SGLI(Second-generation Global Imager) is planned for optical multi-channel observation ofa radiation budget and a carbon cycle. Depending on the spectral channels, SGLI consists ofS GLI-VNR(Visible Near IR) and SGLI-IRS(IR Scanning). Their main design schemes are mostly based upon those ofthe previous instruments ever developed in Japan, which is intended to reduce the development risk for the advanced performance. Accordingly, for the better understanding ofSG LI, the paper reviews the history oft he Japanese optical payloads from two different views: VNR and IR. Through the review, a comparison among the Japanese optical instruments is made to distinguish the development trend toward SGLI ofGC OM-C.

  • PDF

Study on the LOWTRAN7 Simulation of the Atmospheric Radiative Transfer Using CAGEX Data. (CAGEX 관측자료를 이용한 LOWTRAN7의 대기 복사전달 모의에 대한 조사)

  • 장광미;권태영;박경윤
    • Korean Journal of Remote Sensing
    • /
    • v.13 no.2
    • /
    • pp.99-120
    • /
    • 1997
  • Solar radiation is scattered and absorbed atmospheric compositions in the atmosphere before it reaches the surface and, then after reflected at the surface, until it reaches the satellite sensor. Therefore, consideration of the radiative transfer through the atmosphere is essential for the quantitave analysis of the satellite sensed data, specially at shortwave region. This study examined a feasibility of using radiative transfer code for estimating the atmospheric effects on satellite remote sensing data. To do this, the flux simulated by LOWTRAN7 is compared with CAGEX data in shortwave region. The CAGEX (CERES/ARM/GEWEX Experiment) data provides a dataset of (1) atmospheric soundings, aerosol optical depth and albedo, (2) ARM(Aerosol Radiation Measurement) radiation flux measured by pyrgeometers, pyrheliometer and shadow pyranometer and (3) broadband shortwave flux simulated by Fu-Liou's radiative transfer code. To simulate aerosol effect using the radiative transfer model, the aerosol optical characteristics were extracted from observed aerosol column optical depth, Spinhirne's experimental vertical distribution of scattering coefficient and D'Almeida's statistical atmospheric aerosols radiative characteristics. Simulation of LOWTRAN7 are performed on 31 sample of completely clear days. LOWTRAN's result and CAGEX data are compared on upward, downward direct, downward diffuse solar flux at the surface and upward solar flux at the top of the atmosphere(TOA). The standard errors in LOWTRAN7 simulation of the above components are within 5% except for the downward diffuse solar flux at the surface(6.9%). The results show that a large part of error in LOWTRAN7 flux simulation appeared in the diffuse component due to scattering mainly by atmispheric aerosol. For improving the accuracy of radiative transfer simulation by model, there is a need to provide better information about the radiative charateristrics of atmospheric aerosols.

Integrated Radiometric Signal Modeling for High Resolution Earth Observation Satellite Camera (고해상도 지구관측위성 카메라의 복사신호량에 대한 통합적 모델링)

  • Jang, Hong-Sul;Jung, Dae-Jun;Youk, Young-Chun;Lee, Seung-Hoon
    • Aerospace Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.82-87
    • /
    • 2008
  • In this study, the radiometric signal modeling is performed for the high resolution earth observation system in visible spectral range from space. The medeling includes solar radiation as a source of the radiometric energy, atmosphere and surface albedo of earth, and the spaceborne camera characteristics for the integrated modeling. The final output of the radiometric modeling is the number of electron produced by the detector of electro-optical camera.

  • PDF

Characteristics of Photodetectors for spectral radiance measurements (분광복사휘도 측정용 광검출기의 특성 평가)

  • 서정철;박승남;김봉학
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.5
    • /
    • pp.376-381
    • /
    • 2001
  • We have fabricated a spectroadiometric system to measure spectral radiance of optical sources and evaluated its characteristics such as spectral responsivity, nonlinearity, and so on. The measurement system with PMT, Si, InGaAs, and IR-enhanced InGaAs detectors has shown a good linearity and a wide spectral responsivity of 250∼2500 nm. This spectroradiometric system will be used as the primary national standard system of spectral radiance measurements.

  • PDF

The Analysis of the T-shaped Microstripline-Fed Printed Slot Antenna with Unidirectional Radiation (한방향 복사특성을 갖는 T-모양 급전선 마이크로스트립 슬롯 안테나의 해석)

  • Jang, Yong-Woong;Oh, Dong-Jin
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.4
    • /
    • pp.103-109
    • /
    • 1999
  • In this paper, we proposed to a new structure of T-shaped fed microstrip slot antenna using 2-layers dielectric material with a directional radiation characteristic. When the slot antenna of bi-directional radiation want to radiate only one direction, the reflector must be set up, but this antenna does'nt need set up reflector. T-shaped microstrip feed line is proposed for a better impedance matching to the microstrip slot antenna in a various range of slot widths. It was also found that the bandwidth of this antenna is proportional to the slot width. It was also found that the radiation resistance of this feed line structure is quite constant and low regardless to the slot width. We also analyzed this antenna by using the FDTD method, and calculating waves and electric field distribution in the time domain. we also are calculated return loss, VSWR, and radiation pattern in the frequency domain by Fourier transforming the time domain results, respectively. From the measured results, bandwidth was 34.8% in the center frequency. These results were in relatively good accordance with the calculated values.

  • PDF

Analysis of Wideband Microstrip Slot Antenna with Cross-shaped Feedline using 2-layer Dielectrics (2층 유전체를 사용한 십자형 급전선을 갖는 광대역 마이크로스트립 슬롯 안테나의 해석)

  • 장용웅;신호섭
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.37 no.2
    • /
    • pp.69-74
    • /
    • 2000
  • The bandwidth of microstrip slot antenna with T-shaped feed line was a wider than one of the conventional feeding structure. When the slot antenna with bi-directional radiator wants to radiate only one direction, the reflector must be set up seperately. But this antenna doesn't need set up reflector. And then we proposed to a new method of a directional slot radiator with a cross-shaped feedline including the reflector using 2-layers dielectric materials. It is calculated waves and electric field distribution in the time domain by using FDTD method. We also are calculated return loss, VSWR, input impedance, and radiation pattern in the frequency domain by Fourier transforming the time domain results, respectively. It was found that the bandwidth of this antenna changes as length($\I_s$) and width($\W_s$) of slot, length of the horizontal feedline($\I_d$), length of the vertical feedline($\I_u$) and offset sensitively. After optimizing the parameters of design, the maximum bandwidth was measured as 1,850MHz at the center frequency 2.5 GHz.

  • PDF

Establishment of Comparison Calibration Equipment for Infrared-radiation Thermometers Below ℃ (℃ 이하 적외선 복사온도계 비교 교정장치 구축)

  • Yoo, Yong Shim;Kim, Bong-Hak
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.2
    • /
    • pp.70-76
    • /
    • 2018
  • Comparison calibration equipment for infrared-radiation thermometers below $0^{\circ}C$ has been established, using a TRT2 (transfer radiation thermometer 2, HEITRONICS) as a transfer standard and an ME30 (Model: ME30, HEITRONICS) as a variabletemperature blackbody. The TRT2 was calibrated using three fixed points (Ice ($0.01^{\circ}C$), In ($156.5985^{\circ}C$), and Sn ($231.928^{\circ}C$)) and the Planckian Sakuma-Hattori equation, and including the interpolation and extrapolation errors at $-50^{\circ}C$ in the uncertainty. The pneumatic lid is installed upon opening of the ME30 and is opened for only 30 seconds for measuring the radiation temperature, which prevents formation of ice in the ME30 and also reduces the calibration time to half. The farther away from the $0{\sim}232^{\circ}C$ region, the larger the uncertainty of the comparison calibration equipment becomes. The expanded uncertainty of the comparison calibration equipment was estimated as 0.26 K at $-20^{\circ}C$.