The purpose of this study was to evaluate the influence of sprue joint form on castability in dental prosthetics. The researcher carried out experimental study according to the type was divided by sprue joint form. Therefore type A was made thicken than sprue diameter of type B and type C was made it conversely. The results were as follows: 1. In the order of castability, type C(87.8%) was first and then type A(87.0%) and type B(79.2%) was last. However there was no significant difference statistically. 2. If reservior was located at the correct position and in sufficient size, internal shrinkage porosity in the casting bodies were not generated in the type of all. 3. At the reservoir, internal shrinkage porosity was generated first in type A, followed by type Band type C in the order named. Although it gives no impact on casting body, porosity seems to appear the least when it's produced in the form of type C.
하악 제 1대구치에 티타늄과 지르코니아 소재의 기성 지대주와 맞춤형 지대주를 이용해 지르코니아 크라운으로 수복한 경우를 3차원 유한요소법을 통해 응력 분포를 분석해 보고, 피로 파절 강도 및 파절 형태를 고찰해 보았다. 정상교합자의 CT scan을 재구성한 하악골 모형상에 제 1대구치 임플란트 지지 지르코니아 크라운으로 수복한 6가지 유한요소 모형을 제작하고, 협측 교두 중앙에 수직과 30도 각도로 100 N의 하중을 가하는 조건으로 응력분포를 분석하였다. 현재 임상적으로 사용되고 있는 4가지 지대주를 이용하여, 군당 10개의 시편을 제작하고, ISO 14801에 따라 피로파절 실험을 실시하였다. 지대주나 고정체의 재질에 따른 응력분포의 차이는 없었고 형태에 따른 응력크기의 차이만 보였다. 맞춤형 지대주 군이 전반적으로 낮은 크라운 응력을 나타내었으며, 지대주 일체형 지르코니아 임플란트는 계면 골조직의 응력이 가장 낮게 나타났다. 피로수명의 평균값은 7군이 가장 높았고, 1군, 2군, 3군의 순서로 낮게 나타났으며(P<0.05), 기성 지대주 군은 피로수명의 편차가 적게 나타났다. 구치부의 임플란트 수복 시에는 맞춤형 지대주의 사용이 상부 보철물의 파절저항성 향상에 유리하며, 심미적 요구도가 높은 경우에는 고정체와의 접합부를 티타늄으로 제작한 지르코니아 맞춤형 지대주의 사용을 고려해 볼 만 하다.
이 연구의 목적은 유구치를 재현한 인공치를 대상으로 인접면 복합레진 수복 시 매트릭스 시스템에 따른 인접면의 외형, 접촉면의 크기 및 수복 전과 후의 부피 차이를 비교해 보는 것이다. 네 가지 종류의 인공치에 Circumferential 매트릭스 시스템에 해당하는 Tofflemire Matrix System과 Sectional 매트릭스 시스템에 해당하는 Palodent V3 Sectional Matrix System, myJunior Kit를 이용하여 복합레진을 수복하고 3D 모델링 과정을 거쳐 분석되었다. Sectional 매트릭스 시스템을 사용한 경우에서 오목한 인접면 외형이 형성될 확률이 높았으며 더 큰 접촉 면적과 부피가 형성되었다. 이는 Sectional 매트릭스 시스템에 사용되는 매트릭스 밴드의 완전 연질(Dead soft) 특성에 의한 변형으로 인해 접촉점 주변으로 과량의 레진이 적용될 수 있기 때문이다. 게다가 Sectional 매트릭스 시스템에 포함된 고무 웨지가 매트릭스 밴드를 와동에 잘 적합 시키지 못할 가능성이 있다. 따라서 이번 연구의 결과를 바탕으로 유구치 인접면을 Sectional 매트릭스 시스템을 이용해 복합레진 수복하는 경우, 형태학적 관점을 고려한 신중한 사용이 요구된다.
목적: 상악 구치부에서 자연치와 임플란트 보철시, 보철치관/고정체 비율에 따른 응력분포 양상을 비교하고자 했다. 재료 및 방법: 자연치 모델의 경우는 획득한 3차원 인체모델을 상악 좌측 제2소구치 및 제 1대구치가 포함된 상악골을 Box 형태의 3차원 유한요소모델로 변환하였고, 임플란트 모델은 3차원 인체모델에서 치아 부분을 제거하고 동일 부위에 임플란트 모델을 연결하는 과정을 거쳐서 임플란트가 삽입된 유한요소모델을 구성하였다. 치관/고정체 비율을 0.7:1, 1:1, 1.25:1이 되도록 골수준 (bone level)을 조정하였으며 각 모델의 치관 부위에 300 N의 수직 하중과 수평하중을 각각 가했다. 결과: 1. 모든 하중 조건하에서 자연치와 임플란트 모두에서 피질골과 인접하는 경부에 응력이 집중되는 양상을 보였다. 2. 치관/치근 (고정체) 비가 증가함에 따라 자연치와 임플란트 모두에서 교합면에 수직적 하중을 가한 경우에는 응력의 변화가 뚜렷하지 않았으나, 수평적 하중을 가한 경우에서는 응력이 증가하는 양상을 보였다. 3. 자연치의 경우에 치관/치근비가 증가함에 따라 splinting이 응력감소 효과를 보였고, 임플란트의 경우에는, 치관/고정체 비가 증가함에 따라 splinting이 수직 하중조건에 응력감소효과를 보였으나, 중심에서 벗어난 하중조건에는 최대응력이 오히려 증가하는 양상을 보였다. 4. 임플란트의 경우, 치관/고정체 비가 증가함에 따라 splinting이 수평하중조건 4에서 뚜렷한 응력감소 효과를 보이나, 수평 하중조건 5에서는 응력감소 효과가 감소되고, 특히 치관/고정체 비가 1.25:1인 경우에서는 오히려 응력의 증가를 보였다. 결론: 임플란트 보철물은 치관/고정체 비가 커질수록 더 큰 응력을 받게 되고, splinting의 효과도 감소하게 된다. 또한 교합하중이 임플란트의 장축을 벗어나거나 중심에서 벗어난 경우 응력이 커지는 것으로 사료된다.
연구 목적: 본 연구는 hexagon 높이에 따른 임플란트 각 부위와 주위 지지조직의 응력분포를 3차원 유한요소 해석을 통해 평가하여 hexagon 높이가 기계적 안정성에 미치는 영향을 평가하고자 시행되었다. 연구 재료 및 방법: 외측 연결 형태의 ${\phi}4.0mm{\times}11.5mm$ USII (Osstem Co., Pusan, Korea) 임플란트 시스템을 이용하여 하악 제 1대구치 부위에 임플란트를 식립하여 보철 수복한 경우를 연구 모델로 가정하고 임플란트 고정체의 외측 연결부인 hexagon의 높이를 각각 0.0 mm, 0.7 mm, 1.2 mm, 1.5 mm로 적용한 CAD data를 유한요소 모형화하였다. ABAQUS 6.4 (ABAQUS Inc., Providence, RI, USA)를 이용하여 산출된 응력 값 중에서 등가응력을 기준으로 각 요소(상부 치관, 지대주 나사, 고정체, 치밀골, 해면골)에서 나타나는 최대 응력 값을 비교 하였다. 결과: 외측 연결을 갖는 임플란트의 hexagon의 높이는 고정체, 지대주 나사, 상부 보철물 그리고 주위 지지골에 대해 응력 분산에 영향을 주었다. Hexagon의 높이가 증가할수록 임플란트의 응력 분산은 더 잘 이루어졌으며, 최대 응력 값의 감소를 보였다. Hexagon의 높이가 1.2 mm 이상이 되면 응력 분포에 더 이상 크게 기여하지 않았다. 결론: 외측연결을 갖는 임플란트에서 hexagon은 응력 분산에 필수적인 요소이며 그 높이가 증가할수록 더욱 효과적인 응력의 분산이 나타났다.
보철이나 수복 영역에서 재료 자체의 기계적 특성을 강화하기 위해 많이 사용되어 오던 fiber reinforced composite (FRC)는 최근 교정 영역까지 그 사용이 확대되고 있다 이 연구의 목적은 silica glass fiber로 강화된 FRC (FibreKor. Jeneric/pentron Inc., Wallingford, U. S.A.)를 다양한 기간 동안 물에 저장하였을 때 물 흡수가 FRC의 굽힘 특성에 미치는 영향을 알아보고자 함이었다. 시편은 임상에서 적응하는 원형, (직사)각형의 두 가지 형태를 기준으로 plasma arc light를 이용하여 광중합하여 제작하였다. 각형 원형 각각 5개의 시편을 실은(평균 $23^{\circ}C$)의 증류수 안에 0시간. 1시간. 1일. 1주, 15일 1개월, 3개월의 기간 동안 보관한 후 torque tester를 이용하여 굽힘 시험을 시행하였다 굽힘 강성(flexural stiffness)은 24시간 후에 원형의 경우 58%, 각형의 경우 25%로 감소했으며 3개월 후에는 각각 28%, 19%의 실험 전 상태의 강성을 나타냈다. 항복 굽힘 모멘트(yield flexural moment. $3^{\circ}$ offset)는 24시간 후에 원형의 경우 45% 각형의 경우 75%로 감소했으며 3개월 후에는 실험 전 항복 굽힘 모멘트의 29%, 60%로 각각 감소하였다 파절 굽힘 모멘트(ultimate flexural moment)는 24시간 후에 원형의 경우 30% 각형의 경우 75%로 감소했으며 3개월 후에는 실험 전 값의 25%, 37%로 각각 감소하였다 이상의 실험을 통하여 FibreKor는 물에 보관 시 초기에 굽힘 강성이 급격히 저하됨을 알 수 있었다. 따라서 수분에 대한 굽힘 강도 증가를 위한 연구가 향후 필요할 것이다.
최적의 골유착을 얻기 위하여 임플란트 디자인의 개선과 다양한 표면처리 방법이 개발되어 왔는데, 특히 최근 알칼리 에칭과 이온 주입법, 양극산화법 등 생화학적인 골유착을 유도할 수 있는 표면개질 방법이 관심의 대상이 되고 있다. 이러한 방법 중 마그네슘 이온을 함유한 전해액속에서 양극산화피막처리한 임플란트(마그네슘 임플란트)를 이용하여 조기 하중의 가능성이 제시된 바 있다. 그러나 마그네슘 임플란트의 경우 장기간의 기능적 하중을 가한 경우에 대한 연구가 부족한 상태이므로, 이에 본 연구에서는 비글견을 이용한 동물실험을 통해 지연하중을 가한 마그네슘 임플란트의 방사선적, 임상 안정성 검사 및 조직형태학적 분석을 시행하여 화학적 표면개질 임플란트의 골조직 반응을 기계가공 임플란트와 비교 평가하고자 하였다. 발치 후 3개월의 치유과정을 가진 비글 성견 6마리의 하악에 좌우 3개씩 실험용으로 제작된 직경 3.75 mm, 길이 10.0 mm의 나사 형태 임플란트 36개를 보편적인 임플란트 시술시 이용하는 식립법을 이용하여 식립하였다. 18개의 대조군은 기계가공만 한 상태였고, 실험군은 마그네슘을 함유한 전해액에서 양극산화 피막처리하였다. 식립 후 3개월 동안의 치유기간 후 이차수술을 실시하였으며, 연결고정하지 않고 단일치 금관수복으로 보철물을 장착하여 하중을 가하였다. 3개월 동안 하중을 가한 후에 희생시켜 비탈회 연마 표본을 제작하여 조직형태 계측학적 분석을 시행하였다. 임플란트 식립시, 이차 수술시, 하중을 가한 1개월, 3개월 후에 변연골 흡수를 평가하기 위해 방사선학적 검사를 실시하였고, 골계면 사이에서의 안정성을 평가하기 위해 공진주파수 수치를 측정하였다. Mann-Whitney U test와 repeated measured ANOVA를 이용하여 95 퍼센트 유의수준으로 통계적 유의성을 확인하였다. 총 36개의 임플란트 중 8개에서 일차 수술 후 골유착의 실패가 나타났으며, 1개는 3개월의 부하 후에 실패 양상이 나타났다. 공진주파수분석결과, 마그네슘 임플란트군은 대조군과는 달리 공진주파수 수치가 증가하다가 다소 감소하는 양상을 보였으며, 하중을 가한 3개월 후에는 두 군의 수치가 비슷하였다. 방사선 사진 분석 결과 두 군 모두 시간에 따른 변연골 흡수량이 증가하였으며, 통계적으로 유의한 차이는 없었다. 조직형태학적인 분석 결과 마그네슘-임플란트가 대조군에 비해 더 높은 수치의 골임플란트 계면접촉율을 보여 주었으나, 나사산내 골면적은 더 낮았다. 그러나 두 군 모두에서 통계적 유의성은 없었다. 이상의 결과에서 지연 하중을 가하는 경우에 있어서 골유착에 대한 마그네슘-임플란트의 효과는 기계가공된 임플란트와 유사하였다. 조기 하중시 더 빠르고 강한 골반응을 보여주던 이전 연구와 종합하여 볼 때, 마그네슘 임플란트는 즉시 또는 조기 하중 가능성을 증진시켜 주며, 지연 하중에서는 생체 적합성이 우수한 타이타늄과 유사한 골유착 정도를 보이는 것으로 사료된다. 그러나 임상적으로 화학적 표면개질 방법의 유용성을 판단하기 위해 다양하고 장기적인 임상 연구가 필요하리라 사료된다.
Statement of problem: Following tooth loss, the edentulous alveolar process of maxilla is affected by irreversible reabsorption process, with progressive sinus pneumatization leads to leaving inadquate bone height for placement of endosseous implants. Grafting the floor of maxillary sinus by sinus lifting surgery and augmentation of autologous bone or alternative bone material is a method of attaining sufficient bone height for maxillary implants placement and has proven to be a highty successful. Purpose: This study was undertaken to clarify the morphometric characteristics of inferior maxillary sinus and alveolar process for installation of implants. Material and method: Nineteen skulls (37 sinuses, 10M / 9F) obtained from the collection of the department of anatomy and cell biology of Hanyang medical school were studied. The mean age of the deceased was 69.9 years (range 44 to 88 years). The distance between alveolar border and inferior sinus margin at each tooth, the height of alveolar process and the thickness of cortical bone of the outer and inner table of alveolar process and the inferior wall of maxillary sinus were measured. Results and Conclusion: 1. The septum of inferior maxillary sinus were observe 28 sides (76.%) and located at the third molar (52.6%) and the second molar (26.3%). The deepest points of inferior border of maxillary sinus were located the first or second molar. The distance between alveolar margin and the deepest point of inferior maxillary sinus is $9.7{\pm}4.9mm$. 2. The length of the outer table of alveolar process were $4.9\sim28.2mm$ and the shortest point was between the first and the second molors. The thickness of them were $0.9\sim3.2mm$. The length of the inner table of alveolar process were $7.4\sim25.8mm$ and the shortest point was between the first and the second molars. The thickness of the were $0.9\sim4.6mm$. The results of this study are useful anatomical data for installing of maxillary implants.
임플란트의 골유착 성공 여부를 확인하기 위해서 방사선학적 분석방법을 사용하였다. 치근단 방사선 사진을 이용한 프렉탈 분석방법을 사용하여 기능하중 전 후의 임플란트 주변 골밀도를 분석하고 골유착에 실패한 임플란트와 성공한 임플란트 사이에 유의한 차이가 있는지 비교하였다. 본 연구에서는 원광대학교 치과병원에서 임플란트 식립 시술을 받은 30명의 환자에서 총 42개의 임플란트를 분석에 사용하였다. 환자는 14명의 남자와 16명의 여자로 구성 되었고 나이는 22세에서 73세 사이였다. 치조골의 trabecular 양상의 형태와 프렉탈 분석은 치근단 방사선 사진을 이용하였다. 총 2장의 치근단, 즉 임플란트 식립 직후와 임플란트 보철물 장착 후 기능 하중이 가해진 뒤 3개월 후의 방사선 사진이 사용되었다. 분석은 Image J(1.40s, National Institute of Health, Bethesda, USA)를 이용하여 시행하였다, 통계학적 분석방법은 one-way ANOVA(P<.05)를 이용하여 시행하였다. 그리고 Tukey multiple comparison test로 사후검정을 실시하였다. 프렉탈 분석 결과와 임플란트 주변의 골밀도 변화는 통계적으로 유의할만한 상관관계가 있으며 특히 하악에서 이런 결과가 더욱 명백하였다. 또한 두개의 실패한 임플란트의 경우 프렉탈 수치가 각각 1.2865에서 1.1521로, 1.1135에서 1.0478로 감소되는 경향을 나타냈다.
선천적 기형이나 후천적인 외상 또는 신생물에 의해 상악골 절제술을 받은 경우, 상악에서 발생하는 구강내 결손은 흔히 비강과 상악동 및 구강이 연결된 형태로 나타난다. 이러한 상악골의 결손은 구강과 비강이 교통되어 발음, 저작, 연하 등의 기능에 이상을 초래하게 된다. 이러한 경우에도 보철치료의 기본적인 목표가 적용되며, 후천적 상악 결손부에 수복되는 폐색장치는 발음, 연하, 저작 기능을 회복할 수 있어야 하고, 적절한 심미적 만족을 제공해야 하며, 환자가 편안하게 사용할 수 있어야 한다. 상악 폐색장치의 무게를 감소시키는 것은 잔존 조직의 건강과 정상적인 기능 및 환자의 안락함을 개선시킬 수 있다. 개방형 폐색장치는 결손부의 크기에 따라 6.55~33.06% 까지 무게를 줄여줌으로써 환자에게 편안함과 편의성을 제공해 주며, 생리적 기능을 향상시켜 치아와 지지 조직에 불필요하게 가해지는 부하를 감소시켜 준다. 본 증례는 hemi-maxillectomy를 시행한 환자에서 이중온성법을 이용하여 기존의 방법보다 더 균일한 의치상 두께를 가진 폐색장치를 제작하여 환자의 기능적, 심미적인 만족을 얻었기에 이를 보고하는 바이다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.