• Title/Summary/Keyword: 보조 전원 장치

Search Result 139, Processing Time 0.03 seconds

Development of Static Inverter for the Tilting Train express TTX (틸팅 차량용 보조전원장치의 개발)

  • Lee, Chang-Hee;Kim, Hyung-Cheol;Song, Young-Shin;Lee, Eun-Kyu;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1537-1539
    • /
    • 2005
  • This paper proposes 210[kVA] rated SIV(Static Inverter) system for the TTX(Tilting Train eXpress). The SIV provides power of a fluorescent light in the car, Air-conditioner, and other equipments. To control output voltage it is used voltage control loop for constant voltage control and simultaneously used current control loop for instantaneous control at load changing. The performance of SIV system will be verified by simulation and experimental results.

  • PDF

Power Control of a Hoist System Using Supercapacitor (수퍼캐패시터를 이용한 권상부하 시스템의 전력 제어)

  • Kim, Sang-Min;Sul, Seung-Ki;Yoo, Hyun-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1486-1488
    • /
    • 2005
  • 본 논문에서는 수퍼캐패시터(Supercapacitor 이하 수퍼�L)를 이용하여 엔진 발전기를 전원으로 하는 권상부하 시스템의 부하전력 분배와 회생에너지의 저장 기법을 제안한다. 대표적인 권상부하 시스템인 크레인의 경우, 크게 두가지 운전모드로 동작한다. 첫번째 운전모드는 부하를 들어올리는 동작(Hoist-Up)으로서 가속 종료시점에서 최대전력을 소모한다. 두번째 운전모드는 부하를 내리는 동작(Hoist-Down)으로서 이때 희생되는 전력은 일반적으로 저항을 통하여 소모된다. 본 논문에서는 에너지 저장장치의 하나인 수퍼�L을 이용하여 Hoist-Down 운전에서 희생되는 에너지를 저장하고 Hoist-Up 운전에서 필요한 전력을 보조하도록 하였다. 수퍼�L의 충방전을 위하여 상용 3상 인버터와 동일한 구조를 가지는 DC-DC 컨버터를 제안하였다. 또한 발전기와 수퍼캐패시터의 Load Sharing을 최적화하기 위한 알고리즘을 제안하였다. 제안한 방법을 이용하면 디젤엔진 발전기의 크기를 대폭 줄일 수 있고 따라서 연비의 개선, 소음 및 공해의 감소를 기대할 수 있다. 제안한 방법의 타당성을 검증하기 위하여 시뮬레이션과 실험을 수행하였다.

  • PDF

High Step-up Interleaved ZVT Converters (고승압 인터리빙 ZVT 컨버터)

  • Park, Yohan;Choi, Sewan
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.20-21
    • /
    • 2010
  • 본 논문에서는 무정전 전원장치, 연료전지 등 고승압 응용에 적합한 새로운 인터리빙 ZVT 컨버터를 제안한다. 제안하는 컨버터는 0.7의 듀티로 약 10배 승압이 가능하며 스위치와 다이오드의 전압 정격이 기존 부스트 컨버터보다 약 1/3로 감소되어 $R_{DS(ON)}$이 작은 소자를 사용할 수 있다. 또한 스위치의 ZVS 턴온과 다이오드의 ZCS 턴오프 동작이 가능하고 보조 공진 회로에 의한 공진 모드로 기존 방식에 비해 스위치의 턴오프 손실이 감소한다. 1.5kW의 시작품을 제작하여 제안하는 컨버터의 타당성을 검증하였다.

  • PDF

Control Method for Cut-out of Shorted Load in the Auxiliary Power Supply (보조전원장치의 단락부하 차단기 개방을 위한 제어방법)

  • 황광철;조국춘;최종묵
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.249-254
    • /
    • 1998
  • This paper describes the control methods to cut out the NFB(No Fuse Breaker) of shorted load in the auxiliary power supply, Generally, when the short-circuit occurs in the load of the auxiliary power supply, the auxiliary power supply stops the operation according to the protection sequence. Finally, the other auxiliary power supply stops the operation by the same fault, To resolve this problem, we suggest the control method to trip the NFB of shorted load. That is, when the short circuit occurs, the controller changes control mode from voltage mode to current mode without the operation of output contactor(SIVK) in the auxiliary power supply. The auxiliary power supply provides a large current for the short-circuit load. After some time, the NFB of the short-circuit load is cut off and the auxiliary power supply Provides stable voltage for the loads except for the short-circuit load.

  • PDF

The Study of Auxiliary Power Unit for locomotive (철도차량용 보조전원장치에 관한 연구)

  • Jeong, Han-Dong;Lee, Won-Cheol;Lee, Sang-Seok;Kim, Tae-Hwan;Won, Chung-Yuen
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.615-619
    • /
    • 2009
  • There are many increasing demands for efficient high power density of auxiliary power unit(APU) for high speed traction application. Many techniques have been proposed to measure the voltage flicker on the traditional pulse width modulation(PWM) inverter. This paper proposes a novel functionality of the static inverter on the APU to mitigate the voltage flicker and regulate the output voltage. A new control algorithm for the inverter based on the Hilbert transform(HT) is presented. The HT is employed as an effective technique for tracking the voltage flicker levels in APU systems. Simulation results are provided to verify the tracking capabilities of the HT and to evaluate the performance of the proposed DG interface for multi-function operation.

  • PDF

Combined test of Power Supply System for Korean High Speed Train (고속전철용 보조전원장치 시스템 조합시험)

  • Cho, Hyun-Wook;Kim, Yuen-Chung;Kim, Tae-Hwan;Jang, Kyung-Hyun;Kim, Chul-Ho
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.619-625
    • /
    • 2008
  • Electrical Power supply System conditions of korea high speed train consists of main transformer, four AC-DC PWM converter of Auxiliary Block, Battery Charger in Power Car and Trailer Car, Trailer Inverter, Auxiliary inverter. Main transformer, at nominal voltage of 25kv supplied to secondary winding nominal output Voltage 383Vac, The Auxiliary block consists of AC-DC converters for generating 670VDC power, Auxiliary inverters for ventilation and air compressor, Trailer car inverter provide three phase power supplies at 440Vac for air conditioning and heating. The Battery charger Trailer and Power car supplies 72VDC all necessary equipment to energize the trainset equipment and suppy essential control. This Paper introduces the combined test results of the power supply system for korea high speed train. The main purpose of this combined test is to verify the performance of the power supply system that is designed to operate up to full load test.

  • PDF

A Modified Droop Control Method for Parallel Operation in Railway Auxiliary Power Supply Based on Virtual Impedance (철도 차량용 보조전원장치의 병렬 운전을 위한 가상 임피던스 기반의 드룹 제어)

  • An, Chang-Gyun;Choi, Bong-Yeon;Kang, Jin-Wook;Kang, Kyung-Min;Lee, Hoon;Won, Chung-Yeun
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.342-343
    • /
    • 2019
  • This paper explores the power distribution problem of parallel-connected inverter system which supplies auxiliary power for railway facilities. We propose a droop control method which facilities power distribution and restrain of voltage drop by tracking the average power control command by adjusting the virtual impedance. The performance of proposed droop method is verified by the PSIM simulation.

  • PDF

Research on High-Efficient Power Converters Using WBG Devices for Auxiliary Power Supplies (APS) System (WBG 소자를 적용한 보조전원장치의 고효율, 경량화 연구)

  • Cho, In-Ho;Lee, Jae-Bum
    • Journal of Advanced Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.203-208
    • /
    • 2017
  • Due to global climate change issues, there is a growing demand for systems throughout the industry. In the case of power conversion, studies have been actively conducted to change the structure of the power conversion circuit and to apply new power devices. In particular, the WBG (Wide Band Gap), which is newly emerged device in the market for developing semiconductor technology, has demonstrated advantages in applying for various aspects in comparison to the existing Si (Silicon) Semiconductor. Recent research centers in the railway industry are focusing on developing technologies suitable for railway vehicles by utilizing these new developments in railway countries such as Japan and Europe. This paper researches the WBG device that is applicable to the auxiliary power supplies (APS) in railway system, and analyzes the downsizing effects to APS in high-speed railway by conducting a theoretical analysis and simulation.

New multiple access technology for Bluetooth to collect the movement pattern of children (어린이 동선 환경정보 수집하기 위한 블루투스 동시접속 기술 설계)

  • Hwang, Seong-kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1262-1268
    • /
    • 2016
  • Bluetooth has been developed to be applied over the course of several versions in different environments. Especially low is moving to address the constraints, it gives a high utilization rate is faster than the Zigbee wireless LAN communication. To gather information on children's environmental copper transition to multiple versions. There is one limitation of Bluetooth requirements to effectively apply the information collected by Bluetooth. At the same time need to collect several information actions, Bluetooth can not connect to one of only seven Slave Master. In this paper, in order to take advantage of the many benefits of Bluetooth to gather the information by operating the Bluetooth operates in Beacon deliver packets of 168 bits, and the pairing between the master and slave unnecessarily generate a regular signal a large number of connections simultaneously Information We consider how to apply the effective policy that can be collected.

Analysis and measurement of low frequency magnetic field according to internal position of electric railway train (전기철도차량 객실 내부 위치에 따른 극저주파 자계 측정 및 분석)

  • Jang, Dong-Uk;Han, Moon-Seob
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.489-494
    • /
    • 2008
  • The measurement of magnetic field is performed about DC and AC magnetic field in electric railway line. The test point is cap, on the converter/inverter box, on the traction motor and on the SIV, the height of measurement is bottom and 60 cm height. In case of AC magnetic field, the selected specific frequency is measured on the converter/inverter box. The AC magnetic field is checked and analysis through BNC output, DAQ cad and notebook PC.

  • PDF