• Title/Summary/Keyword: 보정기

Search Result 1,464, Processing Time 0.028 seconds

On-Orbit AOCS Sensor Calibration of Spacecraft (인공위성의 궤도상에서 자세제어계 센서 보정)

  • Yong, Gi-Ryeok;Lee, Seon-Ho;O, Si-Hwan;Bang, Hyo-Chung;Lee, Seung-U
    • Aerospace Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.90-101
    • /
    • 2006
  • In this paper, the calibration parameters of the gyros and star hackers are estimated by using an on-orbit AOCS sensor calibration algorithm. The calibration algorithm was implemented by Kalman filter. In order to estimate gyro calibration parameters, the calibration algorithm requires calibration maneuver and it was analyzed whether the star trackers are protected by Sun, Moon and Earth or not. Also the star tracker calibration algorithm used the camera image information. This kinds of camera image information simulated ground control point and orbit information. The estimated accuracy of star tracker calibration parameters depends on camera image information.

  • PDF

별 추적기의 성능향상을 위한 광행차 보정에 대한 연구

  • 용기력;김응현;이선호;오시환;최홍택;이승우
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.68-68
    • /
    • 2003
  • 본 논문은 별 추적기의 여러 가지의 성능변수 중에 광행차가 성능에 미치는 영향을 연구하였다. 일반적으로 광행차는 별 추적기의 저주파오차로 작용하며, 별 추적기 좌표계에서 최대 27" 정도의 성능을 감소시킨다. 지구가 태양 주위를 공전함으로써 야기되는 광행차는 약 21"이며, 줄리안 데이트를 통해서 보정이 가능하며, 관성 좌표계에서 지구 저궤도 위성이 궤도운동을 함으로 야기되는 광행차 오차는 약 6" 이며, 궤도정보를 통해서 보정이 가능하다. 이를 보정하기 위해서, 보정 알고리즘을 구현하여 다목적 실용위성 자세제어계 성능해석 소프트웨어를 통해서 검증을 하였다.

  • PDF

Design of a Free-form Mueller Matrix Ellipsometer with Imperfect Compensators (불완전한 보정기를 적용한 자유형 뮬러행렬타원계의 설계)

  • Kim, Sang Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.2
    • /
    • pp.59-66
    • /
    • 2022
  • A free-form Mueller matrix ellipsometer (MME) based on independent control of the azimuthal angle of each polarizing element is introduced. The azimuthal angles of the polarizer and the matching compensator which generate the optimum Stokes vectors of an incident beam are investigated for the polarization state generator, where the spectral responses of the retardation angle and transmittance ratio of a nonideal compensator are taken into account. Similarly, the azimuthal angles of the analyzer and the corresponding compensator are investigated for the polarization-state detector, to unambiguously determine the Stokes vector of the outcoming beam from the sample, and explicit expressions for the Stokes elements are derived. Since the suggested technique enables one to utilize a nonideal quarter-wave plate as the compensator for an MME, it will contribute to the construction and application of a Mueller matrix spectroscopic ellipsometer (MMSE) operating over a wide spectral range from deep ultra-violet to near infrared.

Design of Active Power Factor Corrector for Low Power Supply by Loss Free Resistor Concept (무손실 저항개념을 이용한 저전력 전원설비용 능동 역률보정기의 설계)

  • 임영철;정영국;최찬학;나석환;이건식;장영학
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.1
    • /
    • pp.30-36
    • /
    • 1993
  • A simple discontinuous conduction mode(DCM) flyback type active power factor corrector for low power supply resents an effective resistive load to its power input. It is therefore well suited as an inexpensive high power factor rectifier for office equipment. An equivalent circuit model for the Active Power Factor Corrector based on the "Loss Free Resistor" concept is presented. This simple model correctly describes the basic power processing properties of the Active Power Factor Corrector, including input port resistor emulation, output port power some characteristics.teristics.

  • PDF

Development and Performance Evaluation of an Ultra-Compact CT with Auto Calibration of Detector Center Axis (검출기 중심축을 자동 보정하는 초소형 CT 개발 및 성능평가)

  • Byeong-Woo Kwak;Keun-Ho Rew
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.651-662
    • /
    • 2023
  • In this study, we designed and fabricated an ultra-compact CT that automatically calibrates the detector's center axis and verified its performance. The three-dimensional reconstruction performance was evaluated using 3D CAD data and X-ray data acquired by manually calibrating the center axis of the CT detector. The results showed that tilting the center axis by more than 0.25° causes circle break phenomenon, which rapidly degrades the quality of the 3D reconstructed image. By applying the automatic calibration device of a detector center axis, the 3D reconstruction performance was enhanced by calibrating the detector center axis to match the specimen rotation axis.

Design of ZQ Calibration Circuit using Time domain Comparator (시간영역 비교기를 이용한 ZQ 보정회로 설계)

  • Lee, Sang-Hun;Lee, Won-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.3
    • /
    • pp.417-422
    • /
    • 2021
  • In this paper, a ZQ calibration using a time domain comparator is proposed. The proposed comparator is designed based on VCO, and an additional clock generator is used to reduce power consumption. By using the proposed comparator, the reference voltage and the PAD voltage were compared with a low 1 LSB voltage, so that the additional offset cancelation process could be omitted. The proposed time domain comparator-based ZQ calibration circuit was designed with a 65nm CMOS process with 1.05V and 0.5V supply voltages. The proposed clock generator reduces power consumption by 37% compared to a single time domain comparator, and the proposed ZQ calibration increases the mask margin by up to 67.4%.

An Experimental Study on Density Tool Calibration (밀도검층 검출기 보정에 관한 기초 연구)

  • Kim, Yeonghwa;Kim, Kiju;Lim, Heontae;Kim, Jihoon;Kong, Nam-Young
    • Journal of the Korean Geophysical Society
    • /
    • v.7 no.4
    • /
    • pp.237-245
    • /
    • 2004
  • Series of basic experiments for current density calibration by user process and for density calibration using geophysical model borehole were made. We tried to find the sonde response characteristics for current calibration using water and aluminium field jig, and using the equation of half life of 137Cs source. The result of calibration test made in a geophysical model borehole built first in Korea shows a perfect linear calibration equation. By adopting this calibration equation we could estimate the limitation as well as possibility of current density calibration by user process.

  • PDF

Construction of calibration models and calibrating experiment for efficient Held application of density log (밀도검층의 효과적인 현장 적용을 위한 모형 보정공 건설과 밀도 보정 기초연구)

  • Kim Ji-hoon;Kong Nam-young;Zhao Weijun;Kim Yeong-hwa
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.09a
    • /
    • pp.73-82
    • /
    • 2005
  • We constructed a series of calibration models in the campus of Kangwon National University. A series of experiment for calibrating sonde response as well as casing effect in field measurement. Here we explained the process of construction of calibrating facility which consists of three model holes of different density and three model holes of different diameter. It was discussed the calibration equations obtained from its sonde response calibration test. A density correction chart for different separation of detector from hole wall was suggested, and verified the possibility of determining true density from measurements in cased hole.

  • PDF

Dependence Evaluation of the Self-Absorption Correction Factor for p-type High Purity Germanium Detector Characteristics (p-type HPGe 검출기 특성에 따른 밀도 보정인자 의존도 평가)

  • Jang, Mee;Ji, Young-Yong;Kim, Chang-Jong;Lee, Wanno;Kang, Mun Ja
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.4
    • /
    • pp.295-300
    • /
    • 2015
  • The precise determination of the activity for each radionuclide in environmental samples requires the self-absorption correction factor. In this research, we derived the self-absorption correction factor for three p-type high purity germanium detectors using the Monte Carlo code MCNPX. These detectors have different characteristics such as crystal diameter, height and size of the core. We compared the calculated full-energy peak efficiency with the experimental value using a standard sample with $1g/m^3$ density and verified the modeling. We simulated the dependency of the full-energy peak efficiency on the 0.3, 0.6, 0.9, 1.0, 1.2 and $1.5g/m^3$ samples and obtained the corresponding self-absorption correction factor. The self-absorption correction factors calculated for the three detectors differ by less than 1% over most of the energy range and sample densities considered. This indicates that the self-absorption correction factors are independent of the crystal characteristics of HPGe detector.

Integrated Automatic Pre-Processing for Change Detection Based on SURF Algorithm and Mask Filter (변화탐지를 위한 SURF 알고리즘과 마스크필터 기반 통합 자동 전처리)

  • Kim, Taeheon;Lee, Won Hee;Yeom, Junho;Han, Youkyung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.3
    • /
    • pp.209-219
    • /
    • 2019
  • Satellite imagery occurs geometric and radiometric errors due to external environmental factors at the acquired time, which in turn causes false-alarm in change detection. These errors should be eliminated by geometric and radiometric corrections. In this study, we propose a methodology that automatically and simultaneously performs geometric and radiometric corrections by using the SURF (Speeded-Up Robust Feature) algorithm and the mask filter. The MPs (Matching Points), which show invariant properties between multi-temporal imagery, extracted through the SURF algorithm are used for automatic geometric correction. Using the properties of the extracted MPs, PIFs (Pseudo Invariant Features) used for relative radiometric correction are selected. Subsequently, secondary PIFs are extracted by generated mask filters around the selected PIFs. After performing automatic using the extracted MPs, we could confirm that geometric and radiometric errors are eliminated as the result of performing the relative radiometric correction using PIFs in geo-rectified images.