• Title/Summary/Keyword: 보정/검증

Search Result 1,265, Processing Time 0.032 seconds

Method of BeiDou Pseudorange Correction for Multi-GNSS Augmentation System (멀티 GNSS 보정시스템을 위한 BeiDou 의사거리 보정기법)

  • Seo, Ki-Yeol;Kim, Young-Ki;Jang, Won-Seok;Park, Sang-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.10
    • /
    • pp.2307-2314
    • /
    • 2015
  • This paper focuses on the generation algorithm of BeiDou pseudorange correction (PRC) and simulation based performance verification for design of Differential Global Navigation Satellite System (DGNSS) reference station and integrity monitor (RSIM) in order to prepare for recapitalization of DGNSS. First of all, it discusses the International standard on DGNSS RSIM, based on the interface control document (ICD) for BeiDou, estimates the satellite position using satellite clock offset and user receiver clock offset, and the system time offset between Global Positioning System (GPS) and BeiDou. Using the performance verification platform interfaced with GNSS (GPS/BeiDou) simulator, it calculates the BeiDou pseudorange corrections , compares the results of position accuracy with GPS/DGPS. As the test results, this paper verified to meet the performance of position accuracy for DGNSS RSIM operation required on Radio Technical Commission for Maritime Services (RTCM) standard.

Verification of GEO-KOMPSAT-2A AMI Radiometric Calibration Parameters Using an Evaluation Tool (분석툴을 이용한 천리안2A 기상탑재체 복사 보정 파라미터 검증)

  • Jin, Kyoungwook;Park, Jin-Hyung
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_1
    • /
    • pp.1323-1337
    • /
    • 2020
  • GEO-KOMPSAT-2A AMI (Advanced Meteorological Imager) radiometric calibration evaluation is an essential element not only for functional and performance verification of the payload but for the quality of the sensor data. AMI instrument consists of six reflective channels and ten thermal infrared ones. One of the key parameters representing radiometric properties of the sensor is a SNR (Signal-to-Noise Ratio) for the reflective channels and a NEdT (Noise Equivalent delta Temperature) for the IR ones respectively. Other important radiometric calibration parameters are a dynamic range and a gain value related with the responsivity of detectors. To verify major radiometric calibration performance of AMI, an offline radiometric evaluation tool was developed separately with a real-time AMI data processing system. Using the evaluation tool, validation activities were carried out during the GEO-KOMPSAT-2A In-Orbit Test period. The results from the evaluation tool were cross checked with those of the HARRIS, which is the AMI payload vendor. AMI radiometric evaluation activities were conducted through three phases for both sides (Side 1 and Side 2) of AMI payload. Results showed that performances of the key radiometric properties were outstanding with respect to the radiometric requirements of the payload. The effectiveness of the evaluation tool was verified as well.

Integration of IKONOS-2 Satellite Imagery and ALS dataset by Compensating Biases of RPC Models (RPC 모델의 보정을 통한 IKONOS-2 위성영상과 항공레이저측량 자료의 정합에 관한 연구)

  • Lee, Jaebin;Yu, Kiyun;Lee, Changno;Song, Wooseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3D
    • /
    • pp.437-444
    • /
    • 2008
  • In the paper, a methodology is verified to integrate IKONOS-2 satellite imagery and ALS dataset by compensating biases of RPC models. To achieve this, conjugate features from both data should be extracted in advance. For this purpose, linear features are chosen as conjugate features because they can be accurately extracted from man-made structures in urban area and more easily extracted than point features from ALS data. Then, observation equations are established from similarity measurements of the extracted features. During the process, several kinds of transformation functions were selected and used to register them. In addition, it was also analyzed how the number of linear features used as control features affects the accuracy of registration results. Finally, the results were evaluated by using check-points obtained from DGPS surveying techniques and it was clearly demonstrated that the proposed algorithms are appropriate to integrate these data.

Development of Distortion Correction Technique in Tilted Image for River Surface Velocity Measurement (하천 표면영상유속 측정을 위한 경사영상 왜곡 보정 기술 개발)

  • Kim, Hee Joung;Lee, Jun Hyeong;Yoon, Byung Man;Kim, Seo Jun
    • Ecology and Resilient Infrastructure
    • /
    • v.8 no.2
    • /
    • pp.88-96
    • /
    • 2021
  • In surface image velocimetry, a wide area of a river is photographed at an angle to measure its velocity, inevitably causing image distortion. Although a distorted image can be corrected into an orthogonal image by using 2D projective coordinate transformation and considering reference points on the same plane as the water surface, this method is limited by the uncertainty of changes in the water level in the event of a flood. Therefore, in this study, we developed a tilt image correction technique that corrects distortions in oblique images without resetting the reference points while coping with changes in the water level using the geometric relationship between the coordinates of the reference points set at a high position the camera, and the vertical distance between the water surface and the camera. Furthermore, we developed a distortion correction method to verify the corrected image, wherein we conducted a full-scale river experiment to verify the reference point transformation equation and measure the surface velocity. Based on the verification results, the proposed tilt image correction method was found to be over 97% accurate, whereas the experiment result of the surface velocity differed by approximately 4% as compared to the results calculated using the proposed method, thereby indicating high accuracy. Application of the proposed method to an image-based fixed automatic discharge measurement system can improve the accuracy of discharge measurement in the event of a flood when the water level changes rapidly.

Analysis of Geometric Calibration Accuracy using the Results from IR Channel Nominal Radiometric Calibration (적외채널 기본 복사보정 결과를 이용한 기하보정 처리의 정확도 분석)

  • Seo, Seok-Bae;Kwon, Eun-Joo;Jin, Kyoung-Wook
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.147-155
    • /
    • 2013
  • The nominal radiometric calibration equation and additional five algorithms are applied in the infrared channel radiometric calibration for the COMS (Communication, Ocean, Meteorological Satellite) MI (Meteorological Imager). The processing end time of the radiometric calibration is directly related with the start time of geometric calibration processing since the geometric calibration processing is followed by that of the radiometric calibration. This paper describes comparison and analysis results for geometric calibration processing using two types of the radiometric calibration results, outputs from only the nominal radiometric calibration equation and outputs from the complete one (the nominal radiometric calibration equation with additional five algorithms), to propose a method with the earlier start time of the geometric calibration processing. Experimental results show that both of radiometric calibration results, from the nominal radiometric calibration equation with a fast processing speed and from the complete one with accurate radiometric values, can be used in the geometric calibration as the appropriate inputs because those processing results satisfied the requirements of geometric calibration processing accuracy. Thus the radiometric calibration results from the nominal radiometric calibration equation can be used to improve geometric calibration processing time.

A New Calibration Equation for Predicting Water Contents With TDR (TDR의 함수비 예측을 위한 새로운 보정방정식)

  • Song, Minwoo;Kim, Daehyeon;Choi, Chanyong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.1
    • /
    • pp.59-65
    • /
    • 2015
  • The objective of the study is to verify a new calibration equation of dry density and water contents with TDR. Since the traditional calibration equation was proposed, some research to develop a new calibration equation has been conducted by several researchers. As traditional calibration equation is difficult to be applied for loose soil and fine-grained soil at high water contents, this study developed a new calibration equation. Thus, this study introduces a new calibration equation and its applicability by comparing TDR test results with conventional test results. Based on the analyses, the calibration equation for water content has large error. A new calibration equation was proposed and it showed more than 95% accuracy for estimating water content of soil.

Evaluation of Correction Parameter for the Free-fall Grab Based Mn Nodule Abundance in the Southern Sector of the KODOS (KODOS 남쪽광구에서 자유낙하식 채취기로 채취된 망간단괴 부존률 평가를 위한 보정상수 검증)

  • Lee, Hyun-Bok;Ko, Young-Tak;Kim, Jong-Uk;Chi, Sang-Bum;Kim, Won-Nyon
    • Economic and Environmental Geology
    • /
    • v.44 no.6
    • /
    • pp.475-483
    • /
    • 2011
  • Quantitative estimate of manganese nodules based on the operation of a free fall grab (FFG) needs to be corrected because of its less retrieval ability. Previously, the correction parameter of the nodule abundance collected by FFG was calculated based on the image analysis of the photos of bottom sediment in the northern sector of the nodule exploration area of Korea in the NE equatorial Pacific. However, nodules in the southern sector are commonly covered by sediment, which may prevent the use of the correction parameter estimated by photographic techniques. In this study, we attempted dual nodule sampling at the same location by different equipments (i.e. box corer (BC) and FFG) to examine the previous correction parameter of nodule abundance for FFG operation. During the exploration cruises in 2007 to 2009, Mn-nodules were collected from 40 stations both by BC and FFG in the southern sector. The correlation analysis between BC and FFG operations revealed that the BC collected nodules 1.43 times larger than FFG. Our result suggests that the correction parameter of 1.43 can be applied for collection of FFG data to estimate Mn-nodule distribution in the southern sector. The obtained parameter is similar to the previous parameter (1.42~1.45) calculated by the image analysis method, indicating an usefulness of new correction parameter suggested by this study.

The Correlation of Thermal Analysis Model using Results of LEO Satellite Optical Payload's Thermal Vacuum Test (저궤도위성 광학탑재체의 열진공시험 결과를 이용한 열해석 모델 보정)

  • Kim, Min-Jae;Huh, Hwan-Il;Kim, Sang-Ho;Chang, Su-Young;Lee, Deog-Gyu;Lee, Seung-Hoon;Choi, Hae-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.620-621
    • /
    • 2010
  • Thermal models are made to verify the process that operate in space orbit. In this study, thermal analysis model correlation was performed to satisfy the criteria of correlation. Ground thermal vacuum test results are used for the correlation thermal model in the process of thermal model verification.

  • PDF

Correction for Scanning Errors of a CCD Camera Scanner (CCD Camera Scanner의 스캐닝 왜곡 보정기법 연구)

  • 안기원
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.12 no.2
    • /
    • pp.173-180
    • /
    • 1994
  • One can see more and more photograrmmetric applications dealing with the extraction of information from images obtained with CCD (Charge Coupled Device) camera scanners. In order for this information to be useful, the scanning errors of scanners must be known through a calibration. Investigation of this study is given to the detailed procedure of the correction for scanning errors created during the scanning of photographs with CCD camera scanner using the three kinds of high resolution reseal plates prepared. The geometric corrected digital images for scanning errors were generated and the accuracy of the resulting new images for each types of plates were checked comparing its image coordinates with there corresponding ground coordinates for the check points.

  • PDF

RFM으로 생성된 레이더 정사영상 자료의 정확도 분석

  • 이선일;김윤형;이규성
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2003.04a
    • /
    • pp.121-128
    • /
    • 2003
  • 사면관측 원리에 의해 획득되는 레이더 영상은 레이더파의 입사각도와 지표면의 경사도 및 방위각에 따라 기하학적 왜곡이 발생하게 된다. 전 국토의 70% 이상이 산악지형인 국내 여건을 감안한다면 레이더 영상의 정량적 활용을 위해서는 정밀한 기하보정이 반드시 필요하다. 본 연구에서는 RADSARSAT-1 SAR 영상에 대하여 세 가지 기하보정 방법을 적용하였다. 먼저 GCP 만을 이용한 단순기하보정을 수행하였고, 두번째로 위성의 자세와 위치정보 등을 이용하여 센서모델을 통한 보정을 하였다. 마지막으로 다양한 영상자료에 적용할 수 있는 RFM(Rational Function Model)을 이용하여 기하보정을 하였다. 이 세 가지 방법으로 기하보정된 레이더 영상의 위치정확도를 모의 레이더 영상과 비교 분석하였다. 또한 RFM을 이용한 보정결과를 검증하기 위하여 SIR-C 영상을 추가로 분석하였다.

  • PDF