• Title/Summary/Keyword: 보이드

Search Result 178, Processing Time 0.036 seconds

Comparison and analysis of electrical treeing and PD distribution according to defects models (결함에 따른 전기트리의 발생양상 및 PD 분포 특성의 비교/분석)

  • Jeong, Hae-Eun;Park, Song-Hee;Lim, Kee-Joe;Kang, Soeng-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.497-498
    • /
    • 2006
  • 본 논문에서는 전력기기의 고체 절연물내에서 발생하는 전기트리의 진전양상 및 그에 대한 PD 분포 특성을 Hn(q), $Hn(\Psi)$, $Hq_{avg}{\Psi})$, $Hq_{max}(\Psi)$로 표현하였다. 또한 통계적 분포의 변화정도를 나타내어 정량적으로 확인을 하고자 하였다. 논문에서 사용한 트리 결함은 침-평판 트리, 보이드트리, 고체절연물내 이물트리 등 세 가지 경우이며, 각각의 트리 진전에 대한 특성은 서로 다른 특성을 보이는 것으로 나타났다.

  • PDF

Flow Characteristics of Vertical Upward Gas-Liquid Two-Phase Flow (수직상향 기액이상류의 유동특성)

  • Choi Bu-Hong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.4
    • /
    • pp.377-383
    • /
    • 2005
  • This paper deals with the flow characteristics of air-water two-phase flow in a vertical tube of 10mm I.D. and 600mm in length at an adiabatic condition. The obtained experimental data were covered with the liquid superficial velocity ranging from 0.095m/s to 2.56m/s. and the gas superficial velocity ranging from 0.032m/s to 21.08m/s. The effects of the gas and liquid superficial velocity on the flow pattern transitions, frictional pressure drop, and film thickness and gas-liquid interface roughness were also examined. It was found that the film thickness increased and the liquid film wave length was more longer with the liquid superficial velocity $j_L$ increasing at $j_G$ constant. It was also showed that the frictional pressure drops were experienced in three regions. namely increasing region(bubbly flow), decreasing region (Taylor bubble and slug flows) and re-increasing region (annular flow).

A Prediction of the Air-lift Pump Performance by gas-liquid Flow Charac teristics of Riser (Riser의 기액유동 특성에 따른 Air-lift 펌프의 성능예측)

  • 박찬수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.252-258
    • /
    • 1999
  • As an effective means to convey crushed materials from seabed to on board ship and to raise hazardous or abrasive liquids air-lift pump provides a reliable mechanism due to its simple config-uration and easy-to-operate principle. The present study is focused on fundamental investigation of related performance by the analysis program based on the gas-liquid two-phase flow in circular pipes. The program covers pump operating in isothermal and vertical two-phase flow with Newto-nian liquids. it is summarized as important result that an optimum air mass flow rate exists for the maximum lifted liquid mass flow rate in terms of a given submergence rates and furthermore attachment of downcomer gives little effects on riser performance the conveyed liquid flow rate increases with larger submergence rate.

  • PDF

Improved Munilla-Peinado's RFID Distance Bounding Protocol (개선한 Munilla-Peinado RFID 경계 결정 프로토콜)

  • Ahn, Hae-Soon;Yoon, Eun-Jun;Bu, Ki-Dong;Nam, In-Gil
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.04a
    • /
    • pp.824-825
    • /
    • 2010
  • 최근 RFID 태그들이 근접 인증(proximity authentication)을 위해 사용자의 위치나 상황을 이용하여 통신하기 때문에 위치 기반 공격인 중계 공격(relay attack)에 매우 취약함이 증명되었다. 이러한 중계 공격들을 방지하기 위해 리더와 태그사이의 메시지 송수신 왕복 시간을 측정하는 경계 결정(distance-bounding) 프로토콜이 한 해결책으로 연구되고 있다. 2008년에 Munilla와 Peinado는 Hancke-Kuhn이 제안한 프로토콜을 수정하여 보이드(void) 기법을 적용한 RFID 경계 결정 프로토콜을 제안하였다. 공격자에게 n번의 왕복에서 $(5/8)^n$으로 성공 확률을 감소시켰지만, 저비용 수동형 태그에서 많은 통신량과 저장 공간을 요구하므로 비효율적이다. 따라서 본 논문에서는 태그측의 해쉬 함수 연산량을 줄이고, 적은 저장 공간을 요구함으로써 저비용 RFID 시스템에 적합한 효율적인 RFID 경계 결정 프로토콜을 제안한다.

Effects of Annular Gap Size on the Flow Pattern and Void Distribution in a Vertical Upward Two-Phase Flow (수직상향 이상류에서 동심원관 간극이 유동양식과 보이드분포에 미치는 영향)

  • Son B. J.;Kim I. S.;Kim M. C.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.4
    • /
    • pp.383-391
    • /
    • 1987
  • An experimental investigation has been conducted to determine the flow pattern for two-component , two-phase mixtures which flow vertically upwards in concentric annuli based on the measurement for the local void fraction and the distribution of the local void fraction in various radial locations in the annular gap. The annular test section consists of a lucite outer tube whose inside diameter is 38mm and a stainless steel rod, The rod diameter is either :2mm,16mm or 20mm. It is demonstrated that the probability density function of the fluctuations in void fraction may be used as an flow pattern indicator and the local void fraction distribution depends on the flow pattern and radial location in the annular passage.

  • PDF

Fluctuation Characteristics of Radial Void Fraction in Vertical Concentric Annuli (수직동심환상관에서 반경방향 보이드율의 변동특성)

  • Son B.J.;Kim I.S.;Kim M.C.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.5
    • /
    • pp.516-524
    • /
    • 1987
  • This paper presents experimental data of fluctuation characteristics of local void fraction of air-water two-phase flow which are associated with the flow pattern, annular gap size and radial location in vertical concentric annuli with coefficient of skewness and kurtosis. The annular gap widths are 13mm, 11mm, and 9mm for a 38m inner diameter as the lucite outer tube. A electrical conductivity probe was used to measure the local void fraction and traversed diametrically from inner wall to outer wall using radial increments of 2mm. It was shown that distribution of the coefficient of skewness and kurtosis, which is related that the one is the asymmetry and the other peakness of local void fraction distribution was influenced by flow pattern, annular gap size and radial location.

  • PDF

A Semantic Text Model with Wikipedia-based Concept Space (위키피디어 기반 개념 공간을 가지는 시멘틱 텍스트 모델)

  • Kim, Han-Joon;Chang, Jae-Young
    • The Journal of Society for e-Business Studies
    • /
    • v.19 no.3
    • /
    • pp.107-123
    • /
    • 2014
  • Current text mining techniques suffer from the problem that the conventional text representation models cannot express the semantic or conceptual information for the textual documents written with natural languages. The conventional text models represent the textual documents as bag of words, which include vector space model, Boolean model, statistical model, and tensor space model. These models express documents only with the term literals for indexing and the frequency-based weights for their corresponding terms; that is, they ignore semantical information, sequential order information, and structural information of terms. Most of the text mining techniques have been developed assuming that the given documents are represented as 'bag-of-words' based text models. However, currently, confronting the big data era, a new paradigm of text representation model is required which can analyse huge amounts of textual documents more precisely. Our text model regards the 'concept' as an independent space equated with the 'term' and 'document' spaces used in the vector space model, and it expresses the relatedness among the three spaces. To develop the concept space, we use Wikipedia data, each of which defines a single concept. Consequently, a document collection is represented as a 3-order tensor with semantic information, and then the proposed model is called text cuboid model in our paper. Through experiments using the popular 20NewsGroup document corpus, we prove the superiority of the proposed text model in terms of document clustering and concept clustering.

A Robust Continuous Object Tracking Protocol Using Chained Selective Wakeup Strategy in Wireless Sensor Networks (무선 센서 네트워크에서 연결된 선택적 활성화 기법을 사용하는 강건한 연속 객체 추적 프로토콜)

  • Hong, Hyungseop;Kim, Sang-Ha
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.1
    • /
    • pp.72-79
    • /
    • 2013
  • In wireless sensor networks, the selective wakeup scheme is one of the energy saving mechanisms, that is used for an object detecting or tracking. Recently, many protocols are proposed using the selective wakeup scheme for the continuous objects tracking such as forest fires and poison gas. They predict the future shape of continuous objects and activate only sensors in the predicted boundary area of the objects. It works correctly in a uniformly deployed wireless sensor networks. However, it cannot be directly applied to a randomly deployed sensor networks with voids. When the predicted area is in the void area, the activation message cannot reach and the predicted area cannot be activated at the right time. It leads to many detection errors for continuous object. Moreover, if a sensor is once foiled in a activation control then the next activation control might be continuously failed. The detection errors can be result in serious harm to people. In this paper, we propose a chaining selective wakeup scheme for robust continuous object tracking in wireless sensor networks. In our protocol, we collect the information of a void area during the network configuration time; if the next boundary area is in the void area, we activate the chained area surrounding the void area with activation control message.

Study of the Method to Examine the Cause of Damage to a Flat-Type Vinyl Cord (VFF) According to the Type of Energy Source (에너지원의 종류에 따른 비닐평형코드(VFF)의 소손원인 판정기법에 관한 연구)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.83-88
    • /
    • 2011
  • This study presented the structure and characteristics of vinyl cords used for wiring electric equipment and appliances and analyzed the photographs of damaged flat-type vinyl cords (VFF, $1.25mm^2$) and the metallic cross-sectional structure of melted conductors. Normal VFFs were made by twisting several strands together and the surface of the conductor was red brown. In addition, from the analysis of the metallic structure of the conductor, it was found that its grains had been elongated. The surface of a VFF damaged by normal flame showed no sheen with carbonized insulation material fused on the conductor surface. In addition, from the analysis of the cross-sectional structure of the melted area, it was found that voids of a certain shape were formed on it but that the cord's own elongation structure could not be checked. The cross-sectional analysis of the melted conductor damaged by the external flame applied to a VFF to which electric current was being applied showed no elongation structure for each cord, and revealed that irregular voids and a columnar structure had grown. The surface of the VFF damaged by overcurrent was uniformly carbonized and the cross-sectional structure analysis of the melted conductor revealed that the dendritic structure had grown. The analysis of the characteristics of the VFF melted by short-circuit showed that even though some part of the surface was contaminated, it showed little sheen and that the area rebounded by melting was round in shape. In addition, the cross-sectional structure analysis using a metallurgical microscope showed the boundary surface and columnar structure and revealed an amorphous structure like normal copper at areas other than the melted conductor.

The Study on the Drag Reduction for Gas/Liquid Two Phase Flow (기-액(氣-液) 2상유동(二相流動)시 항력(抗力)에 관(關)한 연구(硏究))

  • Cha, K.O.;Oh, Y.K.;Kim, J.G.
    • Journal of ILASS-Korea
    • /
    • v.1 no.3
    • /
    • pp.20-28
    • /
    • 1996
  • It is well known that drag reduction in single phase liquid flow is affected by polymer material, molecular weight, polymer concentration, pipe diameter, and flow velocity. Drag reduction in two phase flow can be applied to the transport of crude oil, phase change system such as chemical reactor, pool and boiling flow, and to present cavitation which occurs in pump impellers. But the research of drag reduction in two phase flow is not sufficient. The purpose of the present work is to evaluate the drag reduction by measuring pressure drop, void fraction whether polymer is added in the horizontal two phase system or not. Experiment has been conducted in a test section with 24 m of the inner diameter and 1,500 mm of the length. The used polymer materials are two kinds of polyacrylamide[PAAM] and co-polymer[A611P]. The polymer concentration was varied with 50, 100 and 200 ppm under the same experimental conditions. Experimental results were shown that the drag is higher reduced by co-polymer rather than polyanylamide.

  • PDF