• Title/Summary/Keyword: 보의 처짐

Search Result 266, Processing Time 0.028 seconds

An Experimental Study on the Fatigue Behaviors Strengthened by Ventilation-Glass Fiber Plate of Reinforced Concrete Beams (철근콘크리트 보의 통기성 유리섬유판 보강에 따른 피로거동에 관한 실험적 연구)

  • Kim, Woonhak;Kang, Seokwon;Shin, Chunsik
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.391-400
    • /
    • 2012
  • Recently, the construction industry commonly uses FRP as a reinforcement material because of its material advantages. FRP attached reinforcement has various advantages such as high strength, stiffness, excellent durability and construction practicability comparing to its weight. However, external attachment of FRP is water-tighted with low water permeable material, not draining water, probably causing damages on a permanent structure. The study manufactured it through pultrusion and examined GP(glass fiber panel) of which material-mechanical properties are almost same as the existing FRP but durability and attachment performance are better by stationary experiments, testing load-deflection curve, destruction types and load-deflection relation under repetitive loading test. As a result of 2,000,000 fatigue tests, it did not result in the destruction and showed excellent permanent attachment and durability as it displays significantly low compressive strain of concrete.

복합재료의 탄성학 소개

  • 황운봉
    • Journal of the KSME
    • /
    • v.29 no.3
    • /
    • pp.231-243
    • /
    • 1989
  • 복합재료의 탄성 문제를 정리하면 다음과 같다. 복합재료와 등방성 재료의 탄성학적 차이는 재료의 탄성계수에 기인하며 이것은 각각 다른 형태의 응력-변형률관계를 갖게 한다. 한편 응 력-변형률 관계식을 제외한 탄성학의 지배방정식은 재료의 종류에 관계없이 성립한다. 복합적 층판의 Stiffness와 응력 등은 Lamination 이론을 사용하여 구할 수 있다. 판이론은 평형식을 z방향으로 적분한 식, 즉 합력(resultant force)와 모멘트로 나타낸 평형식을 사용하는데 이 때 처짐 방정식을 구하기 위해 합력. 모멘트-곡률. 변형률 관계식을 이용하는데 이 관계식이 복합 재료와 등방성재료가 상이하다. 결과로 복합재료는 커플링 효과를 갖게 되며, 복합적층판을 대 칭으로 쌓으면 이 효과를 상쇄시킬 수 있다. 복합적층 보의 이론은 유효 굽힘 계수를 도입하면 등방체 보 이론을 사용하여 보의 처짐을 해석할 수 있다. 복합적층 보의 경우 굽힘 응력의 최 대치는 등방체와는 달리 보의 표면에서만 일어나지 않고 내부에서도 일어날 수 있다.

  • PDF

Verification of experimental test for PSC-Steel-PSC hybrid beam using nonlinear FEM analysis (비선형 FEM 해석을 이용한 PSC-Steel-PSC 혼합구조 보의 휨 실험 검증)

  • Kim, Sang-Hyo;Won, Jung-Hun;Park, Se-Jun;Lee, Chan-Gu
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.517-520
    • /
    • 2009
  • 본 연구에서는 비선형 FEM 해석을 이용하여 PSC(Prestressed concrete)와 강으로 구성된 혼합구조 보의 휨 실험을 검증하였다. 혼합구조 보의 거동에 가장 큰 영향을 미치는 연결부는 Perfobond rib로 구성된 경우와 스터드로 구성된 경우를 고려하였다. 이종 재료가 접하는 경계면의 상호 작용에 대해 완전합성과 부분합성인 경우를 고려하여 혼합구조 보의 비선형 해석을 수행한 후 해석 결과와 실험 결과를 비교하였다. 하중-처짐관계, 파괴 형상 등의 해석 결과를 실험 결과와 비교한 결과, 부분합성을 고려한 모형이 실험 결과와 유사한 거동을 보였으며 또한 Perfobond rib를 갖는 실험체가 스터드를 갖는 실험체보다 해석 결과와 비교 시 안전측의 결과를 나타냈다.

  • PDF

Free Vibrations of Tapered Beams with Static Deflection due to Dead Load (사하중에 의한 정적 처짐을 갖는 변단면 보의 자유진동)

  • Lee, Byoung-Koo;Oh, Sang-Jin;Lee, Yong;Lee, Tae-Eun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.14 no.1
    • /
    • pp.87-93
    • /
    • 2001
  • 이 논문은 사하중에 의한 정적 처짐을 갖는 변단면 보의 자유진동에 관한 연구이다. 사하중이 작용하는 변단면 보의 자유진동을 지배하는 상미분방정식을 유도하고 이를 수치해석하여 최 저차 3개 모드의 고유진동수 및 진동형을 산출하였다. 수치해석 예제에서는 선형 변단면과 등분포 사하중을 채택하였다. 지점조건으로는 회전-회전, 회전-고정, 고정-고정 보를 채택하였다. 수치해석의 결과로 하중강도, 세장비 및 단면비가 고유진동수에 미치는 영향을 분석하였다. 사하중의 영향을 고려한 경우와 고려하지 않은 경우의 진동형을 서로 비교하였다.

  • PDF

Spatial Stability of Non-Symmetric Thin-Walled Curved Beams I : Aanlytical Approach (비대칭 단면을 갖는 박벽 곡선보의 안정성해석 I: 해석적 방법)

  • 민병철;김문영
    • Computational Structural Engineering
    • /
    • v.11 no.4
    • /
    • pp.239-251
    • /
    • 1998
  • 본 연구에서는 비대칭 박벽단면을 갖는 곡선보의 안정성해석을 수행할 수 있는 이론 및 엄밀해를 제시하기 위하여, 3차원 연속체로부터 유도된 평형방정식으로부터 선형화된 가상일의 원리를 적용하였다. 박벽단면의 구속된 ?(warping)과 곡률효과를 고려하고 유한한 회전각의 2차항을 포함하는 곡선보의 변위장을 도입하여 단면에 대해 적분함으로써 도심축에 대한 박벽 곡선보의 총포텐셜에너지를 유도하였다. 또한, 단순지지되고 일축대칭 단면을 갖는 박벽원형 곡선보의 면내 및 면외좌굴에 대한 엄밀해를 유도하기 위하여, 면내에 대해서는 균일압축을 받는 원형아치의 역대칭 좌굴모드에 대한 좌굴하중을 유도하고 면외좌굴에 대해서는 균일압축 및 순수휨을 받는 아치의 처짐함수를 가정하여 곡선보의 횡좌굴하중에 대한 일반해를 제시하였다.

  • PDF

A Parametric Study of Deflection Analysis of the Prestressed Beams using Finite Element Analysis (유한요소해석을 이용한 프리스트레스트 보의 처짐에 대한 변수 해석)

  • Park, Ha Eun;Choi, Jin Woong;Kim, Min Sook;Lee, Young Hak
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.1
    • /
    • pp.39-46
    • /
    • 2015
  • The purpose of this study is to analyze the deflection of the prestressed beams. In this paper, a finite element model for deflections of prestressed beams is presented. Proposed finite element model was verified comparing with existing experimental results, and it showed a good agreement with the experimental results. Also, a parametric study has been conducted to analyze the influence of eccentricity, span-depth ratio, and prestressing force. The finite element model results were compared with hand calculation results. Deflections were increased as the eccentricity decreases, the span-depth ratio increases, and the prestressing force decreases. Hand calculation overestimated the deflection when the eccectricity or prestressing force is too small.

An Experimental Study on the Fire Resistance of Composite Truss Beam (합성트러스 보의 내화성능에 관한 실험적 연구)

  • Park, Won-Sup;Kim, Heung-Youl;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.135-141
    • /
    • 2009
  • The composite truss has been widely used for tall buildings and long-span structures in North America. As compared with other similar structures, it has merits such as reduction of construction period, low span/depth ratio, low dead weight and so on. It has the most effective trait for structures with long span of 12~18m. After collapse of WTC, the fire resistance behaviors of structures have been actively conducted under various fire conditions in several country. This study showed that the surface temperature of steel member in the composit truss beam was reached to $700^{\circ}C$ under the fire condition of a short time. Under the same condition, the temperature in concrete was within $200^{\circ}C$. The composit truss beam with 20mm bracing was collapsed by rapid deflection after about 3minutes. However, the beams with 25mm, 35mm, and 45mm bracing were not collapsed, even though those were reached to deflection standard of L/20 within 15minutes.

New Suggestion of Effective Moment of Inertia for Beams Reinforced with the Deformed GFRP Rebar (이형 GFRP Rebar로 보강된 보의 유효단면이차모멘트 산정식 제안)

  • Sim, Jong-Sung;Oh, Hong-Seob;Ju, Min-Kwan;Lim, Jun-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.185-191
    • /
    • 2008
  • To fundamentally solve the problem of deterioration of concrete structures, it has been researched that the high durable concrete structure reinforced with the FRP rebar can be one of major solution to the newly-developed concrete structure. FRP rebar has lots of advantages such as non-corrosive, high performance and light weight against the conventional steel rebar. Among these kinds of FRP rebars, GFRP rebar has usually been considered as the best reinforcement because of its economic point of view. Even though the material capacity of the GFRP rebar was already investigated, there are some problems such as low modulus of elastic that will be cause for degrade of the serviceability of flexural concrete member reinforced with the GFRP rebar. Thus, the deflection characteristics of the GFRP rebar reinforced concrete structure should be considered then investigated. In this study, ACI 440 guideline (2003), ISIS Canada Design Manual (2001) and Toutanji et al. (2000) was considered for predicting the moment of inertia of the concrete beam reinforced with the GFRP rebar. And it was also evaluated that load-deflection relationship had a good accordance with the test and analysis result. In the result of this study, it could be estimated that the load-deflection relationship using the suggested equation of moment of inertia in this study indicated better accordance with the test result than that of the others until failure.

Structural assessment of Anti-Freezing Layer with use of Falling Weight Deflectormeter Deflection (Falling Weight Deflectormeter를 이용한 동상방지층의 구조적 특성 분석)

  • Lee, Moon-Sup;Kim, Boo-Il;Jeon, Sung-Il;Park, Hee-Mun
    • International Journal of Highway Engineering
    • /
    • v.12 no.2
    • /
    • pp.99-106
    • /
    • 2010
  • Until now, the thickness design of anti-freezing layer has been empirically conducted using the frost depth determined from the freezing index. This approach cannot consider the structural properties of anti-freezing layer, which can cause the over-design of pavement structure. This paper presents results of structural evaluation of anti-freezing layer using the Falling Weight Deflectormeter (FWD) deflections. The FWD testing was directly conducted on top of the subbase layer located at the embankment, cutting, and boundary area of each section. It is observed from this testing that the center deflections of pavement structure with anti-freezing layer are smaller than those without anti-freezing layer. The deflection reduction rates are 15~55% in the embankment, 11~64% in the cutting, and 2~38% in the boundary, respectively. It was also found that the use of antifree zing layer enables to reduce the Surface Curvature Index (SCI) values up to 24 percent. Fatigue lives show that pavement structure with antifreezing layer are about two times higher than the those without anti-freezing layer. This fact indicates that the anti-freezing layer should be considered as a structural layer in the asphalt pavement system.

The Shear-Properties of Reinforced Concrete Beams without Web Reinforcement (복부보강이 없는 철근콘크리트보의 전단특성)

  • 문제길;홍익표
    • Magazine of the Korea Concrete Institute
    • /
    • v.5 no.2
    • /
    • pp.151-161
    • /
    • 1993
  • 본 논문은 전단철근을 갖지 않는 비교적 짧은 지간의 철근콘크리트 보에서 전단특성을 규명하고 균열전단강도와 극한전단강도를 예측하기 위한 것으로 총30개의 보를 4 series로 나누어 실험을 수행하였다. 실험의 변수는 콘크리트의 강도, 전단지간-유효높이의 비, 인장철근량등이며, 실험과정을 통해 파괴형상, 처짐, 전단강도등을 측정하였다. 실험결과로부터 콘크리트의 강도가 커지고 철근량이 많아질수록, 그리고 전단지간이 짧아질수록 철근콘크리트 보의 균열 및 극한전단강도가 증가됨을 밝혔다. 또한, 실험성과를 회귀분석하여 균열전단강도와 극한전단강도 추정식을 제안하였다. 제안된 추정식에 의한 계산값과 실험성과를 비교 검토하여 그 상관성을 확인하였다.