• Title/Summary/Keyword: 보강 간격

Search Result 277, Processing Time 0.029 seconds

Treatment of Acromioclavicular Dislocation by Modified Phemister Operation Augmented with Coracoclavicular Sling (오구 쇄골간 슬링으로 보강된 변형 Phemister 술식을 이용한 견봉 쇄골 관절 탈구의 치료)

  • Kim, Deok-Weon;Kim, Sung-Tae
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.188-193
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the clinical and radiological results of a modified Phemister method reinforcing the 4 strands of an Ethibond sling for acromioclavicular joint dislocation. Materials and Methods: Between September 1999 and May 2007, 30 acromioclavicular joint dislocation cases underwent a modified Phemister method reinforcing the 4 strands of an Ethibond sling. The average follow-up period was 28.2 months (range: 24~33 months). Clinical outcomes were evaluated using the Weitzman classification; the state of coracoclavicular space reduction was done using radiologic findings. Results: According to the Weitzman classification, there were 24 excellent, 4 good and 2 fair case outcomes. The average coracoclavicular distance improved from 16.9 mm to 7.3 mm immediately after surgery. The average ratio of coracoclavicular distance comparing to the contralateral side at the final follow-up was 1.24 (range: 0.68~1.71). Complications included retraction of K-wires in 5 cases and restriction of joint motion in 4 cases. Conclusion: The modified Phemister operation using augmentation of the coracoclavicular ligament by 4 strands of Ethibond is an effective treatment modality in acromioclavicular joint dislocation.

A Study on the Topology Optimization of Nail Arrangement using Stiffened Shape Density (보강 형상밀도를 이용한 네일 배치의 위상최적화 연구)

  • Cho, Chung-Sik;Song, Young-Su;Lee, Su-Gon;Woo, Jae-Gyung;Choi, Woo-Il
    • The Journal of Engineering Geology
    • /
    • v.28 no.4
    • /
    • pp.605-618
    • /
    • 2018
  • Korea follows the slope design criteria during construction. It was enacted by the Ministry of Land, Transport and Maritime Affairs. There are cases where the Soil-nail is designed as a measure to secure slope stability. The arrangement of the soil-nail may be arranged at equal intervals or may be arranged differently depending on the soil failure model. The optimum design of the countermeasure method is determined by securing stability of the slope through optimization of dimensions and shape. However, when uniform nails are placed at low elevations in slopes, the standard safety factor is exceeded, which may hinder economic design. It is preferable to arrange the reinforcement of the nails over the entire slope. When the horizontal spacing of the nails was topology optimized according to the slope height, it was possible to minimize the amount of reinforcement while satisfying the standard safety factor. Since the active load is reduced in the section where the slope height is lowered, the safety factor after reinforcement may be excessively increased. Therefore, the phase optimization method is proposed as an economical optimal design method using the reinforcing shape density. In addition, a relational expression was designed to optimize the horizontal spacing by slope height.

Optimum Reinforcement Conditions of Large Diameter Reinforcement for Steep Slope of Conventional Railway Embankment under Train Loading (기존선 성토사면 급구배화를 위한 열차 하중 하 대구경 봉상보강재의 최적 보강조건)

  • Kwak, Chang-Won;Kim, Dae-Sang
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.11
    • /
    • pp.43-50
    • /
    • 2016
  • A reinforcement is required to ensure the structural safety in case of railway embankment excavation under railway load. A large diameter soil nailing with concrete wall is applied as the reinforcement method instead of the conventional soil nailing system. In this study, a series of 3 dimensional numerical analyses are performed to investigate the optimum reinforcement considering 15 different conditions based on the length, lateral spacing, diameter, and inclination of the reinforcement. The interface between soil nail and perimetric grout is considered by means of cohesion, stiffness and perimeter of the grout. 0.3 m of reinforcement diameter is assessed as the most appropriate based on the economical viewpoint though ground displacement decreases with the increase of diameter, however the difference of displacement is negligible between 0.4 m and 0.3 m of diameter. Surface settlement, lateral displacement of wall, and stress of reinforcement are calculated and economic viewpoint to reinforce embankment considered. Consequently, the optimum reinforcement conditions considering those factors are evaluated as 3 m in length, 0.3 m in diameter, 1.5 m in lateral spacing, and 10 degree of inclination angle in the case of 3 m of excavation depth. Additionally, inclined potential failure surface occurs with approximately 60 degrees from the end of nails and the surface settlement and wall lateral displacement are restrained successfully by the large diameter soil nailing, based on the result of shear strain rate.

Bearing Capacity of a Square Shallow Foundation with and without Geogrid Reinforcement (Geogrid보강 여부에 따른 정방형 얕은 기초의 지지력에 관한 연구)

  • 신방웅;김수삼
    • Geotechnical Engineering
    • /
    • v.10 no.3
    • /
    • pp.5-16
    • /
    • 1994
  • This paper presents a new method to improve the bearing capacity of a square shallow foundation placed on a sand layer reinforced with geogrids which shows promise for further field work. The geogrid reinforcement will be necessary in the case of machine foundation, embankments for railroads, and foundations of structures in earthquake-prone areas. The ultimate bearing capacity (UBC) for the unreinforced sand and reinforced sand has been compared. Also, the effect of length, spacing, width of reinforcement on increasing the UBC have been evaluated. Based on the present model test results, it appears that significant improvement in the UBC of medium sand can be achieved by geogrid reinforcement.

  • PDF

A Study on Behaviour of Sandy Ground Reinforced by Geotextiles with Equal Vertical Spacings (일정한 연직간격의 지오텍스타일로 보강된 모래지반의 거동에 관한 연구)

  • Joo, In-Gon;Park, Yong-Boo;Park, Jong-Bae
    • Land and Housing Review
    • /
    • v.2 no.1
    • /
    • pp.79-85
    • /
    • 2011
  • The bearing capacity of a soil can be improved by conventional ground improvement techniques such as stabilization and compaction methods. Recently, the use of geotextiles in improving the bearing capacity of soils has become popular because of the availability of durable and strong geosynthetic materials. In this paper, through the laboratory model tests on sandy ground reinforced by geotextiles with the strip footing under plane strain condition, the effects of bearing capacity improvement on the sandy ground and its behaviour were investigated.

An Experimental Study on the Structural Behavior of Concrete Columns Confined with Welded Reinforcement Grids (용접 띠철근 보강된 콘크리트 기둥의 역학적 거동에 관한 실험적 연구)

  • Choi, Chang-Sik;Saatcioglu, Murat
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.187-196
    • /
    • 1999
  • An experimental investigation was conducted to study the structural behavior of concrete columns confined with welded grids. The full-scale columns with different volumetric ratio, spacing and arrangement of welded reinforcement grids were tested under simulated seismic loading. The columns were subjected to constant axial compression of approximately 20% or 40% of their capacities accompanied by incrementally increasing lateral deformation reversals. The results indicate that the welded reinforcement grid can be used effectively as confinement reinforcement provided that the steel used, have sufficient ductility and the welding process employed does not alter the strength and elongation characteristics of steel. The grids improved the structural performance of columns, which developed lateral drift ratios in excess of 3% with the spacing and volumetric ratio of transverse reinforcement similar to those required by the ACI 318-95 Building Code. Drift capacity further increased when grids with larger number of cells were used. Furthermore, the use of grids reduced congesting of reinforcement while the dimensional accuracy provided perfect support to longitudinal reinforcement.

Performance Evaluation of Full Scale Reinforced Subgrade for Railroad with Rigid Wall Under Static Load (정하중 재하 시 실물 강성벽 일체형 철도보강노반의 성능평가)

  • Kim, Dae-Sang
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.3
    • /
    • pp.31-42
    • /
    • 2015
  • The Reinforced subgrade for railroad (RSR) was constructed for one way railway line with the dimension of 5 m high, 6 m wide and 20 m long to evaluate its performance under train design load. The RSR has characteristics of short length (0.3-0.4 H) of reinforcement and rigid wall, 30 and 40 cm vertical spacing of reinforcement installation. To enhance economics and constructability, three kinds of connections (welding, hinge & bolt, bold wire) were also designed to realize the integration between rigid wall and reinforced subgrade. Two times of static loading tests were done on the full size railroad subgrade. The maximum applied pressure was 0.98 MPa (the maximum test load 5.88 MN), which corresponds to 19.6 times of the design load for railroad subgrade, 50 kPa. The performance on the RSR was evaluated with the safety on the failure, subgrade bearing capacity and settlement, horizontal displacement of wall, and reinforcement strain. Based on the full scale test, we confirmed that the RSR with the conditions of 0.35 H (35% of height) short reinforcement length, hinge & bolt type connection for integration between rigid wall and reinforced subgrade, and 40cm vertical spacing of reinforcement installment shows good performance under train design load.

A Study on the Flexural Strength Capacity of Wall Stud Assembly (경량형강 스터드 벽체의 휨강도에 관한 연구)

  • Kwon, Young Bong;Chung, Hyun Seok;Kim, Gap Deuk
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.2
    • /
    • pp.109-116
    • /
    • 2003
  • An investigation on the structural behavior of cold-formed steel lipped C-section stud for interior walls or partitions was carried out. This experimental research was carried out to study the ultimate and service load capacity of stud assemblies that are subjected to lateral loads. Each test specimen consisted of three or four lipped C-section studs and two C-section tracks that restrained both ends. The major factors considered in this experiment were the perforation on the web, the connection of the bridge channel and the special clip. The effect of the plaster board and the ply wood, which were attached to the tension flange on the flexural strength, was also investigated. Thereafter, the test strength capacities were compared with the nominal strength, based on the AISI Specifications (1996).

An evaluation of compressive lap splice of the D22 rebar by concrete strengths (콘크리트 강도변화에 따른 D22mm 철근의 압축이음 성능 평가)

  • Lee, Sung-Ho;Chun, Sung-Chul;Oh, Bo-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1081-1084
    • /
    • 2008
  • Column specimens were constructed with main parameters significantly affecting the strength of the compression lap splice, such as lap length, spacing of lapped bars, amount and location of transverse reinforcements, and concrete strength. An experimental study has been conducted with column specimens in concrete strength of 40 to 60 MPa. Diameters of lapped reinforcing bars are 22 mm. An axial load was monotonically applied to the column specimens. All specimens failed in a brittle sudden manner and cover concrete was blasted out at maximum load. Compression lap splice strengths of specimens were evaluated from strains measured at the beginning of the lap length. Effects of the main parameters on the strengths of compression lap splice are assessed. Similarly to strengths of tension lap slice, the compression splice strength is found to be affected by lap length, spacing of lapped bars, transverse reinforcements.

  • PDF

A Comparative Study on the Shear-Strengthening Effect of RC Beams Strengthened by FRP (FRP로 보강된 RC보의 전단보강효과 비교연구)

  • 심종성;김규선
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.4
    • /
    • pp.101-111
    • /
    • 1998
  • This study presents test results of RC beams strengthened by carbon fiber sheet(CFS), carbon fiber reinforced plastics(CFRP) or glass fiber reinforced plastics(GFRP) for increasing shear resistance. Nineteen specimens were tested, and the test was performed with different parameters including the type of strengthening materials(CFS, GFRP, CFRP), shear-strengthening methods(wing type, jacket type, strip type), strip-spacing, strengthening direction of FRP. The test results show that shear-damaged RC beams strengthened by FRP(CFS, GFRP, CFRP) have more improved the shear capacity. The mathematical model based on plastic theory was also developed to predict shear strength of shear-damaged RC beams strengthened by FRP. The predictions using the mathematical model. are agreed with the observations from the observed shear strengths for 19 test beams.