• Title/Summary/Keyword: 병행가동

Search Result 28, Processing Time 0.022 seconds

A Study on the BEMS Installation and performance Evaluation Method for Energy Monitoring(Measuring) of New Building (신축건물 에너지효율관리를 위한 환경 및 에너지모니터링(계측) 방법론)

  • Kwon, Won Jung;Yoon, Ji Hye;Kwon, Dong Myung
    • Journal of Energy Engineering
    • /
    • v.27 no.2
    • /
    • pp.32-48
    • /
    • 2018
  • Monitoring of energy use should be a priority in order to efficiently manage building energy use. Energy use in buildings can be managed by dividing them into energy sources, uses, and ZONE. By energy source, electricity, gas, fuel, and district heating are supplied to run the building's facilities. The purpose can be divided into five main applications, including cooling, heating, lighting, hot water and ventilation, but not many elevators and electric heaters that are difficult to include in the five applications are classified. ZONE Star refers to the comparison or separate management of areas for which the purpose of the building is similar or different. In addition, energy efficiency management requires control of the temperature, humidity, and people who will be measuring energy in the building, and the recent problem of fine dust should directly affect the ventilation of the building.

Assessment of the Radiological Inventory for the Reactor at Kori NPP Using In-Situ Measurement Technology (In-Situ 측정법을 이용한 고리 원자로 방사선원항 평가)

  • Jeong, Hyun Chul;Jeong, Sung Yeop
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.2
    • /
    • pp.171-178
    • /
    • 2014
  • After the expiration of operating license of a plant, all infrastructures within the plant must be safely dismantled to the point that it no longer requires measures for radiation protection. Despite the fact that Kori 1 and Wolsong 1 are close to the expiration of their operating license, sufficient technologies for radiological characterization, decontamination and dismantling is still under development. The purpose of this study is to develop one of methods for radiological inventory assessment on measuring object by using direct measure of large component with In-Situ measurement technique. Radiological inventory was assessed by analyzing nuclide using portable gamma spectroscopy without dismantling reactor head, and the result of direct measurement was supplemented by performing indirect measurement. Radiochemical analysis were performed on surface contamination samples as well. During the study, radiological inventory of reactor vessel calculated expanding the result. Based on the result and the radioactivity variation of each radionuclides time frame for decommissioning can be decided. Thus, it is expected that during the decommissioning of plants, the result of this study will contribute to the reduction of radiation exposure to workers.

Effects of Virtual Reality Training Combined with Thermal Stimulation on Upper Extremity AROM and Function in Chronic Stroke Patients (열자극을 병행한 가상현실훈련이 만성 뇌졸중 환자의 위팔 능동가동범위와 기능에 미치는 영향)

  • Dong Hoon Kim
    • Journal of Korean Physical Therapy Science
    • /
    • v.30 no.1
    • /
    • pp.62-71
    • /
    • 2023
  • Background: This study was performed to evaluate the effects of Thermal stimulation combined virtual reality training (TV) on improvement of upper extremity AROM and function in patient with chronic stroke. Design: Two groups pre-post randomized controlled design. Methods: A single-blind, randomized controlled trial was conducted with 30 chronic stroke patients. They were randomly allocated two groups; the TV group (n=15) and Virtual Reality training group (VT) (n=15). The TV group received treatment for 30 min - 15 min of Thermal stimulation, and 15 min of VR training. The VT group received 15 min of VR training. Each group performed 30 minutes a day 3 times a week for 8 weeks. The primary outcome upper extremity AROM and function were measured by a active range of motion test, Manual Function Test (MFT) and Jebsen-Taylor hand function Test (JTT). The upper extremity active range of motion was evaluated using a digital dual inclinometer. MFT and JTT were used to evaluate the hand function. The measurement were performed before and after the 8 weeks intervention period. Results: Both groups demonstrated significant improvement of outcome in muscle strength and upper extremity function during intervention period. TV group revealed significant differences in AROM and upper extremity function as compared to the VT groups (p<.05). Our results showed that TV was more effective on upper extremity AROM and function in patients with chronic stroke. Conclusion: Both groups demonstrated significant improvement of outcome in muscle strength and upper extremity function during intervention period. TV group revealed significant differences in AROM and upper extremity function as compared to the VT groups (p<.05). Our results showed that TV was more effective on upper extremity AROM and function in patients with chronic stroke.

Comparison of the Effects of Spinal Manipulation Combined with Painkiller and Muscle Relaxant to Painkiller and Muscle Relaxant Alone on Pain, Lumbar Range of Motion, and Disability Index in Patients with Chronic Low Back Pain (진통제-근육이완제 복용 병행 척추교정과 진통제-근육이완제 복용이 만성허리통증 환자의 통증, 허리 관절가동범위, 장애 지수에 미치는 효과 비교)

  • Dong-Hwan Oh;Suk-Chan Hahm
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.2
    • /
    • pp.33-45
    • /
    • 2024
  • Purpose : This study aimed to compare the effects of spinal manipulation combined with medication on low back pain (LBP), range of motion, and disability in patients with chronic LBP. Methods : Twenty patients with chronic LBP were included in this study. The participants were randomly assigned to the spinal manipulation with medication group (n=10) or the medication only group (n=10). The intervention group received spinal manipulation for 15 minutes, twice a week, and took medication twice a day for eight weeks. The control group received the medication twice daily for eight weeks. Pain intensity assessed using the visual analog scale (VAS), range of motion, and disability due to LBP assessed using the Oswestry disability index were measured before and after the intervention. Results : The intervention group showed a significant improvement in pain intensity compared to the control group (p<.05), and the intervention and control groups significantly improved low back pain after the intervention (p<.05). The intervention group showed a significant improvement in the range of motion in flexion, extension, right lateral flexion, left lateral flexion, and right rotation (p<.05). The intervention group also showed a significant improvement in the change of disability in total score, pain intensity, personal care, lifting and standing compared to the control group (p<.05). Conclusion : This study showed that the combination of spinal manipulation and medication can benefit patients with chronic LBP, as evidenced by significant improvements in pain intensity, ROM, and disability. These findings suggest that utilizing both spinal manipulation and medication can positively affect individuals with chronic LBP. The results of this study should be applied in clinical settings to optimize treatment outcomes in patients with chronic LBP.

Actual Utilization and Thermal Environment of Greenhouses According to Several Cooling Methods during Summer Season (하절기 온실의 활용실태 및 몇 가지 고온극복 방법별 열환경 분석)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.9 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • This study was performed to find an efficient method to overcome extremely high temperature in greenhouses during summer season. The actual utilization of greenhouses during hot summer season showed that about 21.6% of the investigated greenhouse farms were in fallow state, and most of greenhouse farms were cultivated under the very inferior environment. Thermal environment of greenhouses according to the evaporative cooling method and several assistant cooling methods such as ventilation, shading screen, roof sprinkling were examined. As the each assistant cooling method was used, about 74.8%, 25.9%, and 58.2% of temperatures measured at intervals of ten minutes between ten and seventeen o'clock were above 35$^{\circ}C$. When shading screen and evaporative cooling system were operated, most greenhouse air temperatures were maintained below 35$^{\circ}C$, and showed a drop of 3.8~4.2$^{\circ}C$ as compared with naturally ventilated greenhouse.

  • PDF

Development of the Phased Array Ultrasonic Testing Technique for Nuclear Power Plant's Small Bore Piping Socket Weld (원전 소구경 배관 소켓용접부 위상배열 초음파검사 기술 개발)

  • Yoon, Byung-Sik;Kim, Yong-Sik;Lee, Jeong-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.368-375
    • /
    • 2013
  • Failure of small bore piping welds is a recurring problem at nuclear power plants. And the socket weld cracking in small bore piping has caused unplanned plant shutdowns for repair and high economic impact on the plants. Consequently, early crack detection, including the detection of manufacturing defects, is of the utmost importance. Until now, the surface inspection methods has been applied according to ASME Section XI requirements. But the ultrasonic inspection as a volumetric method is also applying to enforce the inspection requirement. However, the conventional manual ultrasonic inspection techniques are used to detect service induced fatigue cracks. And there was uncertainty on manual ultrasonic inspection because of limited access to the welds and difficulties with contact between the ultrasonic probe and the OD(outer diameter) surface of small bore piping. In this study, phased array ultrasonic inspection technique is applied to increase inspection speed and reliability. To achieve this object, the 3.5 MHz phased array ultrasonic transducer are designed and fabricated. The manually encoded scanner was also developed to enhance contact conditions and maintain constant signal quality. Additionally inspection system is configured and inspection procedure is developed.

Smoke Control Experiment of a Very Deep Underground Station Where Platform Screen Doors are Installed (I) - Analysis on Smoke Control Performance on the Platform (스크린도어가 설치된 대심도 지하역사의 제연 실험 I - 승강장에서의 제연의 효과 분석)

  • Park, Won-Hee;Kim, Chang-Yong;Cho, Youngmin;Kwon, Tae-Soon;Lee, Duck-Hee
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.7
    • /
    • pp.485-496
    • /
    • 2018
  • In this paper, the smoke behavior in an underground station on operation of the fans in the ventiliation of the station was measured by the experimental method when the fire occurred in the underground station platform where the platfrom screen door was installed. The ventilation characteristics were compared when the ventilation system was operated and when the ventilation system was not operated when a fire occurred at the platform where the clean door was closed. To simulate the fire smoke, the smoke generated from the smoke generator was heated using a hot air fan. The transmittance was measured using a smoke density meter to quantitatively measure fire smoke. If the screen door is closed and the ventilation system of the underground station does not work, it is confirmed that if a fire occurs in the platform, smoke accumulates inside the platform, evacuating passengers is very difficult and can lead to a very dangerous situation. On the other hand, under the condition that the ventilation facility of the subway station is operated, the smoke evacuates to the outside through the ventilation facility of the underground station, and airflow is formed in the direction from the waiting room to the waiting area, so that the passenger located on the platform can safely evacuate toward the concourse. In the following paper, we will discuss the concurrent effect of tunnel ventilation through tunnel vent near the platform.

Minimized Priming Volume for Open Heart Surgery in Neonates and Infants (신생아와 유아 심장 수술 시 심폐기회로 충진액의 최소화)

  • Kim, Woong-Han;Chang, Hyoung-Woo;Yang, Sung-Won;Cho, Jae-Hee;Lee, Kyung-Hoon;Baek, In-Hyuk;Kwak, Jae-Gun;Park, Chun-Soo;Lee, Jeong-Ryul;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.418-425
    • /
    • 2009
  • Background: Cardiopulmonary bypass (CPB) involves use of an initial priming volume which can cause side effects such as hemodilution, transfusion, inflammatory reaction and edema. Hence, there have been efforts made tore-duce the initial priming volume. We compared this traditional method to a CPB method that uses a minimized priming volume (MPV). Material and Method: For 97 patients who underwent congenital cardiac surgery between July 2007 to June 2008, we discussed each case and decided which method to use. We reviewed the medical records and cardiopulmonary bypass sheets of the patients. Result: We used a MPV method for 46 patients, and a traditional method for the other 51. There were no significant differences in preoperative and intraoperative characteristics between the two groups, such as body weight, age, cardiopulmonary bypass time, lowest body temperature, etc. However, the priming volume was much smaller in the MPV group than the traditional group (p<0.001). The volume of initially mixed packed RBC was also much smaller in the MPV group (p<0.001). There were no significant differences in postoperative mortality and neurologic complications. Conclusion: We could significantly reduce the initial priming volume and initially mixed pRBC volume with the revised CPB method. We suggest that this method be used more widely for congenital cardiac surgery.