• Title/Summary/Keyword: 병원 만족도

Search Result 1,497, Processing Time 0.023 seconds

TYPE II DENTINOGENESIS IMPERFECTA : CASE REPORT (Type II 상아질형성부전증의 임상 증례)

  • Kim, Chi-Hyun;Lee, Jae-Ho;Choi, Byung-Jai;Lee, Chong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.654-660
    • /
    • 2001
  • Dentinogenesis imperfecta is an example of an inheritable dentinal defect originating during the histodifferentiation stage of tooth development, with involvement of the primary and permanent teeth. Shields, Bixler and El-Kafrawy proposed three types of Dentinogenesis imperfecta : Type I, II, III. Witkop reported a prevalence of 1 in 8000 with the trait, and no significant difference between male and female. Affected teeth have red-brown discoloration often with distinctive wearness of occlusal surface of posterior teeth and incisal surface of anterior teeth. Once enamel seperated from underlying defective dentin, the dentin demonstrates significantly acclerated attrision. Radiographically, the teeth have thin roots, bulbous crown, cervical constriction, and obliteration of the root canals and pulp chambers. In primary dentition periapical lesions or multiple root fractures are often observed. In successive generations the phenotypes of discoloration and wearness of teeth occurred, and one of the patient's subships, 10 year-old sister, showed general discoloration of her teeth and mild wearness. In this case, a 4 year-old male reported to the Yonsei University Pedodontics clinic, with a chief complaint of discolored teeth. The teeth showed generally yellowish-brown discoloration and moderate wearness. In radiographic features, obliteration of pulp, bulbous crown, and short roots were observed. It was diagnosed as Dentinogenesis imperfecta. The posterior teeth were restored with Stainless Steel Crown, and defective incisors including left upper primary central incisor which was extracted due to a root fracture with Open-faced Stainless Steel crown.

  • PDF

A Study on the Patient Satisfaction Survey at the General Hospitals in Korea (국내 종합병원 환자만족도 조사현황 분석)

  • Lee, Sunhee;Kim, Ji In;Cho, Woohyun;Lee, Jijeon
    • Quality Improvement in Health Care
    • /
    • v.5 no.1
    • /
    • pp.42-57
    • /
    • 1998
  • Background : It is increasing the concern for patient satisfaction as a customer information. This study was planned to investigate the activities related to patient satisfaction survey at the Korean hospitals. Methods : We performed the nationwide survey on 235 general hospitals by using the self-administrated checklist from Sep. 9 to Oct. 9, 1996. The response rate were 50.2%. We analyzed the descriptive statistics and chi-square test by SAS software on 118 hospitals. Results : First of all, 62.7% of study hospitals showed to conduct the patient satisfaction survey, and most of hospitals which did not conduct it had a plan to do it within 5 years. The reason that hospitals did not conduct satisfaction survey was due to a lack of administrator's interest or adequate questionnaire form. Second, the bigger, public and being more located in the big city or opened more than 10 years, the more hospitals conducted the patient satisfaction survey. Also, patient satisfaction survey was mainly handled by planning dept. or administrative team. Third, most hospitals had their own way of making questionnaires without proving reliability and validity. The results of the survey were applied to hospital management timely, and were mostly reported to top manager level. Most CEO concerned about the results of satisfaction survey. Fourth, the staffs in charge of survey had problems such as skill related to data analysis and development of questionnaire and they suggested that this problems could be solved through inducing the implementation of the survey results on hospital management, support for the development of standardized questionnaires and increasing the top manager's interests. Fifth, most questionnaires composed of lots of questioning items on hospital equipments and environment, and kindness of hospital employee to patients. Conclusions : Although this study had some limitations in generalization due to low response rate in big hospitals, it is meaningful to find the present state and the problems related to patient satisfaction survey of the general hospitals. We can conclude that there are increasing the concern for patient satisfaction survey among the hospitals nationwide, and it can be needed for technical support related to development of survey tool or method.

  • PDF

Effects of Self Efficacy, Body Image and Family Support on Postpartum Depression in Early Postpartum Mothers (산욕초기 산모의 산후우울에 자기효능감, 신체상, 가족지지가 미치는 영향)

  • Lee, Ji-Won;Eo, Yong-Sook;Moon, Eun-Hye
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4011-4020
    • /
    • 2015
  • The purpose of this study was to determine the self efficacy, body image and family support affect on postpartum depression in early postpartum mothers. The data was collected 306 mothers on the first week after delivery from one hospital located in B city. The instruments were a survey of general characteristics, obstetrical characteristics, the Edinburgh Postnatal Depression Scale(EPDS), self-efficacy, body image and family support. Data was analysed using descriptive statistics, Pearson correlation coefficients, and stepwise multiple regression. The results revealed that the average item score of the EPDS was 6.09. The significant predictors of postpartum depression were body image, emotional state in pregnancy, and family support. These variables had a 38.4% explainability. The results indicate that the postpartum mothers should be screened for postpartum depression early in the postpartum period and it's necessary to implement nursing intervention focused on to enhance the body image and family support, especially the weak emotional state mothers in pregnancy.

Development of Hardware for the Architecture of A Remote Vital Sign Monitor (무선 체온 모니터기 아키텍처 하드웨어 개발)

  • Jang, Dong-Wook;Jang, Sung-Whan;Jeong, Byoung-Jo;Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2549-2558
    • /
    • 2010
  • A Remote Vital Sign Monitor is an in-home healthcare system designed to wirelessly monitor core-body temperature. The Remote Vital Sign Monitor provides accuracy and features which are comparable to hospital equipment while minimizing cost with ease-of-use. It has two parts, a bandage and a monitor. The bandage and the monitor both use the Chipcon2430(CC2430) which contains an integrated 2.4GHz Direct Sequence Spread Spectrum radio. The CC2430 allows Remote Vital Sign Monitor to operate at over a 100-foot indoor radius. A simple user interface allows the user to set an upper temperature and a lower temperature that is monitored with respect to the core-body temperature. If the core-body temperature exceeds the one of two defined temperatures, the alarm will sound. The alarm is powered by a low-voltage audio amplifier circuit which is connected to a speaker. In order to accurately calculate the core-body temperature, the Remote Vital Sign Monitor must utilize an accurate temperature sensing device. The thermistor selected from GE Sensing satisfies the need for a sensitive and accurate temperature reading. The LCD monitor has a screen size that measures 64.5mm long by 16.4mm wide and also contains back light, and this should allow the user to clearly view the monitor from at least 3 feet away in both light and dark situations.

Research on the Actual Condition of Working Conditions in the Small and Medium Clinics (중소 병.의원 근무환경 실태조사)

  • Cheol, Kweon-Dae;Mi, Jang-Myeong;Hei, Jang-Yun;Mo, Chung-Kyung;Sin, Kwak-Choong
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.55-65
    • /
    • 2005
  • Research of actual condition of working conditions in the small and clinics, in the Seoul metropolitan city and Kyeonggido province. With the health care environmental change such as a rapid increase of the elderly people, rapid increase of health promotion needs, it is necessary to analyse and identity of the actual condition of working conditions for present and new radiological technologist. Research of general characteristics for the present radiological technologist. To research of the status employment, business scope, pay, working conditions, radiation safety management, equipment, and category association. Defining the problems of related working conditions, radiation safety management for the comprehensive methods to promote the rights the radiological technologist. A proposal for establishment legislature and system of the actual condition in the hospital for radiological technologist. Estimation for the demand and supply numbers of present radiological technologist and improvement of employment relations. Improved and refined scope business and duty regulation related to radiological technologist. Application for the establishment and development of promotion rights to utilize as basic data in a legislative and system frame of reference to implement the radiological technologist.

  • PDF

Cosmetic Thoracic Sympathectomy for Palmar Hyperhidrosis using 2mm Thoracoscopic Instruments (다한증 환자에서 2 mm 흉강경 기구를 이용한 미용적 교감신경절제술)

  • 성숙환;최용수;조광리;김영태;김주현
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.525-530
    • /
    • 1998
  • Thoracoscopic thoracic sympathectomy for primary palmar hyperhidrosis has been known to be effective and to have cosmetic merits compared to conventional open sympathectomy. In spite of its cosmetic advantages over thoracotomy, VATS using 5 mm or 10 mm instruments still has the problem of operative wound as well as pain on trocar sites. Recently, 2 mm thoracoscopic instruments have been used. The purpose of this study was to examine the results of thoracoscopic sympathectomy for palmar hyperhidrosis with 2 mm thoracoscopic instruments. From January 1997 to April 1997, 46 patients underwent bilateral thoracoscopic sympathectomy with 2mm instruments at Seoul National University Hospital. T-2 ganglion was carefully dissected and resected out in all patients. In one patient, the lower third of T-1 ganglion was inadvertently resected together with T-2 ganglion due to poor anatomical localization. In 4 patients who also complained of excessive axillary sweating, T-3 ganglion was resected as well. The instruments were removed without leaving any chest drain after reexpansion of the lung. Trocar sites were approximated with sterile tapes. All patients were relieved of excessive sweating in their upper extremities immediately after the operation. Nine patients(19.6%) showed incomplete reexpansion of the lung, and two of them required needle aspiration. Complications related to the surgical procedures, such as Horner's syndrome, hemothorax, and brachial plexus injury, were not detected in any cases. Most patientsdid not complaine of pain. All patients were discharged from the hospital on the day of operation. Despite a narrow operative viewfield, thoracic sympathectomy with 2 mm thoracoscopic instruments can be performed without increasing any severe complications. We recommend 2 mm instruments for thoracoscopic sympathectomy because they make as the more cosmetic, less painful, and equally effective compared to thoracoscopic sympathectomy using 5 mm or greater instruments.

  • PDF

Coronary Artery Bypass Surgery in Patients with End-Stage Renal Disease (말기 신부전 환자에서의 관상동맥 우회수술)

  • Kim, Kun-Il;Song, Hyun;Yu, Yang-Gi;Jo, Min-Seop;Matsuda, Naruto;Sorokin, Vitaly A.;Choo, Suk-Jung;Lee, Jae-Won;Song, Meung-Gun;Yi, Joon-Seung;Kim, Soon-Bae;Park, Su-Kil;Park, Jung-Sik
    • Journal of Chest Surgery
    • /
    • v.34 no.4
    • /
    • pp.338-344
    • /
    • 2001
  • 배경: 말기 신부전 환자에서 심장병, 특히 관상 동맥 질환의 이환이 늘어나면서 관상동맥 우회수술의 대상 환자가 지속적으로 증가하고 있다. 이들 환자군은 수술후 유병률과 사망률이 매우 높고 고위험군으로 알려져 있다. 대상 및 방법: 1996년 3월부터 2000년 5우러까지 서울 중앙 병원 흉부외과에서 술전 말기 신부전증으로 진단 받은 후 관상 동맥 우회수술을 시행받은 환자 25명을 대상으로 의무 기록을 중심의 후향적 분석을 하였다. 술전 위험 인자 및 술전 신기능, 수술 결과, 술후 경과, 수술후 합병증, 사망률 및 생존률 등을 분석하였다. 결과: 술전 평균 크레아티닌 청소율은 12.7$\pm$5ml/mim였고 술전 평균 혈중 크레아티닌 치는 6.2$\pm$3mg/dl(1.7-14.4)였다. 술전 투석을 시행중인 환자는 11례(44%)였고 술전 투석을 시행하지 않았던 14례(56%)중 8례(8/14, 57.1%)는 수술전후로 새로이 투석이 필요하였다. 술전 혈액 투석 중이었던 9례중 2례에서 수술후 복막 투석으로 전환하였다. 수술 사망률은 2례(8%)로 흡인성 폐렴과 종격동염으로 1례, 그리고 수술후 출형과 종격도염으로 1례가 사망하였다. 수술후 합병증은 14명(56%)의 환자에서 발생하여 매우 높은 발생율을 보였다. 만기사항은 2례(8%)에서 발생하였으며 사망원인은 카테터에 의한 복막염이었다. 생존 환자의 4년 생존률은 82$\pm$13% 였다. 결론: 말기 신부전 환자에서의 관상동맥 우회수술을 비교적 만족스러운 범위의 수술 사망률(8%)을 보였으나 합병증 발생률이 매우 높고 합병증 발생 시 사망률이 매우 높아 수술주위 감염 예방과 세심한 환자 관리가 필요하다.

  • PDF

The Relationship Between Job Retainment and Job Satisfacion of Hospital Nurses. (병원 간호사의 장기근무유인과 직무만족과의 관계)

  • Lee, Hea-Won
    • The Korean Nurse
    • /
    • v.33 no.1
    • /
    • pp.65-79
    • /
    • 1994
  • The purpose of this study was to describe the job retainment factors and the level of job satisfaction, and to identify the relationship between job retainment and the level of job satisfaction among the registered nurses working in hospitals. Four hundred eight registered nurses currently employed at 8 hospitals in Seoul were surveyed for the study. The 39 item, 5 point likert scale questionnare was developed by the researcher. The internal consistency of job satisfaction was. 86 and that of job retainment was. 90 in Cronbach's alpha test. The data sas collected from July 15 to July 30, 1993. The SPSS/PC+statistical program was used for data analysis. The descriptive analysis of the characteristics of the subjects, the level of job satisfaction and the job retainment factors was done. The relationship between the job satisfaction level and the job retainment factors was tested with. the Pearson Correlation Coefficient analysis, and thd differences of job retainment scores among the sample was tested with t-test and ANDVA. The results of the study were summarized. 1. The mean age of the subjects was 29.7 years, 41.7% of them were married. 71.1% of them were 3 years course graduates, 71.8% of them were staff nurses, and the mean duration of experience was 6 years. 2. The factors related to professionalism(3.43), society(3.31), and interpersonal relationship(3.29) were significant in job retainment. The maximum score was 5.0 Two other factors, personal(3.05) and organization(2.83) factors, also showed relatively high scores. 3. The factors to the job satisfaction showed similar pattern as job retainment: professionalism (3.47), society (3.33), finance(3.31), interpersonal relationship(3.02), and organization(2.72). 4. Society related factors(r=.7420, p<.00l) and professionalism(r=.7249, p<.00l) had high correlation with job retainment. Personal(r=.6372, p<.001) and organizational(r=.3597, p<.001) factors had moderate relationship to job retainment. Finance(r=.3597, p<.00l) had significant but weak relationship to job retainment. 5. Age, marital status, job position, departmental involvement, experience, and continuity of employment of the sample showed significant differences in job retainment. However, the period of job retainment, number of children, educational level, type of hospital, previous employment experience were not significant. 6. lndiviuals older than 40 years of age, who were married, who held the position of charge or head nurse position, who worked in central supply or nursing administration showed significantly high job retainment score. This research indicates that the professionalism is the most significant factor in job retainment. In order to retain more experienced nurses, it is important to improve the profesionalism among nurses.

  • PDF

The Factors Related to Intractability in Patients with Partial Epilepsy (부분성 간질환자에서 난치성에 관여하는 인자)

  • Lee, Yeung-Ki;Byun, Yeung-Ju;Park, Mee-Yeong;Hah, Jung-Sang;Lee, Se-Jin
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.2
    • /
    • pp.306-318
    • /
    • 1995
  • To evaluate the intractability of partial epileptic patients by variables, the author studied 113 patients (uncontrolled: 45, controlled: 68) who were admitted to the Department of Neurology, College of Medicine, Yeungnam University from January, 1991 to August, 1993. The results were as follows. The items related to complex partial seizures, multiple seizure types and a histories of status epilepticus or clusters of seizures were significantly associated with drug-refractoriness (p<0.01). A high frequency of seizures before evaluation was associated with a poor outcome(p<0.01). The presences of known etiology of seizures, neurologic abnormalities and psychiatric disturbance were associated with limited treatment responses(p<0.01, p<0.05, p<0.01). An abnormal EEG findings such as background slowing, focal slowing, epileptiform discharges or secondarily bilateral synchrony were statistically significant (p<0.01). Age at onset, sex, distribution of epileptic foci, duration of seizure before evaluation, family history and abnormal neuroradiologic findings were not statistically significant. By these results, it was suggested that having at least four factors of the above variables were associated with limited treatment response.

  • PDF

Effect of Passive Layer to Improve Performance of Digital Dosimeter in Brachytherapy (방사선 근접치료 디지털 선량계의 성능 개선을 위한 Passive Layer의 효과)

  • Han, Moo-Jae;Yang, Seung-Woo;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.715-721
    • /
    • 2021
  • In radiation brachytherapy, the wrong source location may cause excessive dose to normal tissue. Therefore, research on digital dosimeters is being made to replace the analog detection method. Therefore, in this study, a lead (II) oxide (PbO) dosimeter applied with a passive layer (PL) was fabricated as a basic study to improve the dosimeter performance. Afterwards, reproducibility, linearity, and distance dependence were evaluated to analyze the performance of the Ir-192 source under irradiation conditions. The reproducibility of the PL-PbO dosimeter was 0.40%, which satisfies the evaluation criteria of 1.5%, and showed improved results compared to the PbO dosimeter. Linear function R2 showed excellent results as 0.9995, and slope analysis through regression analysis of the linear function was excellent in PL-PbO. The distance dependence of the PL-PbO dosimeter was +0.599 higher than that of PbO when the slope obtained through regression analysis of the power function was compared with the inverse square value. This study presents the effects and measurement variables according to the measurement configuration of the solid-state dosimeter, and can be used in various radiation detection fields.