• Title/Summary/Keyword: 병원 건물

Search Result 99, Processing Time 0.02 seconds

Scheduling Technique for Remodeling Project of Inhabited Condition (재실 리모델링 특성을 반영한 공정계획 기법)

  • Paik, Hwa-Sook;Nam, Wook-Jin;Kim, Sung-Han;Kim, Hyung-Jin;Choi, Jong-Soo;Kim, Kyung-Hwan
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.2
    • /
    • pp.141-149
    • /
    • 2013
  • This paper presents a scheduling technique that reflects various constraints in remodeling project of inhabited condition. The remodeling project of inhabited condition is required more detailed planning and control due to claims by noise, vibration, dust, smells, limited lift capacity, and limited temporary stock area. Because of the constraints, complexity in scheduling is increased and earlier completion is required to reduce the possibility of safety and environment accidents. Especially, in case of inhabited condition, the scheduling should be linked day-time/night-time/weekend work. This paper proposes a structured scheduling technique to incorporate those constraints in remodeling of inhabited condition. This scheduling technique considers not only remodeling process but also dismantling, newly-construction, and residents movement. Process expression method using MS-Project also presented to keep connectivity with existing scheduling system.

Optimization of Enzymatic Hydrolysis for the Production of Antitoxic Bovine Hepatic Extract (항독성 소간추출물의 생산을 위한 효소분해의 최적화)

  • Kim, Hyun-Jung;Kwon, Do-Hyeong;Shon, Dong-Haw
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.190-193
    • /
    • 2008
  • Bovine hepatic extract is recognized as possessing detoxifying activity against various liver diseases. In orderto develop a process for its mass production, various enzymatic hydrolysis conditions were tested, and bovine hepatic extracts were prepared. These extracts were then examined for composition, microorganism levels, and vitamin $B_{12}$ content. Among the enzymes tested, papain was selected based on yields for dry residue and amino nitrogen. The other enzymes tested included bromelain, ficin, pancreatin, and protease NP. The optimal hydrolysis conditions were established at 65$^{\circ}C$ for 24 hr, with an addition of 1%(w/w) papain to the beef liver. The prepared spray-dried bovine hepatic extract showed an 11% recovery yield on a raw beef liver basis, with 95% dry residue and 11.8% total nitrogen content. Microorganisms were not detected in the dried extract, and its vitamin $B_{12}$ content was 4.1 ${\mu}$g/g. In summary, the conditions established in this study could be applied for the high yield mass production of bovine hepatic extract.

Using frequency and needs for walking sphere of neighborhood facilities by the elderly - Focused on the elderly who lived in Busan - (노인의 근린생활시설 이용정도와 도보권 시설요구 - 부산지역 거주 노인을 중심으로 -)

  • Oh, Chan Ohk
    • Korea Science and Art Forum
    • /
    • v.20
    • /
    • pp.279-292
    • /
    • 2015
  • As the aging society is rapidly coming, the needs for the elderly-friendly living environments was also increasing. The purpose of this study was to examine how frequently 25 neighborhood facilities were used by the elderly and what facility they wanted to be arranged within their walking distance. The subject of this study were 158 elderlies who were their ages of more than 65 years and lived in Busan. The data were collected by using an one to one interview method. Findings were as follows; 1) The elderly used very frequently facility for the elderly such as a senior center, walking road, and park and green space. Also, bus stop, traditional market, and resting facilities were used relatively frequently. 2) Some neighborhood facilities were used not frequently, but periodically. 3) Using frequencies of some neighborhood facilities were different by the elderly's characteristics. 4) Among 25 neighborhood facilities, the facilities which the old persons wanted to be arranged within walking distance were medical clinics, facilities for the elderly, subway station, bus stop, traditional market, park and green space, walking road, and food market/convenience store.

Cooling Performance of Cooling Tower-Assisted Ground-Coupled Heat Pump (GCHP) System Applied in Hospital Building (병원 건물에 설치된 냉각탑 병용 지열 히트펌프 시스템의 냉방 성능)

  • Sohn, Byonghu;Lee, Doo-Young;Min, Kyung-Chon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.1
    • /
    • pp.7-16
    • /
    • 2016
  • This paper presents the measurement and analysis results for the cooling performance of ground-coupled heat pump (GCHP) system using a cooling tower as a supplemental heat rejector. In order to demonstrate the performance of the hybrid approach, we installed the monitoring equipments including sensors for measuring temperature and power consumption, and measured operation parameters from May 1 to October 30, 2014. The results showed that the entering source temperature of brine returning from the ground heat exchanger was in a range of design target temperature. Leaving load temperatures to building showed an average value of $11.4^{\circ}C$ for cooling season. From the analysis, the daily performance factor (PF) of geothermal heat pumps ranged from 4.4 to 5.2, while the daily PF of hybrid GCHP system varied from 3.0 to 4.0 over the entire cooling season.

A Location Based Service with Mobile PC (모바일 PC를 사용한 위치 기반 서비스)

  • Park, Jun-Sung;Roh, Young-Tae;Lee, Jun;Park, Sung-Jun;Kim, Jee-In
    • 한국HCI학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.348-353
    • /
    • 2007
  • 사회구조가 고도화됨에 따라서 사용자들은 크고 복잡한 환경에 노출되고 있다. 이러한 환경은 사용자들이 자신의 위치가 어디인지를 인식하게 어렵게 하고 있다. 그에 따라서 사용자에게 지도나 키오스크 시스템[1]과 같은 위치 안내 서비스를 제공하고 있다. 하지만 이런 서비스는 2D 기반의 안내를 하기 때문에 사용자가 직관적, 공간적으로 자신의 위치를 파악하기란 어렵다. 직접 시스템에 찾아가야 서비스를 사용할 수 있으며, 서비스의 제공이 지속적이지 않고, 순간적이라는 단점이 있다. 본 논문에서는 사용자가 이동하면서 자신이 찾고자 하는 위치에 대한 안내를 3D 가상현실 기반의 위치 안내를 받을 수 있는 모바일 PC를 위한 위치 기반 서비스(Location Based Service)를 제공한다. 제안하는 시스템은 사용자의 현재의 위치를 인식하기 위해서 모바일 PC에 GPS와 RFID태그를 이용한다. 이를 실내외 공간에서의 위치를 인식을 하게 되며, 사용자의 현재 위치에서 자신이 가고자 하는 목표장소에 대한 최단 경로를 알려 준다. 뿐만 아니라 여러 장소를 방문하는 경우, 미리 만든 스케쥴에 따라서 위치 안내 서비스를 받을 수 있다. 제안하는 시스템은 사용자가 전시장, 병원, 관공서 등의 건물에서 원하는 위치를 자신이 있는 위치에서 편하고 간편하게 찾아 줄 수 있으며, 부가적으로 다양한 위치 기반 서비스들이 적용 가능하다.

  • PDF

An Experimental Study to Develop the Perforated Panel System for Noise Chamber (소음쳄버용 다공판 시스템 개발을 위한 실험적 연구)

  • Lee, Young-Sup;Lee, Dong-Hoon;Chung, Kwang-Seop
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.806-810
    • /
    • 2009
  • The air conditioner system that is used in large structure, such as hospital, hotel, railway platform and train generate a high level noise generally. A chamber with sound absorbing materials, such as glass wool and polyurethane foam, are installed in this system to reduce the noise. However, these chambers cause environmental problems owing to the sound absorbing materials recently. Therefore, we develop noise chamber a built-in perforated panel resonance system as eco-friendly chamber to solve this problems. This noise chambers show the same noise reduction performance as the current chambers in the range above 500Hz. But, it reduces the noise up to 8dB(A) comparison to the current chambers in the range 200Hz~400Hz.

A Study on simulation analysis of the microbe transport of air-born virus in hospital for microbiological safety (미생물 안전을 위한 병원건물의 환기설계에 따른 공기 감염균 확산에 관한 시뮬레이션 연구)

  • Choi, Sang-Gon
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.4
    • /
    • pp.115-123
    • /
    • 2017
  • Recently there is a growing interest in the airborne spread of virus. In particular, there is growing interest in secondary infection through the air in the hospital. The distribution of air-born virus depends on ventilation system installed in a hospital. In this study, simulations were carried out to predict the move of air-born virus by ventilation system at hospital. Simulation results showed that pressure distribution was -372.05Pa ~ -3.45 Pa at 1st floor incase of only used mechanical exhaust at bathroom, shower stall, storage, kitchen etc.. if ventilation switch from used mechanical exhaust to mechanical exhaust & mechanical supply. Simulation results showed that pressure distribution was -336.44Pa at stair hall < -0.2Pa at bathroom < mean 1.19Pa at other room. So simulation results showed that using all of the mechanical supply and mechanical exhaust was more effective then the mechanical exhaust for maintain the pressure distribution in hospital. It was also showed that when using the mechanical supply and mechanical exhaust more effectively prevention of air born virus diffusion.

A Study on the Health Risk Agents in the Workplace of a General Hospital (한 종합병원 작업환경의 건강저해인자에 관한 조사 연구)

  • Kim, Yang-Ok;Kim, Ki-Soon;Park, Jong;Ryu, So-Yeon;Yang, Hee-Yeon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.1 s.52
    • /
    • pp.1-14
    • /
    • 1996
  • To evaluate the health risk of the workplace environment of a general hospital toward the hospital workers, a questionnaire survey on the perception of risk at the workplace environment and environmental measurements at 27 locations with 240 workers in the hospital were made from October 25th, 1993 to October 30th, 1994. The results were as follows ; 1. By the environmental measurements, 86 workers(36%) were found to be exposed to poor or harmful degree of general illumination, 193 workers(80%) were exposed to poor or harmful local illumination, 34 workers(14%) were exposed to poor or harmful degree of thermal condition and 180 workers(75%) were exposed to poor or harmful noise level, but nobody was exposed to poor or harmful dust and toluene concentration. Also nobody was exposed to poor or harmful level of radiation or anticancer/antibiotic agents. 2. The subjective perceptions on the environmental conditions felt by the workers were different from the objective findings by the environmental measurements. The workers underscored the poor illumination state and overscored the dust concentrations. Also workers oversensitized about the thermal condition, the noise level, the radiation level, the toluene concentration and anticancer/antibiotic agents 3. The sources of noise were the dialogue(179 workers) and the office instruments(131 workers). The sources of dust came from the clothes(108 workers) and the building materials(79 workers). 4. The questionnaire survey showed that the 28 workers were exposed to poor or harmful level of the antibiotics, 10 workers to alkali or acid and 6 workers to drug dust in the pharmacy but the above findings could not be proved by the environmental measurements.

  • PDF

Study of the Residential Environment and Accessibility of Rehabilitation for Patients with Cerebral Palsy (뇌성마비 환자의 주거 환경과 재활 접근성에 관한 연구)

  • Cho, Gyeong Hee;Chung, Chin Youb;Lee, Kyoung Min;Sung, Ki Hyuk;Cho, Byung Chae;Park, Moon Seok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.309-316
    • /
    • 2019
  • Purpose: This study examined the residential environment and accessibility of rehabilitation for cerebral palsy (CP) to identify the problems with residential laws pertaining to the disabled and provide basic data on the health legislation for the rights of the disabled. Materials and Methods: The literature was searched using three keywords: residence, rehabilitation, and accessibility. Two items were selected: residential environment and rehabilitation accessibility. The questionnaire included 51 items; 24 were scored using a Likert scale and 27 were in the form of multiple-choice questions. Results: This study included 100 subjects, of which 93 lived at home and seven lived in a facility. Of these 93 subjects, 65% were living in apartments, usually two or more floors above ground, and 40% of them were living without elevators. According to the Gross Motor Function Classification System, subjects with I to III belonged to the ambulatory group and IV, V were in the non-ambulatory group. Subjects from both groups who lived at home found it most difficult to visit the rehabilitation center by themselves. In contrast, among those who lived at the facility, the ambulatory group found it most difficult to leave the facility alone, while the non-ambulatory group found it most difficult to use the toilet alone. Moreover, 83% of respondents thought that rehabilitation was necessary for CP. On the other hand, 33% are receiving rehabilitation services. Rehabilitation was performed for an average of 3.6 sessions per week, 39 minutes per session. Conclusion: There is no law that ensures secure and convenient access of CP to higher levels. Laws on access routes to enter rooms are insufficient. The disabled people's law and the disabled person's health law will be implemented in December 2017. It is necessary to enact laws that actually reflect the difficulties of people with disabilities. Based on the results of this study, an investigation of the housing and rehabilitation of patients with CP through a large-scale questionnaire will necessary.

Investigation of Bacterial Contamination of Liquid Soaps Used in Public Restroom (공공 화장실에서 사용하는 액체 손세정제의 세균 오염도 조사)

  • Hong, Seung Bok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.3
    • /
    • pp.214-220
    • /
    • 2020
  • Handwashing with soap is an important practice to reduce the transmission of potentially pathogenic microorganisms, but liquid soaps with refillable dispensers are prone to extrinsic bacterial contamination. This study investigated the bacterial contamination of liquid soaps in 58 public restrooms in six buildings. The bacteria were identified by a biochemical test and MALDI-TOF mass spectrophotometry. The antimicrobial susceptibility was determined using the Vitek II system. Of the 58 restrooms examined, 27(46.55%) were using a refill dispenser, of which 25(92.59%) were contaminated with bacteria. The bacteria recovered from the soaps ranged from 1.6×103 to 2.7×105 CFU/mL. Serratia liquefaciens (12), Achromobacter xylosoxidans (9), S. marcescens (4), Staphylococcus pastueri (1), and Achromobacter spanius (1) were isolated. Except for one A. xylosoxidans, bacteria of the same species isolated in the same building showed a unique resistance pattern. In conclusion, handwashing with contaminated soap may play a role in the transmission of bacteria in public health settings. Therefore, it is necessary to limit the use of refillable liquid soaps in the restrooms of hospitals used by patients with reduced immunity.