• Title/Summary/Keyword: 변위특성

Search Result 1,827, Processing Time 0.033 seconds

Structural Capacity Evaluation of Hybrid Precast Concrete Beam-Column Connections Subjected to Cyclic Loading (반복하중을 받는 하이브리드 프리캐스트 보-기둥 접합부의 성능평가)

  • Choi, Hyun-Ki;Yoo, Chang-Hee;Choi, Yun-Cheul;Choi, Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.325-333
    • /
    • 2010
  • In this study, new moment-resisting precast concrete beam-column joint made up of hybrid steel concrete was developed and tested. This beam-column joint is proposed for use in moderate seismic regions. It has square hollow tubular section in concrete column and connecting plate in precast U-beam. The steel elements in column and beam members were connected using bolt. Furthermore, in order to prevent the premature failure of concrete in hybrid steel-concrete connection, ECC(engineered cementitious composite) was used. An experimental study was carried out investigating the joint behavior subjected to reversed cyclic loading and constant axial compressive load. Two precast beam-column joint specimens and monolithic reinforced concrete joint specimen were tested. The variables for interior joints were cast-in-situ concrete area and transverse reinforcement within the joint. Tests were carried out under displacement controlled reverse cyclic load with a constant axial load. Joint performance is evaluated on the basis of connection strength, stiffness, energy dissipation, and displacement capacity. The test results showed that significant differences in structural behavior between the two types of connection because of different bonding characteristics between steel and concrete; steel and ECC. The proposed joint detail can induce to move the plastic hinge out of the ECC and steel plate. And proposed precast connection showed better performance than the monolithic connection by providing sufficient moment-resisting behavior suitable for applications in moderate seismic regions.

Characteristics of Fracture Systems in Southern Korea (우리나라 단열구조의 특성)

  • 김천수;배대석;장태우
    • The Journal of Engineering Geology
    • /
    • v.13 no.2
    • /
    • pp.207-225
    • /
    • 2003
  • According to the data analysis of the regional fracture systems in southern Korea, the fracture orientations show three dominant sets : NNE, NW and WNW. A NNE set is the most abundant and includes most of the largest fractures. The highest fracture density is shown in the Taebaegsan mineralized area corresponding to Ogchon nonmetamorphic belt and the lowest one in the southwestern area of southern Korea. In addition, the density is higher in nonmetamorphic sedimentary rocks such as Choseon Supergroup. Pyeongan Supergroup, Daedong Supergroup and Kyeongsang Supergroup than in Precambrian basements and Jurassic granites. The regional fractures in southern Korea can be classified into four orders designated $F_1,{\;}F_2,{\;}F_3{\;}and{\;}F_4${\;}and{\;}F_4$ on the basis of their trace length. It is quite significant that fractures of each order are self-similar with respect to orientation and the combined fracture length distribution indicates a power-law distribution with an exponent of -2.04. As fractures were analyzed based on the tectonic provinces, Gyeonggj Massif and Kyeongsang Basin have all orders of fractures from $F_1$ to $F_4$. Most of the large scale faults may be ascribed to the products of slip accumulation through multiple deformation. Others besides $F_1$ fractures are thought to be evenly distributed through the whole area of southern Korea.

Design Considerations and Pull-Out Behavior of Mechanical Anchor of Reinforcement (철근 기계적 정착장치의 설계 고려사항과 인발특성)

  • 천성철;김대영
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.6
    • /
    • pp.593-601
    • /
    • 2001
  • In RC structure, sufficient anchorage of reinforcement is necessary for the member to produce the full strength. Generally, conventional standard hook is used for the reinforcement's anchorage. However, the use of standard hook results in steel congestion, making fabrication and construction difficult. Mechanical anchor offers a potential solution to these problems and may also ease fabrication, construction and concrete placement. In this paper, the required characteristics and the design considerations of mechanical anchor were studied. Also, the mechanical anchor was designed according to the requirements. To investigate the pull-out behavior and properness of mechanical anchorage, pull-out tests were performed. The parameters of tests were embedment length, diameter of reinforcement, concrete compressive strength, and spacing of reinforcements. The strengths of mechanical anchor were consistent with the predictions by CCD method. The slip between mechanical anchor and concrete could be controlled under 0.2mm. Therefore, the mechanical anchor with adequate embedment could be used for reinforcement's anchorage. However, it was observed that the strength of mechanical anchors with short spacing of reinforcements was greatly reduced. To apply the mechanical anchor in practice (e.g. anchorage of the beams reinforcements in beam-column joint), other effects that affect the mechanical anchor mechanism, such as confinement effect of adjacent member from frame action or effects of shear reinforcement, should be considered.

An Experimental Study of Strength Evaluation in Frozen Soils according to Direct Shear Box Systems (직접전단상자 시스템에 따른 동결토의 강도 평가에 관한 실험적 연구)

  • Kim, Sang Yeob;Kim, YoungSeok;Lee, Jangguen;Lee, Jong-Sub
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.3
    • /
    • pp.5-14
    • /
    • 2017
  • Experimental study on strength characteristics of frozen soils is necessary for the safety evaluation of design and construction in cold region. The objective of this study is to evaluate the direct shear strength of frozen soils obtained from traditional system (Type-1), system with roller on the upper shear box (Type-2), and system with fixed upper shear box separated from bottom shear box (Type-3). Specimens mixed with sand, silt, and water are frozen to $-5^{\circ}C$, and then direct shear tests are conducted under the normal stress of 5, 10, 25, and 50 kPa. Experimental results show that the upper shear box of Type-1 touches the bottom shear box due to the rotation of the upper shear box. The shear strength obtained from Type-2 is overestimated because the preventing rotation force is added to shear force. Type-3 may acquire the only strength of the specimen, and shear strain at peak shear strength is similar to that at the beginning of vertical displacement occurrence. In addition, internal friction angle and cohesion at both peak and residual stresses in Type-3 are smaller than those of Type-2. This study shows that high strength specimens including frozen soils can be effectively evaluated using improved shear box system such as Type-3.

A Study on the Geomorphology and Activity of Jinbu Fault in Pyeongchang-gun, Gangwon Province (강원도 평창군 진부 단층의 지형 및 활동성)

  • Lee, Gwang-Ryul;Cho, Young-Dong;Kim, Dae-Sik
    • Journal of the Korean Geographical Society
    • /
    • v.43 no.6
    • /
    • pp.775-790
    • /
    • 2008
  • This study shows possibility of active fault, throughout analyzing distributional features of tectonic and fluvial geomorphology and mineral composition of fault fracture clay, at Jinbu fault-line system in Pyeongchang-gun, Gangwon Province. Fault-line valley was formed remarkably in the upper reaches of Odae River and upper reaches of Yeongok River according along Jinbu fault-line. Landforms show rectilineal distribution at right shore slopes of Odae River in Ganpyeong-ri, southern zone of Jinbu fault-line system, related to the tectonic processes, such as triangular facet, kernbut, kerncol and alluvial fan. Fault fracture clay zones were developed at 5 outcrops($jbf1{\sim}5$), located in kerncol. Particularly, jbf1 fault outcrop, developed at granite saprolite, has obvious fault plane and fault clay composed of illite and laumontite. The Jinbu Fault-line along jbf4-2-3-5 may be formed by regional compressive stress, and jbf1 fault may be suggested a tributary fault of the Jinbu fault-line formed before the late Pleistocene. The vertical displacement of the east and west blocks of the Jinbu Fault-line is estimated in $0.024{\sim}0.027m/ka$.

Ultimate Capacity of Guardrail Supporting Pile Subjected to Lateral Impact Load Using Centrifuge Model Test (원심모형실험을 통한 차량방호울타리 지지말뚝의 수평방향 충격하중에 대한 극한지지력)

  • Yun, Jong Seok;Lee, Min Jy;Choo, Yun Wook
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.11
    • /
    • pp.25-36
    • /
    • 2019
  • The safety barrier is installed on road embankment to prevent vehicles from falling into road side slope. Among the safety barrier, flexible guardrails are usually installed. The flexible guardrail generally consists of a protection cross-beam and supporting in-line piles. These guardrail piles are installed nearby slope edge of road embankment because the side area of the road is much narrow. The protection cross-beam absorbs impact energy caused by vehicle collision. The pile-soil interaction also absorbs the rest of the impact energy and then, finally, the flexible guardrail system resists the impact load. This paper aims to investigate the pile-soil interaction subjected to impact load using centrifuge model tests. In this study, a single pile was installed in compacted residual soil and loaded under lateral impact load. An impact loading system was designed and developed available on centrifuge tests. Using this loading system, a parametric study was performed and the parameters include types of loading and ground. Finally, the ultimate bearing capacity of supporting pile under impact load was analyzed using load-displacement curve and soil reaction pressure distributions at ultimate were evaluated and compared with previous studies.

Finite Element Analysis on the Behavior of Soyanggang Dam and its Comparison with Observed (소양강(昭陽江)댐의 거동(擧動)에 대한 유한요소해석(有限要素解析)과 실측치(實測値)와의 비교(比較))

  • Kim, Sang Kyu;Lim, Heui Dae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.141-150
    • /
    • 1987
  • The Soyanggang Dam completed in 1973 was well instrumented during construction period. The measured results for stresses and movements of the embankment have already been published elsewhere, but theoretical analyses have not been made until now. This study intends to analyze the stress and deformation behavior of the embankment numerically which have been subjected to the load of materials during construction and water load during impounding. The constitutive law used for the analyses is hyperbolic model developed by Duncan et al., and a nonlinear incremental finite element analysis simulating its contruction steps is. used in this study. Hyperbolic parameters for each Zone are estimated from literature. The results obtained from the theoretical analyses clearly show deformation characteristics and stress vectors in arbitrary section of the dam. The analytical results ate well agreed with the measured deformations at the maximum cross section, however, there are some discrepancy in horizontal movements and in stresses generated in the core zone. From the numerical analyses and its comparison with the measured values, it is charaterized that relatively large construction settlements occurred in core zone, overburden pressure in the core zone was considerably reduced by arching effect, and tension zones might occur near both abutments because of the large horizontal displacement.

  • PDF

An Experimental Study of Sand Beach Profile Evolution under Regular Waves Corresponding to Storm and Normal Conditions (규칙파 조건에서의 사질해안 폭풍파와 평상파 단면변화 실험연구)

  • Choi, Junwoo;Roh, Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.333-342
    • /
    • 2017
  • In order to understand the mechanism of the cross-shore evolution of storm (barred) and normal (nonbarred) profiles of a sandy beach, the vertically two-dimensional laboratory experiment was performed with a movable bed. The beach profiles and free surface motion were measured under monochromatic wave conditions evolving the storm and normal beach profiles. The observation was conducted in the surf zone during the alternation of the two wave conditions to reach its quasi-equilibrium state. The sandbar-crest and trough and the steep berm were evolved due to the plunging breakers in the storm case, and the bar-trough was decayed due to the spilling breakers in the normal case. From the measurements, it was found that the storm wave case was in an erosion state and the normal wave case was in an accretion state. The strong undertow, which is a dominant factor of the offshore migration mechanism, was developed in the storm wave case, and the weak undertow was developed in the normal wave case. The skewness and the asymmetry of the nonlinear wave motion, which is a dominant factor of the onshore migration mechanism, was measured similarly in both cases.

Analysis of a Load Carrying Behavior of Shear Connection at the Interface of the Steel-Concrete Composite Beam (합성보 전단연결부의 구조거동에 대한 비교 분석)

  • Shin, Hyun Seop
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.6 s.79
    • /
    • pp.737-747
    • /
    • 2005
  • The connection of the slab with the steel beam and thus, the transmission of shear force at the interface of the steel-concrete composite beams is achieved with shear connectors, in general, with shear studs. The composite action through these shear studs has a significant influence on the load carrying behavior of the composite beams. The load carrying capacity of studs is determined through push-out tests. At present, the transferability of this load carrying capacity of studs to composite beams, especially in cases of partial interaction, is being questioned by experimental and theoretical investigations. In this study, a finite element model for the simulation of the behavior of the standard push-out specimen and the composite beams without the implementation of the load-slip curve of the stud connectors from the push-out test is developed. The load carrying behavior of the studs in the composite beams is estimated and compared with the results of the push-out test. The reason for the difference in the load carrying behavior of the studs in the push-out test specimen and in the composite beams is found.

The Experimental Study of Distribution Life-Force Impact on Piles and Landing Pier (잔교식 안벽의 상부와 Pile에 작용하는 파압분포에 관한 실험적 연구)

  • Park, Sang-Kil;Kim, Ki-Hyun;Kim, Woo-Seang;Park, Byung-Yul;Kang, Deok-Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.552-556
    • /
    • 2006
  • 항만건설에 있어서 항만의 내부시설 중에서 무엇보다도 가장 중요한 시설물은 선박을 안전하게 접안시켜 하역할 수 있는 안벽시설물이다. 안벽구조 형식의 결정은 항만의 이용목적 등에 따라서 달라지지만 항만의 건설입지조건 등에 의해서도 달라진다. 안벽구조형식 중에서 잔교 식 안벽은 무엇보다도 단기간에 건설이 용이하여 지금까지 각국에서 널리 사용되어 왔고 장래에도 이용도가 증가되리라 생각한다. 최근에는 해안선을 이용한 위락시설이 건설되면서 잔교 식 안벽구조물을 설치하여 보조시설물로 이용하는 경우가 많다. 과거에 설계되어 잔교를 설계할 경우는 일반적으로 항내의 정온이 잘 유지되는 경우에 대해서 설치하는 경우가 많기 때문에 파랑에 의한 반사율과 잔교 상부에 작용하는 양압력을 고려해야할 필요성이 거의 없었다. 그러나 최근에는 태풍이 내습할 경우 기존의 항내로 높은 파랑이 침입하는 경우가 발생하고 있어 항내에서도 잔교의 파괴로 인한 자연재해가 대형화되는 경우가 발생하고 있다. 또, 처음부터 안벽을 설계할 때에 대형화의 잔교 식 안벽구조물을 설치하는 경우도 있다. 이런 잔교 식 안벽 구조물을 잔교의 상부 판에 작용하는 양압력 분포와 잔교 전면의 반사율 등이 구조물의 유지관리 등에 미치는 영향이 매우 크기 때문에 반사율 검토와 양압력을 고려한 설계가 필요하다. 본연구의 대상은 일정 해역에 잔교 식 안벽을 설계하고자 할때 최적의 안벽 설계가 될 수 있도록 수리모형실험을 실시하여 구조물의 안전과 항내정온에 기초가 되는 자료를 도출하고자 하였다. 따라서 본 수리모형실험으로 인한 연구는 잔교 식 안벽에 대한 반사율과 상부에 작용하는 양압력, 잔교말뚝(pile)에 작용하는 수평압력을 검토하여 잔교 식 안벽 설계에 기초자료를 제공하고자 한다. 혈청을 이용한 동결보존을 대체할 수 있을 것으로 생각된다.지에 더해주면 세포의 증식이 개선될 것이다. 그래서 몇 가지 첨가물을 이용해 세포의 증식력에 변화가 나타나는지 알아보았다. 첨가물을 이용한 실험에서 IGF-I의 경우 장기간 배양에서 세포의 수를 안정적으로 유지하고 계대 횟수를 증가시키는 효과를 보였다. 이는 IGF-I이 어느정도 세포의 증식을 유지시켜주는 역할을 하기 때문인 것으로 생각된다. 무혈청 배지에서 비적응 CHO 세포의 계대 배양에 한계가 있는 것은 세포주기가 멈추기 때문인 것으로 생각된다. 세포주기가 멈추는 growth factor와 같이 세포의 증식을 지속적으로 유도할 수 있는 물질이 무혈청 배지에서는 부족하기 때문인 것으로 생각되고, IGF-I과 같은 첨가물을 통해 극복할 수 있는 문제라고 여겨진다.관점과 주거교육가치관 요소와의 관계를 알아본 결과, 전통적 관점은 주거교육가치관 요소 중 오직 주거관리적 요소와 관계가 있었으나 그 정도는 낮으며 실천적 관점과 구조적 관점은 주거가치관의 각 요소에 따라 약간 다르기는 했으나 주로 보통의 관계를 보였다.군 순으로 높게 관찰되었다. 이상의 결과를 종합할 때, 임상에서 니켈-티타늄 합금 와이어에 굴곡을 부여하기 위해 열처리하는 경우 초탄성 특성은 유지될 수 있으나, 부하-변위 곡선의 상방 증가가 나타나므로, 와이어에 의한 교정력이 증가될 수 있음에 유의하여야 한다. $day^{-1}$인 인공습지), scenario 2(면적 4.2ha인 저류지)가 각각 연평균 6.9%, 4.8%, 7.1%의 감소를 보였다. TN은 4.7%, 3.4%, 13.4%의 삭감율을 나타내었으며, TP는 5.6%, 3.9%, 7.3%의 삭감율을 나타내었다. 본 연구에서는

  • PDF