• Title/Summary/Keyword: 변위연성도

Search Result 303, Processing Time 0.026 seconds

Flexural Behavior of Layered RC Slabs, which Bio-Mimics the Interface of Shell Layers, Produced by Using 3D Printable Highly Ductile Cement Composite (3D 프린팅용 고연성 시멘트 복합체를 활용한 패류 껍질층 경계면 모방형 적층 RC 슬래브의 휨 거동)

  • Chang-Jin Hyun;Ki-Seong Kwon;Ji-Seok Seo;Yun-Yong Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.1
    • /
    • pp.90-97
    • /
    • 2024
  • In this study, we employed Highly Ductile Cement Composite (HDCC) to evaluate the flexural performance of a RC slab that simulates the laminating structure of a seashell. To evaluate flexural performance, we produced conventional RC slab specimens, HDCC slab specimens, and HDCC-M slab specimens which biomimics a seashell's layered structure by inserting PE mesh inside the slab made of HDCC. A series of 4-point bending tests were conducted. Experimental results shows the flexural strength of the HDCC-M slab specimen was 1.7 times and 1.2 times higher than that of the RC and HDCC slab specimens, respectively. Furthermore, the ductility was evaluated using the ratio of yield deflection to maximum deflection, and it was confirmed that the HDCC slab test specimen exhibited the best ductility. This is most likely due to the fact that the inserted PE mesh separates the layers and increases ductility, while the HDCC passing through the mesh prevents the loss of load carrying capacity due to layer separation.

The Limiting Drift and Energy Dissipation Ratio for Shear Walls Based on Structural Testing (전단벽의 최소 층변위 및 에너지 소산성능)

  • ;;N.M.Hawins
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.335-343
    • /
    • 1998
  • Recently, new experimental criteria for reinforced concrete frame structures in high seismic regions have been reported in United States. The objective of the criteria is to get more reliable test data which are valid to compare with other test data done by different researchers. The criteria precribe test method of specimens, analysis method of test data, and limiting values needed to specimens like drift angle, energey dissipation ratio, stiffness, and strength. These criteria might be usefel to get objective conclusion. Shear wall structures, which belong to one of earthquake resisting systems, also need this kind of criteria. But, the general response of shear wall structures is a little bit different from that of frame structures since shear wall restrains the horizontal displacement caused by horizontal force and increases the stiffness and strength. The objective of this paper is to propose a criterion for limiting drift and energy dissipation ratio of shear walls based on structural testing. These are the most important values for presenting the capacity of shear walls. Limiting drift and energy dissipation ratios were examined for tests on shear walls having ductile type failures. Test data were analyzed and compared to the results for a suggested acceptance criteria that involve a limiting drift that is a function of aspect ratio and a limiting energy dissipation ratio that is a function of displacement ductility and damping.

Assessment of Ductility and Plastic Hinge Region of Reinforced Concrete Multi-Column Bent (2주형 다주교각의 연성도 및 소성힌지 영역에 관한 연구)

  • Byun, Soon-Joo;Im, Jung-Soon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.3 s.22
    • /
    • pp.37-45
    • /
    • 2006
  • In this study, displacement ductility capacity and plastic hinge regions of reinforced concrete multi-column bent with different transverse reinforcement ratio are investigated. The ductility increases remarkably as transverse reinforcement ratio increase and the multi-column bent loaded along transverse direction is more ductile. The plastic hinge length for special detailing requirements of transverse reinforcement is estimated. For high target ductility, plastic hinge length for confinement should be extended with increased transverse reinforcement ratio. The plastic hinge length of multi-column bent loaded along transverse direction is shorter than that along longitudinal direction, because of the different moment distribution.

Seismic Performance of Octagonal Flared RC Columns using Oblong Hoops (장방형 띠철근을 이용한 팔각형 플레어 RC 기둥의 내진성능)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.1-9
    • /
    • 2015
  • Transverse steel bars are used in the plastic hinge zone of columns to insure adequate confinement, prevention of longitudinal bar buckling and ductile behavior. Fabrication and placement of rectangular hoops and cross-ties in columns are difficult to construct. Details of reinforcement for rectangular section require a lot of rectangular hoops and cross-ties. In this paper, to solve these problems, the new lateral confinement method using oblong hoop is proposed for the transverse confinement of the flared column. It can be the alternative for oblong cross-section and flared column with improved workability and cost-efficiency. The final objectives of this study are to suggest appropriate oblong hoop details and to provide quantitative reference data and tendency for seismic performance or damage assessment based on the drift levels such as residual deformation, elastic strain energy. This paper describes factors of seismic performance such as ultimate displacement/drift ratio, displacement ductility, response modification factor, equivalent viscous damping ratio and effective stiffness.

Prediction of Inelastic Force-Displacement Relationships of Reinforced Concrete Shear Wall Systems Based on Prescribed Ductilities (강성저하 실험식 및 연성계수를 이용한 철근콘크리트 전단벽 구조시스템의 비탄성 하중-변위 관계식 예측)

  • 홍원기
    • Computational Structural Engineering
    • /
    • v.8 no.4
    • /
    • pp.159-171
    • /
    • 1995
  • The parameters describing a complete hysteresis loop include pinch force, drift offset, effective stiffness, unloading and reloading trangential stiffness. Analytical equations proposed to quantify the nonlinear, inelastic behavior of reinforced shear walls can be used to predict these parameters as a function of axial load and drift ratio. For example, drift offset, effective stiffness, and first and second unloading and reloading tangential stiffness are calculated using equations obtained from test data for a desired drift ratio or ductility level. Pinch force can also be estimated for a given drift ratio and axial load. The effective virgin stiffness at the first yield and its post yield reduction can be estimated. The load deflection response of flexural reinforced concrete shear walls can now be estimated based on the effective wall stiffness that is a function of axial force and drift ratio.

  • PDF

An Experimental Study of Creep Crack Initiation Behavior in 304 and 316 Stainless Steels (304스케인리스강과 316스테인리스강의 크립 균열 발생 거동에 관한 실험적 연구)

  • 최영환;엄윤용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.6
    • /
    • pp.1193-1202
    • /
    • 1989
  • 본 논문에서는 발전소의 소재로 많이 쓰이고 있는 304 스테인리스강(앞으로는 304SS로 표기함)과 316스테인리스강(앞으로는 316SS로 표기함)의 크립 균열 발생 거동 을 각각 600.deg. C와 625.deg. C에서 조사한다. 이 온도는 발전소의 반응기(reactor)에 사용 되는 304SS와 316SS이 받는 온도이다. 즉 304SS와 316SS의 크립 균열 발생을 지배 하는 파괴 매개변수가 무엇인지가 크립 파괴 실험을 통하여 조사된다. 실험 결과는 이미 제안되어 있는 크립 균열 발생 모델에서 예측된 결과와 비교된다. 특히 304SS 와 316SS은 고온에서의 연성도가 변형률 속도에 따라 변하는 것으로 알려져 있다. 본 연구에서는 '변형률 속도에 따른 재료의 연성도의 변화에 근거한 균열 발생 모델' 을 제안하고, 그 모델에서 예측된 크립 발생 거동을 실험 결과와 비교한다.

Seismic performance of Piers in Seohae Grand Bridge (서해대교 PSM교 교각의 내진성능)

  • 이재훈;손혁수;배성용;박찬민
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.3
    • /
    • pp.67-81
    • /
    • 2000
  • 서해대교는 국내에 교량구조물에 관한 내진설계가 도입되기 전 설계된 교량으로서 현재 내진설계 규준에 적합하지 않은 종방향철근 및 횡방향 철근이 겹침이음된 중공육각형 단면의 철근콘크리트 기둥으로 이미 시공이 완료된 상태이다. 최근, 지진에 대한 사회적 관심이 대두됨으로서 내진 설계 규준에 적합하지 않은 철근상세를 가지 서해대교 PSM교 교각의 내진성능이 의문시되었다. 따라서, 비내진 철근상세를 가진 서해대교 PSM교 교각의내진성능 평가를 위하여 교각의 축소모형 실험을 수행하였으며, 실험결과 종방향철근 겹침이음이 교각의 전체적인 내진거동에는 큰 영향을 미치지 않으며 기대 이상의 연성을 발휘할 수 있는 것으로 나타났다. 본 논문에서는 축소모형 실험결과에 의한 시험체의 파괴양상, 유효강성, 연성, 응답수 정계수 및 등가점성감쇠비를 분석하였으며, 아울러 가속도변위 응답스펙트럼을 이용하여 서해대교 PSM교 교각의 내진성능을 평가하였다.

  • PDF

Response scaling factors for nonlinear response analysis of MDOF system (다층건물의 비선형 반응해석을 위한 반응수정계수)

  • 한상환;이리형
    • Computational Structural Engineering
    • /
    • v.8 no.3
    • /
    • pp.103-111
    • /
    • 1995
  • Evaluating nonlinear response of a MDOF system under dynamic stochastic loads such as seismic excitation usually requires excessive computational efforts. To alleviate this computational difficulty, an approximation is developed in which the MDOF inelastic system is replaced by a simple nonlinear equivalent system(ENS).Me ENS retains the most important properties of the original system such as dynamic characteristics of the first two modes and the global yielding behavior of the MDOF system. The system response is described by the maximum global(building) and local(interstory) drifts. The equivalency is achieved by two response scaling factors, a global response scaling factor R/sub G/, and a local response scaling factor R/sub L/, applied to the responses of the ENS to match those of the original MDOF system. These response scaling factors are obtained as functions of ductility and mass participation factors of the first two modes of structures by extensive regression analyses based on results of responses of the MDOF system and the ENS to actual ground accelerations recorded in past earthquakes. To develop the ENS with two response scaling factors, Special Moment Resisting Steel Frames are considered. Then, these response scaling factors are applied to the response of ENS to obtain the nonlinear response of MDOF system.

  • PDF

Coupled Load Analysis Using MSC/Nastran Superelement (MSC/Nastran Superelement를 이용한 연성하중해석)

  • Kim, Gyeong-Won;Kim, Jin-Hui;Lee, Ju-Hun;Kim, Seon-Won
    • Aerospace Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.60-66
    • /
    • 2006
  • This paper is a study on the coupled load analysis using MSC/Nastran superelement method. After selecting the hunch vehicle, coupled load analysis is performed. From the results of coupled load analysis the loads and displacements on the major parts of satellite structure are calculated Based on the loads and displacements, the safety of satellite structure is judged. Coupled load analysis has been executed using MSC/Nastran DMAP code so far. Because DMAP code was very complicated and long in 1ength it was difficult to analyze and modify the DMAP code. To solve out these problems, coupled load analysis was executed using MSC/Nastran 2005 superelemnt method. At first, satellite FE-model was converted to the Craig-Bampton model using MSC/Nastran 2005 superelement method and verified Finally, coupled load analysis was performed using satellite Craig-Bampton model and launch vehicle FE-model and verified.

  • PDF

Evaluation of Ductility and Strength Factors for Special Steel Moment Resisting Frames (철골 연성 모멘트 골조의 연성계수 및 강도계수 평가)

  • Kang, Cheol Kyu;Choi, Byong Jeong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.6 s.73
    • /
    • pp.793-805
    • /
    • 2004
  • The main objective of this paper is to evaluate the ductility and strength factors that are key components of the response modification factor for special steel moment-resistant frames. The ductility factors for special steel moment-resistant frames were calculated by multiplying the ductility factor for SDOF systems and the MDOF modification factors. Ductility factors were computed for elastic and perfectly plastic SDOF systems undergoing different levels of inelastic deformation and periods when subjected to a large number of recorded earthquake ground motions. Based on the results of the regression analysis, simplified expressions were proposed to compute the ductility factors. Based on previous studies, the MDOF modification factors were also proposed to account for the MDOF systems. Strength factors for special steel moment resisting frames were estimated from the results of the nonlinear static analysis. A total of 36 sample steel frames were designed to investigate the ductility and strength factors considering design parameters such as number of stories (4, 8, and 16 stories), seismic zone factors (Z = 0.075, 0.2, and 0.4), framing system (Perimeter Frames, PF and Distributed Frames, DF), and failure mechanism (Strong-Column Weak Beam, SCWB, and Weak-Column Strong-Beam, WCSB). The effects of these design parameters on the ductility and strength factors for special steel moment-resisting frames were investigated.