• Title/Summary/Keyword: 변위능력

Search Result 276, Processing Time 0.022 seconds

Capacity Spectrum Method Based on Inelastic Displacement Ratio (비탄성변위비를 이용한 능력 스펙트럼법)

  • Han, Sang-Whan;Bae, Mun-Su
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.69-80
    • /
    • 2008
  • In this study, improved capacity spectrum method (CSM) is proposed. The method can account for higher mode contribution to the seismic response of MDOF systems. The CSM has been conveniently used for determining maximum roof displacement using both demand spectrum and capacity curve of equivalent SDOF system. Unlike the conventional CSM, the maximum roof displacement is determined without iteration using inelastic displacement ratio and R factor calculated from demand spectrum and capacity curve. Three moment resisting steel frames of 3-, 9- and 20-stories are considered to test the accuracy of the proposed method. Nonlinear response history analysis (NL-RHA) for three frames is also conducted, which is considered as an exact solution. SAC LA 10/50 and 2/50 sets of ground motions are used. Moreover, this study estimates maximum story drift ratios (IDR) using ATC-40 CSM and N2-method and compared with those from the proposed method and NL-RHA. It shows that the proposed CSM estimates the maximum IDR accurately better than the previous methods.

The effect of unstable plate on the ankle joint displacement and dynamic balance ability of female college students wearing high-heeled shoes (불안정 판을 이용한 훈련이 높은 굽 신발을 신은 여자 대학생의 발목관절 변위와 동적균형능력에 미치는 영향)

  • Nam, Taek-Gill;Lee, Ji-Hyun
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.5
    • /
    • pp.31-38
    • /
    • 2017
  • The purpose of this study was to investigate the effect of training using unstable plate on displacement and dynamic balance ability of ankle joints in women college students wearing high heel shoes. Subjects were randomly divided into experimental group and control group. 3D motion analysis was performed while walking 9cm high-heeled shoes and walking 5m. Dynamic balanced ability evaluation was performed. The intervention program was administered to experimental subjects three times a week for four weeks. They performed balance training using unstable plates. There was no intervention in the control group. The results showed that the displacement of the ankle joints in the experimental group after the intervention was decreased overall and the dynamic balance ability was significantly increased. The control group showed little change. As a result, the training using unstable plate stabilizes the ankle joints and improves the dynamic balance ability of the subjects wearing high-heeled shoes.

A test on deformation detection ability of GPS (GPS의 변위 검출 능력에 대한 실험)

  • 박필호;박종욱;조정호;전경수;조성호
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.17 no.2
    • /
    • pp.161-166
    • /
    • 1999
  • The GPS ability for detecting the deformation is experimently tested by analyzing how precisely GPS can detect the true movement value of the GPS test bed with three axis. As the result, we found that GPS can detect the deformation with the precision of 2 mm in horizontal componts and 8 mm in vertical component for the short baseline of 16 km. The applicable possibilities of GPS for measuring the structure deformation are discussed on the base of this result.

  • PDF

Dependency Evaluation According to Damper Strut Type (댐퍼 스트럿 형상에 따른 의존성 평가)

  • Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.78-86
    • /
    • 2014
  • The purpose of this study is the displacement and velocity dependence evaluation of I type and S type metallic dampers. For this purpose, 12 metallic damper specimens are prepared and dependence test are performed. Test variables are strut type, displacement and velocity dependence. From the evaluation results of dependence tests, number of cycles are fully exceeded than minimum 5 cycles described in ASCE 7-10. According to displacement dependence test results, larger target displacement (50mm) shows lower cyclic numbers and cumulated energy dissipated area than lower target displacement (25mm). Also it show higher strength and early failure than short target displacement. In velocity dependence evaluation, fast target velocity (60mm/sec) shows lower cyclic numbers and cumulated energy dissipated area than target velocity (40mm/sec). As a results of basic properties, dependence evaluation and cumulated energy dissipated area evaluation, dependence capacity of S type metallic damper is far superior than I type.

Displacement and Velocity Dependence of Clamped Shape Metallic Dampers (꺽쇠형 강재 댐퍼의 변위 및 속도 의존성)

  • Lee, Hyun Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.62-70
    • /
    • 2013
  • The purpose of this study is the displacement and velocity dependence evaluation of clamped shape metallic damper, which were evaluated superior in energy dissipation capacity than straight type slit damper. For this purpose, 6 metallic damper specimens are prepared and dependence test are performed. Test variables are displacement dependence and velocity dependence. According to displacement dependence test results, larger target displacement (50mm) shows lower cyclic numbers and cumulated energy dissipated area than lower target displacement (25mm). Also it shows higher strength and early failure than short target displacement. In velocity dependence evaluation, fast target velocity (60mm/sec) shows lower cyclic numbers and cumulated energy dissipated area than slow target velocity (40mm/sec). Therefore the hysteresis dependence of metallic damper were evaluated as close relation to the loading displacement and velocity conditions.

Three Dimensional Motion of the Center of Mass While Crossing an Obstacle in Young and Older Adults (젊은 성인과 노인의 장애물 보행 시 신체질량중심의 3차원적 움직임)

  • Son, nam-kuk;Kim, hyeong-dong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2013.05a
    • /
    • pp.381-382
    • /
    • 2013
  • 본 연구의 목적은 젊은 성인과 노인의 장애물 보행 시 신체질량중심의 변위와 최대속도를 3차원적으로 비교 분석하여 노인의 낙상위험 및 균형능력을 평가할 수 있는 중요한 요소가 될 수 있는지를 검증하는데 있다. 본 연구의 대상은 건강한 젊은 성인 10명(남성 6명/여성 4명, $24.6{\pm}1.9$세)과 65세 이상 건강한 노인 10명(남성 1명/여성 9명)으로 선정하였다. 각 피험자 신장의 10% 높이의 장애물 보행을 실시하였으며 동작 분석 장비를 통해 신체질량중심의 변위와 최대속도를 3차원적으로 분석하였다. 전후방향에서는 젊은 성인 집단의 변위가 더 크고(p=.019) 최대속도가 더 빠르게 나타났으며(p<.001), 좌우방향에서는 노인 집단의 변위가 더 크고(p=.004), 더 빠르게 나타났다(p<.001). 수직방향에서의 변위는 유의한 차이가 없었고(p=.135), 최대 속도는 젊은 성인 집단이 더 빠르게 나타났다(p<.001). 신체질량중심의 좌우방향에서의 크고 빠른 움직임은 노인의 동적 균형능력 저하로 인해 넘어가는 발(swing limb)의 안정적인 지지면 딛기를 위한 보상적 조절로 여겨지며, 따라서 노인의 낙상위험 및 균형능력을 평가할 수 있는 중요한 요소가 될 수 있을 것으로 사료된다.

  • PDF

Evaluation of Ductility Capacity of Reinforced Concrete Bridge Columns Subject to Cyclic Loading Using Flexibility-Based Fiber Element Method (유연도법 섬유요소모델에 의한 반복하중을 받는 철근콘크리트 교각의 연성능력 평가)

  • 고현무;조근희;조호현
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.3
    • /
    • pp.11-21
    • /
    • 2002
  • The evaluation of displacement ductility is performed by direct method through tracking the inelastic hysteretic behavior of RC bridge columns subject to cyclic loading using a flexibility-based fiber element mode. To reasonably track the inelastic behavior until the RC bridge column reaches its ultimate state, the average stress-average strain relations and joint elements, which agree well with experiments, are modified and applied considering the tension stiffening behavior and discontinuous displacement between the column and its base. In addition the evaluation of displacement ductility is performed by a direct method easily applicable to numerical analysis. Locations for the integration points, values for the post-crushing concrete strength and low-cycle fatigue failure of longitudinal reinforcement that affect the calculation of yielding and ultimate displacements are proposed for the application to flexibility-based fiber element model. Since less than 10% of error occurs during the displacement ductility analysis, the yielding and ultimate displacements evaluated by the applied analysis method and model appear to be valid.

Evaluation of Proper Supplemental Damping for a Multi-Story Steel Frame Using Capacity Spectrum Method (능력스펙트럼법을 이용한 다증 철골조 건물의 적정 감쇠기 선정)

  • 김진구;최현훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.103-111
    • /
    • 2001
  • 본 연구에서는 능력스펙트럼법을 이용하여 성능목표를 만족하기 위하여 필요한 점성 감쇠기? 양을 간단하고 직접적인 방법으로 산정하는 방법에 관하여 연구하였다. 먼저 능력스펙트럼법을 이용하여 구조물의 비탄성 응답을 구하고 구조물의응답과 목표변위의 차이를 이용하여 필요한 유효감쇠비를 구하였다. 그리고 이러한 유효감쇠비를 이용하여 필요한 점성감쇠기의 양을 선정하였다. 본 연구에서 제안한 방법의 타당성을 검증하기 위해 10층의 철골조 건물에 세 가지 유형의 층지진하중을 가하고 제안된 절차에 따라 필요한 감쇠기의 양을 구하였다. 해석결과에 따르면 제안된 방법에 의하여 설계된 점성 감쇠기를 해석 모델에 설치하고 시간이력 해석을 수행한 결과 최대응답은 목표변위와 잘 일치함을 발견하였다.

  • PDF

Calculation of Optimum Damping Ratio of Viscous Dampers Using Capacity Spectrum Method (능력스펙트럼법을 이용한 점성 감쇠기의 적정 감쇠비 산정)

  • 김진구;최현훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • 에너지 소산장치가 설치된 건무의 비선형 시간이력해석은 복잡하고 많은 시간이 소모된다. 본 연구에서는 비선형 정적해석법인 능력 스펙트럼을 이용하여 구조물의 주어긴 거동 한계를 만족할 수 있는 감쇠기의 양을 산정하는 방법에 관하여 연구하였다. 먼저 능력스펙트럼법을 이용하여 건물의 비선형 정적응답을 구하고 건물의 응답과 목표변위의 차이를 이용하여 유효감쇠비를 구하고 이러한 유효 감쇠비를 이용하여 필용한 점성 감쇠기의 양을 구하였다. 본 연구에서는 단자 유도계에서 건물의 주기, 요구되는 탄성강도에 대한 항복강도의 비, 항복 후 강성비 등을 변수로 하여 연구를 수행하였다. 제안된 방법에 따라 설계된 점성 감쇠기를 설치한 예제 구조물의 시간이력 해석에 의한 최대 응답은 설계의 초기단계에서 사용한 목표변위와 잘 일치하였다.

  • PDF

Experiments of the Lateral Loading Capacity of Exterior Joints of Non-seismically Designed RC Frames in Korea (비내진설계된 우리나라 RC 외부 접합부의 횡저항 능력에 관한 실험)

  • Lee, Young-Wook;Park, Hyeong-Kyeon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.29-36
    • /
    • 2010
  • To investigate the cyclic characteristics of exterior joints in RC frame buildings which are typically used after 1988, 70% scaled T-shaped beam-column subassemblies were designed and tested with a displacement control that is composed of 9 steps, until 3.5% story drift was reached. Axial forces are applied to columns during the experiment to simulate a real situation. The results show that the non-seismic detailed specimens failed before reaching 0.85% story drift, and their strengths are less than 0.85 times the nominal flexural strength which beam or columns should reach. The relationship of principal stress and story drift of exterior joints is similar to the one that Priestly proposed.