Abstract
The purpose of this study is the displacement and velocity dependence evaluation of I type and S type metallic dampers. For this purpose, 12 metallic damper specimens are prepared and dependence test are performed. Test variables are strut type, displacement and velocity dependence. From the evaluation results of dependence tests, number of cycles are fully exceeded than minimum 5 cycles described in ASCE 7-10. According to displacement dependence test results, larger target displacement (50mm) shows lower cyclic numbers and cumulated energy dissipated area than lower target displacement (25mm). Also it show higher strength and early failure than short target displacement. In velocity dependence evaluation, fast target velocity (60mm/sec) shows lower cyclic numbers and cumulated energy dissipated area than target velocity (40mm/sec). As a results of basic properties, dependence evaluation and cumulated energy dissipated area evaluation, dependence capacity of S type metallic damper is far superior than I type.
Keywords
Damper; Strut type; Displacement; Velocity; Dependency;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Lee, H. H., and Kim, S. I. (2010), Metallic Damper Shape and Cyclic Behavior for the Seismic Capacity Improvement of Building Structures, Journal of the Korea Institute for Structural Maintenance Inspection, 14(3), 123-130 (in Korean).   과학기술학회마을
2 Lee, H. H., and Kim, S. I. (2011), Evaluation on Hysteretic Behaviors of V shaped metallic dampers, Journal of the Korea Institute for Structural Maintenance Inspection, 15(1), 254-262 (in Korean).   과학기술학회마을   DOI
3 Soong, T. T., and Dargush, G. F. (1997), Passive Energy Dissipation Systems in Structural Engineering, John Wiley & Sons, 35-81.
4 ASCE (2010), Minimum Design Loads for Buildings and Other Structures (ASCE 7-10), ASCE. 179-197.
5 Japan Society of Seismic Isolation (2005), Design and Construction Manual of Passive Seismic Control Structures, Japan Society of Seismic Isolation (in Japanese).
6 Lee, H. H. (2013), Displacement and Velocity Dependence of Clamped Shape Metallic Dampers, Journal of the Korea Institute for Structural Maintenance Inspection, 17(2), 62-70 (in Korean).   과학기술학회마을   DOI