• Title/Summary/Keyword: 베타-선

Search Result 120, Processing Time 0.021 seconds

Characteristic Evaluation of Exposed Dose with NORM added Consumer Product based on ICRP Reference Phantom (ICRP 기준팬텀 기반의 천연방사성핵종이 포함된 가공제품 사용으로 인한 피폭선량 특성 평가)

  • Yoo, Do Hyeon;Lee, Hyun Cheol;Shin, Wook-Geun;Choi, Hyun Joon;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.159-167
    • /
    • 2014
  • In Korea, July 2012, the law as called 'Act on Safety Control of Radioactive Rays Around Living Environment' was implemented to control the consumer product containing Naturally Occurring Radioactive Material (NORM), but, there are no appropriate database and effective dose calculation system. The aim of this study was to develop evaluation technique of the exposure dose with the use of the consumer products containing NORM and to understand the characteristics of the exposed dose according to the radiation type and energy. For the evaluate of exposure dose, the ICRP reference phantom was simulated by the MCNPX code based on Monte Carlo method, and the minimum, medium, maximum energy of alphas, betas, gammas from the representative NORM of Uranium decay series were used as the source term in the simulation. The annual effective doses were calculated by the exposure scenario of the consumer product usage time and position. Short range of the alpha and beta rays are mostly delivered the dose to the skin. On the other hand, the gamma rays mostly delivered the similar dose to all of the organs. The results of the annual effective dose with $1Bq{\cdot}g^{-1}$ radioactive stone-bed and 10% radioactive concentration were employed with the usage time of 7 hours 50 minute per day, the maximum annual effective dose of alphas, betas, gammas were calculated 0.0222, 0.0836, $0.0101mSv{\cdot}y^{-1}$, respectively.

Fabrication and estimation of the plastic detector for measuring the contamination for beta-ray level of the kind of duct waste (배관류 폐기물의 베타선 오염도 측정용 플라스틱 검출기 제작 및 특성평가)

  • Kim Gye-Hong;Oh Won-Zin;Lee Kune-Woo;Seo Bum-Kyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.3
    • /
    • pp.159-165
    • /
    • 2005
  • The characterization of radiological contamination inside pipes generated during the decommission of a nuclear facility is necessary before pipes can be recycled or disposed. But, existing direct measurements of radioactive contamination level using the survey-meter can not estimate the characteristic of contamination on a local area such as the pipe inside. Moreover, the measurement of surface contamination level using the indirect methods has many problems of an application because of the difficulty of collecting sample and contamination possibility of a worker when collecting sample. In this work, plastic scintillator was simulated by using Monte Carlo simulation method for detection of beta radiation emitted from internal surfaces of small diameter pipe. Simulation results predicted the optimum thickness and geometry of plastic scintillator at which energy absorption for beta radiation was maximized. In addition, the problem of scintillator processing and transferring the detector into the pipe inside was considered when fabricating the plastic detector on the basis of simulation results. The characteristic of detector fabricated was also estimated. As a result, it was confirmed that detector capability was suitable for the measurement of contamination level. Also, the development of a detector for estimating the radiological characteristic of contamination on a local area such as the pipe inside was proven to be feasible.

  • PDF

Research of Efficiency for Gas Electron Multiplier Detector to Monitor Low Energy Gamma-Ray and Beta-Ray (낮은 에너지 감마선과 베타선 모니터링을 위한 Gas Electron Multiplier 검출기의 효율성에 대한 연구)

  • Lee, Soonhyouk;Jung, Jae Hoon;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.95-99
    • /
    • 2014
  • Radiation monitoring is one of the most important process in all places where radioactive material is used including hospital. In this preliminary study, we made GAS electron multiplier (GEM) detector and acquired relative efficiencies in order to see if GEM detector can be useful in radiation monitoring system. The relative efficiency was acquired by using the ratio of GEM detector efficiency to CdTe detector efficiency. The relative efficiency of 72% and 4% was acquired for beta-ray and gamma-ray respectively.

Investigation on the techniques of quality control for radiation counting systems (방사선 측정기의 품질관리 기법에 대한 고찰)

  • Song, Byoung-Chul;Kim, Young-Bok;Han, Sun-Ho;Oh, Se-Jin;Lee, Myung-Ho;Song, Kyu-Seok
    • Analytical Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.414-420
    • /
    • 2011
  • In this study, radiation measurement system has been investigated to set up for the radioisotopes analysis in the radioactive waste samples after selecting the radiation counters of alpha beta and gamma nuclides. The counting efficiencies for alpha, beta and gamma measurement systems were calibrated. To obtain stability of the radiation detectors, quality control program has been established. Also, minimum detectable activities (MDAs) depending on the type of samples were calculated for increasing the confidence level for analytical result.

The Analysis and Comparison of the Experiments for Electro-Decontamination about Radioactive Metal Wastes (방사성 금속 폐기물의 전해제염 실험 비교 분석)

  • 강동우;박광수;문길호;엄달선
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.196-201
    • /
    • 2003
  • Decontamination means every method that can drop the level of the radioactivities from the materials contaminated with them to the allowable one. In this paper, one of the decontamination methods, the electro-decontamination was described with lots of experiments. Two test specimens contaminated with alpha ray and beta ray respectively were used to compare the decontamination factors between two rays and many experiments were performed in every electrolyte with SUS and Carbon steel test specimens. Sulphuric acid, phosphoric acid, nitric acid, citric acid and oxalic acid were used as the electrolyte. Decontamination Factors (DF) could be compared and analyzed with different electrolyte, current intensities and time.

  • PDF

Development of Apparatus and Methods for Understanding the Dynamics of the Western Boundary Current (서안경계류 역학을 이해하기 위한 실험 장치 및 방법 개발)

  • Jang, Swung-Hwan;Shin, Jung-Sun;Moon, Byung-Kwon
    • Journal of the Korean earth science society
    • /
    • v.31 no.1
    • /
    • pp.88-94
    • /
    • 2010
  • A simple laboratory device and methodology are developed for deep understanding of the western boundary current (WBC). The apparatus consists of a rotating (count-clockwise) rectangular tank with a sloping bottom in order to simulate the beta effect, the variation of the Coriolis parameter with latitude. We also used a clockwise rotating disk at the surface water to mimic the wind stress forcing in mid-latitude oceans. Four experiments were carried out using some combination of a bottom type and a rotation of the tank. Experiment with the beta effect clearly demonstrated the WBClike flow as well as the Sverdrup interior. However, the water in a tank gave rise to an inertial motion under the influence of a constant Coriolis force alone. We also discussed a stiffening of the rotating fluid on the basis of the Taylor-Proudman effect. We believe that the apparatus and methods developed in this study help to understand the WBC due to the beta effect.

Intercomparison of the KAERI Reference Photon and Beta Radiation Measurements (한국원자력연구소 기준 광자 및 베타선장 측정의 국제상호비교)

  • Chang, Si-Yeong;Kim, Bong-Hwan;Kim, Jang-Lyul;McDonald, J.C.;Murphy, M.K.
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.255-262
    • /
    • 1996
  • This paper describes the results of intercomparison measurements of KAERI reference photon and beta radiation fields between the KAERI and the PNNL(Pacific Northwest National Laboratory), recently performed at KAERI radiation calibration and dosimetry laboratory on the basis of the ANSI N13.11 criteria for personal dosimeter performance test. Each laboratory used her own radiation detectors or measurement devices traceable to her national primary standard in measuring the exposure rates for photon fields, the absorbed dose rates for beta radiation fields. The agreements in reference radiation measurements between two laboratories were found to be less than ${\pm}2.0%$ for photon fields, ${\pm}1.0%$ for beta radiation fields. Therefore, it could be concluded that KAERI reference radiation fields comply well with the international standard and thus can further serve as a national basis for the researches and developments in radiation protection dosimetry in Korea.

  • PDF

서안경계류 발생역학을 이해하기 위한 실험 장치 및 방법 개발

  • Jang, Seung-Hwan;Sin, Jeong-Seon;Mun, Byeong-Gwon
    • 한국지구과학회:학술대회논문집
    • /
    • 2010.04a
    • /
    • pp.48-50
    • /
    • 2010
  • Stommel(1948)은 서안경계류의 원인이 베타효과($\beta$-effect)라 일컫는 코리올리 파라미터(f)의 위도 변화 때문인 것을 밝혔다. 서안경계류는 고등학교나 대학 교양에서 중요하게 다뤄지고 있다. 학생들은 보통 이론 수업만으로 서안경계류의 발생 과정, 이에 관련된 코리올리 힘, 베타효과 등을 이해해야 한다. 때문에 서안경계류와 관련된 실험이 있다면 이를 이해하는 데 큰 도움이 될 것이다. 또한 연구에서 검토한 6종의 고등학교 지구과학 2 교과서는 서안경계류를 본문과 더불어 삽화로 설명하고 있다. 그러나 이 중 3종의 교과서 삽화에서는 서안경계류의 발생 원인을 코리올리 힘만으로 지적하고 있다. 따라서 일부 학생은 서안경계류의 원인을 코리올리 힘으로 오해 할 수 있다. 위와 같은 이유로 우리는 서안경계류가 코리올리 힘의 작용과 베타효과에 의해 나타나는 것을 쉽게 확인 할 수 있는 실험 장치와 다양한 실험 방법을 개발하였다. 개발한 실험 장치는 직육면체의 수조와 회전 속도를 조절할 수 있는 테이블로 구성된다. (Fig. 1) 이와 같은 회전수조는 대기와 해양의 움직임을 실험실에서 모사하기 위해 자주 사용되었다(Beardsely 1969, 소선섭 등 1995; 1997). 우리의 수조는 경사진 바닥과 평평한 바닥으로 두종류를 제작하였다. 바닥이 경사진 수조는 베타효과를 구현하기 위한 것이다. 반시계 방향으로 회전하는 테이블은 중위도 어떤 위도에 접하는 가상의 평면이 지구 자전에 의해 회전하는 것을 나타낸다. 그리고 수조 상부에는 회전원판을 물에 접하여 시계방향으로 회전시킨다. 회전원판은 북반구 중위도 해양에 작용하는 바람 응력을 나타낸다. 우리는 테이블의 회전유무와 바닥의 경사유무에 따라 4개 실험을 수행하였다(Table. 1). 각 실험에서 물을 채운 수조를 원판에 올려놓고, 회전원판을 작동시킨 후 20분 동안 그대로 두어 수조안의 미세규모의 운동을 최소화 시킨 후 잉크를 떨어뜨리고 관찰하였다. 그 결과 실험 SB_f1은 베타효과와 코리올리 힘이 존재하여 서쪽 경계에서 좁고 빠른 흐름을 만들고 수조의 중간 부근에서 경계를 벗어나 동쪽으로 향하고 있다. 이 모습은 실제 해양의 서안경계류의 분리 현상과 비슷하다. FB_f1은 코리올리 힘만 존재하여 서쪽 경계에서 좁고 빠른 순환과 경계를 벗어나 동쪽으로 분리되는 흐름이 나타나지 않으며 전반적으로 크게 회전하는 모습을 보인다. SB_f0은 바람의 응력만 존재하는 경우로 잉크가 확산하는 모습을 보이며 나선팔의 모양으로 회전하면서 넓게 퍼져나간다. FB_f0의 모양도 이와 비슷하게 나타난다. 실험 SB_f1과 FB_f1을 비교하여 서안경계류는 코리올리 힘의 위도변화 효과인 베타효과가 있을 때 발생한다는 것을 알 수 있다(Fig. 2). 이 결과는 "단순히 코리올리 효과에 의해 서안경계류가 발생한다"는 생각을 바꾸게 할 것이다. 덧붙여 서안경계류 분리와 수조 바닥의 경사의 관계를 살펴보기 위한 실험을 실시하였다. 경사가 더 급하면 ($\alpha=20^{\circ}$) 서쪽 경계를 벗어나는 지점이 좀 더 북쪽에 나타났다. 현재 서안경계류는 개발한 실험 장치와 방법을 학교 현장에 적용하여 그 교육적 활용 가치를 평가하는 연구를 진행하고 있다.

  • PDF