• Title/Summary/Keyword: 법랑질 표면

Search Result 186, Processing Time 0.046 seconds

Effect of remineralization and inhibition to demineralization after fluoride gel or hydroxyapatite paste application on stripped enamel (치간 삭제 후 불소 또는 수산화인회석 도포 시 재광화 및 탈회억제에 관한 연구)

  • Hong, Hyun-Sil;Kim, Ho-Young;Sung, Ji-Young;Cho, Jin-Hyoung;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.40 no.4
    • /
    • pp.212-226
    • /
    • 2010
  • Objective: The aim of this study was to evaluate the effect of remineralization and inhibition to demineralization after fluoride gel (acidulated phosphate fluoride, APF) or hydroxyapatite (HAp) paste application on interdentally stripped teeth. Methods: After interdental stripping, 1.23% APF or 5%, 10% HAp paste were applied for 7 days for remineralization. Afterwards, teeth were exposed to lactate carbopol buffer solution for demineralization. Scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS) were used to compare change in surface contents and crystal structures after remineralization, and then after demineralization. Results: EDS analysis indicated that calcium (p < 0.001) and phosphate (p < 0.01) contents were increased after 10% HAp paste application on stripped enamel, calcium (p < 0.05) and phosphate (p < 0.01) contents were increased after 5% HAp paste application, and fluoride (p < 0.01) contents were increased after 1.23% APF application. SEM image showed that enamel surfaces became smoother and crystal structures became small and compact after APF or HAp application. After demineralization, calcium (p < 0.05) and phosphate (p < 0.05) contents remained increased on the enamel remineralized with 10% HAp paste, and phosphate (p < 0.05) contents remained increased on the enamel remineralized with 5% HAp paste. After demineralization, surfaces looked less destroyed in the enamel remineralized beforehand than those of the control, and small pores between crystal structures, formed by remineralization were remained. Conclusions: Hydroxyapatite paste and fluoride gel were helpful to remineralize and inhibit deminerlization on stripped enamel.

SEM EVALUATION AND SHEAR BOND STRENGTH OF ER : YAG LASER IRRADIATION ON ENAMEL SURFACE (Er : YAG 레이저 조사가 법랑질 표면 변화와 전단강도에 미치는 영향)

  • Lim, Hyoung-Soo;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.374-382
    • /
    • 2001
  • The purpose of this study was to investigate the surface morphology and measure shear bond strength of Er : YAG lased enamel. To determine the most effective energy density of laser for improving bonding strength of human enamel, 24 specimen were lased from 30mJ to 150mJ at 1Hz used focused, defocused beam. After irradiation, the lased specimen were observed scanning electron microscope. To determine the resin shear bond strength of Er : YAG lased enamel, the 90 specimen were divided into 3 groups. The Control group was etched with 37% phosphoric acid for 15seconds and rinsed. Group 1 was only laser irradiaton(60mJ, 10Hz), Group 2 was irradiated as Group 1 regimen, followed 37% phosphoric acid etching. The following results were obtained: 1. In both focused and defocused Er : YAG lased enamel surface are similar to acid-etched enamel more than 60mJ in SEM evaluation. 2. The more increased laser energy, the more observed fissuring surface. 3. The highest mean shear bond strength value was observed in control group with the statistical significance(p<0.05) between all the other groups and the shear bond strength in group 1 was the lowest with significant difference among the other groups.

  • PDF

THE EFFECTS OF SURFACE TREATMENTS ON SHEAR BOND STRENGTHS OF LIGHT-CURED AND CHEMICALLY CURED GLASS IONOMER CEMENTS TO ENAMEL (법랑질의 표면처리가 광중합형 및 화학중합형 글래스아이오노머 시멘트의 전단결합강도에 미치는 영향)

  • Shin, Kang-Seob;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.25 no.2 s.49
    • /
    • pp.223-233
    • /
    • 1995
  • The purpose of this study was to evaluate the effects of surface conditioning with $10\%$ polyacrylic acid, etching with $38\%$ phosphoric acid, and polishing with a slurry of pumice on shear bond strengths of light-cured glass ionomer cement, chemically cured glass ionomer cement, and a composite resin to enamel, and to observe the failure patterns of bracket bondings. Shear bond strengths of glass ionomer cements were compared with that of a composite resin. Metal brackets were bonded on the extracted human bicuspids after enamel surface treatments, and samples were immersed in the $37^{\circ}C$ distilled water bath, and shear bond strengths of glass ionomer cements and a composite resin were measured on the Instron machine after 24hrs passed, and the deboned samples were measured in respect of adhesive remnant index. Scanning electron micrographs were taken of enamel surfaces after various treatments. The data were evaluated and tested by ANOVA and Duncan's multiple range test, and those results were as follows. 1. Shear bond strength of light-cured glass ionomer cement showed statistically higher than that of chemically cured glass ionomer cement. 2. Shear bond strengths of light-cured and chemically cured glass ionomer cements to enamel treated with $10\%$ polyacrylic acid and $38\%$ phosphoric acid showed statistically higher than those with a slurry of pumice. 3. According to scanning electron micrographs, enamel surface conditioned with $10\%$ polyacrylic acid is slightly etched and cleaned, that etched with $38\%$ phosphoric acid is severely etched, and that polished with a slurry of pumice is irregulary scretched and not completely cleaned. 4. After debonding, light-cured glass ionomer cement to enamel treated with $10\%$ polyacrylic acid showed less residual materials on the enamel solace than composite resin to enamel etched with $38\%$ phosphoric acid. 5. There was no significant difference in the shear bond strength of light-cured glass ionomer cement to enamel treated with $10\%$ polyacrylic acid and that of composite resin to enamel etched with $38\%$ Phosphoric acid.

  • PDF

A STUDY ON THE ENAMEL EROSION BY CARBONATED BEVERAGE (탄산음료의 법랑질 침식효과에 대한 연구)

  • Lee, Kyung-Ho;Park, Soo-Jin;Jung, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.144-151
    • /
    • 2005
  • Erosion is believed to be the predominant cause of teeth wear in children and young adults, although there will at ways be a contribution from attrition and abrasion. The pH of cola is known to be low and have, therefore, been implicated in the increasing incidence of erosion. The aim of present study was to evaluate the effect of cola on the progression of erosive demineralization in human enamel using demineralization model in vitro. Six groups of human enamel slap were immersed(5 min each bath) in fresh cola, with immersions taking place with or without agitation, and under 3 regimes of frequency intake(low intake, 1 immersion/day; medium, 5/day; high, 10/day). Quantitative assessments of surface erosion were done over an 8-day interval using surface microhardness testing. 1. The average pH of cola was 2.5, which was acidic enough to cause tooth erosion. 2. All the enamel specimen exposed to cola showed erosion like lesions and surface hardness decreased in proportion to the length of immersion (p<0.05). 3. The surface hardness of enamel decreased in proportion to the frequency of immersion (p<0.05). 4. Increased degassing from the drink by gitation accelerated the enamel softening compared with those without agitation.

  • PDF

SCANNING ELECTRON MICROSCOPIC STUDY OF THE EFFECT OF ACIDIC DRINK ON ENAMEL EROSION : A CASE REPORT (탄산음료에 의해 부식된 법랑질 표면변화에 대한 증례발표)

  • Kim, Su-Youn;Park, Jae-Hong;Kim, Gwang-Chul;Choi, Young-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.509-515
    • /
    • 2008
  • It is widely believed that the increase in the prevalence of dental erosion is due to soft drinks. The purpose of this study was to assess the influence of soft drinks and etchant on the erosion of tooth enamel and the effect of tooth brushing on the abrasion of eroded enamel, and the effect of milk, saliva and Tooth $Mousse^{(R)}$ on the remineralization. The changes in tooth enamel surface were observed by scanning electron microscophy. The results were as follows; 1. The pH of Coca-Cola and Chilsung-Cider were higher than the pH of FineEtch 37 and $Tyrian^{TM}SPE$. 2. The SEM photos revealed that the pattern of the surface eroded by Coca-Cola and Chilsung-Cider were more obvious than that eroded by etchants. 3. The results of remineralization by saliva, milk, Tooth $Mousse^{(R)}$ were not different from each other. 4. The remineralization by saliva decreased tooth brushing abrasion.

  • PDF

INFLUENCE OF THE ENAMEL TREATMENT WITH ER:YAG LASER ON THE MICROLEAKAGE OF PIT AND FISSURE SEALANT (Er:YAG 레이저를 이용한 법랑질 표면처리가 치면열구전색제의 미세누출에 미치는 영향)

  • Lee, Ji-Hyun;Kim, Jae-Moon;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.192-200
    • /
    • 2006
  • The aim of this study was to assess the microleakage underneath a pit and fissure sealant bonded to occlusal surfaces treated by Er:YAG laser To determine the most effective energy density of laser, fourteen specimens were irradiated from 50mJ to 300mJ at 3Hz. After irradiation, the lased specimens were observed under the scanning electron microscope. Thirty six non-carious extracted premolars were randomly assigned to four groups of nine teeth: group 1, no treatment on the occlusal surface; group 2, acid etching for 15 seconds; group 3, Er:YAG laser irradiation; group 4, acid etching followed by Er:YAG laser irradiation. The pits and fissures were sealed with unfilled sealant(Helioseal F) and the specimen teeth were thermo-cycled, immersed in 2% Rhodamine B solution, longitudinally sectioned and analyzed for microleakage with fluorescent microscope. The results were as follows: 1. Er:YAG lased surfaces with 50mJ, 3Hz showed a similar pattern of irregularity with acid etched enamel surfaces 2. The mean microleakage score increased in the order of group 2, 4, 3 and 1. There was no significant difference among group 1, 3 and 4(p>0.05), however group 2 showed significantly less microleakage compared with group 1 and 3. Conclusively, the laser irradiation seemed not enough to replace the acid etching for proper retention of pit and fissure sealants.

  • PDF

A Study on Concentration and Application Time of Lithium Sulfate-Contained Polyacrylic Acid for Adequate Crystal Growth (법랑질 표면에 크리스탈을 형성시키기 위해 사용한 황산리튬이 함유된 폴리아크릴산의 농도와 적용시간에 관한 연구)

  • Roh, Joung-Sub;Kim, Sang-Cheol;Tae, Ki-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.6 s.71
    • /
    • pp.947-954
    • /
    • 1998
  • The purpose of this study was to compare shear bonding strengths and debonding patterns of the ceramic brackets attached on the crystal which were grown on the enamel surface of a tooth with different concentrations of lithium sulphate-contained polyacrylic acid in different application times. Four kinds of concentrations of mixed solutions were made and applied to the enamel surface on extracted human premolars. The solutions were made by adding 0.3M or 0.6M of lithium sulfate to $50\%\;or\;65\%$ of polyacrylic acid with 0.3M sulfuric acid. The solutions were applied for 30 or 60 seconds. After bonding, a universal testing machine was used to measure the shear bond strength, and then observations were made of debonding patterns through the stereoscope. And the enamel surface was observed through the scanning electron microscope to examine the pattern of crystal growth and debonding. The results were as follows: 1. Shear bond strength in the enamel surface treated with $50\%$ polyacrylic acid was higher than that with $65\%$ polyacrylic acid. 2. There were no statistical differences in shear bond strength according to concentration of lithium sulfate and application time of solutions . 3. Enamel surface was almost free of resin debris after debonding. 4. Enamel surface treated with $50\%$ polyacrylic acid showed higher density of crystal growth than that with $65\%$ polyacrylic acid under scanning electron microscope.

  • PDF

IN VITRO STUDY ON THE EFFECTS OF THE FLOURIDE ON THE REMINERALIZATION OF ACID ETCHED ENAMEL (불소가 산부식된 법랑질의 재석회화에 미치는 영향에 관한 연구)

  • Kim, Jin-Han;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.26 no.4
    • /
    • pp.389-399
    • /
    • 1996
  • Remineralization of acid-etched enamel across the time has been one of the curiosities in the context of the orthodontic biomechanics(Arends J. et al., IRL Press, 1, 1985), nevertheless, is so far controversial. It was the aim of this study to observe the remineralization patterns of acid-etched enamel across the time and whether the existence of fluoride might carry out any modifications. The intact buccal surfaces of the first bicuspids which was extracted for orthodontic treatment were ground smooth, and etched with a 38w/w% phosphoric acid for 60 seconds, The surface was observed by the scanning electron microscope and surface microhardness was measured after immersion in the fluoride or non-fluoride containing remineralizing solution for 0 hour, 12 hours, 1 day, 3 days, 7 days, 14 days, 28 days, and 42 days. The following results and conclusions were drawn; 1. Surface microhardness increased in both fluoride containing and non-fluoride containing solution group with time lapse. 2. In fluoride containing solution group, the surface microhardness sharply increased at the 12 hours group, on the other hand, surface microhardness increased at 3 days in non-fluoride containing solution group. 3. The difference in microhardness value between two groups manifested gradual decrease. 4. Scanning electron microphotographs disclosed that the fluoride containing solution group generated spiculate sub-stances in the 12 hours group, which was increased in number and size with time lapse. 7 days later, spherical composure was began to be produced, The spiculate substances so much increased in number that the etched enamel surface looked like flat in 42 days. 5. In non fluoride-containing solution group, there was no surface change at 42 days, perceivable in scanning electron microphotographs which could be defined as remineralization though the surface was a little rougher than the incipient etched surface. These results demonstrate that the action of the fluoride is exceedingly pertinent in the remineralization of acid-etched enamel and the remineralization process goes uninterruptedly with time lapse.

  • PDF

A study on enamel thickness of maxillary incisors using X-ray micro computed tomography (MicroCT를 이용한 상악 전치의 법랑질 두께에 관한 연구)

  • Cho, Young-Won;Cho, Jin-Hyun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.301-307
    • /
    • 2010
  • Purpose: The objectives of the current study are to assess the accuracy of X-Ray Micro Computed Tomography (microCT) in measuring enamel thickness and to evaluate enamel thickness in maxillary incisors of Koreans. Materials and methods: Five maxillary incisors were embedded in resin block. These teeth were longitudinally sectioned labiolingually through the medial axis. After polishing, the teeth were scanned using a microCT (X-EYE SYSTEM; DRGEM, Seoul, Korea). On a scanning electron microscope (S-4300; Hitachi, Tokyo, Japan) (${\times}20$) and a microCT, nearly identical planes were reconstructed. In each tooth, the thickness of labial enamel was measured 1, 3 and 5 mm above the cementoenamel junction (CEJ). Thus, the accuracy of the microCT was evaluated. In addition, using 26 maxillary central incisors and 11 maxillary lateral incisors, in the medial axis and 2 mm remote areas mesially and distally from the medial axis, the thickness of labial enamel was measured 1, 3 and 5 mm above the CEJ along the long axis of the teeth. Results: Measurements from nearly identical planes in physical and microCT sections differed by 3.81%. An independent t-test was performed and this showed that there were no significant differences in the measurements between the two methods. Mean values of labial enamel thickness in maxillary central incisors 1, 3 and 5 mm above the CEJ were $0.32{\pm}0.01$, $0.50{\pm}0.0.2$ and $0.70{\pm}0.02\;mm$, respectively. Mean values of labial enamel thickness in maxillary lateral incisors 1, 3 and 5 mm above the CEJ were $0.30{\pm}0.01$, $0.55{\pm}0.03$ and $0.80{\pm}0.02\;mm$, respectively. Conclusion: In measuring enamel thickness, microCT is one of useful way of measurement. So according to the results of this research, when restoring a porcelain laminate veneer on maxillary incisors in Koreans, careful consideration is needed in the amount of enamel reduction.

EFFECT OF APPLICATION METHODS OF A SELF-ETCHING PRIMER ADHESIVE SYSTEM ON ENAMEL BOND STRENGTH (자가부식 프라이머 접착제의 적용방식이 법랑질의 결합강도에 미치는 영향)

  • Park, Jae-Gu;Cho, Kwon-Hwan;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.90-97
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of passive or active application of primer and coat times of bond on the shear bond strength when a self-etching primer adhesive (Clearfil SE Bond) was applied to enamel surface. Crowns of sixteen human molars were selected. Buccal and lingual enamels of crowns were partially exposed and slabs of 1.2 mm thick were made. They were divided into one of four equal groups (n = 8). Group 1: passive application of Primer and 1 coat of Bond, Group 2: active application of Primer and 1 coat of Bond, Group 3: passive application of Primer and 2 coats of Bond, Group 4: active application of Primer and 2 coats of Bond. Clearfil AP-X was bonded to enamel suface of each group using Tygon tubes. The bonded specimens were subjected to microshear bond strength (uSBS) testing with a crosshead speed of 1 mm/min. The results of this study were as follows; 1. The uSBS of Group 1 was the lowest among groups and the uSBS of Group 4 was the highest. 2. There was not statistically significant interaction between enamel uSBS by application method of Primer and coat time of Bond (p > 0.05). 3. There was not statistically significant difference between enamel uSBS by passive and active application of Primer (p > 0.05). 4. There was statistically significant difference between enamel uSBS by one- and two-coat of Bond (p < 0.05).