• Title/Summary/Keyword: 밸브 회전

Search Result 87, Processing Time 0.021 seconds

Design and Performance Test of a Closed Loop Thermal Control System for Thermal Vacuum Chamber (열진공 챔버용 폐회로 열제어시스템 설계 및 성능평가)

  • Seo, Heejun;Cho, Hyokjin;Park, Sungwook;Moon, Gueewon;Jung, Sanghun;Huh, Hwanil
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.1
    • /
    • pp.88-97
    • /
    • 2016
  • A closed loop thermal control system simulates space thermal environment to verify the satellites' functionality in extremely cold/hot temperature. It is composed of a cryogenic blower, thermal shroud, heater, cryogenic valves. This paper presents an overview of closed loop thermal control system's design parameter and test results for control parameter. A capacity of blower is calculated through energy balance equation and an advantage/disadvantage for a shroud material and a type was analysed. The thermal control system is controlled by a constant density of fluid in the system. A requested performance of closed loop thermal control system was verified by measuring a homogeneity and stability of shroud through control parameter such as density and RPM of blower.

Development of Analysis Model of Pressure·Flow-controlled Swash Plate Type Pump for Evaluating Feasibility of Design (설계 타당성 검토를 위한 압력·유량 제어형 사판식 피스톤 펌프의 해석모델 개발)

  • Lee, Geun-Ho;Noh, Dae-Kyung;Park, Sung-Su;Lee, Dae-Hee;Jin, Jung-Man;Jang, Joo-Sup
    • Journal of the Korea Society for Simulation
    • /
    • v.25 no.4
    • /
    • pp.53-63
    • /
    • 2016
  • This study aims to verify the feasibility of design by developing pressure flow-controlled swash plate type pump with the use of SimulationX, a computer analysis program. Developing analysis model based on design drawing data has a cost-saving effect because it is possible to figure out the effectiveness of design through the work and it never falls into repeated inaccuracies in the production process. Analysis model is developed in the following order. First, the structure of each part such as valve and rotating unit which have dynamic factor is analyzed and the modeling of single component is carried out, reflecting drawing data. Second, the modeling of pump assembly is carried out with the combination of each analysis model and a work is conducted to determine whether the modeling can perform pressure flow control function according to load condition smoothly based on design intent. At the end of the modeling process, the feasibility of design is verified by showing the parts which are moving as expected mechanism.

Suggestion of Procurement Strategy with Commodity Classification by Peter Kraljic Matrix (피터 크랄직 매트릭스 기법에 의한 자재 분류를 활용한 구매 전략 제안)

  • Choi, Hyun Koo;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.11 no.3
    • /
    • pp.53-63
    • /
    • 2015
  • 구매자는 일반 제조업에서 자재를 피터 크랄직 매트릭스 기법에 의해 경쟁품목, 일반품목, 전략품목, 위험품목으로 분류한 후 각 품목 특성에 맞추어 구매 전략을 수립한다. 피터 클라직 매트릭스란 구매 리스크와 비즈니스 영향도 즉 특정 품목의 구매 금액 비중에 따라 자재를 분류하는 기법이다. 본 논문은 플랜트 엔지니어링산업에서 플랜트 기자재를 대상으로 피터 클라직 매트릭스 기법에 의해 기자재를 분류한 후 각 품목 특성에 맞는 구매 전략을 제안하고 사례 기업인 A사가 사우디아라비아에서 수행하는 발전 플랜트 기자재에 제안한 구매 전략을 적용하여 그 효과를 검증한 것이다. 플랜트 엔지니어링산업은 수주산업인데 총 수주금액 중 구매가 차지하는 비중은 약 50~60%이다. 따라서 프로젝트를 수행할 때 원가를 절감하여 이익을 극대화하기 위해 구매는 매우 중요한 역할을 한다. 플랜트 기자재는 크게 회전기계류, 고정장치류, 전기자재류, 제어자재류, 배관자재류로 구분된다. 각 공종별 플랜트 기자재에 대해 구매 지출 분석을 한 후 피터 클라직 매트릭스 기법에 의해 플랜트 기자재를 분류한 결과 경쟁품목에는 열교환기, 저장탱크 등이 포함되었고 일반품목에는 전선관, 조명기자재, 밸브 등이 포함되었다. 또한 전략품목에는 가스터빈, 가스터빈 흡입공기 냉각장치 등이 포함되었고, 위험품목에는 가스터빈 고정 볼트 등이 포함되었다. 경쟁품목 중 다관형 열교환기는 공급자와 공동으로 원가 모델을 구축하는 전략을 수립했고 저장탱크의 경우에는 공급자에게 원자재를 사급하는 전략을 수립하였다. 그 전략을 A사가 수행하는 프로젝트에 적용한 결과 각각 20%와 6%의 원가 절감 효과를 얻었다. 일반품목 중 전선관은 구매 대행사를 활용하는 전략을 수립했고 조명기자재는 기술 사양 검토 과정을 생략한 구매 프로세스 간소화 전략을 수립하였다. 그 결과 약 10%의 원가 절감과 평균 5일의 발주기간을 단축할 수 있었다. 전략품목 중 가스터빈 흡입공기 냉각장치는 공급자와 포괄적 양해각서를 체결하여 공동으로 사업주에 대응하는 전략을 수립했고 그 결과 프로젝트 수행 안정성 확보와 공급자 조기 참여를 통한 발주 스케줄 단축을 이룰 수 있었다. 위험품목 중 가스터빈 고정볼트는 재고 확보 전략을 수립하여 자재의 부족이나 파손으로 인해 프로젝트 공기에 영향을 주지 않도록 리스크를 감소시키는 효과를 얻었다.

  • PDF

Development of Static Seal for a Liquid Rocket Engine (액체 로켓 엔진 스태틱 실 개발)

  • Jeon, Seong Min;Yoon, Suk-Hwan;Chung, Taegeum
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.4
    • /
    • pp.53-59
    • /
    • 2022
  • Static seals are used to seal high temperature gas and cryogenic fluid under high pressure, at interfaces between liquid rocket engine components such as combustion chamber, turbopump, gas generator, valves, etc. As thermal expansion and contraction at assembly interfaces cause undesirable leakage under cryogenic and high temperature environments, static seals applied for sealing of joint interfaces without relative motion should be designed properly. The additional function of rotation at the sealing face is also required for static seals, when the spherical flange is used for improvement of assembly at misalignment interfaces. In this study, structural analysis and leak tightness test of simulating test rig for several important interfaces are performed, to verify structural integrity of static seals.

Efficient way to clean Solder Printer Nozzles

  • Kim, Young-Min;Kim, Chi-Su
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.11
    • /
    • pp.115-121
    • /
    • 2022
  • In surface mount technology (SMT), the screen printer, which is an equipment for applying solder cream, has a lot of poor coating as the pad becomes smaller. To solve this problem, a jet printer is being used recently. However, if the nozzle at the end of the valve applied to the jet printer head is not cleaned, solder cream remains or an error occurs. To prevent this, the nozzles should be cleaned periodically. In this paper, a more stable cleaning method than the existing technology is presented for the stable application of solder cream on a jet printer. In this method, cut a 35mm wide mujin cloth, wrap it in a roll, and rotate it with a DC geared motor on the other side to clean it. As a result, it was confirmed that the solder paste was not left on the nozzle surface and was well wiped when cleaning with about 2,000 dotting cycles.

An Experimental Study on Friction Welding and Heat Treatment of Engine Exhaust Valve Steels ( SCr4-21-4 N , SUH3-21-4-N (기관배기 밸브용 강 ( SCr4-21-4N , SUH3-21-4N ) 의 마찰압접과 열처리에 관한 실험적 연구)

  • 오세규
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.2
    • /
    • pp.79-87
    • /
    • 1978
  • This is an experimental study on friction welding and heat treatment of engine exhaust valve materials whose welding combination is SCr4 as stem to 21-4N as head and SUH3 to 21-4N. In this study, not only the experiments of friction welding under the selected optimum welding condition and the examination of the mechanical properties were carried out, but also the heat treatment of friction welded specimens under the two selected conditions was taken to obtain the better welding character, eliminating the latent stress and the hardness peak which appeared at the welded zones of heat resisting steel(21-4N, SUH3) and low alloyed steel ($SCr_4$) friction weldments. The results obtained by the experiments and consideration in this study are as follows: I) It was experimentally proved quite reasonable that 'speed=3,OOO rpm, heating pressure Pl=8 kg/ mm2, upsetting pressure p, = 20 kg/mm', heating time $t_1$ = 3 see, upsetting time TEX>$t_2$ = 2.5 sec' was selected as the optimum welding condition for friction-welding the engine exhaust valve materials $SCr_4$ to 21-4 Nand SUH 3 to 21-4 N. 2) The results of the previous study and this one on friction welding of such dissimilar materials as SUH 3-SUH 31, SCr 4-SUH 31, SCr 4-SUH 3, SUH 3-CRK 22, SCr4-21-4 Nand SUH3-21-4 N agreed with each other substantially in the friction welding characteristics at welded interface zones. 3) It was also certified quite satisfactory that '600\ulcornerCX30 min. Xroom air cooling' as an optimum heat treatment condition of the friction welded materials SCr 4-21-4 Nand SUH 3-21-4 N was experimentally determined to eliminate the latent stress and the hardness peak at welded zones. 4) About 20% of the tensile strength before heat treatment of friction welded specimens was decreased after heat treatment 600\ulcornerCX30 min. Xair cooling, but the location of fracture was moved from heat affected zone to parent $SCr_4$ & SUH3. 5) Microscopic examination of the weld joints friction-welded and heat-treated under the above mentioned conditions revealed that the weld zone is very narrow and has a fine grained intermixed structure without any welding defects. 6) The above mentioned conditions can be also utilized as friction welding parameters of the other dissimiar materials for engine valve production.

  • PDF

Experimental Study of Adoption of Alternative Refrigerant for Avionic Equipment Cooling System (항공전자기기용 냉각시스템의 대체냉매 적용에 관한 실험적 연구)

  • Kang, Hoon;Jung, Jongho;Jung, Minwoo;Chi, Yongnam;Yoo, Yongseon;Choi, Heeju;Byeon, Youngman;Kim, Youngjin;Oh, Kwangyoon;Kim, Yongchan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.431-439
    • /
    • 2013
  • A cooling system is adopted to control the thermal load from the avionic equipments in an aircraft for stable operation. In this study, an avionic cooling system was designed and manufactured by adopting a vapor compression cycle with a closed-loop air-circulation system to investigate the operating characteristics of an alternative refrigerant. The performance characteristics of a cooling system adopting R236fa as an alternative refrigerant were experimentally determined by varying the refrigerant charging amount, expansion valve opening, and compressor rotation speed. The experimental results were analyzed and compared with those of a cooling system adopting R124 as a refrigerant. The possibility of the adoption of R236fa as an alternative refrigerant was verified, and design solutions were suggested to improve the system efficiency.