• Title/Summary/Keyword: 배연시설

Search Result 32, Processing Time 0.035 seconds

Control of NOx Emission in a Copper-Alumina Catalytic Filter Reactor (Copper-Alumina 촉매필터 반응기에서의 NOx 제어)

  • 류동길;이상권
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.263-264
    • /
    • 2002
  • 연소시설에서 배연가스중의 NOx 배출을 저감하기 위하여 선택적 촉매 환원법(SCR)과 선택적 무촉매 환원법(SNCR)이 널리 이용되고 있다. 이러한 촉매처리는 Pt와 같은 귀금속이 포함된 촉매 하에서 암모니아를 환원제로 사용하였으나, R와 같은 귀금속의 경우 배연가스내에 함유된 중금속이나 비소(Arsenic), SOx, 비산재(fly ash)등에 의해 쉽게 비활성화(deactivation)되는 단점이 있다(Sumitra R et al., 1995). (중략)

  • PDF

A Study on the Effective Fire and Smoke Control in Semi-Transverse Ventilation (균일배기 환기방식에서의 배연특성에 관한 연구)

  • Jeon, Yong-Han;Kim, Jong-Yoon;Seo, Young-Ho;Yoo, Oh-Ji;Han, Sang-Pil
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.90-94
    • /
    • 2010
  • In this study it is intended to review the moving characteristics of smoke by performing visualization simulation for the calculation of the optimal smoke exhaust air volume in case a fire occurs in tunnels where transverse ventilation is applied, and to obtain basic data necessary for the design of smoke exhaust systems by deriving optimal smoke exhaust operational conditions under various conditions. As a result of this study, if it was assumed 0 critical velocity in the tunnel, the smoke exhaust air volume was limited within 250 meter in the road-tunnel disaster prevention indicator and the exhaust efficiency was from 55.1% to 95.8% in the result of this study. If the wind velocity is in the tunnel, the exhaust rate intends to increase rapidly and the exhaust efficiency is decreased. In addition, if the wind velocity is increased, the exhaust rate should be increased in compared with the generation rate of smoke in maximum 1.8 or 1.04 times. In this study, when the wind velocity is in the tunnel, the limited exhaust rate is $84m^3/s{\cdot}250m$. And if it was assumed 1.75 m/s critical velocity in the tunnel, the exhaust rate would be defined $393m^3/s{\cdot}250m$($Q_E$ = 80 + 5Ar).

Micrometeorology Analysis of Pear Orchard with Anti-insect Nets for Non-bagged Cultivation (망 시설 유무에 따른 배 과원의 미기상 분석)

  • Yu, Seok-cheol;Choi, Jin-ho;Lee, Han-chan;Lee, Ug-young
    • Journal of Bio-Environment Control
    • /
    • v.28 no.2
    • /
    • pp.150-157
    • /
    • 2019
  • This study was carried out to investigate at the micrometeorology change of the orchard according to the net installation. Two weather stations were installed at the inside of the anti-insect nets(2 mm, 4 mm), one was installed at the outside(control). They were observed the temperature, humidity, wind speed and solar radiation from April to September 2018. Daily mean temperature at the experimental group was higher than control group by $0.2^{\circ}C$. Daily mean humidity at the experimental group was higher than control group by 3.5 to 4.7%. Daily mean the solar radiation at the experimental group(2 mm) was lower than control group by 50%. The wind speed was decreased from 12% to 50% of the external wind speed at 4 mm, and from 25% to 59% at 2 mm.

Retraction: A numerical study on the fire smoke behavior by operating the fire prevention system in tunnel-type structure (논문 취소: 터널형 구조물의 방재시설 가동에 따른 화재연기 거동에 관한 수치 해석적 연구)

  • Lee, Ho-Hyung;Choi, Pan-Gyu;Lee, Sang-Don;Heo, Won-Ho;Jo, Jong-Bok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.189-199
    • /
    • 2019
  • In this study, behaviors of fire smoke in the operation of disaster prevention facilities (smoke damper, jet fan) in a tunnel-type structure (soundproof tunnel) were investigated numerically and results of the investigation were compared and analyzed. Through the simulation and analysis, it was found that there was a significant change in the patterns of fire smoke between the opening of the ceiling of a fire vehicle and the closing, and it was shown that the critical temperatures of PC and PMMA, main materials of a soundproof tunnel were not exceeded. In addition, the simulation of installation intervals of smoke dampers showed that the maximum temperature of a soundproof tunnel without smoke dampers was $552^{\circ}C$ while it reached $405^{\circ}C$ when smoke dampers were installed at the installation interval of 50 m. The simulation of the operation of a jet fan showed that the maximum temperature of a soundproof tunnel without a jet fan was $549^{\circ}C$ while it reached only $86^{\circ}C$ when a jet fan was operating. Therefore, it is highly expected that they could create a favorable environment for evacuation and protection of soundproofing materials, and it would be necessary to promote basic studies on tunnels serving various functions and purposes.

A Study on Facilites Safety of Long-Term Care Facilities for Elderly :Focused on the Factual Survey of Seoul Metropolitan Area (장기요양시설의 노인보호를 위한 시설안전에 관한 연구 : 수도권 시설안전 실태조사를 중심으로)

  • Moon, Yongpil
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.10
    • /
    • pp.308-325
    • /
    • 2020
  • This study examines factual facilites safety of long-term care facilities for eldery, for improvement of Korean policy. So, This study reviewed policies of facilites safety of long-term care facilities on main OECD countries. We analyzed factual survey of facilites safety of long-term care facilities in Seoul metropolitan area. The results of the study were as follows: First, There were differences of law and rule of facilites safety of long-term care facilities in comparison with those of social welfare facilities, child day-care center, hospital. Second, it was the result of location condition analysis. Long-term care facilities in the Seoul metropolitan area were located on more than six floors of buildings. The location conditions of private facilities are weak compared to those of corporations and local governments. Third, there were the result of internal structure of facilities. Overall, the placement status was insufficient. For instance, there are smokeproof masks/fireproof blankets, smoke windows(fire safety windows), smoke smothering. In addition, there were places where legal essential installation structures were insufficient. Private facilities were generally insufficient in facility structures compared to those of local governments and welfare corporations. Fourth, there were the result of safety management. It was confirmed that private facilities were insufficient compared to local government facilities. For instance, there are safety management analysis, response manuals, fire preparedness training, etc. Finally, implications and future directions policies of facilites safety of long-term care facilities were discussed based on the finding of the study.

Additive effects on $SO_x/NO_x$ removal characteristics using plasma (첨가제 활용에 따른 플라즈마 배연탈황탈질 특성)

  • 지평삼;엄희문;장경룡;남창모;지준화;한영욱
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.260-261
    • /
    • 1999
  • 산업시설 및 대형 발전설비에서 배출되는 아황산가스 및 질소산화물은 대기환경에 직접적으로 악영향을 미칠 뿐만 아니라, 오존의 생성과 고갈, 산성비의 출현등으로 지구 온난화와 같은 기후변화에 크게 기여하는 것으로 보고되고 있다. 기존의 습식 석회/석회석 탈황공정(FGD) 및 선택적 촉매/비촉매 탈질기술(SCR/SNCR)은 효과적인 상용기술로서 널리 연구개발되어 왔으나, 대단위 시설투자와 고비용, 2차 오염물질의 배출이 단점으로 지적되고 있다(Nam, 1999).(중략)

  • PDF

Experiments on the Influence of Opening of Natural Smoke Ventilators on the Stack Effect in High-rise Mixed-use Residential Buildings (초고층주상복합건물에서 배연창 개방이 연돌효과에 미치는 영향에 대한 실험적 연구)

  • Lim, Chae-Hyun;Kim, Bum-Gyu;Park, Yong-Hwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.3
    • /
    • pp.89-94
    • /
    • 2009
  • The stack effect in high-rise buildings is expected more significant at nights in winter due to the large temperature difference between the inside and outside of the buildings. However, the existence of large openings such as natural ventilators on the floor may effect the position of neutral plane, smoke spread at fire and thus obstruct the door openings for rescue. In this paper, the vertical and horizontal pressure distribution with different openings of natural smoke ventilators was experimentally analyzed by investigating pressure differentials.

Practical Study of the Thermal Efficiency Improvement and the White Plume Removal from Flue Gas by Fuel Additive Injection (연료첨가제를 이용한 열효율향상 및 가시백연 제거에 관한 연구)

  • 전상기;조승원;황영호
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.487-488
    • /
    • 2003
  • 우리나라 대기환경기준이 점차 강화되고 있고, 국민의 욕구수준 또한 선진국 수준으로 강화될 계획으로 있어 이에 따른 대기오염 방지시설의 설치 또는 보완이 요구되고 있다 특히, 배기가스 중 황산화물 및 질소산화물 배출농도 강화로 울산화력발전소에서는 최신의 배연탈황ㆍ탈질설비를 가동중에 있으나 황산 Mist가 주요원인으로 추정되는 Plume Opacity가 발생되어 오염물질 배출농도는 법적규제기준 이내로 배출되더라도 민원이 발생되고 있다. 이에 대한 대책으로 현장에 적합한 연료첨가제 주입으로 Plume Opacity 발생원인을 제거함과 동시에 배연탈황설비에서 발생된 저온부식 현상을 개선하고, 보일러 내 고온부식 등 연소장애 현상 개선을 통한 열효율 향상 방안에 대해 연구하였다. (중략)

  • PDF