• Title/Summary/Keyword: 배관 깊이

Search Result 68, Processing Time 0.042 seconds

Effect of the PIG Moving on the Defect Signals in MFL NDT System (자기 누설 비파괴 탐상 시스팀에서 PIG의 이동이 검출신호에 미치는 영향)

  • Park, Sang-Ho;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.879-881
    • /
    • 2002
  • 배관의 PIG시스템은 비파괴검사로써 배관내부에 삽입되어 내부 매체에 의하여 추진되는 장치로서 영구자석을 이용한 자기회로를 형성하여 결함이 있을 때 누선자속을 검출하여 이를 해석하여 배관내의 결함의 크기와 깊이를 검출할 수 있다. 그러나 실제 검출신호는 PIG가 이동시 이동속도에 따른 와전류 문제와 가스관의 착자에 따른 히스테리시스특성에 따른 신호들이 실제 결함에 의한 신호를 왜곡시키게 된다. 본 연구에서는 PIG 의 이동에 따른 이동속도에 따른 와전류 문제와 히스테리시스특성이 검출신호를 왜곡하는 현상에 대하여 연구 하였다.

  • PDF

Estimation of Local Stress Change of Wall-Thinned Pipes due to Fluid Flow (유체유동에 의한 감육배관의 국부응력변화 평가)

  • Kim Young-Jin;Song Ki-Hun;Lee Sang-Min;Chang Yoon-Suk;Choi Jae-Boong
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.7-12
    • /
    • 2006
  • In this paper, a new evaluation scheme is suggested to estimate load-carrying capacities of wall thinned pipes. At first, computational fluid dynamics analyses employing steady-state and incompressible flow are carried out to determine pressure distributions in accordance with conveying fluid. Then, the variational pressures are applied as input condition of structural finite element analyses to calculate local stresses at the deepest point. The efficiency of proposed scheme was proven from comparison to conventional analyses results and it is recommended to consider the fluid structure interaction effect for exact integrity evaluation.

  • PDF

Determination of an Test Condition for IR Thermography to Inspect a Wall-Thinning Defect in Nuclear Piping Components (원전 배관 감육 결함 검사를 위한 IR 열화상시험 조건 결정)

  • Kim, Jin-Weon;Yun, Won-Kyung;Jung, Hyun-Chul;Kim, Kyeong-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.12-19
    • /
    • 2012
  • This study conducted infrared (IR) thermography tests using pipe and plate specimens with artificial wall-thinning defects to find an optimal condition for IR thermography test on the wall-thinned nuclear piping components. In the experiment halogen lamp was used to heat the specimens. The distance between the specimen and the lamp and the intensity of halogen lamp were regarded as experimental parameter. When the distance was set to 1~2 m and the lamp intensity was above 60 % of full power, a single scanning of IR thermography detected all artificial wall-thinning defects, whose minimum dimension was $2{\Theta}=90^{\circ}$, d/t=0.5, and $L/D_o=0.25$, within the pipe of 500 mm in length. Regardless of the distance between the specimen and the lamp, the image of wall-thinning defect in IR thermography became distinctive as the intensity of halogen lamp increased. The detectability of IR thermography was similar for both plate and pipe specimens, but the optimal test condition for IR thermography depended on the type of specimen.

A Study on Determining the Shape of Small Axial Cracks by using Magnetic Flux Leakage in NDT System for Underground Pipe (배관용 자기누설 비파괴 검사에서 축방향 미소결함의 형상 판정에 관한 연구)

  • Kim, Hui Min;Park, Gwan Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.1
    • /
    • pp.18-25
    • /
    • 2013
  • MFL PIG (Magnetic Flux Leakage Pipeline Inspection Gauge) is called the system which detects the defect for underground pipelines by using magnetic flux leakage method in nondestructive testing. This method is very suitable for testing pipelines because pipeline has high magnetic permeability. MFL PIG generates the magnetic fields to the pipe axially oriented, and detect the signal of leakage flux by using hall sensor. However, MFL PIG is hard to detect the axially oriented crack with small size because the magnetic flux leakage is not enough to be occurred. To detect the small size and axially oriented crack, the circumferential MFL (CMFL) PIG is being proposed and it can maximize the leakage flux for the axial crack by performing magnetic fields circumferentially on the pipe. In this paper, CMFL PIG is applied to detect the axially oriented crack with small size and the analysis for the distribution and the amplitude of the leakage flux signal is performed by using three dimensional finite element method. From sensing signals, the method how to determine the shape of axially oriented cracks is proposed and verified with experiment.

A Development Inspection Management Operation Model of High Pressure Underground Pipeline in Industrial estate (산업단지 고압매설배관의 점검 관리 운영 모델 개발)

  • Choi, Ji-Hun;Kim, Jin-Jun;Rhie, Kwang-Won;Kim, Tae-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.1
    • /
    • pp.62-69
    • /
    • 2019
  • The high pressure underground pipelines of industrial states such as Ulsan, Yeosu consist with not only the pipelines for the utility support such as Raw material of petrochemical industry and steam, but also high pressure pipelines of toxic, flammable gas intricately like a web. Therefore, in this study, based on in-depth comparison analysis of industrial estate pipelines, and underground city gas pipelines' safety management status, excavation frequency, excavation depth, patrol period which are pipe damage impact factor by the other construction are analyzed. And, as a result, risk changes and correlations due to risk reduction strategy of the other construction are compared to be presented the safety inspection operation model for the high pressure underground pipelines of industrial estates.

Application of Laser Ultrasonic Technique for Nondestructive Evaluation of Wall Thinning in Pipe (배관부 감육 손상의 비파괴 평가를 위한 레이저 초음파 기술 적용)

  • Hong, Kyung-Min;Kang, Young-June;Park, Nak-Kyu;Yoon, Suk-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.361-367
    • /
    • 2013
  • Many of the nuclear power plant pipe is used in high temperature and high pressure environment. Wall thinning frequently caused by the corrosion. These wall thinning in pipe is expected gradually increase as nuclear power become superannuated. Therefore there is need to evaluate wall thinning in pipe and corrosion defect by non-destructive method to prevent the accident of the nuclear power facility due to pipe corrosion. Especially for real-time assessment of the wall thinning that occurs in nuclear power plant pipe, the laser ultrasonic technology can be measured even in hard-to-reach areas, beyond the limits of earlier existing contact methods. In this study, the optical method using laser was applied for non-destructive and non-contact evaluation. Ultrasonic signals was acquired through generating ultrasonic by pulse laser and using laser interferometer. First the ultrasonic signal was detected in no wall thinning in pipe, then a longitudinal wave velocity was measured inside of pipe. Artificial wall thinning specimen compared to 20, 30, 40 and 50% of thickness of the pipe was produced and the longitudinal wave velocity was measured. It was possible to evaluate quantitatively the wall thinning area(internal defect depth) cause it was able to calculate the thickness of each specimen using measured longitudinal wave velocity.

Application Angle of Defects Detection in the Pipe Using Lock-in Infrared Thermography (위상잠금 적외선 열화상 기법을 이용한 각도별 원전 감육 배관의 결함 검출)

  • Yun, Kyung-Won;Go, Gyeong-Uk;Kim, Jin-Weon;Jung, Hyun-Chul;Kim, Kyung-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.323-329
    • /
    • 2013
  • This perform research of angle rated defect detection conditions and nuclear power plant piping defect detection by lock-In infrared thermography technique. Defects were processed according to change for wall-thinning length, Circumference orientation angle and wall-thinning depth. In the used equipment IR camera and two halogen lamps, whose full power capacitany is 1 kW, halogen lamps and target pipe's distance fixed 2 m. To analysis of the experimental results ensure for the temperature distribution data, by this data measure for defect length. Reliability of lock-In infrared thermography data is higher than Infrared thermography data. This through research, Shape of angle rated defect is identified industry place. It help various angles defect detection in the nuclear power plant in operation.

GMR Sensor Applicability to Remote Field Eddy Current Defect Signal Detection in a Ferromagnetic Pipe (강자성 배관의 원격장 와전류 결함 신호 검출에 GMR Sensor의 적용성 연구)

  • Park, Jeong Won;Park, Jae Ha;Song, Sung Jin;Kim, Hak Joon;Kwon, Se Gon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.483-489
    • /
    • 2016
  • The typical methods used for inspecting ferromagnetic pipes include the ultrasonic testing (UT) contact method and the following non-contact methods: magnetic flux leakage (MFL), electromagnetic acoustic transducers (EMAT), and remote field eddy current testing (RFECT). Among these methods, the RFECT method has the advantage of being able to establish a system smaller than the diameter of a pipe. However, the method has several disadvantages as well, including different sensitivities and difficult-to-repair coil sensors which comprise its array system. Therefore, a giant magneto-resistance (GMR) sensor was applied to address these issues. The GMR sensor is small, easy to replace, and has uniform sensitivity. In this experiment, the GMR sensor was used to measure remote field and defect signal characteristics (in the axial and radial directions) in a ferromagnetic pipe. These characteristics were measured in an effort to investigate standard defects at changing depths within a pipe. The results show that the experiment successfully demonstrated the applicability of the GMR sensor to RFECT signal detection in ferromagnetic pipe.

AE Characteristic of Polyethylene Pipe under various defects (다양한 결함에 대한 폴리에틸렌 배관의 음향방출 특성)

  • Nam Ki Woo;Lee Si Yoon;Ahn Seok Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.3 s.24
    • /
    • pp.1-7
    • /
    • 2004
  • The polyethylene pipe can use semi-permanent because of the high corrosion resistance with chemical stability. In addition to, there is the merit that is an easy to establish and to maintain. However, as the reason that it is simply degraded when the polyethylene pipe was exposed to the outside, mainly it is used to lay under the ground with low-pressure gas transportation pipe. In this study, the nondestructive evaluation method was used to maintain the integrity of the polyethylene pipe. We simulated the various defects on the polyethylene pipes, and then the AE signal occurred according to the impact test of steel ball was evaluated by the acoustic emission method. From the results, the waveform and dominant frequency could be distinguishing from the defect shapes of polyethylene pipe. Especially, in the case of notch defect, the AE signals occur different by the angle and depth of the notch.

  • PDF

Analysis of Dispersion Characteristics of Circumferential Guided Waves and Application to feeder Cracking in Pressurized Heavy Water Reactor (원주 유도초음파의 분산 특성 해석 및 가압중수로 피더관 균열 탐지에의 응용)

  • Cheong, Yong-Moo;Kim, Sang-Soo;Lee, Dong-Hoon;Jung, Hyun-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.307-314
    • /
    • 2004
  • A circumferential guided wave method was developed to detect the axial crack on the bent feeder pipe. Dispersion curves of circumferential guided waves were calculated as a function of curvature of the pipe. In the case of thin plate, i.e. infinite curvature, as the frequency increases, the $S_0$ and $A_0$ mode coincide and eventually become Rayleigh wave mode. In the case of pipe, however, as the curvature increases, the lowest modes do not coincide even in the high frequencies. Based on the analysis, a rocking technique using angle beam transducer was applied to detect an axial defect in the bent region of PHWR feeder pipe. Based on the analysis of experimenal data for artificial notches, the vibration modes of each signal were identified. It was found that the notches with the depth of )0% of wall thickness can be detected with the method.