• 제목/요약/키워드: 배관설치

Search Result 297, Processing Time 0.029 seconds

Seismic Performance Evaluation of Multi-Story Piping Systems using Triple Friction Pendulum Bearing (지진격리장치를 적용한 복층구조파이핑 시스템의 내진성능평가)

  • Ryu, Yonghee;Ju, Buseog;Son, Hoyoung
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.4
    • /
    • pp.450-457
    • /
    • 2018
  • Purpose: The evaluation of seismic performance of critical structures has been emerging a key issue in Korea, since a magnitude 5.8 earthquake, the worst in Koran history, struck Gyeongju, southern area in Korea on september 12th, 2016. In particular, the catastrophic failure of nonstructural components such as sprinkler piping systems can cause significant economic loss or loss of life during and after an earthquake. The nonstructural components can be more fragile than structural components in seismic behavior. Method: This study presents the seismic performance evaluation of fire protection piping system, using coupled building-piping system installed with Triple Friction Pendulum Bearings (TPBs). Kobe (Japan), Kocaeli (Turkey), and GyeongJu (Korea) were selected to consider the uncertainty of ground motions in this study. Result: In the simulation results, it was observed that the reduction of maximum displacements of the piping system with the TPBs' system was significant: Kobe, Kocaeli, and Gyeongju cases were 49%, 14.4% and 21.5%, respectively. Conclusion: Therefore, using seismically isolated system in a building-piping system can be more effective to reduce the seismic risk than a normally installed building-piping systems without TPBs in strong earthquakes.

가스정책(1) - 건축물 내 매립재관 관련 수수료 인상 최소화

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.295
    • /
    • pp.90-92
    • /
    • 2015
  • 대한설비건설협회(이하 협회)는 건축물 도시가스 매립배관 설치 시 과도한 수수료 발생 문제를 지속적으로 건의한 결과 세대수에 따라 최대 84%까지 수수료를 낮추는 성과를 거뒀다. 가정에서 가스를 사용할 때 전기처럼 '콘센트'에 커플링식으로 접속해 쓰도록 하는 건축물 도시가스 매립배관 설치 규정은 건축물 미관과 범죄 방지를 위해 지난 2013년 7월 25일 도시가스사업법 시행규칙 개정에 따라 제도가 마련됐으나, 세대당 부담해야 하는 완성검사 및 기술검토 수수료가 지나치게 높게 책정됨에 따라 가스기기 사용확대라는 기대효과보다는 오히려 전기사용이 더 유리하게 되고 말았다는 지적이 끊이지 않았다. 이에따라 협회는 공동주택 세대수에 따른 수수료를 개정해줄 것을 지속적으로 건의해 왔고 산업통상자원부는 지난 1월 12일 검사수수료 고시를 통해 공동주택 세대수에 따른 수수료를 개정했다.

  • PDF

모듈식 증기발생기를 사용한 일체형 원자로의 예비 개념설계

  • 김종인;김긍구;김용완;이두정;장문희
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.275-282
    • /
    • 1996
  • 일체형 원자로는 증기발생기 및 가압기를 압력용기 내에 설치한 것으로서 연결배관이 없기 때문에 배관의 파단에 의한 대형 냉각재 상실사고를 근원적으로 배제하고 전체계통을 단순화 시킬 수 있다. 증기발생기는 대부분 관류식으로서 일체식과 모듈식이 사용되고 있다. 본 연구에서는 모듈식 나선형 증기발생기를 사용한 일체형 신형경수로의 예비 개념설계를 수행하였다. 가압기는 원자로 내에 별도의 용기를 설치하는 내장형 자기가압기를 채택하였다. 제어봉 구동장치는 핵분열 반응열을 이용한 원자로 기동을 위하여 반응도를 미세하게 조정하는 것이 가능하고 지진하중과 같은 동하중의 영향을 최소화하기 위하여 원자로용기 외부로의 돌출부분을 최소화하는 설계개념을 채택하였다. 냉각재 펌프는 Canned Motor Pump를 원자로용기 상부에 수직으로 직접 부착하는 개념을 사용하였다.

  • PDF

A Study on Failure Frequency Model for Risk Analysis of Natural Gas Pipeline with Comparison of Overseas Failure Data (국외 천연가스 배관 사고 빈도 비교 및 분석 모형에 관한 연구)

  • Oh, Shin-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.60-66
    • /
    • 2014
  • In this study, the overseas failure frequency data of the high-pressure gas pipeline were investigated to apply QRA of high-pressure gas pipeline. The typical overseas failure frequency data of high-pressure gas pipeline are DOT of United States, EGIG of Europe, and UKOPA of United Kingdom (UK). Comparative analysis of these data was shown that EGIG data was suitable for the situation in Korea. In order to apply QRA of high-pressure gas pipeline, non-linear regression analysis using the failure frequency data in the report of EGIG 8th was performed. In the future, intensive researches are required for the external interference because about 50% of the failure frequency of all incidents is the external interference, and for combining of domestic and overseas data.

A Study on the Consequences of Underground High Pressure Natural Gas Pipelines (고압 매몰 천연가스 배관 누출사고 피해해석에 관한 연구)

  • Lee, Seungkuk;Shin, Hun Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.2
    • /
    • pp.44-49
    • /
    • 2013
  • Due to rapid rise of consuming rate for natural gas, installation and operation of high pressure natural gas pipeline is inevitable for high rate of gas transportation. Accordingly incidents on the underground high pressure natural gas pipeline come from various reasons will lead to massive release of natural gas and gas dispersion in the air. Further, fire and explosion from ignition of released gas may cause large damage. This study is for release rate, dispersion and flash fire of natural gas to establish a safety management system, setting emergency plan and safety distance.

Defect Length Estimation Using SQI for Underground Gas Pipelines (SQI를 이용한 지하 매설 가스 배관 결함 길이 추정)

  • Kim, Min-Ho;Choi, Doo-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.27-32
    • /
    • 2011
  • In this paper a new defect length estimation algorithm using SQI(self quotient image) is presented for the MFL(magnetic flux leakage) inspection of underground gas pipelines. Gas pipelines are magnetized by the permanent magnets of the MFL PIG(pipeline inspection gauge) when the PIG runs through pipelines. If defects or corrosions exist in the pipeline, magnetic leakage flux is increased. The MFL signals measured by hall sensors are analyzed to estimate defect length using SQI. For 74 real defects carved in KOGAS pipeline simulation facility(KPSF) the accuracy of defect length estimation of the proposed algorithm was compared with that of conventional methods.

Application of Fiber Optic Sensors for Monitoring Deflection and Deformation of a Pipeline (배관 변형 및 처짐 감시를 위한 광섬유 센서의 활용)

  • Lee, Jin-Hyuk;Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.460-465
    • /
    • 2016
  • Long pipe structures are usually installed in fixtures located with regular intervals or laid underground. Therefore, deflection and deformation could easily occur due to their weight or ground activity. A shape monitoring technique can be used effectively to evaluate the integrity of the pipe structures. Fiber Bragg grating (FBG) sensors, which have an advantage of multiplexing could be used to measure strains at multiple-points of a long structure. In this study, to evaluate the integrity of a pipeline, a shape estimation technique based on strain information was proposed. Furthermore, different experiments were conducted to verify the performance of the proposed technique. Thus, the proposed shape estimation technique can represent the shape according to the deformation of the specimen using the FBGs. Moreover, calculated deflection of the pipeline using the estimation technique showed a good agreement with the actual deflection of the pipeline.

A Study on Performance-based Seismic Design Method of Fire Extinguishing Pipe System (소화설비 배관의 성능위주 내진설계 방법에 관한 연구)

  • Lee, Jae-Ou;Kim, Hong-Kyung;Cho, Soon-Bong
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.86-94
    • /
    • 2017
  • In the present study, a Cook Book method and a Static System Analysis method were compared with each other on the basis of a seismic design criteria of fire-fighting facilities and analyzed. The Cook Book method is analyzed by dividing a pipeline in each same section. In this method, a stress analysis is not possible except for the section analyzed in such a way that a brace is designed according to the weight of pipe, water and pipe fitting. To the contrary, in case of the Static System Analysis method, the stress analysis for the whole pipeline can be performed because the whole pipeline is regarded as a single structure. For the fatal stress values locally generated, it is necessary to actively perform a pipeline analysis by installing a device capable of locally relieving the stress of the pipeline. In Korea, only the Cook Book method is provided as the seismic design criteria of fire-fighting facilities, which causes many problems with diversification of seismic design. Thus, it is necessary to apply the seismic design method of the pipeline by using various kinds of engineered Static System Analysis methods.

Experimental Study for Seismic Behavior Analysis of a Fire Protection Riser Pipe System with Groove Joints (그루브 조인트가 설치된 수계소화설비 입상배관계통의 지진거동분석을 위한 실험적 연구)

  • Kim, Sung-Wan;Yun, Da-Woon;Kim, Jae-Bong;Jeon, Bub-Gyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.2
    • /
    • pp.35-42
    • /
    • 2021
  • In this study, a steel frame that realized the second floor of a structure was fabricated in referring to NFPA 13. In addition, a riser pipe system with groove joints was installed, and a seismic simulation test was performed using static cyclic loading. Cyclic loading tests on the maximum allowable side sway of seismic design standards for buildings in Korea were conducted using actuators to analyze the seismic behavior of the riser pipe system and major piping elements due to the deformation of the steel frame structure or the displacement-dominant behavior caused by the relative displacement between the structural members in the event of a seismic load. Moreover, the deformation angle of the riser pipe system was measured using an image measurement system because it is difficult to measure using the conventional sensors.

Analysis of Elastic Wave Based Leakage Detection Technology Using Accelerometers (가속도계를 이용한 탄성파 기반 누수탐지 기술 분석)

  • Choi, Kwangmook;Lee, Hohyun;Shin, Gangwook;Hong, Sungtaek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1231-1240
    • /
    • 2020
  • Water pipes are laid on the ground, making it impossible to visually detect leaks due to aging of pipes, and technology to detect leaks in pipes is mainly used to detect leaks in pipes by detecting leaks. In this paper, two accelerometers were attached to both ends of the constant water piping to calculate the time difference between the acquired data to detect leakage points. The leak test of piping was performed by installing valves at 4.3m, 8.6m, and 12.9m points on piping 17.2m, and changing the development rate of valves to 30% and 70%. Leakage can be detected for pressure drop in piping, which is 30% and 70% open valve. It is very important to detect leakage in the early stage, and it is judged that detection of the initial leak point from the algorithm applied in this paper will be possible.