• Title/Summary/Keyword: 배관리

Search Result 20, Processing Time 0.031 seconds

Discharge Standards of Kitchen-Disposer Wastewater by Treatment Types (디스포저(부엌용 오물분쇄기)-배수 전처리 방식 별 수질기준)

  • Chang, Ho Nam;Jeong, Chang Moon;Kang, Jong Won;Choi, Jin-dal-rae;Park, Young Sook;Ku, Ja-Kong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.19 no.2
    • /
    • pp.55-69
    • /
    • 2011
  • Use of disposer at the kitchens of Korean apartments is inevitable in treating their foodwaste having a water content of more than 80%. Also we have to ensure that this extra disposer-foodwaste BOD loadings be treated properly by installing/operating a pre-treatment system before this wastewater enters public sewer system. However, the degree of BOD removal should not be excessive since a BOD/N ratio higher than 5 is required for removing N/P at a municipal wastewater treatment plant. The removal of BOD/N in the pretreatment system rather than BOD alone can be an alternative solution in solving this problem. The particles separated by sedimentation, screen or packed-bed can be anaerobically digested at apartment sites to generate biogas that can be used for simple digester heating and to generate volatile fatty acids (VFAs) for nitrogen removal. We suggest that Korean government grants a temporary license (say for 5 years) to foodwaste treatment companies in collaboration with apartment construction companies which may do business and develop various kinds of disposer-foodwaste treatment systems in diverse wastewater discharge systems of Korean apartments.

Image Detection System for Leakage Regions of Hydraulic Fluid in Faring Press Machine (단조프레스기의 유압유 누유영역 영상 감지 시스템)

  • Bae, Sung-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.11
    • /
    • pp.1557-1562
    • /
    • 2009
  • In the hydraulic room of a forging press machine, a system which can detect and prevent risks at its early stage is needed because there may be a leakage due to the damage of the connection parts of the piping which can endanger human life and mechanical damage. In this paper, the system to automatically recognize a leakage of hydraulic fluid in terms of using the pan/tilt camera from a remote place is implemented. It finds the bounding boxes which are recognized with object regions in the process of labeling and detects the proper leakage regions of hydraulic fluid with the ratios of width and height of the bounding boxes and compactness of the leakage shape. Also, it performs noise removal and calibration for transition and rotation of image as a preprocessing process. The experimental results show that the proposed system has been verified to detect the leakage regions accurately in various sources of light.

  • PDF

The study of CFD Modelling and numerical analysis for MSW in MBT system (생활폐기물 전처리시스템(MBT)의 동역학적 수치해석 및 모델링에 대한 연구)

  • Lee, Keon joo;Cho, Min tae;Na, Kyung Deok
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.3
    • /
    • pp.77-86
    • /
    • 2010
  • In this study, the model of the indirect wind suction waste sorting machine for characteristics of the screening of waste was studied using computational fluid dynamics and the drag coefficient for the model and the suction wind speed were obtained. The wind separator are developing by installing a cyclone air outlet to the suction blower impeller waste is selective in a way that does not pass the features and characteristics of the inlet pipe of the pressure loss and separation efficiency can have a significant impact on. Using Wind separator for selection of waste in the waste prior research on the aerodynamic properties are essential. For plastic cases, it is reasonable to take the drag coefficient between 0.8 and 1.0, and for cans, compression depending on whether the cans, the drag coefficient is in the range from 0.2 to 0.7. The separation efficiency of waste as change suction speed was the highest efficiency when the suction speed was 25~26 m/s. Shape of the inlet, depending on how the transfer pipe of the duct pressure loss occurs because the inlet velocity changes through the appropriate design standards to allow for continued research is needed.

A Study on The Optimization of Pre-treatment for the Brine Wastewater from the Epoxy-resin Process by the Coagulation and Sedimentation Reactions (에폭시수지 생산 공정에서 발생되는 brine 폐수의 전처리를 위한 응집 및 침전 반응의 최적화 연구)

  • Cho, Wook Sang;Lee, Eun Young;Kang, Seong Wook;Lee, Jang Su;Jin, Su Ik
    • Clean Technology
    • /
    • v.11 no.2
    • /
    • pp.57-67
    • /
    • 2005
  • Epoxy resins are produced by the dehydro condensated reaction with ECH (Epichlorohydrin) and BPA(Bisphenol-A) as raw reactants under sodium hydroxide(NaOH) as a catalyst, and from this reaction, salted water named of brine, which contains ECH derivatives in condition of emulsion as likely as glycidol and polymer resins, is produced as an undesired side product. This brine water is alkaline wastewater and causes process fouling problems by plugging and chemically depositing polymer particles on the surface of inner wall of reactors and pipes, and decreases the biodegradable efficiency in the wastewater process. In this study, the optimization of coagulation and sediment reactions, using inorganic and organic polymer coagulants, were performed to remove the causes occurring the process fouling phenomena. And also, based on this study, the methodologies applicable to the commercial processes including economical analysis were presented.

  • PDF

A Study on Cathodic Protection Rectifier Control of City Gas Pipes using Deep Learning (딥러닝을 활용한 도시가스배관의 전기방식(Cathodic Protection) 정류기 제어에 관한 연구)

  • Hyung-Min Lee;Gun-Tek Lim;Guy-Sun Cho
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.49-56
    • /
    • 2023
  • As AI (Artificial Intelligence)-related technologies are highly developed due to the 4th industrial revolution, cases of applying AI in various fields are increasing. The main reason is that there are practical limits to direct processing and analysis of exponentially increasing data as information and communication technology develops, and the risk of human error can be reduced by applying new technologies. In this study, after collecting the data received from the 'remote potential measurement terminal (T/B, Test Box)' and the output of the 'remote rectifier' at that time, AI was trained. AI learning data was obtained through data augmentation through regression analysis of the initially collected data, and the learning model applied the value-based Q-Learning model among deep reinforcement learning (DRL) algorithms. did The AI that has completed data learning is put into the actual city gas supply area, and based on the received remote T/B data, it is verified that the AI responds appropriately, and through this, AI can be used as a suitable means for electricity management in the future. want to verify.

Leakage Detection Method in Water Pipe using Tree-based Boosting Algorithm (트리 기반 부스팅 알고리듬을 이용한 상수도관 누수 탐지 방법)

  • Jae-Heung Lee;Yunsung Oh;Junhyeok Min
    • Journal of Internet of Things and Convergence
    • /
    • v.10 no.2
    • /
    • pp.17-23
    • /
    • 2024
  • Losses in domestic water supply due to leaks are very large, such as fractures and defects in pipelines. Therefore, preventive measures to prevent water leakage are necessary. We propose the development of a leakage detection sensor utilizing vibration sensors and present an optimal leakage detection algorithm leveraging artificial intelligence. Vibrational sound data acquired from water pipelines undergo a preprocessing stage using FFT (Fast Fourier Transform), followed by leakage classification using an optimized tree-based boosting algorithm. Applying this method to approximately 260,000 experimental data points from various real-world scenarios resulted in a 97% accuracy, a 4% improvement over existing SVM(Support Vector Machine) methods. The processing speed also increased approximately 80 times, confirming its suitability for edge device applications.

Effect of Coexisting Ions on Electrokinetic Injection in Capillary Electrophoresis Analysis (모세관 전기영동 분석에서 계면 동전기 주입에 미치는 공존 이온의 영향)

  • Lee, Kwang-Woo;Jeon, Ji-Young;Lee, Kwang-Pill
    • Analytical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.35-42
    • /
    • 1996
  • A rapid analytical method based on capillary electrophoresis is described for the determination of trace anions in high-purity chemicals which is used to prevent corrosion demage in nuclear power plants. Separations are carried out at 20kV using trimethylsilane-coated fused-silica capillary ($70cm{\times}50$ or $75{\mu}m$ i.d.) with the electrolyte of 5mM Chromate(pH=8). Detection was achieved using on-column indirect photometry at 254nm. The simultaneous analysis of inorganic anions, chloride, nitrate, sulfate, azide and phosphate was performed using methods of hydrodynamic(>1ppm) and / or electrokinetic(<1ppm) injection. The results of studies on the coexisting anions on analyte ions shows that peak responses of analyte in hydrodynamic injection is constant without effect of coexisting anions, but those of analysis in electrokinetic injection is strongly dependant upon the kind of coexisting anions and its ionic mobility. The analyte enrichment rate, hence peak response, is positive relationship with the resistance of the sample solution. Thus, appropriate measures, such as standard addition or internal standard technique, must be used to account for differences in conductance of standard and sample solutions.

  • PDF

Growth Characteristics of Common Ice Plant (Mesembryanthemum crystallinum L.) on Nutrient Solution, Light Intensity and Planting Distance in Closed-type Plant Production System (완전제어형 식물 생산 시스템에서 배양액, 광도 및 재식거리에 따른 Common Ice Plant의 생육 특성)

  • Cha, Mi-Kyung;Park, Kyoung Sub;Cho, Young-Yeol
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.89-94
    • /
    • 2016
  • This study was conducted to determine the optimum nutrient solution, pH, irrigation interval, light intensity and planting density to growth of common ice plant (Mesembryanthemum crystallinum L.) in a closed-type plant production system. Three-band radiation type fluorescent lamps with a 12-h photoperiod were used. Nutrient film technique systems with three layers were used for the plant growth system. Environmental conditions, such as air temperature, relative humidity and $CO_2$ concentration were controlled by an ON/OFF operation. Treatments were comparison of the nutrient solution of Horticultural Experiment Station in Japan (NHES) and the nutrient solution of Jeju National University (NJNU), pH 6.0 and 7.0, irrigation interval 5 min and 10 min, light intensity 90 and $180{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and within-row spacing 10 cm, 15 cm, 20 cm and 25 cm with between-row spacing 15 cm. Optimum macronutrients were composed N 7.65, P 0.65, K 4.0, Ca 1.6 and Mg $1.0mM{\cdot}L^{-1}$. There were no significant interactions between pH 6.0 and 7.0 about shoot fresh weight and shoot dry weight of common ice plant. Irrigation interval 5 min and 10 min was also the same result. Shoot fresh weight and shoot dry weight were highest at $180{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Shoot fresh weight and shoot dry weight were decreased according to increasing the planting density. From the above results, we concluded that optimum nutrient solution, optimum levels of pH, irrigation interval, light intensity and planting density were 6.0-7.0 and 10 min, $180{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ and $15{\times}15cm$, respectively for growth of common ice plant in a closed-type plant production system.

Comparison of Anaerobic Digestion for food wastewater and food waste by HADS Pilot Plant (HADS Pilot Plant를 이용한 음폐수와 음식물쓰레기의 혐기성 소화 비교)

  • Ju, Donghun;Lee, Jungmin;Park, Seongbum;Sung, Hyunje
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.245-245
    • /
    • 2010
  • 우리나라 생활폐기물 중 음식물쓰레기는 가장 많은 부분을 차지하고 있다. 또한, 음식물쓰레기에서 발생되는 음폐수의 발생량은 8,926톤/일에 달하고 있지만, 이 중 극히 일부만이 하수처리장 등에서 병합 처리되고 있고 대부분은 해양 투기되고 있는 실정이다. 이에 본 연구에서는 독일 GBU사로부터 중온/습식/이상 혐기성 소화 기술을 도입하여 HADS Pilot Plant를 설치하였고, 2008년 3월부터 국내 음폐수 및 음식물쓰레기에 적합한 최적의 운전기술을 확보하기 위한 Pilot Test를 실시하였다. 본 실험에 사용된 HADS Pilot Plant는 산발효조($6m^3$), 메탄발효조($50m^3$), 안정화조/가스저장조($40m^3$)그리고 가스 소각기로 구성되어 있다. 그리고 적용 음폐수 및 음식물쓰레기는 경기도 Y군에 위치한 사료화 시설에 반입되는 것을 이용하였는데 음폐수는 평균 TS 13.5%, VS 80%, pH $3.7{\pm}0.2$의 성상을 나타내었다. 이를 이용해 계단식으로 유기물 부하를 증가시키면서 $4kgVS/m^3/d$까지 적용하며 중온 상태에서 혐기성 소화를 실시한 결과, $0.8Nm^3/kgVS_{rem}/d$의 바이오가스 회수 및 85%의 VS 감량이 가능함을 확인하였다. 그리고 음식물쓰레기는 음폐수와 달리 1차 파쇄/선별기 및 배관상에 설치되는 2차 미세파쇄/선별기를 통한 전처리를 실시하였고, 1차 파쇄/선별 후 평균적으로 TS가 17.4%, VS는 81%, pH는 $3.85{\pm}0.2$의 성상을 나타내는 음식물쓰레기를 2차 미세파쇄/선별기를 거쳐 Pilot Plant의 산발효조에 투입하여 중온상태에서 혐기성 소화를 실시하였다. 음폐수 적용시와 마찬가지로 계단식으로 유기물 부하를 증량하면서 $4kgVS/m^3/d$까지 적용하여 운전하였고, 그 결과 약 $0.9{\sim}1.2Nm^3/kgVS_{rem}/d$의 바이오가스 회수와 85~87%의 VS 감량 효율을 확인하였다. 음폐수와 음식물쓰레기의 혐기성 소화 실험 결과, 제거된 VS량을 기준으로 보았을 때, 음식물쓰레기에서 더 많은 바이오가스 발생하였는데 이는 음식물쓰레기에 존재하는 고형물이 미생물들의 서식 공간으로 활용됨에 따라 혐기성 소화 과정에서 일어나는 혼합 발효 및 공영양 대사가 음폐수 대비 좀 더 수월하게 일어날 수 있게 된 데에 따른 결과라고 생각된다. 당사의 HADS Pilot Plant test에서는 계단식의 순차적인 유기물 부하 증량과 총VFA/총 알카리도 비율을 0.3~0.4 수준이하로 유지하며 운전함에 따라 음폐수와 음식물 모두에서 안정적으로 $4kgVS/m^3/d$까지의 유기물 부하 적용이 가능하였다. 또한, 생산된 바이오가스 내 메탄의 함량은 60~65%를 유지하였으며, 메탄발효조의 pH는 별도의 조절이 없이도 운전기간 동안 평균 7.8~7.9 수준을 유지하였다. 이처럼 pH 3.7~3.8의 음폐수 또는 음식물쓰레기의 투입에도 안정적인 완충능력을 보여준 것은 소화조 내에서 기질로부터 분해되어져 나오는 암모니아와 이산화탄소가 강력한 버퍼 시스템을 구축하고 있음에 따른 결과로 사료된다. 그리고 음폐수와 음식물쓰레기의 경우 모두 85%이상의 높은 VS 제거율을 보여주었는데 이는 당사의 HADS Pilot Plant 소화조의 구조가 내통과 외통으로 구분되어져 있음에 따라 plug flow + CSTR의 특징을 가짐에 따른 결과로 판단된다. 상기한 결과를 바탕으로 향후에는 $5kgVS/m^3/d$ 수준의 유기물 부하 적용운전도 계획하고 있다.

  • PDF

Analysis of Ground Subsidence Influencing Factors Using Underground Facility Property Information (지하매설물 속성정보를 활용한 지반함몰 영향인자 분석)

  • Jaemo Kang;Sungyeol Lee;Jinyoung Kim;Myeongsik Kong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.25 no.1
    • /
    • pp.5-11
    • /
    • 2024
  • Ground subsidence mainly occurs in urban areas with high population density, so it is necessary to clearly identify the cause of occurrence and prepare in advance. The main cause of ground subsidence is reported to be the creation of cavities in the ground due to damage to underground pipes, but the property information and influencing factors of underground pipes to predict and prepare for ground subsidence are not properly established. Therefore, in this study, factors showing a significant correlation with the occurrence of ground subsidence were selected among the underground facility property information and a regression equation was proposed through logistic regression analysis. For this purpose, data on underground structures and ground subsidence history information in the target area were collected, and the target area was divided into girds of 100m x 100m in size using QGIS. The underground facility attribute information and ground subsidence history information contained within the gird were extracted. Then, preprocessing was performed to construct a dataset and correlation analysis was performed. As a result, factors excluding the year of sewer pipes and communication pipes and the average depth of communication pipes, heat pipes, and gas pipes were found to have a significant correlation with ground subsidence. In addition, a regression equation for whether ground subsidence occurred in the target area is proposed through logistic regression analysis.