• Title/Summary/Keyword: 방호능력

Search Result 63, Processing Time 0.026 seconds

A Protection Capacity Evaluation of Vessel Protective Structures by Quasi-Static Collision Analysis (준정적 충돌해석을 통한 선박충돌방공호의 방호능력평가)

  • Lee, Gye-Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.6
    • /
    • pp.691-697
    • /
    • 2011
  • In this study, the vessel collision protective structure and the vessel were modeled numerically and the quasi-static collision analysis was performed to evaluate the maximum protection capacity. In the modeling process of protective structure, the nonlinear behaviors of structure and the supporting conditions of ground including pull-out action were considered. In that of collision vessel, the bow of vessel was modeled precisely, because of the nonlinear behaviors were concentrated on it. For the efficient analysis, the mass scaling scheme was applied, also. To evaluate the differences and efficiency, the dynamic analyses were performed for the same model, additionally. Based on the obtained energy dissipation curves of the structure and the vessel, the moment that the collision force affected to the bridge substructures was determined and the maximum allowable collision velocity was evaluated. Because of the energy dissipation bound can be recognized clearly, this scheme can be used efficient in engineering work.

The Development of Electromagnetic pulse Protection Capability in the Main System of a Tank Battalion (전차대대 주요체계의 EMP 방호능력 발전방안에 관한 연구)

  • Choi, Hokab;Han, Jaeduk;Son, Sangwoo;Kim, Sungkon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.623-631
    • /
    • 2020
  • An electromagnetic pulse (EMP) attack on a nuclear weapon or the airlift of an electronic bomb affects weapons systems, information devices, wired and wireless communication equipment, and power supply equipment. It can lead to confusion on the battlefield. The current standards for EMP protection when applied to the military are centered on fixed and mobile facilities and equipment. It is, however, important to study EMP protection for a single tactical unit centered on the weapon system. In this study, EMP protection standards were established for command and control, maneuvering and firepower systems vulnerable to EMPs, focusing on battle tanks with mobility, firepower, and shock force. Also, specific development plans for EMP protection capabilities are proposed, including the shielding and blocking of EMPs. Through the study, the Korean government intends to ensure a unit's command and control under an EMP attack as well as preserve the viability of a unit's personnel and guarantee the conditions for the execution of a mission.

일본 육상자위대의 고기능 전투복과 개인장구

  • Lee, Su-Sik
    • Defense and Technology
    • /
    • no.4 s.242
    • /
    • pp.82-87
    • /
    • 1999
  • 전투원(전투병사) 개인방호체계는 각개병사와 병사들이 전술적 환경에서 사용하기 위해 착용, 소모, 휴대하는 모든것을 포함하는 방호체계들의 시스템이다. 이러한 전투원 개인방호체계의 현대화 노력은 "위력", "지휘 및 통제", "생존성", "유지능력", "기능성"을 극대화하고 전투원 체계들을 디지털 전장에서 통합함으로써 전투상승효과를 달성할 수 있다

  • PDF

A Study on Status Survey for the Improvement of Shelter Facilities for Residents (주민대피시설의 성능개선을 위한 실태조사에 관한 연구)

  • Park, Namkwun;Kang, Shinwook
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.1
    • /
    • pp.91-97
    • /
    • 2014
  • purpose of this study was to conduct status survey on existing shelter facilities for residents and use it as basic material to plan and design improved shelter facilities in the future. As the result, first, although existing shelter facilities are judged to have been designed in consideration only of the protection from high explosive shells, actual protection capability is significantly low against high explosive shells when exit direction and protection capabilities of main entrances were investigated. Second, all the 7 facilities did not have air purifier with filters installed for the air that flows into the inside from outside and since the height of air exhausts and intake pipes in the outside are also close to the earth, there are possibilities that heavy contaminated air can flow into the inside. Third, although some facilities have anti-explosion doors installed, it is impossible to use them as chemical, biological and radiological (CBR) shelter because of improper installation of openings and anti-explosion valves as well as poor plumbing that cannot ensure air-tightness and poor finish of piping penetration.

A Study for the Efficient Improvement Measures of Military EMP Protection Ability (국방 EMP 방호능력의 효율적 개선을 위한 방안 연구)

  • Jung, Seunghoon;An, Jae-Choon;Hwang, Yeung-Kyu;Jung, Hyun-Ju;Shin, Yongtae
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.1
    • /
    • pp.219-227
    • /
    • 2017
  • Current military command information system uses electronic equipment a lot on which semiconductor chip is attached. It seems its' importance will increase more with latest information communication technology developing. Electronic equipment which uses electricity contains regular tolerance to high output electric signal. And EMC specification is the standardized of this electronic equipment's tolerance. On the other hand, the Institute of Atomic Energy Research has ever declared that high output electromagnetic pulse(EMP) will be broken out within the radius of 170Km when 10kt nuclear explosion occurs at an altitude of 40Km above Seoul. Then, the region suffer from the damage of most electronic equipments. Therefore, the norm to protect the influences in that case is defined by EMP protection specification. Most common electronic equipments meet the EMC norm, but there is no way to check whether they meet the EMP norm or not. That is because it is difficult to check whether they meet EMP protection norm and is on the matter of cost. Except inevitable cases, there is no review of checking whether they meet the norm or not. Considering the above, in this research, we speculate about the measures to improve military EMP protection ability by analyzing the EMC-EMP correlation and checking the EMP protection ability of general electronic equipment through the analysis.

Ultimate capacity evaluation of Vessel protective structure by quasi-static analysis (의사정적해석을 통한 선박충돌방호공의 극한성능평가)

  • Lee, Gye-Hee;Hong, Kwan-Young;Kim, Se-Jeong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.731-734
    • /
    • 2011
  • 본 연구에서는 강재로 구성된 선박충돌방호공의 최대방호능력을 산정하기 위하여 선박과 충돌방호공을 모델링하고 충돌거동을 해석하였다. 이러한 비선형충돌해석은 매우 큰 요소망과 고도의 비선형성을 려해야하기 때문에 이의 해석비용이 일반적인 해석에 비하여 매우 크므로 해석의 경제성을 확보하기 의사정적해석방법을 이용하여 해석을 수행하였다. 이 과정에서 효율적인 해석을 위한 수치 해석기법이 추가되었다. 해석결과 얻어진 선박과 방호공의 에너지소산곡선을 바탕으로 충돌선박이 교량하부구조에 도달하는 시점을 추정하고 이를 바탕으로 대상선박의 최대충돌속도를 산정하였다.

  • PDF

A Study on the Method for Judging the EMP Protection Plan and Required Level through Decision Making (의사결정론을 통한 EMP 방호대책 및 수준 판단방안 제시에 관한 연구)

  • Kim, Kuk-Joo;Park, Sang-Woo;Baek, Jang-Woon;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.2
    • /
    • pp.193-200
    • /
    • 2019
  • In the context of increasing threats of EMP by neighboring countries in the security situation on the Korean peninsula, EMP protection facilities are a very important means of ensuring military operational capability. These EMP protection facilities should be constructed by comprehensively judging various factors about operation units. However, Defense Military Facilities Criteria and National Technical Guideline for EMP protection require at least 80dB shielding effectiveness without considering other options. In this study, we use objective and statistical methods to refine the consideration of the required EMP protection level based on the opinions of the experts. To do this, the Delphi technique is used for this study, and the survey was conducted from 53 experts related to EMP protection standard in the military and civilian sectors. The first questionnaire investigated the appropriate level of EMP protection, and the second questionnaire analyzed the factors considered in establishing EMP protection level. As a result of the factor analysis on the opinions of the experts, it was concluded that the EMP protection requirement level should be determined by variables of METT + TC.

Evaluation of Protective Performance of Fiber Reinforced Concrete T-Wall (섬유보강 콘크리트 방호벽의 방호성능 향상 검토)

  • Lee, In-Cheol;Kim, Hong-Seop;Nam, Jeong-Soo;Kim, Suk-Bong;Kim, Gyu-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.5
    • /
    • pp.465-473
    • /
    • 2013
  • Concrete is an outstanding material in terms of its impact and blast resistance performance. However, there a limitation of concrete is its risk of collapse due to the brittle failure and spalling. Increasing the thickness of members was used as a method to enhance the protective performance of concrete, despite the resulting inefficient space. To solve this problem, different types of fiber reinforced concrete were developed. Recently, another type of fiber reinforced concrete is also being developed and applied as a material that offers protection against impacts and blasts by increasing the flexural toughness of concrete. In this study, the test was conducted to evaluate the impact resistance performance of fiber reinforced concrete and mortar according to impact of high-velocity projectile. A concrete T-wall was also tested to evaluate its protective performance from fragment by 155mm-thick artillery shell. The test results revealed that improving flexural strength through fiber reinforcement inhibited cracks and spalling of rear, and spalling of front by high-velocity impact. As such, it is expected to improve the protective performance of the T-wall and reduce the thickness of the member.

물리흡착하는 화학작용제에 대한 방독면 정화통의 성능 연구

  • Im, Jong-Seon;Kim, Cheol-Seong
    • Defense and Technology
    • /
    • no.2 s.240
    • /
    • pp.68-77
    • /
    • 1999
  • 우리 군이 사용하고 있는 K1 방독면은 모든 종류의 화학작용제에 대한 방호력이 뛰어나며 생존성을 보장할 수 있는 화학방호 장비로 병사들은 화학전에 대해 막연한 두려움을 가질 필요가 없으며 자신감을 가져야 할 것이다. 또한 언제든지 화학무기에 대응할 수 있도록 평시에 많은 훈련을 쌓아서 전시에 언제든지 자신감을 가지고 작전을 수행할 수 있는 능력을 구비해야 할 것이다

  • PDF

Radiation Protection Effects of Schizonepeta Tenuifolia Water Extracts by Gender in SD Rats (SD rats의 성별에 따른 형개 열수추출물의 방사선 방호효과)

  • Lee, Ji-Eun;Kim, Jang-Oh;Lee, Yoon-Ji;Jeon, Chan-hee;Heo, Sung-Hoe;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.313-320
    • /
    • 2021
  • This study evaluates the radiation protection effects of Schizonepeta tenuifolia water extract on white rat by gender. Schizonepeta tenuifolia contains polyphenol and flavonoid, which are typical substances that remove free radical. Thus, to determine the effectiveness of radiation protection, the Schizonepeta tenuifolia water extract was administered to Sparaqu-Dawely (SD) rat males and females for two weeks, followed by hematological analysis, analysis of changes in the length of the small intestine villi length, and SOD activity evaluation. The male rat in ST+IR group showed a slightly greater recovery of platelets than the IR group. The ST+IR group also showed a higher platelet recovery capability than the IR group. lymphocyte showed that male and female rat ST+IR groups have higher resilience than IR groups likewise platelet. After irradiation, the villi length of the male rat and female rat decreased less in ST+IR group than in the IR group, indicating that the villi length of all genders was less damaged. This result confirmed that the Schizonepeta tenuifolia water extract had a radiation protection effect.