• Title/Summary/Keyword: 방향틀림

Search Result 180, Processing Time 0.028 seconds

Analysis of the Influence of Track Alignment on Ride Comfort and Safety of KTX (방향틀림이 KTX 주행거동에 미치는 영향 분석)

  • Choi, Il-Yoon;Um, Ju-Hwan;Kim, Man-Cheol
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.2
    • /
    • pp.110-116
    • /
    • 2013
  • Track irregularities is one of the key factors influencing the running behavior of trains. In order to ensure safety and ride comfort of train, the criteria for track irregularities should be adequately established regarding vehicle velocity, vehicle characteristics, characteristics of the track recording car, and measurement interval. Also, track maintenance should be carried out thoroughly according to the criteria for managing track irregularities. Numerical analysis was conducted to investigate the influence of track alignment on the running behavior of Korean high speed train(KTX). Various wavelengths and amplitudes of lateral alignment were considered as parameters for this study using the Vampire program, a vehicle dynamics modeling package in railway environment. Derailment, lateral load, bogie acceleration and body acceleration of numerical analysis results due to alignment were investigated. Finally, the influence of the alignment on safety and ride comfort for the KTX was evaluated. This study indicates that alignment irregularities have significant impacts on running safety, and that the criteria used to manage alignment irregularities should be restrictive to ensure the running safety of the KTX.

Effect of Cable Tension Changes on Track Irregularity of Railway Ballasted Track on Railway Steel Composite Bridge (케이블 장력변화가 강철도 복합교량 상 자갈궤도의 궤도틀림에 미치는 영향)

  • Jung-Youl Choi;Soo-Jae Lee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.633-638
    • /
    • 2023
  • In this study, the effect of the change in cable tension on the track irregularity of railway ballasted track on a railway steel composite bridge was analyzed. As a result of comparing design and analysis results for cable tension, a difference of less than 3% was found, and analysis modeling was analyzed to reflect the design conditions well. In addition, the adequacy of the analysis modeling was demonstrated by comparing the field measurement results with the analysed cable tension. By considering the change in cable tension as a variable, the track irregularity of the railway steel composite bridge was analyzed. As a result of the analysis, it was analyzed that the total and one-sided cable tension change had a direct effect on the vertical irregularity among the track irregularity items. In addition, it was found that the change in track irregularity occurred in the section close to the cable position. It was analyzed that the change in cable tension had a more direct effect on track irregularity that had a direct correlation with the vertical direction rather than the lateral direction.

Fabrication and Evaluation of Piezoelectric Torsional Transducers (압전 비틀림 파동 변환기 제작 및 평가)

  • Kwon, Oh-Soo;Kim, Jin-Oh
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.4
    • /
    • pp.434-438
    • /
    • 2001
  • Piezoelectric torsional transducers have been fabricated to generate torsional waves in a rod. The principle of generating torsional wane is based on the use of the circumferential shear motion derived by axial voltage exerted on the piezoelectric disk poled in the circumferential direction. The natural frequency or the piezoelctric torsional dish has been reduced by fabricating Langevin-type torsional transducers. The natural frequecies of the fabricated transducers have been measured and have shown good agreement with the characteristics predicted by analysis.

  • PDF

Development of Submersible Axial Pump for Wastewater (폐수 처리용 수중 축류 펌프 개발)

  • Yun, Jeong-Eui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.2
    • /
    • pp.149-154
    • /
    • 2013
  • This study was performed to develop a high efficiency submersible axial pump for concentration wastewater treatment. To do this, we simulated the effect of some parameters such as the axial twist angle of a blade(${\beta}$), the radial twist angle of a blade(${\alpha}$) and the length of a blade (l) on pump efficiency using commercial code, ANSYS CFX and BladeGen. The results showed that the axial twist angle of a blade(${\beta}$) was the most sensible parameter on the pump efficiency. And the pump efficiency had a maximum at ${\beta}=20^{\circ}$, ${\alpha}=110^{\circ}$ and l=240 mm.

Evaluation of Limit Loads for Circumferentially Cracked Pipes Under Combined Loadings (원주방향 표면 결함이 존재하는 배관에 가해지는 비틀림을 포함한 복합하중에 대한 한계하중식 제시)

  • Ryu, Ho-Wan;Han, Jae-Jun;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.5
    • /
    • pp.453-460
    • /
    • 2015
  • Since the Fukushima nuclear accident, several researchers are extensively studying the effect of torsion on the piping systems In nuclear power plants. Piping installations in power plants with a circumferential crack can be operated under combined loading conditions such as bending and torsion. ASME Code provides flaw evaluations for fully plastic fractures using limit load criteria for the structural integrity of the cracked pipes. According to the recent version of Code, combined loadings are provided only for the membrane and bending. Even though actual operating conditions have torsion loading, the methodology for evaluating torsion load is not established. This paper provides the results of limit load analyses by using finite element models for circumferentially cracked pipes under pure bending, pure torsion, and combined bending and torsion with tension. Theoretical limit load solutions based on net-section fully plastic criteria are suggested and verified with the results of finite element analyses.

Evaluation of Convective Heat Transfer Performance of Twist-Vane Spacer Grid in Rod Bundle Flow (봉다발 유동 내 비틀림 혼합날개 지지격자의 대류열전달 성능 평가)

  • Lee, Chi Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.157-164
    • /
    • 2016
  • The performance of convective heat transfer in rod bundle flow was experimentally evaluated using a twist-vane spacer grid. A $4{\times}4$ square-arrayed rod bundle was prepared as the test section, with a pitch-to-diameter ratio(P/D) of ~1.35. To check the convective heat transfer performance, the circumferential and longitudinal variations in rod-wall temperatures were measured downstream of the twist-vane spacer grid. In the circumferential measurements, the rod-wall temperature toward the twist-vane tip showed the lowest value, which might be due to the deflected water flow caused by the twist-vane. On the other hand, the wall temperature of the longitudinal measurements near the twist-vane spacer grid decreased dramatically, which implies that the convective heat transfer performance was enhanced. A heat transfer enhancement of ~35 % was achieved near downstream of the twist-vane spacer grid, as compared with the upstream value. Based on the present experimental data, a correlation for predicting the heat transfer performance of a twist-vane spacer grid was proposed.

Torsional Strength and Failure Modes of Reinforced Concrete Beams Subjected to Pure Torsion (순수비틀림을 받는 철근콘크리트 보의 비틀림 강도와 파괴모드)

  • Lee, Jung-Yoon;Kim, Sang-Woo;Kim, Ji-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.4
    • /
    • pp.503-511
    • /
    • 2008
  • This paper presents the results of an analytical and experimental study on the performance of reinforced concrete beams subjected to pure torsion. The main parameters of the experimental tests were amount of torsional reinforcement and the ratio of the transverse torsional reinforcement to the longitudinal torsional reinforcement. The test results indicated that the maximum amount of torsional reinforcement required in ACI 318-05 code underestimated almost twice as much as the observed maximum amount of torsional reinforcement. Comparisons between the tested and calculated torsional behaviors of the 102 beams showed that the torsional failure modes of ACI 318-05 code disagreed with the observed failure modes. In addition, the torsion provisions in ACI 318-05 code overestimate the torsional strength of the RC beams in which relatively large amount of torsional reinforcement were reinforced, while underestimate for the beams with small amount of torsional reinforcement. This discrepancy between the theoretical ultimate torsional strength as given by the ACI 318-05 code and the experimental one can be due to neglecting the tension stiffening effect and the contribution of the torsional strength by concrete.

Particle migration in Torsional Flow of a Viscoelastic Solution (점탄성 용액의 비틀림 흐름에서의 입자의 이동)

  • 최형진
    • The Korean Journal of Rheology
    • /
    • v.3 no.1
    • /
    • pp.13-21
    • /
    • 1991
  • 본연구에서는 단단한 구형 입자가 적은 변형속도에서 2차 유체로 간주될 수 있는 점탄성 용액의 disc-plate (비틀림)흐름에 놓였을 때의 측면 이동속도에 관하여 분석하였다. 이론적 계산을 통해 비틀림 유체 흐름에서 입자는 항상 중심쪽으로 이동하고 안쪽으로의 이 동속도의 크기는 유체의 성질과 흐름의 형태의 함수라는 것을 발견하였으며 이것은 2차 유 체에서 입자는 높은 전단속도 영역에서 낮은 전단속도 영역으로 이동된다는 예측과 일치한 다는 것을 알 수 있었다. 그러나 2차 유체 모델로 부터의 이결과는 이전연구자들에 의해 관 찰된 비틀림 유체 흐름에서의 바깥방향으로의 입자의 이동은 설명하지 못하였다.

  • PDF

Ultrasonic Transducer Design for the Axial Flaw Detection of Dissimilar Metal Weld (이종금속 용접부 축방향 결함 검출을 위한 초음파 탐촉자 설계)

  • Yoon, Byung-Sik;Kim, Yong-Sik;Yang, Seung-Han
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.536-542
    • /
    • 2011
  • Dissimilar metal welds in nuclear power plant are known as very susceptible to PWSCC flaws, and periodically inspected by the qualified inspector and qualified procedure during in-service inspection period. According to field survey data, the majority of their DMWs are located on tapered nozzle or adjacent to a tapered component. These types of configurations restrict examination access and also limit examination volume coverage. Additionally, circumferential scan for axially oriented flaw is very difficult to detect located on tapered surface because the transducer can't receive flaw response from reflector for miss-orientation. To overcome this miss-orientation, it is necessary adapt skewed ultrasonic transducer accomodate tapered surface. The skewed refracted longitudinal ultrasonic transducer designed by modeling and manufactured from the modelling result for axial flaw detection. Experimental results showed that the skewed refracted longitudinal ultrasonic transducer get higher flaw response than non-skewed refracted longitudinal ultrasonic transducer.

The Effect of Fiber Volume Fraction Non-uniformity through Thickness Direction on the Torsional Buckling Load of Cylindrical Composite Lattice Structure (두께방향 섬유체적비 불균일이 원통형 복합재 격자 구조의 비틀림 좌굴 하중에 미치는 영향)

  • Min-Hyeok Jeon;Hyun-Jun Cho;Yeon-Ju Kim;Mi-Yeon Lee;In-Gul Kim
    • Composites Research
    • /
    • v.36 no.2
    • /
    • pp.80-85
    • /
    • 2023
  • A cylindrical composite lattice structure is manufactured by filament winding. The distribution of nonuniform fiber volume fraction induced by the manufacturing process can be observed. The stiffness and buckling characteristics can be influenced by non-uniform fiber volume fraction. In this paper, the effect of non-uniform fiber volume fraction through thickness direction on the torsional buckling load of the cylindrical composite lattice structure was examined. The stiffness variation induced by the non-uniform fiber volume fraction was applied to the finite element model, and buckling analysis was performed. The variations of buckling load with variations of fiber volume fraction were compared. The non-uniform fiber volume fraction reduced the torsional buckling load of the composite lattice structure.