• Title/Summary/Keyword: 방하중

Search Result 56, Processing Time 0.023 seconds

Development and Application of Lattice Shear Reinforcement for Flat Plate Slab-column Connection (래티스를 이용한 철근콘크리트 무량판 구조의 슬래브-기둥 접합부 전단보강 공법 개발)

  • Kang, Su-Min;Park, Sung-Woo;Bang, Joong-Seok;Lee, Do-Bum;Kwon, Chul-Hwan;Park, Hong-Gun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.5
    • /
    • pp.482-490
    • /
    • 2013
  • Although the flat plate system is an efficient structural type due to the simplicity of its construction, the low story height, and the various plan design, the slab-column connections are vulnerable to punching shear failure from gravity load and eccentric shear failure from lateral load. To prevent the structure collapse, various construction methods of slab-column connection reinforcement are developed but none of these satisfies all of structural performance, economics, and constructability. This paper presents the reinforcement of slab-column connection with lattice bars. The structural performance is confirmed with the interior slab-column connection tests subjected to cyclic loading, and the economic feasibility is demonstrated from the structural design under the same condition with lattice bars, stud rails, and stirrups.

The Structural Economical Efficiency Evaluation of Partially Restrained Composite CFT Column-to-Beam Connection (합성반강접 CFT기둥-보 접합부 구조의 경제성 평가)

  • Kim, Sun-Hee;Bang, Jung-Seok;Park, Young-Wook;Choi, Sung-Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.1
    • /
    • pp.109-117
    • /
    • 2012
  • This study seeks to devise a design application for a beam structure with partially restrained composite connection to a CFT column. A cost-efficient and stable component is applied by adjusting the stiffness ratio of the column connection through partially restrained composite connection. Based on a review of the structure's stability, it was confirmed that in the case of a low-rise building as a moment frame, resistance without bracing is feasible because stiffness increased by virtue of the partial restrained composite connection by composite action. In the case of a high-rise building, lateral resistance load of moment frame was approximately 10% when proper partial restrained rate was at around 60%. With considerations related to economic efficiency, the partial restriction effect of the beam component was significantly activated by the uniform load, but that of the beam activated by concentrated load was not significantly indicative. The analysis indicated that 60% partial restrained girder at the connection was the most economical in the case of uniform load. It also showed that end moments can be reduced by approximately 25%.

Performance Evaluation System for Construction Environment of the Unified Waterproofing-Root Resistance Membrane layer of the Green Roof System (인공지반 녹화용 방수방근 복합공법의 시공환경을 고려한 성능평가 시스템 연구)

  • Park, Chang-Hwa;Oh, Sang-Keun;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.189-199
    • /
    • 2011
  • Installation of a proper root barrier in a green roof system is very important in order to protect the concrete slab of roof and the root penetration in the waterproofing layer. To select the proper root barrier materials and methods, it is necessary to understand the environmental conditions affecting the waterproofing-root barrier system in green roof construction site. Therefore, we suggested as the environmental performance indexes four kinds of performance requirements; root penetration, chemical attack by chemical agent or fertilizer, load impact by soil depth and size of plant, and water pressure. The related four test methods were suggested for the inspection of these performance indexes. In this research, we could suggest for kinds of test methods as standard test methods to evaluate the environmental performance of waterproofing-root barrier for greening roof system.

Accuracy Analysis of Close-Range Digital Photogrammetry for Measuring Displacement about Loading to Structure (하중에 따른 구조물 변위계측을 위한 근접수치사진측량의 정확도 분석)

  • Choi, Hyun;Ahn, Chang Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4D
    • /
    • pp.545-553
    • /
    • 2009
  • This paper describes the result of study on measurement of displacement of structure by means of non-contacting method, close-range digital photogrammetry using digital camera. To apply close-range digital photogrammetry to displacement measurement of structure, correction of lens distortion that interferes geometrical analysis has been carried out and then measuring displacement was performed on load regulated-rahmen. For enhanced applicability of displacement measurement, MIDAS which is a structural analysis program was used for modeling and the result was taken from comparative analysis. As a result of the study, it is showed that close-range digital photogrammetry could supplement several weaknesses of LVDT and cable displacement meter and, especially, economy in the perspective of measuring time could be realized. Close-range digital photogrammetry using digital camera can be applied to the area where requires visual analysis such as 3D modeling of structure, profile replication of measurement of structure as well as measurement of displacement of structure.

Finite Element Analysis of Stress Distribution on Telescopic System for Mandibular Implant Supported Overdenture (이중관 구조 하악 임플랜트 피개의치의 응력 분포에 관한 유한요소법적 분석)

  • Oh, Jung-Ran;Woo, Yi-Hyung;Lee, Sung-Bok;Bak, Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.359-371
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the stress distribution in mandibular implant overdentures with telescopic crowns compared to bar attachment. Material and methods: Three-dimensional finite element models consisting of the mandibular bone, 4 implants, and primary bar-splinted superstructure or secondary splinted superstructure with telescopic crowns were created. Vertical and oblique loads were directed onto the occlusal areas of the superstructures to simulate the maximal intercuspal contacts and working contacts such as group function occlusion. Maximum stress and stress distribution were analysed in mandibular bone, implant abutments, and superstructures. Results: 1. In comparison of von Mises stress on mandibular bone, telescopic overdenture had a little lower stress values in vertical load and working side load except oblique load. In the mandible, the telescopic overdenture distributed more uniform stress than the bar overdenture. 2. In comparison of von Mises stress on implant abutments, telescopic overdenture had much lower stress values in all load conditions. In implant abutments, the telescopic overdenture distributed stress similar to the bar overdenture. Stress was concentrated on the distal surfaces of the posterior implant abutments in both mandibular overdentures. 3. In comparison of von Mises stress on superstructures, the telescopic overdenture had much more stress values in all load conditions. However, the telescopic overdenture distributed more uniform stress on superstructure than the bar overdenture. In the bar overdenture, stress was concentrated on each cental area of bar structures and connected area between implant abutments and bar structures. Conclusion: In the results of this study, the telescopic overdenture had lower stress values than the bar overdenture in mandibular bone and implant abutments, but more stress values in superstructures. However, if optimal material was selected in making superstructures, the telescopic overdenture was compared to the bar overdenture in stress distribution.

An Analytical Study of Vibrating Considering Soil-Structure Interactions (지반-구조물 상호작용을 고려한 진동기계기초의 해석법 연구)

  • Lee, In-Mo;Lee, Seok-Won;Park, Jong-Gwan
    • Geotechnical Engineering
    • /
    • v.7 no.3
    • /
    • pp.5-20
    • /
    • 1991
  • 동하중을 받는 진동기계기초의 동적해석을 수행하기 위해서는 지반의 임피던스함수의 적절한 산 출이 필수적이며, 회전기계 -기초 -지반의 상호작용이 고려된 동적해석이 요구된다. 이제까지 지 반의 임퍼던스함수는 주로 원형기초에 한하여 제시되어 왔으나, 기초의 형상은 실제로 지반의 임퍼 던스함수에 중요한 역할을 한다. 그러므로 본 연구에서는 여러가지 형상 및 매립된 기초에 적용할 수 있는 임퍼던스함수를 제시하였다. 그리고, 제시된 임퍼던스함수를 바탕으로, 회전기계 -기초- 지반의 상호작용이 고려된 동적해석을 수행할 수 있는 프로그램을 개발하였으며, 개발된 프로그램 을 이용하여 예제해석을 통하여 각종 임피던스함수의 적용에 따른 기계기초의 응답을 비교 검토하였다. 본 연구의 주된 결론은 다음과 같이 요약할 수 있다. 1) 주파수독립 임퍼던스함수와 주파수종속 임피던스함수를 이용한 결과를 비교해 볼 때,수평방 향과 회전방향에 대해서는 동적응답이 커다란 차이를 보이지 않으나, 연직방향 운동에 대해서는 상 당한 차이를 보인다. 2) 표면기초와 매립기초를 비교해 본 결과, 매립기초에 있어서 수평방향과 회전방향에 있어서는 동적응답이 거의 일정한 간에 도달하므로 기초가 어느 정도 매립된다면 안전측에 들어간다고 볼 수 있다. 그러나, 연직방향에 있어서는 매립여부에 따라 상당한 차이를 보인다.

  • PDF

Comparative Study for Pollutant Transport and Diffusion Model (오염물 이송 및 확산 거동 해석모형의 특성비교연구)

  • Jung, Sung-Tae;Lyu, Si-Wan;Kim, Young-Do;Seo, Il-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1407-1411
    • /
    • 2007
  • 현재까지 우리나라에서 주로 사용되고 있는 2차원 흐름 해석모형은 미연방 도로국(U.S. Federal Highway Administration)과 연계하여 Brigham Young University에서 개발된 SMS(Surface-Water Modeling System) 모형이다. SMS모형 중 이송 확산 모형으로는 RMA-4가 포함되나 이 모형은 최신 수치기법을 반영하지 못하는 등의 문제점들로 인해 실제 물리적 현상 모의에 있어서 한계를 가지고 있다. 따라서 물리적 현상에 대한 적절한 모의를 위한 개선과정을 통하여 RAM4가 개발되었다. 본 연구에서는 현장실측 자료를 바탕으로 RMA-4와의 모의결과 비교를 통하여 오염 확산 해석모형인 RAM4의 적용성을 검증하고자 하였다. RAM4와 RMA-4 모의에 있어서 격자구성과 경계조건은 동일하게 설정하였으며, 유량조건은 평수량과 갈수량으로 선정하였다. 각각의 유량시 수위조건이 틀려지므로 각 유량조건에 대한 격자구성을 달리하였다. 모의구간은 낙동강 본류의 수산대교에서 삼랑진 철교까지의 약 13km 구간을 대상으로 하였다. 모의 구간내에는 밀양-하남 하수처리장이 상류 좌안측에 위치하고 있고, 만곡, 단면의 축소 및 확대, 하중도, 합류 등의 지형학적 특징들이 비교적 짧은 구간에 나타나고 있어 모형의 검증에 적합하다고 판단된다.

  • PDF

Thinning Effect Due to Bentonite Migration on Performance of GCL (벤토나이트 유실로 인한 협착이 GCL 거동에 미치는 영향)

  • Choi, Hangseok;Lee, Chulho;Stark, Timothy D.
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.4
    • /
    • pp.49-58
    • /
    • 2006
  • Recently, geosynthetic clay liners (GCLs) have increasingly been used to replace compacted clay liners (CCLs) in composite liner systems. Since the introduction of GCLs to waste containment facilities, one of the major concerns about their use has been the hydraulic equivalency to CCLs as required by regulations. Laboratory test results and more recently field observations show that the thickness, or mass per unit area, of hydrated bentonite in a GCL can decrease under normal stress, especially around zones of stress concentration or nonuniform stresses, such as a rock or roughness in the subgrade, a leachate sump, or wrinkles in an overlying geomembrane. This paper presents field case histories that confirm the laboratory observations of bentonite migration and the effect of bentonite migration on hydraulic equivalency and contaminant transport through a GCL.

  • PDF

Mechanical Properties and Structural Analyses for the Corrugated 3 Layered Sandwich Panels (코로게이트 3층 샌드위치 패널 구조체 물성 및 구조해석)

  • Yun, Su-Jin;Heo, Yeup;Gil, Hyun-Young;Park, Dong-Chang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.5
    • /
    • pp.75-89
    • /
    • 2019
  • In the present work, structural analyses for light weight corrugate 3 layered sandwich panels are carried out. The mechanical properties of the sandwich panels are obtained using the modified analytical closed form based on a corrugated panel deformation and the homogenization scheme of an uniaxial composite. Subsequently, the mechanical properties estimated by the two aforementioned methods were employed for the numerical analyses for the corrugated sandwich panels under the specifically loading conditions, and a comparison between two methods was also made.

Performance Estimation of Hexagonal Rockfall Protection Net by Numerical Analysis (수치해석을 이용한 육각 낙석방지망의 성능 평가)

  • Oh, Sewook;Park, Soobeom;Kwon, Youngcheul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.11
    • /
    • pp.53-59
    • /
    • 2014
  • It has been generally recognized that the conventional rockfall protection nets have several problems to actual field application in the aspect of shock absorption, lack of pullout bearing capacities, and net damages. Because of the recognition, authors have tried to develop a new rockfall protection system consisted of shock absorption parts and hexagonal net configuration. In the previous research by the authors, the performance of the newly developed rockfall protection system has been investigated through the laboratory tests and the full-scale testing. In this study, subsequently, numerical analysis program is organized to make a confirmation of the structural stability and performance. For the correct design procedure of the hexagonal net system, it is essential to understand the various mechanical behavior of the entire system. It is also important to be reproduced the systematic characteristics of the system acquired by laboratory and full-scale testing by numerical analysis in order to carry out the numerical experiment to understand various mechanical behavior of the system. As a conclusion, the hexagonal net has better performance in mechanical and physical behavior compared with that of the rectangular net. Furthermore, due to the hexagonal net shows a good performance in aspect of the load distribution, it gives a good alternative in long-term management of the rockfall protection net.