• 제목/요약/키워드: 방폭성능

검색결과 48건 처리시간 0.024초

섬유조합 및 혼입율 변화에 따른 HPFRCC의 방폭성능 (The Explosion-proof Performance of HPFRCC According to Fiber Combination and Mixing Ratio)

  • 이제현;이종태;정웅선;조성준;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.88-89
    • /
    • 2017
  • Due to the increase in the usage of explosive materials and terrorism, the interest towards the superior explosion protective HPFRCC has risen. In existing research, the optimum ratio for solving the problematic problems such as the optimum fiber incorporation rate and the self-shrinkage crack of HPFRCC had been derived. However, there had been few or even no research upon how effective HPFRCC would perform protective explosion-proof in actual explosion. Therefore, this research compared the explosion-proof performance of HPFRCC according to fiber commination and mixing ratio. As a result, the combination of steel fiber and organic fiber showed excellent flow and strength, and it also improved the explosion resistance.

  • PDF

방폭형 적외선 가연성가스 누출검지기 개발 및 정확도 향상 연구 (A Study on the Development and Accuracy Improvement of an IR Combustible Gas Leak Detector with Explosion Proof)

  • 박규태;유근준;조영도;권정락;안상국;김희식
    • 한국가스학회지
    • /
    • 제18권3호
    • /
    • pp.1-12
    • /
    • 2014
  • 본 논문에서는 적외선센서를 이용하여 방폭형 휴대용 가연성가스 누출검지기를 개발하고 아울러 가스의 농도를 측정하는 정확도를 향상시키는 알고리즘을 제안하였다. 국내최초로 내압 및 본질안전방폭규격(Ex d ib) 적용하여 적외선 가스누출검지기는 개발하였으며, 선형회귀 방정식과 2차 라그랑지(Lagrange) 보간 다항식(interpolation polynomial)을 사용하여 측정정확도를 개선하였다. 아울러 본 연구에서는 현장검사원들의 요구사항을 조사하여 현장에 부합하도록 성능을 향상시키고, 편의기능을 추가하였다. 본 연구에서 개발한 가스누출검지기와 타사의 검지기를 비교하기 위하여 한국가스안전공사에서 제조한 표준가스 8종을 가지고 측정시험을 실시하였다. 본 연구에서 개발한 가스누출검지기의 검지 정확도가 우수함을 실험결과를 통하여 증명하였다.

주민대피시설의 성능개선을 위한 실태조사에 관한 연구 (A Study on Status Survey for the Improvement of Shelter Facilities for Residents)

  • Park, Namkwun;Kang, Shinwook
    • 한국재난정보학회 논문집
    • /
    • 제10권1호
    • /
    • pp.91-97
    • /
    • 2014
  • 본 연구는 기존 설치된 주민대피시설의 실태조사를 통해 주민대피시설의 계획 및 설계에 필요한 기초자료로서의 활용을 목적으로 진행되었다. 그 결과, 첫째, 주민대피시설이 고폭탄 위주의 방호만을 고려하여 설계된 것으로 판단되나, 시설물의 출구방향, 주출입구 방호능력 등을 살펴보았을 때 실제 고폭탄에 대한 방호능력은 상당히 떨어지는 것으로 판단된다. 둘째, 전체 7개 시설은 외부에서 내부로 유입되는 공기에 대한 공기여과청정기가 설치되어 있지 않으며, 외부에 설치된 흡 배기구의 높이도 지상과 근접하게 위치하고 있어 공기보다 무거운 오염공기의 내부 유입을 발생 시킬 수 있다. 셋째, 일부시설은 방폭문이 설치되어 있으나 개구부, 방폭밸브의 역방향 등의 적절하지 못한 설치와 배관 배선의 관통부 마감상태로 인해 정상적인 방폭문의 기능유지 및 기밀성 확보는 어려울 것으로 판단된다.

반도체·FPD 제조설비와 클린룸의 RISK 최소화를 위한 폭발위험장소 설정 모델링에 관한 연구 (A Study of Explosion Hazard Proof Modeling for Risk Minimization to Semiconductor & FPD Manufature Equipment and Clean Room)

  • 노현석;우인성;황명환;우정환
    • 한국가스학회지
    • /
    • 제22권1호
    • /
    • pp.78-85
    • /
    • 2018
  • 본 연구를 통하여 반도체 FPD 제조설비 및 클린룸에 관련한 설비의 위험성분석과 그에 대한 근원적인 안전대책을 연구하고, 설비 및 환경의 특수성을 고려한 방폭 설계 모델링화를 검토하여 관련 설비의 설계 및 제작에 기술적인 기준과 근거로 활용하고자 하며, 아래와 같은 성과로서 향후 반도체 FPD 산업의 기술적 기준 수립 및 관련 산업에 기여할 것으로 생각한다. 1) 관련 국제 기술규격과 법령, 설비의 특성을 반영한 FAB 장비의 최적화된 폭발위험장소의 모델링 도출 2) FAB 장비 및 클린 룸의 특성을 고려한 위험설비의 안전성 확보 (Fool-Proof와 Fail Safe)를 위한 안전시스템 구축방안과 안전기준 및 대책 도출 3) 향후 FAB 장비의 방폭 설계에 대한 가장 효율적인 기준 적용을 통한 신규 FAB 장비의 방폭 성능의 유연성 확보하고 수립된 안전기준을 통한 설비와 안전시스템의 신뢰성 검증 절차 운영을 위한 "안전인증제도"의 자율적 향상화.

고에너지흡수 신소재 적용 해양플랜트 파형 방폭벽의 폭발 저항 성능 (Explosion Resistance Performance of Corrugated Blast Walls for Offshore Structures made of High Energy Absorbing Materials)

  • 노명현;박규식;이재익
    • 복합신소재구조학회 논문집
    • /
    • 제6권1호
    • /
    • pp.38-44
    • /
    • 2015
  • In this paper, a finite element dynamic simulation study was performed to gain an insight about the blast wall test details for the offshore structures. The simulation was verified using qualitative and quantitative comparisons for different materials. Based on in-depth examination of blast simulation recordings, dynamic behaviors occurred in the blast wall against the explosion are determined. Subsequent simulation results present that the blast wall made of high energy absorbing high manganese steel performs much better in the shock absorption. In this paper, the existing finite element shock analysis using the LS-DYNA program is further extended to study the blast wave response of the corrugated blast wall made of the high manganese steel considering strain rate effects. The numerical results for various parameters are verified by comparing different material models with dynamic effects occurred in the blast wall from the explosive simulation.

태양전지셀의 본질안전 방폭성능 평가 (The Intrinsic Safety Evaluation of Solar Photovoltaic Cell)

  • 이춘하;지승욱;김시국
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.49-54
    • /
    • 2011
  • Now the world will regulate the CO2 emission due to environmental issues. For an alternative plan photovoltaic system is watched. So, photovoltaic system is trend of big city and it is mandatory for renovation of construction. Oil & gas filling station existed in city is suitable to found the photovoltaic system. But the general photovoltaic system in oil & gas filling station is difficult to found because it is classified into hazardous area. This paper evaluates intrinsic safety evaluation of solar cell for making basic data to found for the photovoltaic system on hazardous area. The intrinsic safety characteristic is evaluated by short-circuit ignition test using IEC type spark ignition test apparatus and temperature rising test. The result of short-circuit ignition test, propane-air mixture gas is exploded on condition that 4 solar cells(9[V], 90[mA]) are connected serially under insolation 800[W/$m^2$]. So, if a larger solar module will be used at oil & gas filling station than we were tested, it needs explosion proof. As the result of rising temperature test, the temperature rising due to short circuit is not so much, but when the temperature rises due to radiant heat, it demands careful consideration for environmental influence.

유사연성 하이브리드 섬유를 이용한 복합패널의 구성 재료 기초 연구 (A Basic Research for Ductile Hybrid Fiber Composite Panels of Materials)

  • Kim, Woonhak;Kang, Seokwon;Hwang, Seongwoon
    • 한국재난정보학회 논문집
    • /
    • 제10권3호
    • /
    • pp.388-395
    • /
    • 2014
  • 본 논문에서는 구조물의 사용성 및 사용하중에 큰 영향을 미치지 않으며 기존에 개발되어진 재료를 활용하여 재료들의 방호 방폭 성능을 최대한 발휘할 수 있도록 복합패널을 구성하였다. 재료 각각의 특성이 발휘될 수 있도록 여러겹의 레이어 층으로 패널을 구성하였으며 구조물의 손상을 최소화 하고 강도와 내구성을 극대화 하여 일반 구조물 유지 보수에도 활용 가능한 보강용 패널의 제작을 위한 실험적 연구를 수행하였다.

편심하중을 받는 철근콘크리트 기둥의 폭발 저항성 평가 (An Evaluation of Blast Resistance Capacity of RC Columns under Eccentric Load)

  • 김한수;이재용
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.148-151
    • /
    • 2011
  • 현재 방폭설계 관련 설계지침은 기둥제거시나리오를 이용한 대체하중경로법을 주로 적용하고 있지만, 실제로 폭발이 발생하였을 때 기둥의 완전한 파괴가 일어나지 않을 경우 이 방식을 적용하는 것은 적합하지 않다. 따라서 본 논문에서는 비선형 동적 해석 프로그램인 AUTODYN을 이용해 편심하중을 받는 철근 콘크리트 기둥의 잔존 폭발 저항 성능을 평가하는 방식을 제안하였다. 해석결과를 비교해보면 TNT양과 축하중이 클수록 철근콘크리트 기둥의 잔존 폭발 저항 성능이 감소되었다. 이것은 폭발이 발생하기전의 기둥의 편심하중에 의한 응력상태에 따라 폭발 저항 성능이 달라짐을 알 수 있다.

  • PDF

폭발물 이격거리에 따른 기둥의 손상도와 저항성능 (Damage and Resistance of Columns Based on the Stand-off Distance from Explosives)

  • 노지은;이경구;정란
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.152-155
    • /
    • 2011
  • 최근 폭발 등 극한하중에 대한 관심의 증대와 함께 방폭 및 연쇄붕괴방지를 위한 연구가 활발히 진행되고 있다. 이에, 본 연구에서는 폭발하중하의 강구조물의 손상도와 저항성능을 수치적으로 평가하고자 하였다. 이를 위해 구조물의 폭발피해경감을 위해 가장 중요한 구조부재인 기둥을 대상으로 폭발물과 구조물과의 이격거리를 달리하여 폭발하중을 적용하였다. 유한요소해석을 수행한 결과를 토대로 기둥의 손상도와 잔여압축강도를 비교하고 관계를 도출하였다. 본 연구의 목적은 폭발에 의해 기둥이 손상된 경우 구조물 전체의 연쇄붕괴저항성능에의 손상된 기둥의 기여도를 평가하는 것이다.