• Title/Summary/Keyword: 방전 Power

Search Result 1,314, Processing Time 0.036 seconds

Electric Fire Prediction by Detection of Discharge Signal (방전신호 검출에 의한 전기화재 예측)

  • 길경석;송재용;권장우
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.413-419
    • /
    • 2004
  • This paper describes a technique that can predict electric fires by detection of discharge voltage signals caused by the use of electric facilities. In the experiment, various discharge modes, a flashover or a surface discharge through insulation paper and a line to line short, were simulated to acquire electrical information for predicting electrical fire as discharge modes. From the experimental results, it is hewn that electorial discharges which are ranked as majority causes of electric fires generate characterized signals distinguished from power frequency. Finally. We designed a prototype discharge detector based on the experimental results, and the detector is applied to a power lines. This study showed that the prediction of electric fires is possible by monitoring discharge voltage signals in electric power lines.

noise discrimination case of UHF partial discharge signal in GIS (변전소 GIS에서 UHF 부분방전신호의 노이즈 판별 사례)

  • Kim, Kyung-Tak;Goo, Sun-Geun;Han, Ki-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.145-146
    • /
    • 2008
  • OO변전소 154 kV GIS에서 부분방전측정 수행을 하였다. GIS내부 결함유무 및 위치를 판정하기 위해 현장 정밀측정을 한 결과 GIS 내부에서 발생하는 부분방전신호가 아닌 외부노이즈임을 세가지 측정방법을 통해 판별할 수 있었다.

  • PDF

Detection of Partial Discharge Acoustic Signal Using the Optical Fiber Interferometric Sensor (광섬유 간섭계 센서를 이용한 부분방전 음압 측정)

  • 이종길;박윤석;이준호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.7
    • /
    • pp.614-623
    • /
    • 2002
  • In this paper, it was manufactured an interferometric optical fiber sensor and measured partial discharge acoustic signal caused by defect of power facilities such as power cables, transformers and gas insulation. Acrylic and aluminium mandrels wound with fiber-optic were chosen as optical fiber sensor, Sagnac and Mach-Zehnder interferometers were chosen to detect discharge acoustic signals. The two fiber optic interferometers were identified by using the PZT. Discharge experimentation set in the discharge imitation cell in oil tank and the discharge phenomena was generated. Based on the experimental result, to detect the discharge acoustic signal, Sagnac interferometer can detect stably the acoustic signal than the Mach-Zehnder interferometer. It is shown that Sagnac optical fiber sensor can detect the discharge acoustic signals effectively.

mechanism of Equivalent Power Distribution in Parallel Connected ICP for Large Area Processing

  • Lee, Jin-Won;Bae, In-Sik;An, Sang-Hyeok;Jang, Hong-Yeong;Yu, Sin-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.510-510
    • /
    • 2012
  • 반도체, 디스플레이, 태양광 등의 공정에서 사용되는 웨이퍼의 크기가 증가하고, 생산률이 플라즈마의 밀도에 비례한다는 연구 결과가 발표되면서 대면적 고밀도 플라즈마 소스 개발에 대한 연구가 활발히 진행되고 있다. 특히, ECR, ICP, Helicon plasma 등 고밀도 플라즈마 소스에 대한 관심이 높아지고 있다. 이에 따라, 여러 개의 ICP를 결합한 multiple ICP를 이용해 대면적 고밀도 플라즈마 소스 개발을 진행했다. Multiple ICP의 경우 각 ICP 소스에 같은 power (current)를 공급해야만 균일한 플라즈마 방전이 발생되어 균일도를 확보 할 수 있다. Current controller 같은 추가적인 장비를 설치하지 않고, power를 분배하는 transmission line을 coaxial 형태로 설계하고 같은 길이로 병렬 연결함으로써 각각의 ICP소스에서 균일한 플라즈마를 방전시킬 수 있었다. Power generator에서 보는 각 ICP의 total impedance는 각 ICP 소스의 impedance와 coaxial 형태의 transmission line의 characteristic impedance, frequency, 길이의 함수로 구할 수 있고, 이 total impedance가 일정하기 때문에 current가 균등하게 분배되어 각 ICP소스에 균등한 power 분배가 가능한 것이다. 실질적으로 ICP 소스의 impedance는 플라즈마 방전 유무에 따라 변화하기 때문에 일정하게 유지하는 것은 어렵다. Transmission line의 characteristic을 사용함으로써 ICP의 impedance의 변화에 상관없이 Total impedance를 일정하게 유지시킴으로써 균등한 power 분배가 가능하다는 것을 연구했다. Frequency는 13,56MHz, characteristic impedance를 $50{\Omega}$ (coaxial cable)으로 고정하고, ICP 소스의 플라즈마 방전 유무/antenna turn/소스 위치에 따른 total impedance를 transmission line의 길이에 따라 측정하고, 이를 이론값, 그래프와 비교하였다. 특정 length에서 플라즈마 방전 유무(ICP의 impedance 변화)와 상관없이 비교적 일정한 total impedance를 유지하는 것을 확인 했다. 이것은 특정 길이를 갖는 coaxial형태의 transmission line를 연결하면, total impedance는 플라즈마 방전 유무로 발생하는 ICP의 impedance 변화와 상관없이 일정하게 유지되어 각 ICP소스에 균등한 파워 분배가 가능하다는 것을 보여준 결과이다. 이것을 토대로 frequency에 따라(또는 characteristic impedance에 따라) 균등한 파워 분배가 가능한 coaxial 형태 transmission line의 특정 길이를 구할 수 있고, 대면적 소스에서 균등한 파워 분배를 위한 병렬연결에 적용할 수 있을 것이다.

  • PDF

Study for Conductive and Non-conductive Multi-layers Depth Profiling Analysis of Radio Frequency Gas-jet Boosted Glow Discharge Spectrometry (Modified Gas-jet Boosted Radio-frequency Glow Discharge 셀의 개발 및 최적화에 관한 연구)

  • Cho, Won Bo;Borden, Stuart;Jeong, Jong Pil;Kang, Won Kyu;Kim, Kyu Whan;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.108-114
    • /
    • 2002
  • The new system using a glow discharge atomic emission spectrometer for the direct analysis of solid samples has been developed and characterized. The system was consisted of new glow discharge cell improved previous gas-jet boosted nozzle and radio-frequency power supply. In the case of previous type glow discharge chamber, it had been fitted trace analysis of low alloy steel with low discharge power, because it was to decrease redeposition and increase sample weight loss. But it had a problem that plasma becomes unstale due to increased sample weight loss and redeposition resulting from the high discharge power. Because of being problem of previous glow discharge, it is impossible to analyze using high power. The modified gas-jet boosted glow discharge to solve this problem would improve to be less sample loss rate of modified nozzle than sample loss rate of previous nozzle on the equal discharge condition, and improve to increase stability of plasma. The effect of discharge parameters such as discharge pressure, gas flow rate and power on the sample loss rate, emission intensity has been studied to find optimum discharge conditions. The calibration curves of Fe were obtained with 3 low-alloy samples.

Visible Light Spectrum of H2 Plasma Generated a Commercial Electric Power in the Parallel Plate Reactor (상용전원 평행판전극 방전장치에서 수소플라스마의 가시광선스펙트럼)

  • Choi, Woon Sang;Ji, Taek Sang;Kang, Sung Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.15-20
    • /
    • 1999
  • Visible light spectrum emitted from $H_2$ plasma in the parallel plate reactor using a commercial electric power are investigated by optical emission spectroscopy. Intensity of visible light is measured as a function of $H_2$ pressure and discharging power, and the intensity is compared with plasma density measured with the probe. As a result, the intensity is affected by plasma density and the plasma density is controlled the $H_2$ pressure and the discharging power.

  • PDF

Development of Hybrid Partial Discharge Diagnosis Equipment for GIS using SRPDA-Based Noise Reduction Technique (SPRDA 기반 노이즈 제거 기법을 이용한 하이브리드 방식 GIS 부분방전 진단장치 개발)

  • Go, Young-Ju;Park, Hyun-Soo;Lee, Jong-Oh;Yu, Kyoung-Kook;Chang, Doc-Jin;Seo, Jeong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1483-1484
    • /
    • 2015
  • 부분방전 진단 기술 분야에서는 노이즈의 영향을 최소화할 수 있는 기법이 요구되고 있는 실정이다. 본 논문에서는 부분방전과 노이즈 신호 추출을 위한 로그앰프의 반응 속도차와 부분방전 신호특성을 비교하여 노이즈를 제거하는 SRPDA(Speed Related Partial Discharge Analysis)를 적용한 부분방전 진단 시스템의 개발 내용을 나타내었다. 또한 본 시스템은 광대역 방식의 장점인 빠른 검출 속도와 협대역 방식의 장점인 적은 노이즈의 영향의 장점을 취하는 동시에, 광대역 방식의 단점인 큰 노이즈 영향과 협대역 방식의 단점인 느린 진단 속도를 개선할 수 있는 하이브리드 방식을 채택하여, 기존 부분방전 진단 시스템의 신뢰성을 개선할 수 있을 것으로 사료된다.

  • PDF

SOH estimation method based on simple linear regression model for high power lithium ion battery (고출력 리튬이온 배터리에 적합한 단순선형회귀모형 기반 SOH 추정 기법)

  • Lee, Pyeong-Yeon;Park, Jin-Hyeong;Yoon, Chan-O;Kim, Jonghoon
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.246-248
    • /
    • 2018
  • 본 논문에서는 배터리 수명의 지표인 SOH(state of health) 추정 시 배터리 노화에 따라 방전 용량의 급격한 변화가 발생하면 SOH도 변화하게 된다. 이로 인해 잘못된 SOH의 정보를 가지고 오게 되며 배터리의 안정성 및 신뢰성에 문제가 된다. 본 논문에서는 방전 용량과 내부 저항의 선형적 관계를 확인하고, 방전 용량과 내부저항을 고려한 단순선형회귀모형(simple linear regression model)을 모델링하였다. 방전 용량의 급격한 변화나 오프라인 기반 방전 용량을 측정함에 어려움이 있는 경우 단순선형회귀모형에 따라 방전 용량을 추정하여 SOH를 보정하는 기법을 제안하고 이에 대한 검증을 수행하였다.

  • PDF

Multi-level sustain Circuit of simple structure using low voltage switching device for PDP driving application (PDP 구동 응용을 위한 저전압 스위칭 소자로 구성된 간단한 구조의 Multi-level 유지방전 회로)

  • Kang Soon-Eun;Nam Won-Seok;Han Sang-Kyu;Hong Sung-Soo;SaKong Suk-Jin;Yang Hak-Chul;Roh Chung-Wook
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.75-77
    • /
    • 2006
  • 본 논문에서는 PDP 구동 응용을 위한 간단한 구조의 Multi-level 유지 방전 회로를 제안한다. 제안된 회로는 기존의 Multi-level 유지 방전 회로에 비해 적은 수의 스위칭 소자로 구현할 수 있어 간단한 구조를 가진다. 또한, 기존의 Multi-level 회로와 동일한 수준의 소자 전압 및 전류 스트레스를 가지므로, 저가의 고성능의 저전압 소자를 사용할 수 있어 PDP 구동 회로의 원가 저감과 고효율 동작을 이룰 수 있을 것으로 예상한다. 제안된 회로의 동작 원리를 설명하고, 42" HD급 PDP에 실제 적용 실험을 하여 제안된 회로의 우수성을 보인다.

  • PDF

Study on Characteristics of DBD Plasma Actuator as Design Parameters for Plasma Flow Control (플라즈마 유동제어를 위한 DBD 플라즈마 액츄에이터의 설계변수에 따른 특성 연구)

  • Yun, Su-Hwan;Kwon, Hyeok-Bin;Kim, Tae-Gyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.6
    • /
    • pp.492-498
    • /
    • 2012
  • Characteristics of DBD(Dielectric Barrier Discharge) plasma actuator as design parameters were investigated for plasma flow control. Flow velocity and power consumption of the DBD plasma actuator were measured according to the design parameters such as discharge voltage and frequency, gap, width and length of electrode, and the thickness of dielectric barrier. The flow velocity and power consumption increased as the discharge voltage and frequency increased. As the electrode gap increased, the flow velocity increased with decreasing the power consumption, whereas high voltage was required for the plasma discharge. The flow velocity increased as the upper-electrode width decreased, and as the lower-electrode width increased at the constant power consumption. The performance of the DBD plasma actuator can be estimated at the given discharge and geometry conditions.