• Title/Summary/Keyword: 방염제

Search Result 21, Processing Time 0.02 seconds

Flame Retardant Treatment's Effects and Detection Method on Wooden Buildings' Pigment Layer (Dan-cheong) (국내 목조건축물 단청의 방염제 처리에 따른 영향 및 탐지방법 연구)

  • Kim, Dae Woon;Kim, Chul Woong;Han, Sung Hee;Chung, Yong Jae;Han, Gyu Seong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.393-406
    • /
    • 2014
  • To figure out the problems of flame retardant treatment (FRT) on wooden buildings, field investigation and analysis of statistical data are performed. After FRT on historical wooden building, efflorescence and exfoliation showed most often. These problems appeared especially on column, rafter and Ga-gu (Ingredients for supporting structure of a roof) which are liberally spreaded. To compare before and after FRT, analyzed 20 elements using P-XRF. In this process, found sulfur which informs FRT. This helped set up nondestructive assay. Through this process, confirmed field application by analysis residue component of Songgwang-sa Temple.

Study on the Smoke Density Characteristics of Flame Retardant Sol Manufactured by a Sol-gel Method (졸-겔법으로 제조된 방염제졸의 연기밀도 특성에 관한 연구)

  • Cho, Kyeong-Rae;Lee, Chun-Ha;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.11-18
    • /
    • 2017
  • In this study, a non-halogen type organic-inorganic hybrid flame retardant sol, which can impart flame resistance to synthesize silicate of inorganic material and silane coupling agent of organic material by a sol-gel method, were newly manufactured. The addition of flame retardant will prevent loss of life in a fire because smoke from the flammability of interior finishing materials used as the construction materials poses a major danger. The smoke density measurement standard based on flame retardant performance standards, experiments were conducted according to the test equipment and procedures of ASTM E 662. The non-flaming mode experiment and the flaming mode experiment were conducted to confirm the performance of the manufactured flame retardant sol. As a result, the manufactured flame retardant sol improved the physical properties and heat resistance of existing flame retardants, and decreased the smoke production of the fire. Therefore, it may be possible to reduce the damage caused by smoke and expand the applications to various interior finishing materials.

Flame Retardant Performance of Functional Oil Stains According to the Mixing Ratio of Inorganic Flame Retardants and Phosphorus Flame Retardants (무기계 방염제와 인계 방염제 혼합비율에 따른 기능성 오일스테인의 방염성능)

  • Lee, Ju-Won;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.29-30
    • /
    • 2023
  • Wood is a construction material that has the advantages of carbon dioxide storage ability, noise reflection, and eco-friendliness. In order to use wood for a long time, you must use wood-specific paint, which is called oil stain. Oil stain improves water resistance and moisture resistance, but has the disadvantage of being weak against fire. This is because the oil contained in the oil stain causes a chemical reaction, and this chemical reaction causes the oil stain to spontaneously ignite, igniting nearby combustible materials and causing frequent fires. To improve this, in this study, different flame retardants were mixed and added to oil stain to produce functional oil stain. In addition, we would like to apply it to wood to check glow time and carbonization area. As a result of the experiment, it shows the best performance when mixed at 30(15 + 15)(%) and added to oil stain. The remaining burn time is satisfied from 10% for all samples, and the carbonized area is satisfied when it is 30%.

  • PDF

The Influence of the Commercial Flame Retardant to the Physical and Chemical Properties of Dancheong Pigments (시판용 방염제 도포에 의한 단청안료의 물리화학적 변화 연구)

  • Lee, Han Hyoung;Kim, Jin Gyu;Lee, Hwa Soo;Lee, Ha Rim;Chung, Yong Jae;Kim, Do Rae;Han, Gyu Seong
    • Journal of Conservation Science
    • /
    • v.32 no.2
    • /
    • pp.249-259
    • /
    • 2016
  • Effect of the flame retardants on Dancheong is studied in the present work. Two kinds of flame retardants were applied on Dancheong specimens and compared with control groups on which distilled water was applied instead of the flame retardants. The flame retardants enhanced the hygroscopic property of the surface of Dancheong. Furthermore, the added flame retardants reacted with oyster shell white($CaCO_3$) and lead red($Pb_3O_4$), producing new chemical compounds like Calcium phosphate tribasic and Lead Phosphates which make the painted layer of Dancheong dissolving and whitening over certain period of time. When applied in excessive amount and exposed in repetitive wet and dry condition, especially, they aggravate the surface problems significantly. These results will provide a good reference on the study of the discoloring/whitening effect of Dancheong layers at many traditional wooden building in Korea.

Impact Assessment of Flame Retardant on Wooden Building with Dancheong (목조문화재 단청에 방염제가 미치는 영향평가)

  • Kim, Hwan-Ju;Lee, Han-Hyoung;Lee, Hwa-Soo;Chung, Yong-Jae;Han, Kyu-Sung
    • Korean Journal of Heritage: History & Science
    • /
    • v.49 no.2
    • /
    • pp.56-69
    • /
    • 2016
  • Flame resistant treatment has been applied since 1973 for fire prevention in historical wooden buildings, but several problems, such as whitening and discoloration are constantly occurring in some Dancheong, in spite of evaluation criteria. It is supposed that these phenomena are caused by the stability issue of flame retardant, Dancheong production methods, the residue of chemicals, which were applied in the past, building location environments, etc., but no evaluation and cause inspection has been performed. Therefore, this study aims to verify the effect of flame retardant on Dancheong by producing Pseudo-samples and setting spatial and temporal environment conditions. Pseudo-samples of Dancheong were produced using three methods; the method specified in the Standard Specification of Properties; the method, which is generally used in the site and the traditional method. For different environment conditions of pseudo-samples, the areas were classified into a coastal area and an inland area and the places were classified into a sunny place and a wetland. After applying a flame retardant, annual variations were inspected for 12 months and change aspects were observed through scan and regular observation. In annual variation inspection, various variations like whitening, decolorization, dissolution and exfoliation were found and especially, whitening was most dominant. When the effect of flame retardant depending on the production methods was analyzed, whitening occurred in all the three production methods. It is supposed that this is because calcium(Ca) was contained in the coloring material of each production method and it reacted with phosphorous(P) of flame retardant. When the effect of flame retardant depending on the environment conditions was analyzed, whitening occurred more in the coastal area than in the inland area and it reduced in the building in a sunny place, which was constructed using the traditional method. It is supposed that this results from the humidity change and the difference of glue used in each production method. In conclusion, for using a flame retardant containing phosphorous(P), there is a need to check if calcium components including Oyster Shell White were used in Dancheong in advance and to conduct various preliminary studies on place conditions and Dancheong construction conditions.

Flame-resistant treatment schedule of Microwave drying wood (마이크로웨이브 건조목재의 방염처리 스케줄)

  • Park, Cheul-Woo;Her, Jae-Won;Lim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.27-28
    • /
    • 2011
  • This research aims to secure fundamental data for the development offire-retardant wood by soaking dried wood in fire-retardant liquid. To dry wood, optimal drying conditions for softwood usually used as structural material and hardwood usually used as finishing or furniture material were derived by varying the microwave outputs and heating times of microwave wood drying equipment. The research foundthat each specimen needs 8 to 15 minutes of heating time depending on water content and output. For softwood, fire-retardant liquid equivalent to about 10 percent of the total mass of the specimen infiltrated into the dried wood, of which the water content was reduced to 5~6 percent.

  • PDF

Effect of Fixation Methods on the Flame Retardant and Performance Properties of MDPPA/HMM treated Cotton (MDPPA/HMM처리 면직물의 고착방법에 따른 방염성과 물성의 변화)

  • 지주원;오경화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.1
    • /
    • pp.15-23
    • /
    • 2000
  • Effect of fixation methods on the flame retardant(FR) and performance properties of MDPPA/HMM treated cotton fabrics were studied. Combination of three different fixation methods - premercerization, swelling agent treatment, pad dry cure fixation, and wet fixation - were applied to flame retardant finish of cotton with MDPPA/HMM. As a result, an increase in internal volume of cotton fiber by pre-mercerization and addition of swelling agent, and wet fixation increased %add-on of FR agent improving FR efficiency and wash fastness. Tensile strength of MDPPA/HMM treated cotton fabrics by wet fixation and swelling agent were slightly decreased, but that of premercerized cotton was improved. Wet fixated fabric showed lower bending rigidity and better compressional properties which improved fabric hand. Retention of swelling ability of cotton treated with MDPPA/HMM improved moisture absorption properties.

  • PDF

A Study on how to Evaluation the Performance of Flame Retardant for Wood Treated with Painting (단청처리 목재용 방염제의 성능평가방법에 대한 고찰)

  • Cha, Jeong-Min;Hyun, Seong-Ho;Kim, In-Beom
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.498-501
    • /
    • 2011
  • 본 연구에서는 방염제가 적용되는 방염대상물에 대한 검정기술기준과 목조문화재에 적용되는 방염제의 검정기준의 차이에 대해 비교하여 보았으며 이를 통해 단청 등이 도색되어 있는 대부분의 목조문화재에 적용되는 방염제의 성능과 방염 처리되어진 일반 목재의 방염성능평가방법에 대하여 생각해 보았다. 목조문화재용 방염제 검정기준 내의 방염성 평가는 소방방재청 고시 제 2009-31호의 "방염제의 형식승인 및 검정기술기준"과 비교하였을 때 목재를 비교대상으로 할 경우 방염성능 기준 및 측정방법과 동일하거나 거의 유사하였으며 방염제의 물성 등에 대한 기본적인 평가방법 또한 동일한 것으로 나타났다. 그러나 시험시편에 대한 규정에 있어서 목조문화재용 시험편의 경우 일정 두께이하로 규정하고 있어 시험하는 시편의 두께에 따라 방염성능 평가기준에 도달하지 못하는 경우가 발생할 수 있을 것으로 판단되어진다.

  • PDF