Browse > Article
http://dx.doi.org/10.5658/WOOD.2014.42.4.393

Flame Retardant Treatment's Effects and Detection Method on Wooden Buildings' Pigment Layer (Dan-cheong)  

Kim, Dae Woon (Department of Biology, College of Natural Science, Kongju National University)
Kim, Chul Woong (Hanrim Conservation & Technology)
Han, Sung Hee (Hanrim Conservation & Technology)
Chung, Yong Jae (Department of Heritage Conservation & Restoration, Graduate School of Convergence Cultural Heritage, Korea National University of Cultural Heritage)
Han, Gyu Seong (Department of Wood and Paper Science, College of Agriculture, Life, & Environmental Sciences, Chungbuk National University)
Publication Information
Journal of the Korean Wood Science and Technology / v.42, no.4, 2014 , pp. 393-406 More about this Journal
Abstract
To figure out the problems of flame retardant treatment (FRT) on wooden buildings, field investigation and analysis of statistical data are performed. After FRT on historical wooden building, efflorescence and exfoliation showed most often. These problems appeared especially on column, rafter and Ga-gu (Ingredients for supporting structure of a roof) which are liberally spreaded. To compare before and after FRT, analyzed 20 elements using P-XRF. In this process, found sulfur which informs FRT. This helped set up nondestructive assay. Through this process, confirmed field application by analysis residue component of Songgwang-sa Temple.
Keywords
flame retardants; wooden building; dan-cheong; exfoliation; efflorescence;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 National Statistical Office. 2008. Management situation of cultural heritage, Number of designated cultural heritage.
2 Park, C.-W., Hong, S.-W., Lee, J.-K., Lim, N.-G. 2013. Flame Retardant and Weather Proof Characteristic of Dan-Chung Treated Wooden by Flame Retardant Performance 13(2): 122-130.   과학기술학회마을   DOI
3 Park, D. 2011. Fire Safety Measures for the Key Cultural Assets in Korea through Case Analysis. Journal of the Korean Society of Disaster Information 7(1): 64-74.
4 Park, S.-H., Baek, E.-S. 2011. A Study on the Ways of Securing the Effectiveness of Field Flame Retardant Coating Process. Journal of Korean Institute of Fire Sci. & Eng. 25(2): 95-100.   과학기술학회마을
5 Son, Y.S. 1988. Trace back on the past of flame retardant treatment and countermeasure in the Korea. Journal of Chemistry of Fire Prevention No.2(2): 31-41.
6 The Cultural Properties Protection Law. Article No.11228, Revision 2012.01.26.
7 Inspections of government offices(Cultural Heritage Administration) report. 2008. Policy recommendations for the prevention of Sungnyemun accident.
8 Back, M.-H., Lee, J.-H. 2010. The Study for Fire Prevention of Main Wooden Cultural Properties of Korea. Journal of Korean Institute of Fire Sci. & Eng. 24(3): 1-8   과학기술학회마을
9 Chang, H.-S., Cho, W.-S., Kim, H.-G.. 2008. A Study on the Methods of Fire-Safety in Cultural Property Wooden Buildings. Journal of Korean Institute of Rural Architecture 10(4): 25-32.
10 Kim, H.-J., Lee, S.-E. Oh, K.-H. 2011. A Study on the On-site Flame Resistant Treatment in Domestic. Journal of Korean Institute of Fire Sci & Eng. 25(2): 33-38.   과학기술학회마을
11 Kim, T.-G. 2010. Consideration on Fire-prevention Facilities for Wooden Cultural Heritages. CONSERVATION STUDIES 31: 156-171.
12 Korea Fire Institute. Standard of the flame-resistant test and detailed rules. Revision 2005.11.21.
13 Hong, S.-W. 2012. Analysis of Dan-Chung Treated Wooden by Flame Retardant Performance. Department of Architectural Engineering, The Graduate School, Tongmyong University: 30-38.
14 National Emergency Management Agency. Notification No. 2012-34, 2012.02.09, Standard for type approval system and goods inspection of flame retardant treatment.
15 National Statistical Office. 2006. damage of human life by burned site.