• Title/Summary/Keyword: 방연

Search Result 61, Processing Time 0.032 seconds

Standardization of the Performance Test Procedure for Smoke Control System (제연설비 성능시험방법의 표준화)

  • Kwark, Ji-Hyun
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.21-28
    • /
    • 2006
  • Since hot toxic gas included in the fire is the most principal reason of the death and has the fluid mechanical characteristics unlike air, smoke control method appropriate for the figure and structure of a fire room is needed and each unit of the smoke control system requests high performance according to this characteristics, for which performance test procedures and evaluation criteria must be established. Domestic criteria involved with the smoke control consist of the pre-investigation by documents and the part inspection, which has lots of problems because they are far from the performance based evaluation method compared with the references of developed countries. Consequently, domestic and international references were compared and analyzed, problems being emerged and standardization scheme of the test procedure was presented.

Smoke Control Performance of a Serial Structure Using "CONTAM" (CONTAM을 이용한 직렬형태 구조의 제연성능 구현에 관한 연구)

  • Kim, Mi-Seon;Seo, Dong-Gil;Gu, Seon-Hwan;Yoo, Young-Min;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.53-62
    • /
    • 2019
  • A recent trend shows that more buildings are being constructed as mixed-use (residential and commercial) properties for efficient land use. This has led to an increased frequency in the occurrence of fires and the associated potential risks. In particular, in case of high-rise apartments, at least one of the elevators in each building is installed for evacuation purposes separately from the emergency elevator; therefore, for a combined ancillary room and emergency elevator platform situation, the structure is inevitably in series with the evacuation elevator platform. Thus, a proposal for a new type of ventilation zone based on existing national fire safety codes is required to achieve smoke control performance. To this end, the air egress velocity and differential pressure of each ventilation zone are checked using the "CONTAM" software; further, an alternative is proposed to secure smoke control performance for series structures.

An Analysis on the Major Parameter and the Relations of Pressure Difference Effect of Leakage Area in the Smoke-Control Zone (제연구역의 주요 매개 변수 및 누설 면적 변화를 고려한 차압 형성 관계 분석)

  • You, Woo Jun;Ko, Gwon Hyun;SaKong, Seong Ho;Nam, Jun-Seok;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.27 no.1
    • /
    • pp.20-25
    • /
    • 2013
  • This study is experimentally analyzed to extract the major parameters affecting the performance of the smoke-control system and the relations of pressure difference between vestibule and supply air pressure zone effect of supply mass flow rate and leakage area in the smoke-control zone. To obtain this, the mock-up building of three-story scale with a total of 10 compartments was constructed, and several apparatus were also installed for in-situ measurement of the ventilation flow rate, pressure difference between compartments, smoke defensive air velocity, the opening-closing force of door, etc. This article show that pressure difference in the smoke-control zone is significantly related with leakage area of vestibule in low pressure region, leakage area of supply air pressure in over pressure region and both of them in pressure control region when the pressure control range of damper is 45 Pa~55 Pa.

A Study on Design Improvement for Smoke-Control System Using the Pressurization of the Elevator Shaft (승강로 가압 제연설비의 설계개선에 관한 연구)

  • Kim, Il-Young;Kim, Kyung-Jin;Hong, Ji-Hwan;Kwon, Chang-Hee;Yoo, Chul-Kwon
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.74-83
    • /
    • 2019
  • In the U.S., the pressurization of elevator shaft was developed in 1972 to allow vulnerable people, such as the elderly and weak who could not use escape stairs in case of fire, to evacuate. It is an advantage in terms of space saving by not using vertical ducts. This study drew the problem of the pressurization of elevator shaft based on the existing domestic patents and proposed improvements. The smoke control volume calculation method is proposed by using vertical modeling. Leakage gaps in elevator doors need to be reviewed through experimental data or actual data. The evacuation floor was divided, the openings in the elevator machine room were automatically closed to the fire signal and the relief damper was installed to improve the performance. The improved method functions as the smoke control damper supplying the air flow rather than maintaining the differential pressure. To increase reliability of the research results, the procedure was performed to verify by using Contam.

Dissolution of Pb from the Complex Sulphide Concentrates Containing Galena and Arsenopyrite by Alkaline Oxidative Leaching (황비철광(黃砒鐵鑛)과 방연광(方鉛鑛)의 혼합황화광(混合黃化鑛)의 알카리산화(酸化)에 의한 Pb침출(浸出))

  • Youn, Ki-Byoung
    • Resources Recycling
    • /
    • v.17 no.3
    • /
    • pp.42-47
    • /
    • 2008
  • In this work, the dissolution behavior of Pb from the complex sulphide concentrates containing Galena and Arsenopyrite by alkaline oxidative leaching was studied. The influences of leaching temperature, oxygen partial pressure, leaching time and NaOH concentration of leaching solution were examined at the leaching conditions in the range of $100^{\circ}C{\sim}140^{\circ}C$ temperature, $40psi{\sim}100psi\;PO_2$ and $0.5M{\sim}2M$ NaOH concentration. The optimum result was obtained at the leaching condition of leaching temperature $120^{\circ}C$, 100psi $PO_2$, leaching time 30min. and 2M NaOH concentration of leaching solution.

Cost-effectiveness Analysis for Clothing Design Improvement Using Ergonomic Methods: Evaluation of Flame-proof Clothing and Design Optimization (의복 개선 설계의 비용 대비 인간공학적 효과 분석: 방연복의 평가 및 최적 설계 도출)

  • Cho, Ja-Young;Jeong, Jung-Rim;Yeon, Soo-Min;Chang, Joon-Ho;You, Hee-Cheon;Kim, Hee-Eun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.45-58
    • /
    • 2008
  • Ergonomic techniques have been required to analyze the effectiveness of functional clothing design improvement in a systematic and analytic manner. The goals of the present study are to: (1) comprehensively and analytically examine the effectiveness of clothing improvement by using the relationship analysis between clothing design components (D) and ergonomic evaluation measures (E) and (2) prove the usefulness of cost-effectiveness analysis for clothing design optimization. The cost effectiveness analysis is comprised of the preliminary evaluation based on expertise and the in-depth evaluation where the D-E relationship analysis is applied. As a result of the cost effectiveness analysis applied to flame-proof clothing, an optimal design was identified by analyzing costs and qualitative/quantitative effects. In the preliminary evaluation, the expected effectiveness of each design alternative on wear efficiency and wear comfort was estimated. In the in-depth evaluation, however, the effectiveness of each design alternative was analyzed by quantitative evaluation in a wearing test using a questionnaire prepared based on the D-E relationship analysis. It was concluded that the D-E relationship analysis and the cost-effectiveness analysis are useful for comprehensive evaluation and optimization of functional clothing design.

Basic Study on the Performance of a Pressure-difference Control Damper Affected by Flow Disturbance in a Wind Tunnel (풍도 내 유동 교란과 자동차압 댐퍼의 성능 특성 기초 연구)

  • Yun, Yung-Min;Lee, Min-Jung;Kim, Nam-Il;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.16-23
    • /
    • 2009
  • The performance characteristics of a smoke damper, which aims to suppress the penetration of smoke to a safe area, have been tested under the regulation of the FIS 001. However, the improvement of the test methods and the regulation has consecutively been requested. From a view-point of fluid mechanical theory, a pressure control damper, that is installed at the end of the flow control system, is important and it dominates flow characteristics in all designed flow systems. In this study, the weak points of the regulation of the FIS 001 concerned with the pressure control damper was visited and the some important characteristics of the damper was examined. Based on these results, it was confirmed that the effects of flow disturbance in the air supplying duct on the performance of the damper are not significant. This results gives some information for the modification of the experimental regulation concerned to the pressure control damper.

Numerical Analysis on Flow Characteristics in the Pressurized Air Supply Smoke Control System (급기가압 제연설비의 내부 유동특성에 대한 수치해석)

  • Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.52-58
    • /
    • 2017
  • This study investigated the pressure difference distribution and the flow characteristics among room, ancillary room, and stair case by carrying out the numerical simulations on the air flow inside the pressurized air supply smoke control system. Numerical simulations were conducted to analyze pressure and velocity distribution of compartments by pressurized air supply for the air-leakage test facility which was built to measure the effective leakage area. In this study, the leakage of air was considered by locating the narrow slit onto fire door and window of room. Simulated results using this method precisely followed the previous experimental results for the pressure differences between the stair case and ancillary room. Predicted results showed that the local leakage of air rarely affected the overall flow pattern and pressure distribution. Although the average velocity over the door between room and ancillary room satisfied the regulation for fire safety, it was certified the unsafe outflow to ancillary room could be occurred in the local position such as the upper part of the door.

Ore minerals and Genetic Environments from the Baekun Gold-silver Deposit, Republic of Korea (백운 금-은광상에서 산출되는 광석광물과 생성환경)

  • Yoo, Bong-Chul;Lee, Hyun-Koo;Kim, Ki-Jung
    • Economic and Environmental Geology
    • /
    • v.39 no.1 s.176
    • /
    • pp.9-25
    • /
    • 2006
  • Baekun gold-silver deposit is an epithermal quartz vein that is filling the fault zone within Triassic or Jurassic foliated granodiorite. Mineralization is associated with fault-breccia zones and can be divided into two stages. Stage I which can be subdivided early and late depositional stages is main ore mineralization and stage II is barren. Early stage I is associated with wallrock alteration and the formation of sulfides such as arsenopyrite, pyrite, pyrrhotite, sphalerite, marcasite, chalcopyrite, stannite, galena. Late stage I is characterized by Au-Ag mineralization such as electrum, Ag-bearing tetrahedrite, stephanite, boulangerite, pyrargrite, argentite, schirmerite, native silver, Ag-Te-Sn-S system, Ag-Cu-S system, pyrite, chalcopyrite and galena. Fluid inclusion data indicate that homogenization temperatures and salinity of stage I range from $171.6^{\circ}C\;to\;360.8^{\circ}C\;and\;from\;0.5\;to\;10.2\;wt.\%\;eq.$ NaCl, respectively. It suggest that ore forming fluids were cooled and diluted with the mixing of meteoric water. Also, Temperature (early stage I: $236\~>380^{\circ}C,\;$ late stage $I: <197\~272^{\circ}C$) and sulfur fugacity (early stage $I:\;10^{-7.8}$ a atm., late stage I: $10^{-14.2}\~10^{-l6}atm$.) deduced mineral assemblages from stage 1 decrease with paragenetic sequence. Sulfur ($2.4\~6.1\%_{\circ}$(early stage $I=3.4\~5.3\%_{\circ},\;late\;stage\;I=2.4\~6.1\%_{\circ}$)), oxygen ($4.5\~8.8\%_{\circ}$(quartz: early stage $I=6.3\~8.8\%_{\circ}$, late stage $I=4.5\~5.6\%_{\circ}$)), hydrogen ($-96\~-70\%_{\circ}$ (quartz: early stage $I=-96\~-70\%_{\circ},\;late\;stage\;f=-78\~-74\%_{\circ},\;calcite:\;late\;stage\;I=-87\~-76\%_{\circ}$)) and carbon ($-6.8\~-4.6\%_{\circ}$ (calcite: late stage I)) isotope compositions indicated that hydrothermal fluids may be magmaticorigin with some degree of mixing of another meteoric water for paragenetic time.

Economic Impact of Gwangyang Bay Area Shipping and Port Logistic Industry on the Regional Economy: A Regional Input-Output Analysis (광양만권 해운항만산업의 지역경제 파급효과 분석: 지역산업연관분석 중심)

  • Kim, Sangchoon;Jang, Heunghoon;Kim, Seungchul
    • Journal of Korea Port Economic Association
    • /
    • v.31 no.4
    • /
    • pp.53-73
    • /
    • 2015
  • This study analyzes the economic impact of the shipping and port logistics industry in Gwangyang Bay Area on the regional economy. For this purpose, the study constructs an input-output table of 29 sectors for 2010 in the area. The main findings are as follows. In terms of production, value added, and share of employment, the regional shipping and port logistics industry accounts for approximately 10.8 percent, 6.0 percent, and 2.9 percent of the national shipping and port logistics industry, respectively. Moreover, the economic impact of the industry on the regional economy is estimated to be an increase in terms of production of about 6 trillion Korean won), to be an increase in value added of about 2.5 million Korean won, and an increase of about 16,000 in employment. Furthermore, the industry is found to have strong inter-industry linkages with the main manufacturing as well as the main producer service industries.