• Title/Summary/Keyword: 방어형

Search Result 381, Processing Time 0.026 seconds

Calculation of Primary Electron Collection Efficiency in Gas Electron Multipliers Based on 3D Finite Element Analysis (3차원 유한요소해석을 이용한 기체전자증폭기의 1차 전자수집효율의 계산)

  • Kim, Ho-Kyung;Cho, Min-Kook;Cheong, Min-Ho;Shon, Cheol-Soon;Hwang, Sung-Jin;Ko, Jong-Soo;Cho, Hyo-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.69-75
    • /
    • 2005
  • Gas avalanche microdetectors, such as micro-strip gas chamber (MSGC), micro-gap chamber (MGC), micro-dot chamber (MDOT), etc., are operated under high voltage to induce large electron avalanche signal around micro-size anodes. Therefore, the anodes are highly exposed to electrical damage, for example, sparking because of the interaction between high electric field strength and charge multiplication around the anodes. Gas electron multiplier (GEM) is a charge preamplifying device in which charge multiplication can be confined, so that it makes that the charge multiplication region can be separate from the readout micro-anodes in 9as avalanche microdetectors possible. Primary electron collection efficiency is an important measure for the GEM performance. We have defined that the primary electron collection efficiency is the fractional number of electron trajectories reaching to the collection plane from the drift plane through the GEM holes. The electron trajectories were estimated based on 3-dimensional (3D) finite element method (FEM). In this paper, we present the primary electron collection efficiency with respect to various GEM operation parameters. This simulation work will be very useful for the better design of the GEM.

Development of International Education and Training Program for Building Practical Competence in Radiation Protection (방사선방호 실무역량 강화를 위한 국제 교육훈련 과정 개발)

  • Kim, Hyun Kee;Son, Miyeon;Ko, Han-Suk
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Education and training is an important means of promoting safety culture and enhancing the level of competence of radiation worker in radiation protection. The existing international nuclear education and training of short duration has been carried out on the high-level officials and focussed on the classroom based training. The developing countries has been asking for support to cultivate their own technical experts to Korea which is a donor country exporting nuclear power plants. This paper summarizes the results of developing and operating the international education and training course to froster technical experts in radiation protection that emphasized practical training sessions and technical visits using the excellent domestic radiation facilities and infrastructure of education and training. It mentions the procedures of assessment and feedback as well. In an effort to maximize teaching-learning effects and to maintain consistency of the learning objectives, methods and assessment, SAT methodology has been applied on the processes of developing and operating the course. In the comparative and final assessment which were conducted at the beginning or at the end of training course, participants' average score increased around 2 points. The questionnaire of participants showed a high level of satisfaction of 4.0 points or above for the most of the questions. These imply teaching-learning methods applied to it might be effective. The teaching-learning methodologies may provide the opportunity to develop the customized training course for bringing up international technical experts and to shift educational paradigm from theory-oriented to on-site practice-based education.

Immediate Connection of Customized Zirconia Abutment Using Flapless Guided Surgery: A Clinical Report (무절개 수술을 이용한 맞춤형 지르코니아 지대주의 즉시 장착 증례)

  • Lee, Gyeong-Je;Choi, Byung-Ho;Kim, Hee-Jun;Jung, Seng-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.201-212
    • /
    • 2012
  • There are some similar aspects at histological and morphological characteristics between the peri-implant tissue and periodontal tissue and the direct attachment between the titanium and soft tissue around the implant called as "Functional ankylosis" can prevent the apical infiltration of inflammatory and bone resorption around implant. But, the repeated connection and disconnection of the abutment can destroy the mucosal barrier of soft tissue around the implant and can cause the marginal bone resorption. The amount of marginal bone resorption may reduced if the prosthetic abutment is placed at that time of surgery. Connection of the prosthetic abutment at surgery was limited because the low accuracy of conventional method, but by using of Cone Beam Computed Tomography(CBCT) and guide surgery, the 3-dimensional accuracy of implant placement became much higher than before and it became possible. This is a clinical case of immediate connection of prosthetic abutment and provisional restoration by using of precise CBCT diagnosis and pre-fabricated zirconia customized abutment at surgery and the alternative method is described in this article because of the clinically contentable results.

A Study On The Thermal Movement Of The Reactor Coolant System For PWR (가압 경수로의 냉각재 계통 열팽창 거동에 관한 연구)

  • Yoon, Ki-Seok;Park, Taek sang;Kim, Tae-Wan;Jeon, Jang-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.393-402
    • /
    • 1995
  • The structural analysis of the reactor coolant system mainly consist of too fields. The one is the static analysis considering the impact of pressure and temperature built up during normal operation. The other is the dynamic analysis to estimate the impact of postulated events such as the seismic loads or postulated branch line pipe breaks event. Since the most important goal of the RCS structural analysis is to prove the safety of the RCS during normal operation or postulated events, a widely proven theory having enough conservatism is adopted. The load occurring on the RCS during normal operation is considered as the basic design loading condition throughout whole plant life time. The most typical characteristic of the RCS during normal operation is the thermal expansion of the RCS caused by reactor coolant with high temperature and pressure. Therefore, the exact estimation on the thermal movement of the RCS is needed to get more clear understanding on the thermal movement behavior of the RCS. In this study, the general structural analysis concept and modeling method to evaluate the thermal movement of the RCS under the normal plant operation condition are presented. To discuss the validation of the suggested analysis, analysis results are compared with the measured data which ore referred from the standardized 1000 MWe PWR plant under construction.

  • PDF

Design of Embedded Security Controller Based on Client Authentication Utilizing User Movement Information (사용자의 이동정보를 활용한 클라이언트 인증 기반의 임베디드 보안 컨트롤러 설계)

  • Hong, Suk-Won
    • Journal of Digital Convergence
    • /
    • v.18 no.3
    • /
    • pp.163-169
    • /
    • 2020
  • A smart key has been used in a variety of embedded environments and there also have been attacks from a remote place by amplifying signals at a location of a user. Existing studies on defence techniques suggest multiple sensors and hash functions to improve authentication speed; these, however, increase the electricity usage and the probability of type 1 error. For these reasons, I suggest an embedded security controller based on client authentication and user movement information improving the authentication method between a controller and a host device. I applied encryption algorithm to the suggested model for communication using an Arduino board, GPS, and Bluetooth and performed authentication through path analysis utilizing user movement information for the authentication. I found that the change in usability was nonsignificant when performing actions using the suggested model by evaluating the time to encode and decode. The embedded security controller in the model can be applied to the system of a remote controller for a two-wheeled vehicle or a mobile and stationary host device; in the process of studying, I found that encryption and decryption could take less then 100ms. The later study may deal with protocols to speed up the data communication including encryption and decryption and the path data management.

Radiological Risk Assessment for $^{99m}Tc$ Generator using Uncertainty Analysis (불확실성 분석을 이용한 $^{99m}Tc$ 발생기 사용의 방사선위험도 평가)

  • Jang, H.K.;Kim, J.Y.;Lee, J.K.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.129-139
    • /
    • 2004
  • Recently, much attentions are paid to the risk associated with increased uses of medium size radiation sources in medical and industrial fields. In this study, radiation risks to the worker and to the general public due to $^{99m}Tc$ generator were assessed for both normal and accident conditions. Based on the event tree technique, exposure scenarios for various situations were derived. Uncertainty analysis based on the Monte-Carlo technique was applied to the risk assessment for workers and members of the public in the vicinity of the work place. In addition, sensitivity analysis was performed on each of the five independent input parameters to identify importance of the parameters with respect to the resulting risk. Because the frequencies of normal tasks are fat higher than those of accidents, the total risk associated with normal tasks were higher than the accident risk. The annual dose due to normal tasks were $0.6mSv\;y^{-1}$ for workers and $0.014mSv\;y^{-1}$ for public, while in accident conditions $3.96mSv\;y^{-1}\;and\;0.0016mSv\;y^{-1}$, respectively. Uncertainty range of accident risk was higher by 10 times than that of normal risk. Sensitivity analysis revealed that source strength, working distance and working time were crucial factors affecting risk. This risk analysis methodology and its results will contribute to establishment of risk-informed regulation for medium and large radioactive sources.

Performance Analysis of Electronic Personal Dosimeter(EPD) for External Radiation Dosimetry (전자개인선량계(EPD)의 외부피폭방사선량 평가 성능분석)

  • Lee, Byoung-Il;Kim, Taejin;Lim, Young-Khi
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.261-266
    • /
    • 2015
  • As performance of electronic personal dosimeter (EPD) used for auxiliary personal dosimeter in nuclear power plants (NPPs) has been being continuously improved, we investigated application cases in Korea and other countries and also tested it in NPPs to assess the performance of EPD for external radiation dosimetry. Result of performance tests done in domestic NPPs was similar to those obtained by IAEA in cooperation with EURADOS (IAEA-TECDOC-1564). In addition, EPD/TLD dose ratio has shown similar tendency of EPD/Film-badge dose ratio from the research by the Japan Atomic Power Company (JAPC) and EPD provided more conservative value than TLD or Film-badge. Although some EPD's failures have been discussed, EPD has shown continuous improvement according to the report of Institute of Nuclear Power Operation (INPO) and data from domestic NPPs. In conclusion, It is considered that the general performance of EPD is adequate for external radiation dosimetry compared with that of TLD, providing appropriate performance checking procedure and alternative measures for functional failure.

Development of Signal Processing Modules for Double-sided Silicon Strip Detector of Gamma Vertex Imaging for Proton Beam Dose Verification (양성자 빔 선량 분포 검증을 위한 감마 꼭지점 영상 장치의 양면 실리콘 스트립 검출기 신호처리 모듈 개발)

  • Lee, Han Rim;Park, Jong Hoon;Kim, Jae Hyeon;Jung, Won Gyun;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.2
    • /
    • pp.81-88
    • /
    • 2014
  • Recently, a new imaging method, gamma vertex imaging (GVI), was proposed for the verification of in-vivo proton dose distribution. In GVI, the vertices of prompt gammas generated by proton induced nuclear interaction were determined by tracking the Compton-recoiled electrons. The GVI system is composed of a beryllium electron converter for converting gamma to electron, two double-sided silicon strip detectors (DSSDs) for the electron tracking, and a scintillation detector for the energy determination of the electron. In the present study, the modules of a charge sensitive preamplifier (CSP) and a shaping amplifier for the analog signal processing of DSSD were developed and the performances were evaluated by comparing the energy resolutions with those of the commercial products. Based on the results, it was confirmed that the energy resolution of the developed CSP module was a little lower than that of the CR-113 (Cremat, Inc., MA), and the resolution of the shaping amplifier was similar to that of the CR-200 (Cremat, Inc., MA). The value of $V_{rms}$ representing the magnitude of noise of the developed system was estimated as 6.48 keV and it was confirmed that the trajectory of the electron can be measured by the developed system considering the minimum energy deposition ( > ~51 keV) of Compton-recoiled electron in 145-${\mu}m$-thick DSSD.

Effect of Dietary Supplementation of β-Carotene on Hepatic Antioxidant Enzyme Activities and Glutathione Concentration in Diabetic Rats (β-Carotene의 섭취가 당뇨 유도 흰쥐의 간조직 항산화효소 활성과 Glutathione 함량에 미치는 영향)

  • Jang, Jung-Hyun;Lee, Kyeung-Soon;Seo, Jung-Sook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.8
    • /
    • pp.1092-1098
    • /
    • 2011
  • The present study was conducted to investigate the effect of ${\beta}$-carotene on the antioxidant system of rats with diabetes. Forty Sprague Dawley rats were fed the AIN-76 control diet or the same diet supplemented with ${\beta}$-carotene (7.2 mg/kg diet) for 3 weeks, then diabetes was induced in half the rats by administering streptozotocin (45 mg/kg BW) into the femoral muscle. Diabetic and normal rats were fed the experimental diets for 2 more weeks. To investigate the effect of dietary ${\beta}$-carotene on diabetes, the activities of antioxidative enzymes and glutathione concentration were determined in normal and streptozotocin-induced diabetic rats. The plasma glucose levels in diabetic rats were not influenced by the dietary supplementation of ${\beta}$-carotene. Hepatic activities of catalase and superoxide dismutase in diabetic rats were significantly lower than those of control rats but ${\beta}$-carotene tended to induce these activities. Glutathione-S-transferase activity was not significantly different between experimental groups. Glucose-6-phosphatase activity was induced in diabetic rats, but dietary supplementation of ${\beta}$-carotene reduced this activity. The hepatic concentration of reduced glutathione in diabetic rats was lower than that of control rats, but dietary supplementation with ${\beta}$-carotene restored the content to some extent. These data suggest that diabetic rats are exposed to increased oxidative stress and that dietary supplementation with ${\beta}$-carotene may reduce its detrimental effects.

Effects of Red Ginseng Component Administration on Glutathione and Lipid Peroxidation Levels in Mice Liver (홍삼 활성 성분이 생쥐 간 조직에서 Glutathione 및 지질과산화에 미치는 항산화 효과)

  • Sung, Kum-Soo;Chun, Chul;Kwon, Yong-Hun;Chang, Che-Chul
    • Journal of Ginseng Research
    • /
    • v.24 no.4
    • /
    • pp.176-182
    • /
    • 2000
  • The effects of red ginseng component (water extracts, alcohol extracts, lipophilic extracts, total saponins, panaxadiol and panaxatriol) administration on glutathione (GSH) and lipid peroxidation levels in mice were investigated. 20~25 g ICR mice which were pretreated with water extracts (50 mg/kg), alcohol extracts (50 mg/kg), lipophilic extracts (50 mg/kg), total saponins (50 mg/kg), panaxadiol (50 mg/kg) and panaxatriol (50 mg/kg) for 15 days. The ability of red ginseng component to protect against oxidative damage to the mouse liver was examined by determining the level of lipid peroxidation (MDA), glutathione, and the activities of glutathione peroxidase (GPX). The GSH level was raised by all the ginseng component, but the GSSG level was lowered ]argely by all the ginseng component. The ratio of GSSG/total GSH was decreased because the level of GSSG was decreased more than that of GSH. Finally, the lipid peroxidation (MDA) level was the lowest in lipophilic extracts and panaxadiol nest. In conclusion, the order of effectiveness of anti-oxidants was to be lipophilic extracts>panaxadiol>total saponins.

  • PDF