• Title/Summary/Keyword: 방수층

Search Result 95, Processing Time 0.023 seconds

The Performance of a New Pressure Reducing Valve Automatically Preventing Pressure Equalization (자동 균압 방지 감압밸브의 감압성능에 관한 연구)

  • Park, Yong-Hwan;Kim, Sang-Wook;Kim, Beom-Kyu
    • Fire Science and Engineering
    • /
    • v.27 no.1
    • /
    • pp.26-30
    • /
    • 2013
  • It is necessary to use pressure reducing valves to provide required water pressure in water-based fire suppression systems of the tall buildings. In many cases, however, pressure reducing valves lose their function due to the phenomenon of pressure equalization caused by valve leak. This study carried out performance evaluation of the recently developed pressure reducing valve to prevent pressure equalization and found it can maintain designed pressure reducing ratio within 11% variation and prevent pressure equalization by automatic self-lock function of the piston.

Causes of Asphalt Waterproofing Membrane Dissolution due to the Addition of the Solvent in Hybrid Water-proofing System (복합방수공법에 있어서 용제 첨가에 따른 아스팔트층 용해원인에 관한 연구)

  • Kim, Dong-Bum;Seo, Hyun-Jae;Song, Je-Young;Kwak, Kyu-Sung;Bae, Kee-Sun;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.53-56
    • /
    • 2010
  • In this study, we conducted an impact assessment of the amount of volatile organic solvents addition on hybrid water-proofing system of urethane waterproof coating material and modified asphalt sheet. Also, we conducted a comparative assessment of whether modified asphalt sheet is dissolved or not and oil leakage by dissolution in order to perform a comparative analysis of characteristics of the impact on modified asphalt sheet according to the volatility of volatile organic solvents included in urethane waterproof coating material. The test was carried out by adding the same amount of organic solvents into each experimental group which is subject to volatility and non-volatility of organic solvents, respectively. The results of the test showed that in both experimental groups modified asphalt sheet was dissolved when adding over 10 percent of organic solvents regardless of volatility, and oil leakage observed only in the experimental group subject to volatility.

  • PDF

Analysis of the Electromagnetic Scattering by Conducting Strip Gratings with 2 Dielectric Layers (접지평면위에 2개의 유전체층을 가지는 도체띠 격자구조에서의 전자파산란 해석)

  • 김용연;방성일
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.4 no.1
    • /
    • pp.102-109
    • /
    • 1999
  • In this paper, Electromagnetic scattering problem by a perfectly conducting strip grating with 2 dielectric layer on a grounded plane by incidence of a electric wave is analyzed by applying the PMM (Point Matching Method) known as a simple procedure. The scattered electromagnetic fields are expanded in a series of Floquet mode functions. The boundary conditions are applied to obtain the unknown field coefficients and the conducting boundary condition is used for the relationship between the tangential electric field and the electric current density on the strip When the incident angle is normal incidence the minimum value of the geometrically normalized reflected power according as relative permittivity is increased it should be noted that the value of the strip width gets moved toward high value. Them most energy by a normal incident wave is scattered in direction of the other angles except normal incident angle.

  • PDF

The Change of Dweller's Residents Stability on Residential Environment Improvement Projects: Focused on Apartment Housing Construction Method (주거환경개선사업으로 인한 거주자들의 주거안정 변화: 공동주택건설방식을 중심으로)

  • Kim, Hong-Joo;Kim, Joo-Jin
    • Land and Housing Review
    • /
    • v.5 no.2
    • /
    • pp.69-79
    • /
    • 2014
  • Residential Environment Improvement Project (REIP) which has started in 1989 and continued with 3rd government-supporting project in 2013 has lots of policy changes and related studies. However, the related researches have focused on residents resettlement into the project site, this paper is more interested in the residents stability than residents resettlement. So, this paper analyzes the changes of residents stability on the site of REIPs (with 3 groups of dwellers, removers and newcomers). We survey about understanding of those projects, each interior physical housing characters, housing cost, outside settlement characters. On the base of case analysis, we can conclude as follows: firstly, the residents are more young, higher educated, and higher income but not alter to household, barrier, occupation. Secondly, REIPs have some positive influences on physical conditions of housing and outside characters but negative impacts on housing cost. In case of newcomers, there are no changes of housing size and room numbers but higher housing cost, better outside settlement conditions.

형광체기반 Application에서 페를린 증착 유무에 따른 광학적 농도 변화에 대한 연구

  • Kim, Gyo-Tae;Hong, Ju-Yeon;Kim, Jin-Seon;Heo, Ye-Ji;Sin, Jeong-Uk;Heo, Seung-Uk;Park, Ji-Gun;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.397.1-397.1
    • /
    • 2014
  • 최근 방사선 진단 영역에 이용되고 있는 증감지는 입사된 방사선의 감도를 증가시키기 위해 형광체를 사용하고 있으며, 외부의 에너지를 흡수하여 빛으로 방출하는 역할을 한다. 이는 방사선 검출기, 디스플레이, 의료기기 등 다양한 분야에 활용되고 있다. 필름에 X선을 노출 할 경우 형광체의 사용 유무에 따라 방사선 흡수 효율에 영향을 미치며, 이는 발광 효율 및 감도에 주요한 인자로 작용한다. 현재 상용화되어 있는 형광체는 낮은 발광 효율로 인한 한계를 가지므로, 발광 효율 향상을 위하여 제작 구조에 대한 연구가 진행되고 있다. 이 중 반사막을 활용하는 연구가 활발히 진행되고 있다. 일반적으로 형광체의 제조를 위하여 보편적으로 이용하고 있는 스크린프린팅 방법에서 건조 공정을 수행 시 균일도가 감소하는 현상이 발생한다. 이러한 현상은 반사막의 증착을 불균일하게 만드는 원인으로 작용하고 빛의 산란을 초래하는 현상을 초래한다. 이에 본 연구에서는 증착 시 투명도 저하에 따라 반사율이 증가되는 반사막 성질을 가지며, 방수성 및 절연성과 같은 보호층 특성을 지닌 유기성 투명 박막 페를린에 대하여 연구하고자 한다. 본 연구에서는 화학적 증기 증착법(Chemical Vapor Deposition, CVD)을 이용하여 투명 필름의 상단에 페를린을 코팅한 시편과 코팅하지 않은 시편으로 구분하여 제작하였고, 상단에 스크핀프린팅 방법을 활용하여 형광체를 도포 하였다. 시편 제작 후 실험은 시편을 필름 상단에 위치시키고, 일반진단에너지 대역(Model-SF 80)의 X선을 조사하였다. 이 후 현상기(model-pro14)를 통해 현상된 필름에 나타난 광학적 농도(Optical Density, O.D)를 농도계(Fluke Biomedical Nuclear Associates Densitometer)로 측정하였는데, 불확실성을 줄이기 위하여 총 5회를 측정하여 그 중 2번째로 높은 값을 도출하였다. 측정 결과, 페를린을 코팅한 형광체에서는 1.71의 O.D 값이 측정되었고, 페를린을 코팅하지 않은 형광체에서는 1.43의 O.D 값이 측정되었다. 이를 이용하여 투명도를 산출한 결과 상대적으로 약 1.76% 차이가 나타났다. 이러한 결과는 페를린 활용 시 환자의 피폭 선량 저감화 및 해상력 개선을 도모할 수 있을 것으로 사료된다.

  • PDF

Questions and Solutions on Repair of Lime-Soil Consolidation in Traditional Buildings (전통 건축물 석회다짐층 보수 시공시의 문제점 및 개선 방안)

  • Kim, Jin-Man;Kwak, Eun-Gu;Suh, Man-Cheol;Cho, Heon-Young
    • 한국문화재보존과학회:학술대회논문집
    • /
    • 2002.02a
    • /
    • pp.21-31
    • /
    • 2002
  • Lime-soil consolidations are very important as structural material, bonding material, waterproofing material, and finishing material in korea traditional buildings. In this study, we investigated site application trouble in korea traditional buildings being repaired or restored, and propose following solutions. 1) To diminish quality variation occurred by slaking quick-lime in site, it is desirable to use slaked-lime for lime-soil consolidation. 2) For uniform construction of lime-soil consolidation, we would recommend builders to use mixer to be uniform mixture, premixed type materials and compacting machine in field, 3) and to use rigid suitable temporary construction as scaffold for preventing traditional buildings from additional damage occurred in demolition and construction of a layer of lime-soil consolidation of a roofing. 4) For suitable repair of traditional buildings, it is necessary to specify definitely materials and construction methods suggested by the standard specifications for repair of the cultural property.

  • PDF

The Development of High Pressure Long Distance Fire-fighting Hose with Phosphorescent Performance (축광 성능을 갖는 고압용 장거리 호스 개발에 관한 연구)

  • Han, Yong-Taek;Na, Byung-Gyun;Choi, Jin-Seong;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.63-69
    • /
    • 2017
  • This study describes the development of a long-distance hose for ultra-high pressure operation, which can be used in conjunction with an ultra-high pressure pump and can be effectively applied to the fire suppression of high-rise buildings and a long, large tunnels. Also, it has phosphorescent properties, which can help to secure the withdrawal route of the fire-fighters when they are threatened by the fire. We developed an ultra-high pressure hose aiming at a pressure of 3 MPa and a flow rate of 2000 lpm and developed an ultra-high pressure fire hose that can withstand this very high pressure by using a double jacket, triple polyurethane coating and warf (Wp) of 52. In order to ensure the performance of the developed ultra-high pressure hose, its structure, appearance, leakage at high pressure, length and elongation were inspected by a certified certification agency, who also subjected it to a peeling test, friction test, breaking pressure test and free fall test. Also, it was studied in addition to the luminescent high-pressure hose for fire-fighting. In the phosphorescence test, the luminance measurement value was more than the reference value of the luminance test after 40 minutes, which confirmed that its performance was satisfactory for fire-fighting products. In the future, if such an ultra-high pressure fire hose were commercialized and applied in the field, it could contribute to securing improved fire suppression and safer exit from fires, as compared to the fire hoses currently used in the suppression of fires in skyscraper buildings and long tunnels.

Formaldehyde Monitoring of Hygiene Products in Domestic Market (국내 유통 위생용품 중 포름알데히드 잔류량 모니터링)

  • Na, Young-Ran;Kwon, Hyeon-Jeong;Cho, Hyun-Nho;Kim, Hyeon-Jin;Park, Yon-Koung;Park, Sung-Ah;Lee, Seong-Ju;Kang, Jung-Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.3
    • /
    • pp.225-233
    • /
    • 2020
  • By the standards and specifications for hygiene products, three test methods for formaldehyde are specified for each item type of hygiene product. After derivatization using acetylacetone and 2,4-dinitrophenylhydrazine (2,4-DNPH), formaldehyde is analyzed by spectrophotometer and high-performance liquid chromatography (HPLC). Validation of the three test methods was performed on tissue, diaper lining and waterproof layer, and panty liner products. The results of linearity (R2), limit of detection (LOD), limit of quantification (LOQ), recovery rate (%) and reproducibility (%), showed that all three methods are suitable for analyzing formaldehyde in hygiene products. After derivatization with 2,4-DNPH and cetylacetone, formaldehyde was analyzed at 0, 3, 6, 9, 24 and 48 hours by HPLC. Formaldehyde derivatized with 2,4-DNPH showed no statistically significant change in formaldehyde peak area over time (P>0.05). But, acetylacetone-derivatizated formaldehyde showed a negative correlation coefficient (r) over time (P<0.01). We investigated the residual amounts of formaldehyde in 205 hygiene products distributed in Busan. Among 74 disposable diaper products tested, 73 had low concentrations of formaldehyde (0.13-29.87 mg/kg). Moreover, formaldehyde was not detected in any of 78 tissue, 27 disposable paper towel, 12 disposable dishcloth, 7 paper cup, one brand of paper straw and 6 disposable napkin products.

Evaluation on the Performance of Surface Performance Improving Agent for the Deterioration Prevention of Concrete Structures (콘크리트 구조물의 열화방지를 위한 표면 성능 개선제의 성능 평가)

  • Ryu, Gum-Sung;Koh, Kyoung-Taek;Kim, Do-Gyeum;Lee, Jang-Hwa
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.4
    • /
    • pp.177-186
    • /
    • 2005
  • The latest concrete structure has showed that the deterioration of durability has been increased by the damage from salt, carbonization, freezing & thawing and the others. Therefore, the measures for the concrete which has deteriorated durability have been taken. Among them, it has been often used that surface treatment which cuts off the deterioration factors of durability by protecting the surface of concrete. However, troubles such as fracture and rupture in the repair layer have been reported as time goes by due to the difference between the organic repair material like epoxy and concrete properties. Researchers have been developing the repair material which can cut off the deterioration factors of durability such as $CO_2$ gas, chloride ion and water by making the formation of concrete elaborate through the reaction with calcium ion when the surface improving agent is coated on the concrete. The main ingredient of that is inorganic substance which is the same as the concrete property. This study was evaluated the surface improving agent for permeability, watertightness, air-permeability, chemical resistance and elution resistance. As a result, it has been reported that the surface improving agent improves watertightness and air-permeability by penetration more than 10mm within concrete. Therefore, it is concluded that the surface improving agent developed in this research prevents deterioration of concrete durability when it is coated on the concrete structure.

A Study on the Variation of the Surface and Groundwater Flow System Related to the Tunnel Excavation in DONGHAE Mine Area (II) - Hydrogeochemical Consideration (동해신광산 터널굴착공사와 관련된 지표수 및 지하수의 유동변화에 대한 조사연구 (II)-수리지구화학적 고찰)

  • 전효택;이희근;이종운;이대혁;류동우;오석영
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.1
    • /
    • pp.27-40
    • /
    • 1997
  • The hydrogeochemical study on the 15 natural waters was carried out in the vicinity of tunnel excavation site of Donghae largely composed of granite and limestone. The water samples can be classified based on their chemical characteristics into two groups; waters draining in the granitic region(group 1) and the limestone region(group 2). This classification was also confirmed by statistical examination through cluster analysis, and the tunnel seepage waters collected at the same site appear to be included in group 1 and 2 by their sampling period, respectively. According to factor analysis, the waters of group 1 art mainly represented by the weathering of plagioclase to kaolinite and those of group 2 are characterized by the dissolution of calcite. Different properties of the tunnel seepage waters are thought to be resulted from the effective waterproofing processes conducted during the sampling interval to the surface and subsurface leakage zones at the granitic region, which contributed to the change of groundwater flow system. However both the tunnel seepage waters seem to have thermodynamically interacted with rock-forming minerals in their wallrocks. The mixing ratio of the waters from two groups and water-rock interactions are evaluated quantitatively for the tunnel seepage waters through the mass balance approach, and the results are identical with the previous conclusions in this study.

  • PDF