• Title/Summary/Keyword: 방수방식

Search Result 82, Processing Time 0.027 seconds

A study on the Reduction of Scattering of Polyurea Coating for Waterproofing and Anti-Corrosion by Installing Air Jet Nozzle (에어분사구 설치에 따른 폴리우레아 도막 방수·방식재의 비산 발생 저감에 관한 연구)

  • Kim, Sun-Do;Park, Wan-Goo;Park, Jin-Sang;Cho, Il-Kyu;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.236-237
    • /
    • 2017
  • This study discusses the development of waterproofing layer jet-spray nozzle that forms a three-dimensional air cell. This nozzle has an air flow generation mechanism in the air groove of the attachment cell part located at the end of the injection nozzle. Since the air grooves also function as an air curtain, the airborne particles generated when the waterproof material is sprayed is effectively blocked. In the past, spraying of the waterproof material through the high pressure was possible, but this technology allows stable injection due to the static agitation method, and various problems caused by particle generation has been (damages to neighboring areas, economic loss, etc.) minimized.

  • PDF

The Study on the Safety Adhesion Test of Wet Surface for Waterproofing and Anti Corrosion Materials of Water Supply Facility (수처리 시설물에 적용되는 방수·방식재의 습윤면 부착 안정 성능평가방법에 대한 연구)

  • Choi, Su-Young;Kim, Dong-Bum;Park, Jin-Sang;Park, Wan-Goo;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.137-138
    • /
    • 2017
  • The Waterproofing and Anti corrosion materials applied to the water supply facility did not consider environment of water supply facility, thus defects occurred consistently on the site. In this study, it suggests safety adhesion test of wet surface and have a test for safety adhesion performance.

  • PDF

Adhesion Performance of Electromagnetic Induction Heating Pixture for the Integration with a Waterproof & Root Barrier Sheet and a Roof Green Unit System (방수·방근시트와 옥상녹화 박스유닛 시스템의 일체화를 위한 전자기 유도가열 융착 고정구의 부착성능)

  • Oh, Chang-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.5
    • /
    • pp.463-469
    • /
    • 2018
  • A currently used roof green system with multi layers has a low constructability. Therefore a new integrated waterproof & root barrier sheet and roof green box unit system was developed using steel plate fixture and cone type fixture by electromagnetic induction heating method. This study was proceeded to evaluate adhesion performance of two types of fixtures on Engineering PE, TPO, PVC sheet in a normal condition, repeated heating and cooling condition. As a result, adhesion load on Engineering PE sheet showed the highest value. The adhesion loads of steel plate fixture showed higher value as heating temperature was getting higher. However adhesion loads of cone type fixture showed opposite tendency. Regarding to the test conditions, test results of normal condition, repeated heating and cooling condition showed same value. The cone type fixture using butyl tape showed 7 times lower adhesion load than that of cone type fixture using electromagnetic heating and 28% lower adhesion load in a repeated heating and cooling condition than a usual condition.

Current Effective Recycling and Application Methods in Construction Waterproofing Industries (건설방수산업분야에서의 유효자원 재활용 및 응용 기술 현황)

  • Park, Jin-Sang;Kim, Sun-Do;Park, Wan-Goo;Kim, Dong-Bum;Lee, Jong-Yong;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.1
    • /
    • pp.31-37
    • /
    • 2016
  • This paper intends to analyze the roles of regulations and certifications within the construction market that affect the effective recycling and application methods of construction waterproofing industries. Certifications, eco-labels, green certification patents, and new excellent technologies obtained in construction waterproofing industries are studied. In accordance to the study results, it was determined that, a total of 38 items obtained eco-labels with effective recycling as the theme, 10 items with green certifications, and 8 items with New Excellent Technologies. Regarding the types of effective recycled resources, most of them were concerned with composite-polymer(EVA, PVC, etc.) materials, waste tire powder, waste rubber, etc., which indicated that there is a clear limitation in the variety of the materials that are eligible for effective recycling in the construction waterproofing industries.

A Study on the Properties of Anticorrosive for RC Structure (콘크리트구조물 보수용 방식피복재의 특성)

  • Moon, Han-Young;Shin, Dong-Gu;Kwon, Yong-Jin;Oh, Sang-Kun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.1
    • /
    • pp.251-258
    • /
    • 2005
  • Up until now, most protection design has been concerned primarily with concrete's exterior protection from corrosion, its waterproof ability and its reparability. However, there are many cases in which service life of the concrete is shortened because suitability of the type of concrete surface has not been thoroughly investigated in the development process. According1y, this paper presents the development and test of the material for its reparability and its protection against corrosion in the case of wet surfaces (i.e. water supply facilities, sewage systems, and port facilities) in this country. From the test, both A type and B type are excellent for durability in watertightness, chemical resistance and abrasion. Test results of adhesive strength over $15kgf/cm^2$ under both wet and dry conditions, curing conditions and various temperatures conditions were also achieved in field tests.

Applicability of Composite Polyurea Method Considering the Required Performance in Underground Parking Lot Upper Slab (공동주택 지하주차장 상부슬래브의 요구성능을 고려한 복합형 폴리우레아 공법의 적용성 검토)

  • Lee, Jung-Hun;Choi, Eun-Kyu;Song, Je-Young;Kim, Soo-Yeon;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.3
    • /
    • pp.243-254
    • /
    • 2019
  • In this study, problems of the waterproofing methods in which water leakage occurs in the upper slab of the underground parking lot of apartment houses and the requirements considering the characteristics of the upper slab, and selected the appropriate performance(proposal) for the composite polyurea process are reviewed. As a result of the study, it is necessary to review performance such as responsiveness to upper slab of the multi-unit underground parking lot that is comprised of (1) crack and behavior responsiveness, (2) surface integrity, (3) vertical watertight stability, (4) pressure layer construction, (5) impact and pressure response and (6) vehicle moving load. As a result of evaluating 5 items corresponding to the requirements for the soft and hard complex polyurea, all of them were found to meet the conditions, and each materials were improved by compounding the materials that had problems when applying a single-ply method, thereby clarifying the advantages and disadvantages of the material property. However, in order to apply to the actual site, additional evaluation on site applicability such as mock-up evaluation should be conducted, and subsequent studies on the applicability of the market through review of economic feasibility and maintenance is required.

A Study on the Decompression Performance by the Orifice Diameter (오리피스의 직경에 따른 감압성능에 관한 연구)

  • Park, Bong-Rae;Yun, Ki-Jo;Jang, Kyeong-Nam;Choi, Jung-Ung;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.57-63
    • /
    • 2012
  • The modern trend for high-rise buildings makes the application of fire protection systems difficult and the current systems have a limitation to provide appropriate functions. Indoor hydrant systems are fire suppression systems installed in most buildings that require valves, hoses, and nozzles to be manually operated in the event of a fire. Therefore, high discharge pressure can cause difficulty in the operation of indoor fire hydrant systems and damage to hoses due to a high reaction force. To prevent these problems, the pressure is reduced and decompression valves are commonly installed at angle valves which are the discharge points of indoor hydrants. In the case of high-rise buildings, however, there are cases where stable operation is difficult even with the installation of decompression valves. To verify this, we have measured the decompression performance by the orifice diameter and calculated the reaction force. Results of the study showed that decompression valves need to be produced in different sizes to provide stable decompression where high pressure is required as in high-rise buildings.

Performance of Decompression Orifices Attached to Indoor Hydrant Discharge Outlets (옥내소화전 방수구에 부착되는 감압오리피스의 감압성능에 관한 연구)

  • Park, Bong-Rae;Lee, Meng-Ro;Jang, Kyung-Nam;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.6-12
    • /
    • 2015
  • Indoor hydrant facilities are used to fight initial fires before more intense fire extinguishing activities. Fire extinguishing facilities should ensure good fire extinguishing performance and the safety of users. Indoor hydrant facilities are mostly installed in buildings and facilities, and users must manipulate valves, hoses, and nozzles manually. When the discharge pressure is higher than 0.70 MPa, there is a high possibility that problems with manipulation and hose breakdown can occur. To prevent these problems, a method to attach orifice-type decompression valves to the angle valves of indoor hydrant discharge outlets has frequently been used for decompression methods. However, the decompression performance was reduced due to structural problems of the decompression valves over time. Accordingly, based on three-stage initial pressures, applicable pressure ranges were selected by measuring the decompression performance according to the diameter of the decompression orifices. Based on the data, stable decompression valve models are proposed. These models have the lowest decrease in decompression performance, regardless of time.

Performance Appraisal of the Ceramic Metal Resin Paints for Waterproof and Anti-Corrosion to Improve the Property of Concrete Structure (콘크리트 구조물의 표층부 내구성 증진을 위한 세라믹 메탈계 방수$\cdot$방식재 도료의 성능 평가 연구)

  • Jun Byung-Hun;Kim Jin-Sung;Kang Hyo-Jin;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.113-117
    • /
    • 2005
  • The ceramic metal resin paints for waterproof and anti corrosion is not long history in development of materials even many actual result. So far, no standard have been given to construction and maintenance method, Quality and property, it is real state that cannot afford to proper quality control in job site or production. This study has been test for the ceramic metal resin paints for water and anti corrosion, as the result, it have proper performance of job site and mechanical performance of compare to other existing. In particular, tensile strength indicates more high about $14.1N/mm^2$ than epoxy resin paints, and in elongation per unit length is more high It is shows having better adhesive strength than epoxy resin paint for crack on the concrete structure. Moreover, The ceramic metal paint for water and corrosion proofing have to have main performance is watertightness and resistance for external impact, chloride ion permeation, drinkable water elution.

  • PDF