• Title/Summary/Keyword: 방사선 해부학

Search Result 98, Processing Time 0.032 seconds

The imaging Anatomical Consideration of the Resonance of the Cranial Cavity (두개강 공명의 영상해부학적 고찰)

  • Lee, Dong-Myoung
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.29-37
    • /
    • 2000
  • Because vocal technique is the basis of singing a song beautifully, so this study was undertaken to use the scientific and correct technique in order to get much better musical expressions. Shimadzu X - ray remote control TV system was used for checking the supporting state of diaphragmatic respiration after 5, 10, 15, 20, 25 and 30 sec during phonation in the state of full inhalation between professional singer and non - professional singer. Shimadzu Magnet $nex-{\alpha}$(SMT -50CX/H) was used for examining the scattering state from the resonance of nasal cavity to that of cranial cavity on the basis of diaphragmatic respiration. The results obtained were summerized as follows : 1. The resonance of cranial cavity must be scattered by the energy of diaphragmatic respiration after gathering the foci of the fundamental 5 vowels. 2. while raising the epiglottis, the resonance of nasal cavity must be clearly in order to maintain the resonance of cranial cavity beautifully. 3. We can get musical expressions by maintaining the elasticity of diaphragmatic respiration.

  • PDF

Image Measurement on Influence from Application of Compression Band on Intravenous Urography for Urolithiasis Patient (요로결석 환자의 경정맥 요로조영 검사 시 압박 유무에 따른 영상평가)

  • Kim, Hyeong-Gyun;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.261-266
    • /
    • 2015
  • Intravenous urography (IVU) for urolithiasis is a radiologic examination to diagnosis stone in the ureter path using iodine contrast media, which is radioopacity material. The method includes compression on the upper iliac crest. The compression band prevents outlet of the contrast media through the bladder and enables easier movement to upper urinary tract. This usage depends on the policy of a hospital. Therefore, this study aimed to review and compare the characteristic of progress of contrast media either in compression and non-compression. The retrospective image measurement on 60 cases of intravenous pyelography was conducted at a hospital with the identical type and amount of contrast media as well as criteria for testing. Image measurement was limited to 5 minutes clip, which is optimal for progress of contrast media depending on usage of the compression band. Also, anatomical regions were set as following: "RP" is from renal pyramid to renal pelvis, "PL" is from renal pelvis to lumbar three endplate, and "IU" and "IL" for upper and lower parts from both iliac crests. Analysis has been conducted through the statistical method based on Fisher's Exact Test to find if there are differences of distribution with the anatomical regions with compression or no compression. It has been confirmed that there is no statistical significant difference as the video measurement on 30 cases of compression and non-compression group respectively resulted in P value of 0.580 from left and 0.711 from right (both 0.960). Therefore, it has been concluded that application of a compression band on an intravenous pyelography for urolithiasis patient does not meaningfully affect the progress of contrast media.

Evaluation of Present Curriculum for Devlopment of Dept. of Radiological Science Curriculum (방사선학과 교육과정 개선을 위한 현 교육과정 평가)

  • Kang, Se-Sik;Kim, Chang-Soo;Choi, Seok-Yoon;Ko, Seong-Jin;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.242-251
    • /
    • 2011
  • A curriculum of study demands a change as period of time and society evolve. Therefore, at this point where changes are required, this study is to analyze and evaluate the curriculums which will enhance and improve current studies as a preceding stage. The research was based on the survey by groups of education experts and 19 universities with current curriculum of study in radiologic science, and their references. The study was focused on the scope of work by radiologic technologist, change of college systems, academic research about radiologic science, and the improvement and the future of radiologic science field in perspective to globalization and the digital era. In terms of work scope, angiography and interventional radiology at 6 to 8 schools, fluoroscopy at 4 schools, ultrasound and practices at 6 schools, magnetic resonance image at 2 schools were found to be unestablished. The basic medical subjects, humuan physiology, human anatomy and practices, medical terminology courses were set up at most schools; however, pathology at 5 schools, image anatomy at 6 schools, clinical medicine at 11 schools were yet opened. Among the basic science and engineering subjects, general biology and its practices at 11 schools, general physics and its practices at 14 schools, and general chemistry and its practices at 8 schools were established which is about a half from a total number of schools. Only 4-5 schools established digital subjects such as, health computer, computer programming, PACS which are the basic major subjects. In order to provide academic improvement in radiologic science, digitalized education and globalization, and basis for future-oriented education for the field of radiologic science, including expanded scope of work, it is acknowledged that curriculums that are opened and run at each school need to be standardized. Therefore, the need for introduction of certificate for the radiologic science education courses are suggested.

Anatomic Study on the Lacrimal Duct using Computerized Tomograph

  • Choung Pill-Hoon;Lee Ui-Lyong;Hong Jong-Rak
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.5 no.2
    • /
    • pp.109-112
    • /
    • 2002
  • 구순 구개열 환자의 악교정 성형수술로 구강내 Le Fort II 골절단술이나 비중격 성형술이 많이 이용되는데, 이때 비골의 외측골절단술을 요하며, 이에 대한 술 후 합병증으로 비루관의 폐쇄나 비골의 분쇄골절 등이 발생할 수 있어, 악안면기형 환자를 다루는 구강악안면외과의사에게 비루관의 웅용해부학적 연구는 중요하다. 본 연구의 목적은 교합면을 기준으로 촬영된 컴퓨터 단충 촬영에서 비루관의 위치와 크기를 조사하는데 있다. 2000년 7월부터 2003년 2월까지 서울대학교병원 구강악안면방사선과에서 컴퓨터 단층촬영을 시행한 환자 62명을 대상으로 비상악봉합선에서 비루관까지의 최단거리와 비루관의 최대반경과 최소반경을 측정하였다. 우측비상악 봉합선에서 비루관까지의 거리는 5.68mm이고, 좌측은 5.67mm였다. 좌우 및 성별간의 차이는 없었다. 이의 해부학적 지견은 악기형 수술시의 비루관 폐쇄라는 합병증의 예방책으로 기여하리라 생각된다.

  • PDF

Anatomical Ultrastructure of Spermatozoa of Korean Sharpbelly, Hemiculter eigenmanni (Cypriniformes, Cyprinidae) (치리 Hemiculter eigenmanni 정자의 미세해부학적 구조 (잉어목, 잉어과))

  • Kim, Kgu-Hwan
    • Korean Journal of Ichthyology
    • /
    • v.31 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • The spermatozoa of Hemiculter eigenmanni is similar to other cyprinid by spherical head containing a nucleus with highly condensed chromatin, a short midpiece with mitochondria and a flagellum located tangentially to the head. The fine structure of cyprinid spermatozoa described classical characteristics of Cyprinidae spermatozoon comprising the absent of acrosome, the shallow nucleal fossa, postnuclear distribution of mitochondria and the lateral insertion of flagellum. However there were some structural differences for their morphology, in the mitochondria and the orientation of centrioles. The proxomal and distal centrioles are oriented approximately $145^{\circ}$ to each other. The mitochondria of 8 or 10 in number are arranged in two or three layers.

A Study on Variation Types in Celiac Axis and Superior Mesenteric Artery using 3D Volume Rendering of MDCT (MDCT의 3차원 볼륨렌더링을 이용한 복강축과 위창자간막동맥의 변위 형태에 관한연구)

  • Lee, Jeong-Keun;Jang, Young-Ill;Jang, Seong-Joo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.131-139
    • /
    • 2013
  • The aim of this study was to evaluate the variation which based on Celiac axis and SMA using by CT volume rendering images. 613 patients underwent abdominal CTA, there were 552 patients (99.05%, TypeI, II) with normal anatomical form and 61 (9.95%, Type III~XII) with variation. TypeI was 339(55.31%), Type II was 213 (34.74%), Type III was 18 (2.93%), Type IV was 12 patients (1.95%), Type V was 11 patient (1.79%), Type VI was 9 patients (1.46%), Type VII was 6 patients (0.97%), Type VIII was 1 patient (0.16%), Type IX was 1 patient (0.16%), Type X was 1 patient (0.16%), Type XI was 1 patient (0.16%), and Type XII was 1 patient (0.16%) into totally new types of variation. In conclusion, we could found 9 new types of variation by classifying based on celiac axis and superior mesenteric artery. These results were considered to be an important opportunity for a new vessel map.

Recent updated diagnostic methods for esophageal motility disorders (식도의 운동장애에 관한 최신지견)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.11-16
    • /
    • 2004
  • Classification of esophageal motility disorders not yet finalized and is still ongoing as the new disorders are reported, and the existing classification is changed or removed. In terms of radiology, the primary peristalsis does not exist, and the lower end of the esophagus show the smooth, tapered, beak-like appearance. The esophageal motility disorder, which mostly occurs in the smooth muscle area, show the symptoms of reduction or loss (hypomotility) or abnormal increase (hypermotility) of peristalsis of the esophagus. It is important to understand the anatomy and physiology of the esophagus for the appropriate radiological method and diagnosis. Furthermore, the symptom of the patient and the manometry finding must be closely referred for the radiological diagnosis. The lower esophageal sphincter can be normally functioning and open completely as the food moves lower. Sperandio M et al. argues that the name diffuse esophageal spasm must be changed to distal esophageal spasm (DES) as most of the spasm occurs in the distal esophagus, composed of the smooth muscle. According to Ott et al., usefulness of barium method for diagnosing the esophageal motility disorder is Achalasia 95%, DES 71% and NEMD 46%, with the overall sensitivity of 56%. However, excluding the nutcracker esophagus or nonspecific disorder which cannot be diagnosed with the radiological methods, the sensitivity increases to 89%. Using videofluoroscopy and 5 time swallows, the average sensitivity was over 90%. In conclusion, the barium method is a simple primary testing method for esophageal motility test. Using not only the image but also the videofluoroscopy with good knowledge of the anatomy and physiology, it is believed that the method will yield the accurate diagnosis.

  • PDF

The Imaging Anatomical Consideration about Effects of Respiratory Disease on the Breath Control and Resonance in Vocal Technique (발성기법중 호흡기 질환이 호흡조절과 공명에 미치는 영향에 관한 영상해부학적 고찰)

  • Lee, Dong-Myoung
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.41-47
    • /
    • 2001
  • This study was undertaken to examine the differences between normal vocal technique and abnormal vocal technique because of diseases in respiratory system(emphysema). The breath control for vocalizing with diaphragmatic respiration must be sustained clearly. But if there is an abnormality in lung(emphysema), it is not sustained to hold diaphragmatic respiration when we sing. In order to examine the differences of the width in diaphragmatic respiration among professional singer's case, non professional case and the case of respiratory disturbance, Shimadzu X-ray remote control TV system was used. The results obtained were summerized as follows: When we vocalize, breath control is very important not only to sustain a resonance but also to form focus for being scattered to cranial resonance. We must know the differences between normal and abnormal diaphrogmatic respiration in order to teach vocal technique right. professional singer's vocal technique with Piaphragmatic respiration was better than that compared with non professional case and respiratory disturbance. Non professional case was very similar to the case of respiratory disturvance in diaphragmatic respiration until 10 sec. after full inhalation, but diaphragmatic respiration in the case of 20 sec. after full inhalation was very different.

  • PDF

A STUDY ON THE ERRORS UN THE CEPHALOMETRIC MEASUREMENTS (두부방사선사진의 계측오류에 관한 연구)

  • Na, Kwang-Cheon;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.75-83
    • /
    • 1998
  • This study was done to recognize the importance of errors in measurements of cephalometric radiograph and to find the anatomical structures those need special care to select as a reference points through the detection of the systematic errors and estimation of random errors. For this purose, 100 cephalometric radiographs were prepared by usual manner and 61 reference points, and 130 measurement variables were established. Measurement errors were detected and estimated by the comparison of the 25 randomly-selected samples for repeated measurements with the main sample. The following results were obtained : 1. In comparison of the repeated measurements, there were statistical significant differences in 24 variables which were 18.4% of 130 total variables. 2. The frequency of the difference in identification of the reference points between the repeated measurements was very high in the root apex of upper incisor(as), the most posterior wall of maxilla(tu), soft tissue nasion(n'), soft tissue frontal eminence(ft), and ad3 in airway. 3. After correction of reference points marking until the level of below 5% significance, the range of random errors were from 0.67 to 1.71 degree or mm. 4. The variable shown the largest random error was the interincisal angle(ILs-ILi). 5. Measurement errors were mainly caused by the lack of precision in anatomic definitions and obscure radiographic image. From the above results, the author could find the high possibility of errors in cephalometric measurements and from this point, we should include error analysis in all the studies concerning measurments. In is essential to have a concept of error analysis not only for the investigator but also for a reader of other articles.

  • PDF

Application of Dual Tree Complex Wavelet for Performance Improvement of CT Images (CT 영상의 화질개선을 위한 이중트리복합웨이블릿의 적용)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.941-946
    • /
    • 2019
  • Computed tomography (CT) has been increasing in frequency and indications for use in clinical diagnosis and treatment decisions. Multidetector CT has the advantage of shortening the inspection time and obtaining a high resolution image compared to a single detector CT, but has been pointed out the disadvantage of increasing the radiation exposure. In addition, when the low tube voltage is used to reduce the exposure dose in the CT, noise increases relatively. In the existing method, the method of finding the optimal image quality using the method of adjusting the parameters of the image reconstruction method is not a fundamental measure. In this study, we applied a double-tree complex wavelet algorithm and analyzed the results to maintain the normal signal and remove only noise. Experimental results show that the noise is reduced from 8.53 to 4.51 when using a complex oriented 2D method with 100kVp and 0.5sec rotation time. Through this study, it was possible to remove the noise and reduce the patient dose by using the optimal noise reduction algorithm. The results of this study can be used to reduce the exposure of patients due to the low dose of CT.