• Title/Summary/Keyword: 방사선 투과촬영

Search Result 84, Processing Time 0.031 seconds

An Application of Dynamic Radioscopy Technique to Static Firing Test (동적 방사선투과검사를 이용한 지상연소시험 기술개발)

  • Lim, Soo-Yong;Kim, Jun-Yeop;Kim, In-Sik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.3
    • /
    • pp.32-40
    • /
    • 2006
  • Dynamic Radioscopy technique was developed to observe internal phenomena of motors during firings. For use of this technique, generator and image box consisting of conversion screen, mirror, and video camera were designed and fabricated at our laboratory, and static firing tests were conducted to small motors. Protection devices against vibration and noise induced from during combustion were also made and their performances were evaluated with reference to the vibration criteria. Test results have shown that the vibration levels at concerned points were measured less than vibration criteria, and the internal phenomena during firings were also observed clearly.

Imaging Feature of Radiation Induced Lung Disease (방사선 폐손상의 방사선학적 소견)

  • Lee, Jae Gyo;Rho, Byeung Hak;Chang, Jae Chun;Kim, Myung Se
    • Journal of Yeungnam Medical Science
    • /
    • v.17 no.2
    • /
    • pp.146-154
    • /
    • 2000
  • Background and Purpose: Radioopaque lesions are commonly seen in patients who received thoracic radiotherapy for various kinds of thoracic neoplasm, But therir exact diagnos are sometimes uncertain. Patients and Methods: We examined simple chest radiograph and computed tomogram(CT) of 69 patients who received thoracic radiotherapy for lung cancer and were follow up at least 6 months in Yeungnam University Medical Center. Results: Of the 69 patients. thirty-eight patients showed radioopaque lesions in their chest radiographs except radiation fibrosis; radiation pneumonitis was witnessed in 24 patients. infectious pneumonia in 8 patients, and recurrence in 6 patients. In radiation pneumonitis patients, the pneumonitis occurred usually between 50 to 130 days after receiving radiation therapy, and interval between pneumonitis and fibrosis is 21 to 104 days. Simple chest radiographs of radiation pneumonitis(24 patients) represented ground glass opacities or consolidation in 4 cases(type I, 17%), reticular of reticulonodular opacities in 10 cases(type II, 42%), irregular patchy consolidations in 2 cases( type III, 8%), and consolidation with fibrosis in 8 cases(type IV, 33%), CT represent ground glass opacities or consolidation in 5 cases(type I, 29%), irregular nodular opacities in 3 cases(type II, 19%), irregular opacity beyond radiation fields in 3 cases(type III, 18%), and consolidation with fibrosis in 6 cased(type IV, 35%). The CT of four patients who represented type II on simple chest radiographs reveal type I and III, and CT of two patients with clinical symptoms who had no abnormal finding on simple radiograph revealed type I. Conclusions: In conclusion, computed tomogram is superior to the simple radiograph when trying to understand the pathologic process of radiation pneumonitis and provide confidence in the diagnosis of radiation induced lung disease.

  • PDF

Early Stage Legg-Calve-Perthes Disease in a Dog: Clinical, Surgical, Radiological, Computed Tomography and Histological Findings (초기 허혈성 대퇴골두 괴사증을 보이는 개에서 임상학적, 수술적, 방사선학적, 컴퓨터단층촬영, 조직학적 소견)

  • Thak, Min-Ae;Yoon, Hun-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.30 no.5
    • /
    • pp.366-370
    • /
    • 2013
  • A 7-month-old Pomeranian presented with non-weight bearing lameness on the right pelvic limb. Physical examination revealed pain on extension of the right hip joint, and serum chemistry results showed an increased concentration of creatine kinase. Radiographic findings at admission included a weak radiolucent line on the right femoral head and widening of the right hip joint space, and mild displacement of the right capital femoral epiphysis was additionally identified on day 14. Computed tomography (CT) showed a decreased Hounsfield Unit measurement and a fracture line on the right femoral head. Early stage Legg-Calve-Perthes disease (LCPD) was diagnosed and femoral head and neck ostectomy was performed on the right femur. A fracture fissure and osteophytes at the epiphyseal plate of the femoral head were identified surgically. Necrosis in the femoral metaphysis and epiphysis was observed histologically. This case report describes the radiography, CT images, and surgical and histological findings in a dog with early stage LCPD.

Usefulness of Application of Tube Voltage Changes to Reduce Patient Dose during Abdominal CT Follow up (반복적인 복부 컴퓨터단층촬영 시행 시 환자선량 감소를 위한 관전압 변화 적용의 유용성)

  • Yoon, Joon;Kim, HyeonJu
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.293-299
    • /
    • 2021
  • In order to reduce the irresistible radiation exposure of patients who perform periodic examinations using a CT among various scan parameters a method to reduce patient dose was investigated through changes in the tube voltage close to X-ray penetrating power. As a result of the experiment 100 kVp was applied instead of 120 kVp which is commonly used in clinical practice and CTDI decreased by about 41% during scan. In addition the degree of change in image quality was measured as 1046.1±3.7 HU for CT value and 71.4±7.9 for Pixel value and statistical analysis showed no significant difference (0.05

A Study on Compression Paddle Materials to Reduce Radiation Exposure Dose During Mammography; PC and PMMA and Carbon (유방촬영 시 피폭선량을 줄이기 위한 압박대 재질의 PC, PMMA, Carbon에 대한 연구)

  • Hong, Dong-Hee;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.81-87
    • /
    • 2015
  • This study was designed the band material in order to reduce the exposure pressure of the breast and the material was measured of Radiolucent and radiation properties with a radiation materials of PC, PMMA, Carbon. Also the image quality by image analysis to obtain the following results are below: Unfors Xi dosimetry using radiation transmittance when the results of 8.353mGy is measured after removal of the cuff, the PC 6.308mGy, PMMA 6.223mGy, Carbon 7.218mGy were measured respectively. Semi-layer PC 0.375mmAl, PMMA 0.370mmAl, with Carbon 0.360mmAl Carbon, PC, PMMA was higher radiation properties and transparency in order. InLight / OSL NanoDotTM dosimeter was used in the cuff and then removed by placing the dosimeter measured results center on 1.143mGy, at the edge 12.56mGy, on the central PC 8.990mGy, at the edge 10.291mGy, PMMA center on 8.391mGy, the edge 9.654mGy, on Carbon center 9.581mGy, 11.313 mGy were measured at the edge of Carbon, PC, PMMA showed a high permeability in order. Image Pixel average J is then removed from the cuff 976.655, PC 831.032, PMMA 819.069, Carbon 897.118 Carbon, PC, PMMA was measured by high order.

Benign Tumor-Like Developmental Salivary Gland Defect (양성 종양과 유사한 형태를 가진 발육성 타액선 골결손)

  • An, Seo-Young;Kim, Yong-Gun;Jung, Jae-Kwang
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.301-307
    • /
    • 2012
  • 50-year-old female and 50-year-old male were referred to the department of the oral and maxillofacial surgery of Kyungpook national university dental hospital with asymptomatic lesions on their posterior mandibular body areas. They were discovered incidentally on panoramic radiographs during routine dental examination. Physical examination revealed no remarkable findings. Each panoramic radiograph showed well defined radiolucent lesions without hyperostotic border on their posterior mandibular body area. At first they were diagnosed as benign tumors because they looked like multilocular pattern and one of the patient showed discontinuity of mandibular canal within the lesion. CT scans demonstrated well demarcated and irregular lingual depression filled with fat tissue and they were diagnosed as developmental salivary gland defects. One of the lesion showed no change on follow-up panoramic radiograph after 4 months. Developmental salivary gland defects resembling benign tumor are atypical cases and it is suggested that confirmatory imaging using CT or MRI should be taken.

Physical properties of a new resin-based root canal sealer in comparison with AH Plus Jet (새로운 레진계 근관실러와 AH Plus Jet의 물성 비교)

  • Thu, Myint;Kim, Jin-Woo;Park, Se-Hee;Cho, Kyung-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.80-87
    • /
    • 2017
  • Purpose: The aim of this study was to assess the physical properties of a novel resin-based endodontic sealer, Any-Seal, in comparison with AH Plus Jet. Materials and Methods: Flow, radiopacity and compressive strength were examined according to ISO 6876/2001. For flow test, 0.05 mL of sealer was placed between glass plate and 100 g weight were applied. Ten minutes after mixing the sealers, the load was removed and the diameters of the compressed sealer discs were measured. For radiopacity, 10 mm diameter and 1 mm thickness sample were fabricated and took radiograph with an aluminum step-wedge and analyzed using imaging program. For compressive strength test, $4mm{\times}6mm$ cylindrical specimen was fabricated and tested after 24 hours and 1 week using Universal testing machine. Results: Both tested sealers were consistent with ISO 6876/2001 in the flow and radiopacity test. The flow values of both sealers were not significantly different (P > 0.05). AH Plus Jet had significantly higher radiopacity (P < 0.05). AH Plus Jet showed higher compressive strength at both time intervals (P < 0.05). Conclusion: Any-Seal showed low compressive strength until after 1 week, so its physical and biological aspect should be evaluated more before clinical use.

Evaluation of the radiopacity and cytotoxicity of resinous root canal sealers (레진계 근관충전실러의 방사선 불투과성 및 세포 독성에 대한 평가)

  • Kim, Chang-Kyu;Ryu, Hyun-Wook;Chang, Hoon-Sang;Lee, Byung-Do;Min, Kyung-San;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.5
    • /
    • pp.419-425
    • /
    • 2007
  • The aim of this study was to evaluate the radiopacity and cytotoxicity of three resin-based (AH 26, EZ fill and AD Seal), a zinc oxide-eugenol-based (ZOB Seal), and a calcium hydroxide-based (Sealapex) root canal sealers. Specimens, 10 mm in diameter and 1 mm in thickness, were radiographed simultaneously with an aluminum step wedge using occlusal films, according to ISO 6876/2001 standards. Radiographs were digitized, and the radiopacity of sealers was compared to the different thicknesses of the aluminum step wedge, using the Scion image software. Using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, the cytotoxicity of each material was determined in immortalized human periodontal ligament (IPDL) cells. The results demonstrated that EZ fill was the most radiopaque sealer, while Sealapex was the least radiopaque (p < 0.05). AH 26, AD Seal and ZOB Seal presented intermediate radiopacity values. All the materials evaluated, except for Sealapex, presented the minimum radiopacity required by ISO standards. The cell viabilities of resin-based root canal sealers were statistically higher than that of other type of root canal sealers through the all experimental time. Further, EZ fill showed statistically lower cell viability in 24 and 48 hours compared to AD Seal and in 72 hours compared to all other resin-based root canal sealers. However, there was no correlation between the radiopacity and cytotoxicity of three resin-based root canals sealers (p > 0.05). These results indicate that resin-based root canal sealer is more biocompatible and has advantage in terms of radiopacity.

Improvement of shieldability and lightweight of radiation protective apron (방사선 방호용 에이프런의 경량화와 차페능 개선)

  • Kim, Chang-Bok;Kim, Young-Keun;Ku, Hal-Bon;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.105-110
    • /
    • 2004
  • 방사선 투시조영 촬영 시 사용되는 방호복의 차폐효율 증가와 경량화는 오랜 시간 연구 대상이 되었다. 이러한 방호복의 질적 향상을 위하여 연구한 결과는 다음과 같다. Apron의 규격인 납 당량 0.25mm에 해당하는 투과선량은 5.2%로 나타났으며, 시료 Sn, Ni, Ti, Cu의 방사선 차폐 효율은 Sn이 가장 높게 나타났다. 증착시료 Sn+Pb 방법에서는 Sn 0.18mm와 Pb 0.1mm, Pb+Sn 방법에서는 Pb 0.1mm와 Sn 0.36mm에서 Apron의 규격인 납 0.25mm 두께로 나타났다. 증착시료 Sn+Pb는 Apron의 규격인 0.25mm 납 당량보다 차폐효율이 높고, 면적당 무게가 가벼워 방호복 물질로 적합한 것으로 사료된다.

  • PDF

The development of digital camera for the medical DF instrument (의료용 DF 장비의 디지털 카메라 개발)

  • 김용민;이성운;구기현;김진용;김승식;문지영
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.76-77
    • /
    • 2003
  • Digital Radiograpy & Fluoroscopy(DRF 또는 DR 또는 DF)는 cone beam을 이용하여 인체를 투과한 X선을 영상증배관(Image Intensifying Tube: IIT)을 통하여 가시광선으로 변환시킨 후 영상을 카메라로 보내고, 이곳에서 발생한 영상정보를 디지털로 처리하여 모니터를 통해 눈에 보이는 영상으로 만드는 방법으로 IIT에 기초한 디지털 방사선 촬영술이라고도 한다. DF 방법은 즉시 영상 표시와 진단이 가능하기 때문에 즉시성이 요구되는 심장이나 두복부 등의 순환기 분야에서 DSA(Digital Subtraction Angiography) 장비로 이용되고 있고, 순환기뿐만 아니라 위를 중심으로 한 소화관(식도, 위, 소장, 대장, 직장)의 분야에서 적용 가능하다. (중략)

  • PDF