• Title/Summary/Keyword: 방사선 사용 분야

Search Result 190, Processing Time 0.027 seconds

Investigation of Knowledge and Awareness of Radiation of University Students - To the Radiation Non-Commissioned Personnel - (대학생의 방사선의 지식 및 인식 조사 - 방사선 비전공자를 대상으로 -)

  • Kang, Yeon-Hee;Park, Cheolwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.233-239
    • /
    • 2019
  • The purpose of this study was to investigate the knowledge and awareness about radiation use among non - radiation undergraduates. This analysis were used based on the collected questionnaires with Frequency, mean and standard deviation, t-test, one-way ANOVA. As a result, there was no significant difference between the groups in terms of gender and age. There were statistical differences in some items in the major field. In addition, the perception of radiation was more negative in women and under 25 years of age (p<0.05). The correlations between the sub - factors showed that the higher the knowledge of radiation, the higher the perception of knowledge and use of radiation. It is believed that university students will have a positive effect of contributing to the development of the radiation industry if they have a correct understanding of radiation because they are more likely to contribute to public opinion by advancing into society.

정책 - 2018 원자력연구개발사업 시행 계획

  • 한국원자력산업회의
    • Nuclear industry
    • /
    • v.38 no.3
    • /
    • pp.11-34
    • /
    • 2018
  • 국민의 생명 안전 중심의 미래지향적 원자력 방사선 기술 개발을 목적으로 하는 2018년도 원자력연구개발사업의 세부사업별 시행계획이 확정되었다. 과학기술정보통신부는 이번 시행계획에 들어가 있는11개 단위 사업 추진을 위해 원자력연구개발기금 1,278억원, 일반회계 및 지역발전특별회계 813억원 등 총2,091억원을 투입할 예정이다(년도 2,335억원, 10.5% 감소) 지원 분야는 크게 원자력 기술, 방사선 기술, 기초 기반 구축으로 나누어진다. 원자력 기술 분야는 원자력 안전 연구, 원전 해체 기술, 사용후핵연료 관리 기술 및 중소형 원자로 개발 등이며, 방사선 기술 분야는 방사선 기술 고도화를 통한 핵심 기술 개발, 대형 의료 산업용 방사선 시설 장비 구축 등에 방점을 찍고 있다. 그리고 기초 기반 구축 분야는 선진기술연구센터, 국제 협력, 인력 양성 등 연구 기반 확충에 역점을 두고 있다. 2018년도 중점 추진 방향과 사업별 세부 추진 계획은 다음과 같다.

  • PDF

Estimation for Economic Scale of Radioactive Usage in Korea using Input-Output Table 2005 (2005년 산업연관표를 이용한 우리나라의 방사선 이용의 경제규모에 대한 추정 연구)

  • Kim, Yoon-Kyung
    • Journal of Korea Technology Innovation Society
    • /
    • v.13 no.4
    • /
    • pp.772-793
    • /
    • 2010
  • In this paper, author estimated economic scale of radiation usage in Korea using Input-Output table 2005 and other micro data published. This estimation focused all kind of radiation usage in whole economic activity. Estimation of economic scale is quantitative analysis for how much radiation usage increase productivity and welfare. Economic scale estimation of radiation usage in Korea 2005 is 6,297 Billion Won and it occupies 0.74% of GDP. It is smaller level compared with that of US and Japan. It is 1.5% of GDP in US (1997) and 1.2% of GDP in Japan (2005). Radiation usage in industrial sector is 5,775 Billion Won and it is 0.68% of GDP. Radiation usage in agriculture sector is 171 Billion Won and it is 0.02% of GDP. Radiation usage in medical sector is 351 Billion Won and it is 0.04% of GDP. This implied that radiation usage in industrial sector is larger than other sector. Use of medical radiology may be enlarge in the future due to population structure. The result that radiation usage occupied 0.74% of GDP arouse contribution of radiation usage in daily life. It helps people to have more understanding and public acceptance for radiation.

  • PDF

Study on the Decommissioning of Small Nuclear Facility through Analyzing Foreign Decommissioning Practices (국외 해체 사례 분석을 통한 국내 소규모 방사선이용시설 해체에 관한 연구)

  • Kwon, Dayeong;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.125-130
    • /
    • 2015
  • RI & RG are used in various field such as medical field, industrial field, agricultural and food&life field. The number of small nuclear facilities is on the increase. We need to take an interest in decommissioning of small nuclear facility and predict the occurring problem from facility decommissioning. Because of the relatively low radiation risk, the preparation of the small nuclear facility dismantling is often neglected. As the accident in Goiania, Brazil showed, the impact of the decommissioning of small nuclear facilities is not less than the large nuclear facilities although it may seem dangerless. Therefore, we analyzed the each institutional characteristics of the decommissioning of small nuclear facilities through foreign case study on this research. Also, we proposed several considerations on decommissioning such as reuse of facility and source, lack of space, stakeholder involvement and failures of protection. Through these study, we tried to make guideline of the small nuclear facilities decommissioning.

Dose and Image Evaluations of Imaging for Radiotherapy (방사선치료를 위한 영상장비의 선량 및 영상 평가)

  • Lee, Hyounggun;Yoon, Changyeon;Kim, Tae Jun;Kim, Dongwook;Chung, Weon Kyu;Park, Sung Ho;Lee, Wonho
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.292-302
    • /
    • 2012
  • The patient dose in advanced radiotherapy techniques is an important issue. These methods should be evaluated to reduce the dose in diagnostic imaging for radiotherapy. Especially, the Computed Tomography in radiotherapy has been used widely; hence the CT was evaluated for dose and image in this study. The evaluations for dose and image were done in equal condition due to compare the dose and image simultaneously. Furthermore, the possibility of dose and image evaluations by using the Monte Carlo simulation MCNPX was confirmed. We made the iterative reconstruction for low dose CT image to elevate image quality with Maximum Likelihood Expectation Maximization; MLEM. The system we developed is expected to be used not only to reduce the patient dose in radiotherapy, also to evaluate the overall factors of image modalities in industrial research.

Monte Carlo simulation of the electronic portal imaging device using GATE

  • Chung, Yong-Hyun;Baek, Cheol-Ha;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.3
    • /
    • pp.11-16
    • /
    • 2007
  • In this study, the potential of a newly developed simulation toolkit, GATE for the simulation of electronic portal imaging devices (EPID) in radiation therapy was evaluated by characterizing the performance of the metal plate/phosphor screen detector for EPID. We compared the performances of the GATE simulator against MCNP4B code and experimental data obtained with the EPID system in order to validate its use for radiation therapy.

  • PDF

볼륨렌더링을 이용한 3차원 물체의 형상화

  • 최환수
    • 전기의세계
    • /
    • v.41 no.9
    • /
    • pp.48-52
    • /
    • 1992
  • 본 글에서 구미에서 활발히 실용화 되고 있는 volumetric rendering 기술을 간략히 소개하고자 한다. 특히 이기술은 volumetric dataset을 쉽게 구할 수 있는 진단방사선과에게 활발히 실용화를 연구하고 있으며 최근에는 몇 대규모 병원에서 surgical planning을 위한 임상에도 사용하기 시작하였으며 향후 암환자의 방사선치료, 신경외과의 stereotaxic surgery등으로 그 활용 범위를 넓히기위해 많은 연구를 할 수 있는 모든 분야에 적용이 가능하다. 특히 등고선 data를 이용한 지형의 형상화는 군사적 용도로 긴요하게 쓰일 수 있다.

  • PDF

Removal of metal ions during permeatin across the ion-exchange porous membrane (다공성 이온 교환막의 투과법에 의한 금속이온의 제거)

  • Jung, Kum-yeun;Kim, min
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.130-132
    • /
    • 1998
  • 정밀여과막(MF)막은 $0.1~1\mum$정도의 공경을 가지고 있는 막으로 산업이나 생활분야에서 널리 사용되고 있다. 이러한 정밀여과막에 이온교환기를 부여 시키므로써, 필요로하는 금속이온이나 단백질을 흡착할 수 있는 기능성 분리막이 제조 가능하다. 방사선프라프트 중합법은 고분자를 개질, 수식 또는 기능화시키는 수법으로 사용되고 있다. 본 실험에서는 방사선그라프트중합법을 사용하여 폴리에틸렌 정밀여과막에 에폭시기를 가지는 glycidyl methacrylate(GMA)를 그라프트 중합시킨 후 이온 교환기를 도입하여, 얻어진 막의 특성에 대해 고찰하였다. 본실험의 목적은 다음과 같다. (1) 폴리에틸렌 정밀여과 막에 방사선그라프트 중합법을 사용하여 이온교환기를 도입시키는 반응조건을 검토한다. (2) 도입된 이온교환기에 다른 막의 투과 성능을 조사한다. (3) 투과법에 의한 금속이온의 흡착성능을 조사한다. 여기서, 이온교환기로서는 술폰산(sodium sulfite:$SO_3H$)을 사용하였다.

  • PDF

Definition and Difference between Dose Equivalent and Equivalent Dose in Radiation Dose Measurement and Evaluation (방사선량의 측정, 평가에서 선량당량(dose equivalent)과 등가선량(equivalent dose)의 정의 및 차이)

  • Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 1993
  • In its recent recommendation No. 60(1990), ICRP has newly introduced several terminology which had not existed in its prior recommendation No. 26(1977). Of these, a newly defined quantity 'Equivalent Dose' replacing the 'Dose Equivalent' of the ICRU concept has been recommended to be adopted in the radiation protection programme. However, since the committee still uses the 'Dose Equivalent' and 'Equivalent Dose' in its several publications, it is likely to provoke unnecessary confusions and misuses in applying these two quantities. In this paper were described the definition and difference between these two quantities to help in understanding of these two quantitites among the person involved in the radiation protection activities.

  • PDF

THE USE OF POSTEROANTERIOR CEPHALOGRAM IN ORTHODONTICS (교정에서의 정모 두부 방사선 규격 사진의 이용)

  • Kim, Young Joon;Rhu, Young Kyu
    • The korean journal of orthodontics
    • /
    • v.19 no.2
    • /
    • pp.165-175
    • /
    • 1989
  • In evaluation of some area within the craniofacial complex posteroanterior cephalogram together with lateral cephalogram is used for assessment of the exact existence and posture by grasping 3-dimensional concept. The usages of posteroanterior cephalogram in orthodontics are following; 1. The use during diagnosis and treatment planning 1) Assessment of the area and amount of facial asymmetry. 2) Assessment of therapeutic position for diagnosis and treatment 2. The Assessment of success in orthodontic mechanics If we use posteroanterior cephalogram together with lateral cephalogram adequately and simultaneously we can establish the exact diagnosis and appropriate treatment planning.

  • PDF