• Title/Summary/Keyword: 방사선 방어효과

Search Result 206, Processing Time 0.025 seconds

Neutron Reflecting Effects by Water and Concrete (물과 콘크리트에 의한 중성자(中性子)의 반사효과(反射效果))

  • Min, Duck-Kee;Ro, Seung-Gy
    • Journal of Radiation Protection and Research
    • /
    • v.8 no.1
    • /
    • pp.33-37
    • /
    • 1983
  • Neutron reflecting effects in terms of effective multiplication factor have been calculated with varying water or concrete thickness, and gap distance between concrete reflector and a fissile solution system. A numerical calculation of effective multiplication factors has been carried out by using the discrete ordinates method with the help of the computer code, ANISN. It is revealed that the reflecting .effect by thin concrete is lower than that of the identical thickness of water while the effect by thick water is low compared to that of the identical thickness of concrete. It seems that the effective multiplication factors are first decreasing rapidly with gap distance, which is filled with water, between concrete reflector and the fissile solution system, and then decrease slowly over the distance of about 15cm.

  • PDF

An Experimental Study on Radioprotective Effect of DDC, MEA, and WR-2721 (DDC, MEA, WR-2721의 방사선(放射線) 방호효과(防護效果)에 관(關)한 연구(硏究))

  • Chung, In-Young;Koh, Joo-Hwan;Chung, Hyun-Woo;Chil, Soo-Yil;Yoo, Seong-Yul;Koh, Kyoung-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.2
    • /
    • pp.114-122
    • /
    • 1986
  • At present, the treatments of the radiation-induced diseases are only performing by the palliative treatment technique. Moreover, radiation protective agents are a little toxic for human being and this seriously limits their applicability with various complications in clinical uses. Accordingly, as a part of the aim of gain of the basic data for protective roles of some radioprotectors, the present investigation was carried out to evaluate the comparative radioprotective effects by the administration of DDC, MEA, WR-2721. Results are shown for statistically significant analysis and correlation with each group as follows; 1. The proper doses of the radioprotectors were DDC; 1,550 mg/kg, MEA; 450 mg/kg, WR-2721; 780 mg/kg of the mouse body weight. 2. DMF(Dose modification factor) of LD 50/10 and LD 50/30 for whole body irradiation was DDC; 1.2, MEA; 1.4, WR-2721; 1.9 and DDC; 1.7, MEA; 1.8, WR-2721; 2.5 respectively. 3. DMF for radiation reaction of jejunal crypt was DDC: 1.07, MEA: 1.21 and WR-2721: 1.76 and that of jejunal crypt cell was DDC: 1.04, MEA: 1.08 and WR-2721: 1.38 respectively. 4. Conclusively, WR-2721 was the most effective drung among the three radioprotectors and this result must be a supportive data for further study for clinical application.

  • PDF

Exposure Measurements of Co-60 Gamma rays (Co-60 감마선의 조사선량 측정)

  • Hah, Suck-Ho;Kim, Hyun-Moon
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.7-16
    • /
    • 1991
  • Measurement of Co-60 gamma rays has been made for establishment of exposure standard and analyze it's overall uncertainties. Exposure rate determined by the charge mode method using vibrating reed amplifier with cylinderical type cavity chamber. The values of a variety of physical constants and the correction factors are evaluated. The resulting exposure rate is 690.81 R/h at the distance of 1m from the source and the related uncertainties is ${\pm}0.8%$

  • PDF

Target motion analysis of the respiratory gated guided radiotherapy in liver cancer patients using 4D-CT (4D-CT와 호흡동조시스템을 이용한 간암 환자의 방사선치료 표적 움직임 분석)

  • Dong, Kyung-Rae;Park, Byung-Soo;Kim, Sae-Sark;Kweon, Dae-Cheol;Goo, Eun-Hoe;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.63-68
    • /
    • 2010
  • The ultimate goal of radiation treatment is to use enough radiation dosage in order to examine a tumor while protecting normal tissue. Respiratory guided radiotherapy is being clinically implemented to examine a given stabilized area in order to compensate for the problems of patient breathing. This study investigates the effects of breathing movements on 40 patients with liver cancer through the actual radiation therapy plan using 4D-CT and respiratory guided radiotherapy using RPM. Using a commercial RPM respiratory gating system 4D-CT, we acquired 4D CT on multislice helical CT scanners that use different approaches to 4D CT image reconstruction. The results from analyzing forty patients according to age and direction showed no relationship between gender and transition change. The mean left-right, anteroposterior, and craniocaudal total movements were $3.19{\pm}1.29$, $5.44{\pm}2.07$, and $12.54{\pm}4.70$ mm, respectively. Changes were the largest with CC directions and as patients advanced in age, movements were larger. Therefore, as changes occur in treatment areas because of movements caused from breathing, respiratory gating system is put into operation to revise movement and can increase the radiotherapeutics effects in treating liver cancer.

Development of a Portable Device Based Wireless Medical Radiation Monitoring System (휴대용 단말 기반 의료용 무선 방사선 모니터링 시스템 개발)

  • Park, Hye Min;Hong, Hyun Seong;Kim, Jeong Ho;Joo, Koan Sik
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.3
    • /
    • pp.150-158
    • /
    • 2014
  • Radiation-related practitioners and radiation-treated patients at medical institutions are inevitably exposed to radiation for diagnosis and treatment. Although standards for maximum doses are recommended by the International Commission on Radiological Protection (ICPR) and the International Atomic Energy Agency (IAEA), more direct and available measurement and analytical methods are necessary for optimal exposure management for potential exposure subjects such as practitioners and patients. Thus, in this study we developed a system for real-time radiation monitoring at a distance that works with existing portable device. The monitoring system comprises three parts for detection, imaging, and transmission. For miniaturization of the detection part, a scintillation detector was designed based on a silicon photomultiplier (SiPM). The imaging part uses a wireless charge-coupled device (CCD) camera module along with the detection part to transmit a radiation image and measured data through the transmission part using a Bluetooth-enabled portable device. To evaluate the performance of the developed system, diagnostic X-ray generators and sources of $^{137}Cs$, $^{22}Na$, $^{60}Co$, $^{204}Tl$, and $^{90}Sr$ were used. We checked the results for reactivity to gamma, beta, and X-ray radiation and determined that the error range in the response linearity is less than 3% with regard to radiation strength and in the detection accuracy evaluation with regard to measured distance using MCNPX Code. We hope that the results of this study will contribute to cost savings for radiation detection system configuration and to individual exposure management.

Effects of low dose gamma irradiation on the germination and physiological activity of old red pepper ( Capsicum annuum L.) seed (묵은 고추종자의 발아와 생리활성에 미치는 저선량 방사선조사 효과)

  • Kim, Jae-Sung;Back, Myung-Hwa;Lee, Hae-Youn;Lee, Young-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.409-415
    • /
    • 2001
  • To observe the stimulating effects of low dose gamma radiation on the germination and physiological activity of germinating seeds of old red pepper (Capsicum annuum L. cv Jokwang and cv. Hongkwang), seeds were irradiated at the dose of $2{\sim}50 Gy$. The germination rate of irradiation group was higher than that of the control. Especially it was highest at the early stage of induction. The germination rate at 7 days after sowing in Jokwang and Hongkwang cultivar was high as 74% and 11% at 4 Gy and 8 Gy irradiation group, respectively. The seedling height of Jokwang cultivar was noticeably high at 4 Gy irradiation group and that of Hongkwang cultivar at 8 Gy irradiation group. The protein contents of seedlings from seeds irradiated with low dose gamma radiation of Jokwang cultivar increased at the late stage of induction and that of Hongkwang cultivar at the early stage of induction. Catalase and peroxidase activities of seedlings from seeds irradiated with low dose gamma radiation of Jokwang cultivar increased at 4 Gy irradiation group and that of Hongkwang cultivar at 8 Gy irradiation group.

  • PDF

Development of International Education and Training Program for Building Practical Competence in Radiation Protection (방사선방호 실무역량 강화를 위한 국제 교육훈련 과정 개발)

  • Kim, Hyun Kee;Son, Miyeon;Ko, Han-Suk
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Education and training is an important means of promoting safety culture and enhancing the level of competence of radiation worker in radiation protection. The existing international nuclear education and training of short duration has been carried out on the high-level officials and focussed on the classroom based training. The developing countries has been asking for support to cultivate their own technical experts to Korea which is a donor country exporting nuclear power plants. This paper summarizes the results of developing and operating the international education and training course to froster technical experts in radiation protection that emphasized practical training sessions and technical visits using the excellent domestic radiation facilities and infrastructure of education and training. It mentions the procedures of assessment and feedback as well. In an effort to maximize teaching-learning effects and to maintain consistency of the learning objectives, methods and assessment, SAT methodology has been applied on the processes of developing and operating the course. In the comparative and final assessment which were conducted at the beginning or at the end of training course, participants' average score increased around 2 points. The questionnaire of participants showed a high level of satisfaction of 4.0 points or above for the most of the questions. These imply teaching-learning methods applied to it might be effective. The teaching-learning methodologies may provide the opportunity to develop the customized training course for bringing up international technical experts and to shift educational paradigm from theory-oriented to on-site practice-based education.

Comparison of Mutant Frequencies Induced by ${\gamma}$-radiation and Pentachlorophenol at hprt Locus in Human T-lymphocytes(I) (인체 T-림프구 hprt 유전자에서 방사선 및 pentachlorophenol에 의한 돌연변이 빈도의 비교(I))

  • Kim, In-Gyu;Park, Seon-Young;Yoon, Byung-Su;Cho, Myung-Haing;Lee, Yong-Soon
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.1
    • /
    • pp.15-21
    • /
    • 1997
  • In vitro somatic mutation induced by ${\gamma}$-radiation and pentachlorophenol(PCP) which is representative of chemical pollutant was measured at the hypoxanthine-guanine phosphoribosyl transferase(hprt) locus in human T- lymphocytes by a cell cloning assay. Mutant cells were selected by their ability to form a clone in the presence of purine analogue 6-thioguanine. The mutant frequencies by ${\gamma}$-irradiation to a dose of 1.0 Gy, 2.0 Gy and 3.0 Gy were 40%, 400% and 750% higher than those in controls. Significant changes were not observed in mutant frequencies in the 0.2 Gy and 0.5 Gy irradiated groups. When the doses of PCP were 15 ppm, 25 ppm and 50 ppm, the mutant frequencies increased by 30%, 90% and 520%, respectively. No changes were observed in the 10 ppm treated group. Similar types of dose-response relationship were shown in the two different mutagens. Reverse transcriptase/polymerase chain reaction technique(RT/PCR) was needed for the mutation spectrum to discriminate combined exposure to radiation and chemicals.

  • PDF

Radiological Consequence of LOCA for a 900MWe French PWR (프랑스형 900 MWe PWR 에서 냉각재상실사고의 방사선학적 영향)

  • Moon, Kwang-Nam;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.1
    • /
    • pp.40-47
    • /
    • 1987
  • The amount of the radionuclide release to the environment during a LOCA and its radiological consequence are assessed, for a 900MWe French PWR which is similar to the KNU 9/10, according to RFS V.1.a, in which the source term has been revised more conservatively after the TMI accident. The assessed result shows that the whole body and thyroid doses at the site boundary(500m) for 2 hours after the release are 66 mrem and 13.5 rem, respectively, and are within the corresponding limits. It is expected, however, that the thyroid dose would exceed the limit if the fraction of the organic iodine is over 10% of the iodine inventory.

  • PDF

A Study on Development of a PIN Semiconductor Detector for Measuring Individual Dose (개인 선량 측정용 PIN 반도체 검출기 개발에 관한 연구)

  • Lee, B.J.;Lee, W.N.;Khang, B.O.;Chang, S.Y.;Rho, S.R.;Chae, H.S.
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.2
    • /
    • pp.87-95
    • /
    • 2003
  • The fabrication process and the structure of PIN semiconductor detectors have been designed optimally by simulation for doping concentration and width of p+ layer, impurities re-contribution due to annealing and the current distribution due to guard ring at the sliced edges. The characteristics to radiation response has been also simulated in terms of Monte Carlo Method. The device has been fabricated on n type, $400\;{\Omega}cm$, orientation <100>, Floating-Zone silicon wafer using the simulation results. The leakage current density of $0.7nA/cm^2/100{\mu}m$ is achieved by this process. The good linearity of radiation response to Cs-137 was kept within the exposure ranges between 5 mR/h and 25 R/h. This proposed process could be applied for fabricating a PIN semiconductor detector for measuring individual dose.