• Title/Summary/Keyword: 방사선학적 평가

Search Result 772, Processing Time 0.025 seconds

Coracoclavicular Ligament Augmentation Using TightRope® for Acute Acromioclavicular Joint Dislocation : Surgical Technique and Preliminary Results (TightRope®를 이용한 급성 견봉 쇄골 관절 탈구의 치료 : 수술 술기 및 예비 보고)

  • Cho, Chul-Hyun;Sohn, Sung-Won;Kang, Chul-Hyung;Oh, Geon-Myeoung
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.165-171
    • /
    • 2008
  • Purpose: The purpose of this study was to introduce a new surgical technique and to evaluate the preliminary results after operative treatment with using TightRope$^{(R)}$ for treating acute acromioclavicular joint dislocation. Material and Methods: We studies 10 patients who were followed up for more than 6 months after operative treatment with using an TightRope$^{(R)}$. A longitudinal incision approximately 4cm in length was made from 1cm medial to the acromioclavicular joint to the coracoid process, and then coracocalvicular ligament augmentation using TightRope$^{(R)}$ was done after splitting the deltoid. For postoperative stability, two 1.6 mm Kirschner wires were inserted temporarily across the acromioclavicular joint in all cases. The radiologic results on the serial plain radiographs and the clinical results according to the UCLA score were analyzed. Results: Radiologically, 7 cases showed anatomical reduction, 2 cases showed a slightly loss of reduction and 1 case showed partial loss of reduction. Clinically, 6 cases were excellent, 3 cases were good and 1 case was fair. Conclusion: Coracoclavicular ligament augmentation using TightRope$^{(R)}$ for treating acute acromioclavicular joint dislocation is a minimally invasive, safe procedure that provides satisfactory radiologic and clinical preliminary results. Yet the long-term results have to be analyzed to determine the final results of this procedure.

Comparison of Anterior Cruciate Ligament Reconstructions Using Hamstring Tendon Autograft and Tibialis Tendon Allograft (자가 슬괵건 및 동종 경골건을 이용한 전방 십자 인대 재건술의 결과 비교)

  • Song, Eun-Kyoo;Seon, Jong-Keun;Bae, Bong-Hyun;Park, Sang-Jin;Kim, Jong-Seon;Lee, Dam-Seon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.141-147
    • /
    • 2006
  • Purpose: To compare the clinical and radiological results of anterior cruciate ligament(ACL) reconstruction using hamstring autograft and tibialis tendon allograft. Materials and Methods: Twenty four ACL reconstructions using hamstring autograft and 30 using tibialis anterior tendon altograft were followed up at least 1 year. We performed femoral tunnel fixation with Ligament Anchor(LA) screw and tibial tunnel fixation with biodegradable interference screw. Evaluations included Lysholm knee(LK) score, Tegner activity scale, Lachman test, Pivot-Shift test, Quardriceps atrophy, incision site numbness, anterior knee pain and instrumented anterior laxity with $Telos^{(R)}$ device. Results: Preoperativ mean LK score was $60.3(18{\sim}82)$ in autograft group and 61.2(25-80) in allograft group. Mean LK score improved to $91.6(68{\sim}100)\;and\;92.6(77{\sim}100)$ respectively. Activity level, using Tegner activity scale, slightly decreased compared with that of Preinjury state in both groups. Lachman test, pivot-shift test, Quadriceps atrophy, anterior knee pain, incision site numbness, and anterior drawer test using $Telos^{(R)}$ device showed no significant difference between two groups (p>0.05). Conclusion: In performing the ACL reconstruction, there was no statistically significant difference between hamstring autograft group and tibilis anterior allograft group in clinical or in radiological results.

  • PDF

Internal Fixation of Proximal Humerus Fracture with Locking Compression Plate (잠김 압박 금속판을 이용한 근위 상완골 골절의 내고정술)

  • Park, Chul-Hyun;Park, Sung-Hyuk;Seo, Jae-Sung
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.44-52
    • /
    • 2009
  • Purpose: We assessed the radiographic and clinical results of one surgeon's experience treating proximal humerus fractures with a locked proximal humeral plate. Materials and Methods: Twenty patients with unstable proximal humerus fractures were treated with a locking compression plate between February 2005 and September 2007. The average age of the patients was 60.6 years, and the average postoperative follow-up period was 22.3 months. The clinical results were evaluated using the Constant and DASH scores. The radiologic results were evaluated by the Paavolainen method, which measures the neck shaft angle and humeral head height. Results: At the last follow-up examination, the mean Constant score was 75.3 and 15 cases (75%) had excellent or good results; the mean DASH score was 16.4. The mean neck shaft angle was $137.1^{\circ}$, and 19 cases (95%) had good results by the Paavolainen method. There was one delayed union, malunion, and screw loosening. Conclusion: The patients treated with a locking compression plate had relatively good clinical and radiologic results, and a low complication rate. Moreover, the patients could exercise earlier due to good reduction and initial stability. Treatment of unstable proximal humerus fractures with a locking compression plate is a reliable method.

Evaluation of Effectiveness of Anatomical Rotation Change Image by Aid Tool in Shoulder MRArthrography (Shoulder MRArthography 검사 시 보조기구를 이용한 해부학적 회전 변화 영상에 대한 유용성 평가)

  • Kim, Hyeong-Gyun;Jung, Jae-Eun;Jung, Hong-Moon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.299-303
    • /
    • 2012
  • Shoulder MRArthrography was performed to get an accurate diagnosis about complex anatomical structure in shoulder joint. We carried out how the changes of anatomical rotations in shoulder joint could bring certain diagnosis effects on MRI images for various shoulder humerus positions; Neutral position, Internal rotation position and External rotation position. In addition, we prepared an aid tool in oder to maintain the right posture of a patient. This aid tool was made by adapting Modeling Design Program. By virtue of this aid, we obtained the following result. Shoulder MR Arthrography by the External rotation position for anatomical structure diagnosis was the most suitable in diagnostic evaluations of important anatomical structures in shoulder joint such as Biceps tendon, Supera-spiatus tendon, Sub-scapularis tendon, Labrum and Sub-acromial space.

Evaluation of VMAT Dose Accuracy According to Couch Rotation in Stereotactic Radiation Surgery of Metastatic Brain Cancer (전 이성 뇌 암의 정위 방사선수술에서 Couch 회전에 따른 VMAT의 선량 정확성 평가)

  • Na, Gwui Geum;Park, Byoung Suk;Cha, Woo Jung;Park, Yong Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.117-125
    • /
    • 2021
  • Purpose: To purpose of this study is to find the correlation of the Set-up error according to the couch rotation and suggest additional margin setting for the GTV. Target and Method: Each scenario treatment plan was created by making the frequency of non-coplanar beams different among all beams. The set-up error value was measured by using the Exact System and the dose accuracy was evaluated by creating a re-treatment plan. Results: When the couch was rotated by 30°, 45°, 60°, and 90°, the mean of the X-axis values was measured to be 0.29 mm, 0.26 mm, 0.51 mm, and 0.08 mm, respectively. The mean of the Y-axis values was measured to be 0.75 mm, 0.5mm, 0.35 mm, and 0.29 mm, respectively. The mean of the Z-axis values was measured to be 0.5 mm, 0.28 mm, 0.22 mm, and 0.1 mm, respectively. There were dose reductions of 0.1%, 3.1%, 1.9% in D99 for 1-NC VMAT, 2-NC VMAT, and 3-NC VMAT, respectively. Conclusion: When treating with 50% or more of non-coplanar beams among total beams, image verification is required. And it is considered to make the treatment plan by adding a 1.5 mm margin to the GTV.

An Experimental Study on the Effectiveness of Microwave Hyperthermia Combined with Radiation on the Small and Large Intestine in rats (흰쥐의 장조직에 X-선 조사와 마이크로파 온열요법의 효과에 관한 실험적 연구)

  • Ahn, Kyung-Sook;Lee, Kyung-Ja;Rhee, Chung-Sik
    • Radiation Oncology Journal
    • /
    • v.5 no.2
    • /
    • pp.83-95
    • /
    • 1987
  • The synergistic effect of combining radiation therapy and hyperthermia kills significantly more cells than using either modality alone. The reason for enhanced cell killing from the combined treatment is that the two modalities are complementary. For histopathological exmination, 102 rats were divided into 4 groups as hyperthermia, radiation, hyperthermia combined with radiation and normal control groups. The effect of prior irradiation (6-15 Gy of X-ray) on the response of small and large bowel of rats to $40^{\circ}C-44^{\circ}C$ (for 30 minutes) microwave (2450 MHz) hyperthermia was investigated. The musculature of the small and large intestine remained intact and the circumference of the histological sections were not significantly altered by the heated at $43^{\circ}C$ for 30 minutes. Thermal enhancement ratios of normal tissue is 1.0 Thermal enhancement ratio was not increased in combination therapy by evaluation of histopathologic changes in small and large intestine.

  • PDF

The Usefulness of Ultrasonography in the Evaluation of Clavicle Fracture Healing (쇄골 골절의 골유합 평가에 있어서 초음파의 유용성)

  • Moon, Dong Kyu;Park, Hyung Bin
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.2
    • /
    • pp.66-71
    • /
    • 2011
  • Purpose: This study was conducted to determine the usefulness of ultrasonography in evaluating callus formation in radiologically suspected nonunion or delayed union of clavicle fractures during conservative management. Materials and Methods: Six male patients and one female patient (average age: 38.3 years; range: 7 to 70 years), whose conservatively managed clavicle fractures were suspected of nonunion or delayed union, were examined with ultrasonography. If callus formation was detected, the patient continued to receive conservative management. If callus formation was not detected, the patient received operative management. Results: Six patients, in whom callus formation was observed ultrasonographically, continued to receive conservative management. The final simple radiographies of their fractures showed complete unions. One patient, in whom no callus formation was observed ultrasonographically, received operative management. In that patient, there was no operative finding of any fracture healing. Conclusion: Ultrasonography is a useful tool for evaluating callus formation in clavicle fractures suspected of nonunion or delayed union during conservative management. Ultrasonography can be used to avoid unnecessary surgery.

  • PDF

Manufacture and Image Characteristic Changes Observation by Temperature of Ultrasound Tissue Mimicking Phantom (초음파 Tissue Mimicking 팬텀의 제작과 온도 변화에 따른 영상 특성 변화 관찰)

  • Ma, Sang-Chull
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.157-161
    • /
    • 2016
  • The purpose of this study is that in measures the acoustic propagate characteristics and temperature sensitivity of ultrasound tissue mimicking phantom(TM phantom). TM phantom manufacture according to the International Electronical Committee(IEC) guidelines for acoustic propagate characteristics of soft tissue. TM phantom was observed to have the image brightness and the image depth penetration decreases changes convergence which was the subject of ultrasound image characteristics in accordance with an external temperature that the change is reduced in temperature below $22^{\circ}C$. This study provide a basis t o create another TM Phantom and TM Phantom has been determined that it is appropriate for use in more than $22^{\circ}C$.

고체 팬톰을 이용한 방사선치료계획시스템의 정도관리

  • 이상훈;조광환;조삼주;최진호;추성실;권수일;신동오
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.65-65
    • /
    • 2003
  • 목적 : 방사선치료기술이 날로 발전함에 따라 방사선치료계획시스템에 대한 주기적인 정도관리의 필요성은 증대하고 있으나, 국내 실정에 적합한 표준화된 정도관리절차서가 없는 실정이다. 따라서 본 연구에서는 방사선치료계획용 시스템에 대한 정도관리용 고체팬톰을 제작하여 주기적인 정도관리 활용 및 절차서를 제시하고자 한다. 대상 및 방법 : 체윤곽 보정을 위한 삼각기둥 모형 (30cm$\times$30cm$\times$5cm, 30cm$\times$15cm$\times$5$\times$) 및 정형ㆍ부정형, 불균질 측정이 가능한 물등가고체팬톰을 제작하였고, 컴퓨터단층촬영(AcQsim)을 통해 영상을 얻었으며, RTPS(AcQplan)에 입력하여 영상 내 기준점에서의 선량값을 계산하였다. RTPS를 통해 계산된 값의 평가를 위해 동일한 조건하에서 각 기준점에 대한 실제 측정을 이온함을 이용하여 측정하였다. 평가 항목으로는 정방형 조사면, 부정형 조사면, 쐐기 조사면, 불균질 물질 보정, 사방향 조사 등에 대해서 알고리즘별로 수행하였다. 결과 : RTPS를 이용하여 계산된 값과 실제 측정한 값을 비교하여 RTPS의 정확성을 평가한 결과로 합성의 불확도 허용 기준 (3%), 선속 중심축 상에서의 허용 기준 (2%) 등, 선진 각국 및 각 학회에서 권고하고 있는 허용 범위 내에서 잘 일치하였다. 결론 : RTPS는 측정된 심부선량과 선량분포 등 물리적인 인자에 의존하는 제한성이 있고, 실제로 선량계산 알고리즘과 기하학적 변화에 따라 계산값과 측정값 간에 차이가 발생할 수 있었다. 실제 인체의 체윤곽 불균일성과 불균질성을 모사한 팬톰을 제작하여 이용함으로써 다양한 RTPS간의 비교를 통한 치료 선량의 정확성을 평가하고, 방사선 치료의 원활하고 정확한 수행을 위해 실용적이고, 보편적인 치료계획 시스템의 정도관리 방법과 절차서를 수립하는데에 유용할 것으로 사료된다.

  • PDF

Evaluation of Dose Distribution of 6 MV X-ray using Optical Dosimetry (광 도시메트리시스템을 이용한 치료용 6 MV X선 선량분포 평가)

  • Kim, Sunghwan
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.925-932
    • /
    • 2019
  • In this paper, we developed optical dosimetry system with a plastic scintillator, a commercial 50 mm, f1.8 lens, and a commercial high-sensitivity CMOS (complementary metal-oxide semiconductor) camera. And, the correction processors of vignetting, geometrical distortion and scaling were established. Using the developed system, we can measured a percent depth dose, a beam profile and a dose linearity for 6 MV medical LINAC (Linear Accelerator). As results, the optically measured percent depth dose was well matched with the measured percent depth dose by ion-chamber within 2% tolerance. And the determined flatness was 2.8%. We concluded that the optical dosimetry system was sufficient for application of absorbed dose monitoring during radiation therapy.