• Title/Summary/Keyword: 방사선학적 평가

Search Result 772, Processing Time 0.024 seconds

Evaluation of Passive Joint Laxity of the Coxofemoral Joints from Distraction Radiography in the Korean Jindo (신연촬영법에 의한 진돗개 고관절 이완성의 방사선학적 평가)

  • Kim Sangki
    • Journal of Veterinary Clinics
    • /
    • v.21 no.4
    • /
    • pp.369-373
    • /
    • 2004
  • The pelvic distraction-stress radiographs of 50 clinically normal Korean Jindo which confirmed to have non-dysplastic hip joints on the ventrodorsal extension view, were investigated to evaluate the passive coxofemoral joint laxity as quantified by the distraction index. The synovial fluid cavitation of the unilateral coxofemoral joint was detected in 8 dogs, and distraction index was not measured in theses cavitated joints. The distraction index measured minimally 0.20, and maximally 0.74. The medial distraction index for the dog examined was 0.42, and 75th percentile distraction index was below 0.50.

Feasibility Study of Non Local Means Noise Reduction Algorithm with Improved Time Resolution in Light Microscopic Image (광학 현미경 영상 기반 시간 분해능이 향상된 비지역적 평균 노이즈 제거 알고리즘 가능성 연구)

  • Lee, Youngjin;Kim, Ji-Youn
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.623-628
    • /
    • 2019
  • The aim of this study was to design fast non local means (FNLM) noise reduction algorithm and to confirm its application feasibility in light microscopic image. For that aim, we acquired mouse first molar image and compared between previous widely used noise reduction algorithm and our proposed FNLM algorithm in acquired light microscopic image. Contrast to noise ratio, coefficient of variation, and no reference-based evaluation parameter such as natural image quality evaluator (NIQE) and blind/referenceless image spatial quality evaluator (BRISQUE) were used in this study. According to the result, our proposed FNLM noise reduction algorithm can achieve excellent result in all evaluation parameters. In particular, it was confirmed that the NIQE and BRISQUE evaluation parameters for analyzing the overall morphologcal image of the tooth were 1.14 and 1.12 times better than the original image, respectively. In conclusion, we demonstrated the usefulness and feasibility of FNLM noise reduction algorithm in light microscopic image of small animal tooth.

The Efficacy of Conjugated Linoleic Acid and Carprofen in Progression of Early Stage of Experimentally Induced Osteoarthritis in Dogs (개에서 Conjugated Linoleic Acid와 Carprofen이 실험적 골관절염 초기 진행에 미치는 효능)

  • Park, Se-il;Bae, Jae-sung;Kwon, Young-sam;Jang, Hwan-soo;Li, Wen-xue;Lim, Jae-hyun;Eom, Ki-dong;Kim, Jung-eun;Jang, Kwang-ho
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.278-285
    • /
    • 2003
  • This study was performed to compare early stage changes following the administrations of Conjugated Linoleic Acid (CLA), Carprofen and their combinations in the experimental canine cranial cruciate ligament rupture. Twenty five mongrel dogs were divided into five groups; Groups 1, 2, and 3 received a sectioning the cranial cruciate ligament (CCL) of the right stifle joint, and were administered CLA (250 mg/kg/day/orally), carprofen (4.4 mg/kg/day/orally), and their combinations for 4 weeks beginning 4 weeks postsurgery, respectively. Group 4 received sectioning CCL and no treatment. Group 5 was composed of unoperated normal dogs. The macroscopic observation of cartilage erosions on both the condyles and plateaus were evaluated, and the severity of the cartilage lesions and synovial inflammation was examined histologically at eight weeks after surgery. Histological examinations including hematoxylin and eosin stain, standard toluidine blue method, PAS technique and Masson trichrome technique, hematologic and radiographic evaluation were perfonned after experimental surgery. Slight yellowish discoloration of the surface was found in some of the experimental dogs. However macroscopic findings showed no significant differences among the groups. In radiographic findings, cranial displacement of the proximal tibia relative to the femoral condyles in all groups was observed but no significant differences among the groups was seen. This study showed that oral administration of CLA, carprofen and their combinations revealed no early stage change in the canine stifle joint following experimental rupture of the cranial cruciate ligament.

Comparative study on the apical sealing ability according to the obturation techniques (근관충전방법에 따른 치근단부 폐쇄능에 대한 비교연구)

  • Hwang, Ho-Keel;Park, Sun-Hee;Lee, Yeon-Jae
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.3
    • /
    • pp.290-298
    • /
    • 2002
  • 3차원적으로 잘 충전된 근관은 치근단 누출과 재감염을 방지하며, 조직이 잘 치유될 수 있는 생물학적 환경을 제공해준다. 이 때문에 근관계의 완전한 충전은 근관치료의 중요한 목표 중의 하나이다. 본 연구의 목적은 4가지 방법으로 근관충전 후 디지털 방사선 사진을 촬영하여 근관충전의 질을 평가하고 투명표본을 제작하여 색소침투범위를 측정함으로써, 근관충전방법에 따른 치근단부 폐쇄능을 비교 평가하고자 하는 것이다. 직선형의 단근관을 갖는 80개의 전치를 선택하여 ProFile$^{\circledR}$ 니켈-티타늄 회전식 기구를 사용하여 근관을 성형한 후 무작위로 20개씩 4군으로 나누었다. 사용된 근관충전법은 다음과 같다:MicroSeal$^{\circledR}$(Group A), Thermafil$^{\circledR}$(Group B), Continuous wave 충전법(Group C), 측방가압충전법(Group D), 각 군에서 10개 치아는 Sealapex를, 나머지 10개 치아는 AH26$^{\circledR}$을 충전용 시멘트로 사용하였다. 근관충전이 끝난 치아는 충전의 질과 길이를 평가하기 위해, 근원심과 협설방향으로 디지털 방사선 사진을 이용하여 촬영하였다. 각 치아의 치근단부 2mm를 제외한 나머지 부위는 두겹의 nail varnish를 바르고, 2% methlylene blue용액에 48시간동안 침잠시켰다. 흐르는 물에 깨끗이 세척한 후, 투명치아를 만들었다. 선상의 색소침투를 관찰하고 치관측 최대깊이를 입체현미경하에서 40배율로 평가하여 다음과 같은 결과를 얻었다. 1. 충전방법에 따른 근단부 폐쇄효과를 비교시, 실험군 모두 비교적 양호한 근단부 폐쇄효과를 보였고 통계학적으로 유의성이 없었다. 2. 충전용 시멘트에 따른 근단부 폐쇄효과를 비교시, AH26$^{\circledR}$을 사용한 군에서 Sealapex를 사용한 군보다 더 적은 색소침 투를 나타냈다(p<0.05). MicroSeal$^{\circledR}$을 이용한 실험 1군내에서 AH26$^{\circledR}$을 사용하였을 때 미세누출이 더 적었고(p<0.05), 다른 군내에서는 통계학적으로 유의성이 없었다. 3. 근단부 충전상태에 따른 미세누출 비교시, 저충전, 과충전과 색소침투간에는 상관관계가 없었다. 4.충전방법에 따른 근단부 충전상태 평가시, Thermafil$^{\circledR}$을 이용한 실험 2군에서 과충전이 많이 나타났다(p<0.05). 이상의 결과로, 기존의 측방가압법 및 여러 열가소성 충전법이 유사한 근단부 폐쇄효과를 나타낸 바, 방법에 따른 술자의 숙련도, 충전시간, 재근관치료의 편이성 등을 고려하여 근관충전방법을 선택하는 것이 합리적일 것이라고 사료된다.

Study of Radiological Approach to Treat a Chronic Constipation (만성변비환자의 방사선학적 접근방법에 관한 고찰)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.3
    • /
    • pp.5-12
    • /
    • 2004
  • I. Introduction : The constipation is one of the common gastrointestinal symptoms seen in the clinical practice. When people come to the clinic complaining of the constipation, it is generally one of the cases of infrequent, painful or difficult evacuation as well as the hardened feces and unsatisfactory evacuation sense. Since the constipation is heavily influenced by dietary habit as well as the social and medical environment, the diagnostic radiology is useful to establish the objective and standardized definition in consideration of those various factors before diagnosis and treatment of the constipation patient. This paper describes the study of such diagnosis. II. Main Subject : Testing of CTT (colon transit time) is key study of the colon performance. CTT is very helpful in classifying the pathologic physiological types and defining the treatment plan for the chronic constipation. The study methods include using the radipaque marker, multiple marker technique and scintigraphic measurement. The defecography is the functional radiologic examination a that provides not only the anatomical information of anorectal but also performance of the pelvic floor and rectal change during evacuation. Study of dynamic movement of the anorectal during evacuation is helpful for diagnosis and treatment planning as well as follow-up testing for the constipation patient. One of the issues essential for the case history is the thorough observation of whether the patient shows the psychic psychological symptoms such as the behavior disorder or emotional disturbance. In that case, the decision must be made whether or which type of medication is needed for such psychiatric problem. III. Conclusion : The main causes of the constipation are insufficient intake of fiber or liquid. The key objective of such tests is to check etiology of the constipation. In general, the radiological examination does not provde the colon or anorectal performance information. It is envisaged that this study will provide the information to decide the testing and treatment plans and predict the prognosis of the patient by classifying the pathologic physiological types.

  • PDF

Thermographic Evaluation of Beating Process of Experimentally Induced Infectious Arthritis in Horses (실험적으로 유발한 말 감염성 관절염의 치유경과에 대한 체열학적 평가)

  • Yang Young-Jin;Nam Tchi-Chou
    • Journal of Veterinary Clinics
    • /
    • v.23 no.1
    • /
    • pp.22-30
    • /
    • 2006
  • This study was carried out to assess the usefulness of thermography for diagnosis and healing process of musculoskeletal disorder in horses. Horses with experimentally induced infectious arthritis were treated with bee venom or antibiotics for 5 weeks from 24 hours after inoculation of Staphylococcus aureus, the effectiveness of the 2 therapeutic drugs treatment was similar to each other. Thermographic evaluation was similar to any other tests, because the thermal pattern tend to return to normal with declining similar to those of clinical signs, laboratory experiments and healing of the lesion. This ability to assess inflammatory change noninvasively make thermography an ideal imaging tool to aid in the diagnosis of certain lameness condition or musculoskeletal disease in horses. These results suggested that thermographic evaluation in horses with musculoskeletal disorders were useful for diagnosis and helpful for monitoring of healing process.

Evaluation of Magnetic Resonance Imaging using Image Co-registration in Stereotactic Radiosurgery (정위방사선수술시 영상공동등록을 이용한 자기공명영상 유용성 평가)

  • Jin, Seongjin;Cho, Jihwan;Park, Cheolwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.235-240
    • /
    • 2017
  • The purpose of this study is to confirm the safety of the clinical application of image co - registration in steteotactic radiosurgery by evaluating the 3D positioning of magnetic resonance imaging using image co-registration. We performed a retrospective study using three-dimensional coordinate measurement of 32 patients who underwent stereotactic radiosurgery and performed magnetic resonance imaging follow-up using image co-registration. The 3 dimensional coordinate errors were $1.0443{\pm}0.5724mm$ (0.10 ~ 1.89) in anterior commissure and $1.0348{\pm}0.5473mm$ (0.36 ~ 2.24) in posterior commissure. The mean error of MR1 (3.0 T) was lower than that of MR2 (1.5 T). It is necessary to minimize the error of magnetic resonance imaging in the treatment planning using the image co - registration technique and to confirm it.

Dose Assessment of the Eye of the Operator in the Field of Angiography and Interventional Radiography (혈관조영 및 중재적 시술 분야 내 종사자의 눈에 대한 선량평가)

  • Kim, Jung-hoon;Cho, Yong-In
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.209-216
    • /
    • 2018
  • In the field of angiography and interventional radiology, it is said that the risk of radiation exposure to the eyes is high due to the characteristics of work, but currently divided dose assessment and management are not carried out in reality. Therefore, in this study, in order to evaluate the dose of the operator in the surgical environment and to analyze the shields, firstly, we selected the point where the operator is mainly located, evaluated the exposure dose of the eye after attaching the pocket dosimeter to the lateral angle point of the head and neck phantom, and evaluate shielding effect when wearing lead glasses that is currently commercialized. Secondly, we evaluated the tendency of the exposure dose of the eye and the shielding effect through simulation in the same geometric structure as the actual measurement. As a result, in the case of measurement using a dosimeter, the cumulative dose increased with the increase of the fluoroscopic time, and the tendency was different according to the position of the operator. Simulation results show that the dose distribution of the eye lens in the mathematical phantom is about 1.1 ~ 1.3 times higher than that of the cornea. Also, The protective effect of the lead glasses showed a shielding effect of at least 3.7 ~ 21.4% in each eye.

Postoperative Radiotherapy for Intracranial Meningioma (뇌수막종 환자의 수술 후 방사선치료)

  • Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.95-99
    • /
    • 2001
  • Purpose : To evaluate the effectiveness and tolerance of postoperative external radiotherapy for patients with intracranial meningiomas. Materials and Methods : The records of thirty three patients with intracranial meningiomas who were treated with postoperative external irradiation at our institution between Feb, 1988 and Nov, 1999 were retrospectively analyzed. Median age of patients at diagnosis was 53 years with range of 17 to 68 years. Sites of involvement were parasagital, cerebral convexity, sphenoid ridge, parasellar and tentorium cerebelli. Of 33 evaluated patients, 15 transitional, 10 meningotheliomatous, 4 hemangiopericytic, 3 atypical and 1 malignant meningioma were identified. Four patients underwent biopsy alone and remaining 29 patients underwent total tumor resection. A dose of 50 to 60 Gy was delivered in 28-35 daily fractions over a period of 5 to 7 weeks. Follow-up period ranged from 12 months to 8 years. Results : The actuarial survival rates at 5 and 7 years for entire group of patients were 78% and 67%, respectively. The corresponding disease free survival rates were 73% and 61%, respectively. The overall local control rate at 5 years was 83%. One out of 25 patients in benign group developed local failure, while 4 out of 8 patients in malignant group did local failure (p<0.05). Of 4 patients who underwent biopsy alone, 2 developed local failure. There was no significant difference in 5 year actuarial survival between patients who underwent total tumor resection and those who did biopsy alone. Patients whose age is under 60 showed slightly better survival than those whose age is 60 or older, although this was not statistically significant. There was no documented late complications in any patients. Conclusion : Based on our study, we might conclude that postoperative external beam radiotherapy tends to improve survival of patients with intracranial meningiomas comparing with surgery alone.

  • PDF

STUDY OF INVERTLY IMPACTED SUPERNUMERARY TEETH IN THE MIDPALATAL REGION USING COMPUTERIZED TOMOGRAPHY (전산화 단층 방사선사진을 이용한 상악 정중부 역위 매복 과잉치에 관한 연구)

  • Choi, Byung-Jai;Lee, Yong-Seok;Kim, Seong-Oh;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.363-372
    • /
    • 2003
  • Supernumerary teeth are found frequently in the dental office causing many dental complications. They are one of the many dental abnormalities that may occur during tooth development. Inversely impacted supernumerary teeth in the midpalatal area are especially important clinically because they occur with high frequency and many complications. Though many previous clinical and radiographical studies exist, the sample numbers were small and the evaluation of shape, location, and effects to its surrounding tissue may not be accurate due to the solitary use of intraoral radiographs or panoramic radiographs. Among the patients who visited department of pediatric dentistry, yonsei dental hospital, from July, 1998 to June, 2002, those with inversely impacted supernumerary teeth took computerized tomography for a more accurate diagnosis. Their dental chart, panoramic radiograph and computerized tomography were evaluated for this study. The number, form, convexity, location, distance, and complications of inversely impacted supernumerary teeth in the midpalatal area were recorded. This study show that when the supernumerary teeth is tuberculated with a curved root and is in close proximity to the adjacent teeth, it causes complications such as eruption disturbance, rotation, displacement of adjacent teeth, and diastema. Such factors must be considered in making decisions for diagnosis and treatment.

  • PDF