• Title/Summary/Keyword: 방사선학과

Search Result 1,057, Processing Time 0.032 seconds

Effect of Major Satisfaction on Career Commitment for Students in Department of Radiological Science (방사선학과 학생들의 전공만족도가 진로결정몰입도에 미치는 영향)

  • So, Woonyoung;Kim, So Yeon;Park, Chae Yeon;Kim, Yeon Jun;Roh, Hyo Lyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.415-424
    • /
    • 2019
  • The purpose of this study would like to investigate the effect of major satisfaction on the career decision commitment for students in department of radiological science. Using the structured questionnaire we perform the self-report survey for 218 students. As a result, the degree of major satisfaction for students is found to be mid-range, and the degree of career decision commitment for ones is lowest in the first graders and the highest in the fourth graders. A notable point is that the degree of major satisfaction seems to have a significant influence on career decision commitment. Especially, it was found that major of pride is the most influential factor in career decision commitment. From this study, finally, it seems that a method to improve the career decision commitment is needed because the degree of career decision commitment of students is assessed to be fairly lowered at a level of non-commitment.

Evaluation of Radioactive Substance and Measurement of Harmfulness in Drinking Water (먹는 샘물의 방사성물질 측정 및 유해성 평가)

  • Jo, Jungwon;Lee, Sangbok;Nam, Johyeon;Noh, Eunjeong;Beak, Hyunwoo;Lee, Yejin;Lee, Joonse;Choi, Jiwon;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.247-252
    • /
    • 2021
  • As the number of single-person households increases, the consumption of bottled water is increasing. In addition, as the public's interest in radioactivity increases, interest in the field of living radioactivity is also increasing. Since drinking water is an essential element in our daily life, it must be safe from radioactivity. In this study, gamma radiation of drinking spring water was measured and internal exposure dose evaluation was performed to determine its harmfulness. K-40 and uranium-based radioactivity analysis was performed through a high-purity germanium detector, and as a result, drinking water was detected somewhat higher than that of mixing water. Since there is no regulation on the natural radioactivity concentration in Korea, it was compared with the U.S. Environmental Protection Agency Drinking Water Regulations and World Health Organization standard. As a result, there were some items that exceeded standards. Internal exposure was evaluated according to the effective dose formula of ICRP 119. As the result was derived that a maximum of 1.17 mSv per year could be received. This result means that the dose limit for the general public may be exceeded, and it was judged that it is necessary to set an appropriate standard value and present a recommendation value through continuous monitoring in the future.

Analysis of Radioactivity Concentration at Beaches in the Yeongnam Region, Republic of Korea (대한민국 영남지역 해수욕장의 방사능 농도 분석)

  • Jeong-Ho An;Jin-Gu Kang;Jun-Su Kim;Bo-Yeon Kim;Ja-Young Baek;Min-Su Seol;Seul-Ki Cho;Ye-Eun Kim;Yu-Min Lee;Jong-Soo Choi;Jae-Hwan Cho
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1197-1205
    • /
    • 2023
  • In this study, the spectrum due to radioactivity contained sand samples from famous beaches in the Yeongnam region was measured. The sand samples were from eight famous beaches in Yeongnam region and were placed into a high-purity germanium detector (HPGe) using with an electric field, which is a semiconductor detector and subjected to a precision analysis of the gamma-rays emitted from the radionuclides in the sand by using a multichannel analyzer (MCA). To measure the concentration of the radionuclides, we obtained a spectrum by analyzing the gamma-rays emitted from the radionuclides for a measurement time of 8,000 seconds. As a result of analyzing the spectrum table, Tl-208 had the highest radioactivity at all eight beaches: A, B, C, D, E, F, G, and H. In conclusion, radionuclides detected in sand samples from beaches in the Yeongnam region are natural radionuclides, but they can affect the inside of the human body. Therefore, there is a need for continuous investigation.

Soil Radioactivity in Urban Parks of Incheon (인천지역 근린공원의 토양 방사능 농도)

  • Jun-Su, Jang;Sang-Bok, Lee;Ga-Eun, Baek;Hee-Cheol, Shin;Gyeong-Jae, Lee;Do-Hwa, Lee;Sungchul, Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.37-42
    • /
    • 2023
  • Most of research on environmental radioactivity is conducted in areas near nuclear power plants, so basic data about the distribution of environmental radioactivity in soil in other areas are insufficient. Therefore, in this study, divide into four categories by the land development characteristics of Incheon and the purpose of development, and confirm the stability of the Incheon through soil sample collection and gamma-ray analysis based on 40K, 137Cs and 226Ra (214Pb, 214Bi). The spectrum obtained by measuring for 80,000 seconds by using the HPGe detector was analyzed by Genie 2000 program. Soil radioactivity concentrations in urban parks of Incheon area are generally within a safe range compared to the results of the Nuclear safety and security commission. However, as 137Cs was detected in one park, which will require continuous monitoring.

Comparison of Satisfaction on Each Major Dept. of Health-Related Universities Located in Busan and Gyeongnam (부산, 경남 지역 보건계열 대학(교)의 전공학과별 전공만족도 비교)

  • Shin, Sung-Gyu
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.131-140
    • /
    • 2011
  • This study is to investigate the satisfaction rate and relative factors from the students majored in Radiology, Clinical Pathology and Physical Therapy, which can provide basic knowledge of satisfaction and guide the university life and further careers. The survey was performed with respect to 107 students of Radiology, 97 of Clinical Pathology and 89 of Physical Therapy at three-year or four-year colleges(universities) located in Busan and Gyeongsangnam-do. The results show that the satisfaction rate through whole majors was $3.40{\pm}0.57$ point. The scores of each major are: $3.38{\pm}0.62$ for Radiology, $3.37{\pm}0.56$ for Clinical Pathology, and $3.45{\pm}0.50$ for Physical Therapy. The score of social status was highest and the environment of major was the lowest. The satisfaction of three-year colleges was higher than that of four-year universities. Academic system, social status and adaptation to major affected satisfaction on major. In addition job outlook affected on all majors. Thus, we propose that every major must be equipped with specialized environment different from general colleges (universities), and provide environment where students can cause self-motivation. In addition, we found the special way to improve social status and satisfaction by using career guidance, offering career information and performing university-industry collaborations. Especially, it is important to improve the satisfaction on major of students at four-year universities.

Sound Recognition Devices for audibly impaired Individuals (Hearing impaired accident prevention application using artificial intelligence) (청각 장애인의 소리 인식 보조기기 (인공지능을 이용한 청각 장애인 사고 예방 어플리케이션) )

  • Jung-Ho Ko;Wan-Ho Lee;Hee-Seung Shin;Sung-Hwan KIm;Youl-hun Seoung;Ho-Sup Lee
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.11a
    • /
    • pp.1010-1011
    • /
    • 2023
  • 코로나19 팬데믹 이후 배달 앱 사용량이 증가에 따라 배달 오토바이 수가 급증하면서 이와 관련 사고 또한 급격히 증가하는 추세를 보이고 있다. 특히 청각 장애인들은 도로에서 이러한 종류의 사고 위험에 더욱 노출되어 있으며, 이 문제를 해결하기 위해 구글 앱 인벤터를 사용하여 도로에서 오토바이 소리를 인식하는 인공지능 학습 모델을 개발하였다. 개발된 어플리케이션은 도로에서 오토바이 소리를 감지하고 사용자에게 진동과 사진으로 알림을 보냄으로써 사고를 예방에 기여할 수 있다.

Optimization of Non-Local Means Algorithm in Low-Dose Computed Tomographic Image Based on Noise Level and Similarity Evaluations (노이즈 레벨 및 유사도 평가 기반 저선량 조건의 전산화 단층 검사 영상에서의 비지역적 평균 알고리즘의 최적화)

  • Ha-Seon Jeong;Ie-Jun Kim;Su-Bin Park;Suyeon Park;Yunji Oh;Woo-Seok Lee;Kang-Hyeon Seo;Youngjin Lee
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.39-48
    • /
    • 2024
  • In this study, we optimized the FNLM algorithm through a simulation study and applied it to a phantom scanned by low-dose CT to evaluate whether the FNLM algorithm can be used to obtain improved image quality images. We optimized the FNLM algorithm with MASH phantom and FASH phantom, which the algorithm was applied with MATLAB, increasing the smoothing factor from 0.01 to 0.05 with increments of 0.001 and measuring COV, RMSE, and PSNR values of the phantoms. For both phantom, COV and RMSE decreased, and PSNR increased as the smoothing factor increased. Based on the above results, we optimized a smoothing factor value of 0.043 for the FNLM algorithm. Then we applied the optimized FNLM algorithm to low dose lung CT and lung CT under normal conditions. In both images, the COV decreased by 55.33 times and 5.08 times respectively, and we confirmed that the quality of the image of low dose CT applying the optimized FNLM algorithm was 5.08 times better than the image of lung CT under normal conditions. In conclusion, we found that the smoothing factor of 0.043 among the factors of the FNLM algorithm showed the best results and validated the performance by reducing the noise in the low-quality CT images due to low dose with the optimized FNLM algorithm.

Development of Touch-Conversion Device of Heartbeat for Deaf Parents in Fetal Ultrasonography (청각장애 산모의 태아 초음파 심장박동 촉각 변환 시스템 개발)

  • Chu, Jihye;Choi, Daso;Choi, Yujin;Heo, Dahyeong;Lee, Ho-Seop;Seoung, Youlhun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.997-999
    • /
    • 2022
  • 아기의 심장 박동 소리를 듣지 못하는 청각 장애 부모를 위한 태아 초음파 심장박동 촉각 변환 시스템을 개발하고자 하였다. 본 시스템은 아기의 심장박동 소리를 USB 마이크를 이용하여 소릿값을 입력받아 이에 대응하는 값을 진동 모터의 진동 출력 세기와 LED 밝기의 세기로 출력시키도록 하였다. 아기의 심장박동 느낌을 진동으로 표현해 내기 위해 진동의 샘플링 주기를 구체적인 수치로 조절하였고 산모에 따라 진동의 세기와 주변 잡음 제거를 할 수 있도록 조절하는 가변저항 2개를 연결하였다. 그 결과 태아 초음파 심장박동 촉각 변환 시스템을 성공적으로 개발하였으며 장치 체험자들로부터 총 평균 4.63점으로 높은 만족도를 얻었다. 개발 제품은 청각장애 산모들의 모성애를 충족시키고 아기의 심장박동을 느낌으로써 아기의 존재를 느낄 수 있을 것이며, 산부인과의 초음파 영상진단의 확장 신기술로 활용할 수 있을 것으로 기대된다.

Analysis of Radioactivity Concentrations in Cigarette Smoke and Tobacco Risk Assessment (담배연기와 담뱃잎 내 함유된 방사능 농도분석 및 위해도 평가)

  • Lee, Se-Ryeong;Lee, Sang-Bok;Kim, Jeong-Yoon;Kim, Ji-Min;Bang, Yei-jin;Lee, Doo-Seok;Jo, Hyung-Joon;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.489-494
    • /
    • 2021
  • In this study, radioactivity quantitative analysis was performed on radon contained in cigarette, and the effective dose was calculated using the result value to determine the amount of exposure caused by smoking. A total of 5 types of cigarettes were sampled. Cigarette smoke was collected by using activated carbon, and tobacco were measured by homogenizing for quantitative analysis. For each sample, Bi-214 and Pb-214 were subjected to gamma nuclide analysis to observe the uranium-based radioactive material contained in cigarette, and a measurement time of 30,000 seconds was set for the sample based on the results of previous studies. As a result of measuring the radioactivity of tobacco, a maximum of 0.715 Bq/kg was derived, and in the case of cigarette smoke measured using activated carbon, a maximum of 3.652 Bq/kg was derived. Using this measurement, the average effective dose to the lungs is 0.938 mSv/y, and it was found that there is a possibility of receiving exposure up to 1.099 mSv/y depending on the type of tobacco. It was found that the exposure dose due to cigarette occupies a large proportion of the annual effective dose limit for the general public. Therefore, more diverse studies on radioactive substances in cigarette are needed, and measures to monitor and reduce the incidental exposure to radon should be established.

Doses of Pediatric and X-ray Examination Assistants according to Changes in Pediatric X-ray Exposure Conditions (소아 X선 촬영조건 변화에 따른 소아 및 촬영보조자 선량)

  • Beom-Jin Jang;Ha-Yun Nam;Hye-Min Shin;Dong-Min Yun;Seung-Kook Lee;In-Hwa Jang;Sungchul Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.409-415
    • /
    • 2023
  • Although pediatric X-ray examinations are continuously increasing, there are not many studies on the radiation exposure to children and X-ray examination assistants according to X-ray Exposure conditions. Accordingly, we measured the radiation exposure dose of pediatric and X-ray examination assistants according to the standard guidelines and clinical average X-ray Exposure conditions when X-ray examination 10-year-old children. The effective dose and organ dose to pediatric were measured using an Dose area production meter and Monte Carlo-based PCXMC program, and the exposure dose of X-ray examination assistants was measured using an ion-chamber. When performing abdominal supine AP projection, the effective dose to children was up to 2.38 times higher under clinical average X-ray Exposure conditions than the standard guidelines. In addition, during abdominal supine AP projection, the radiation exposure dose to the X-ray examination assistants was highest on the hands at 0.0148 ~ 0.0709 mSv, and exposure dose could be reduced by up to 35% when wearing protective gloves. In conclusion, because the X-ray Exposure conditions used in clinical are unnecessarily high, unnecessary medical radiation exposure could be reduced if appropriate X-ray Exposure conditions and the radiation field area were minimized and the assistant wore shielding gloves.