• Title/Summary/Keyword: 방사선피폭선량

Search Result 960, Processing Time 0.022 seconds

A Study on the Additional Absorbed Dose of Normal Tissues by Image Guided Radiation Therapy(IGRT) (영상유도 방사선 치료(IGRT)에 따른 정상 조직의 추가 피폭에 대한 연구)

  • Kim, Gha-Jung;Ryu, Jun-Min;Choi, Jun-Gu;Hong, Dong-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.75-81
    • /
    • 2016
  • The recent radiation therapy field can provide treatment which guarantees a high degree of accuracy, due to patient set-up using various image guided radiation therapy(IGRT) instruments. But the additional absorbed dose to patient's normal tissues is increasing. Therefore, this study measured the absorbed dose to surrounding normal tissues which is caused by patient set-up using OBI, CBCT, ExacTrac, among various IGRT instruments. The absorbed dose to the head, the chest, the abdomen, and the pelvis from CBCT was 12.57 mGy, 20.82 mGy, 82.93 mGy, and 52.70 mGy, respectively. Also, the absorbed dose from OBI and ExacTrac ranged from 0.76 to 8.58 mGy and from 0.14 to 0.63 mGy, respectively. As a result, CBCT's absorbed dose was far higher than other instruments. CBCT's surface dose was far higher than others, too, but OBI's entrance skin dose was almost the same as CBCT's.

Research on the Hematological Changes in Accordance with Radiation Dose and Radiation Exposure period of the Medical Radiation Workers (의료 방사선 종사자의 피폭기간 및 피폭선량과 혈액성분 변화에 대한 조사)

  • Cho, Jihwan;Jin, Seongjin;Park, Cheolwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.495-502
    • /
    • 2016
  • In this study, we analyzed the effects of radiation exposure, as compared to the hematological parameters change of medical radiation workers and the public. The mean value of all hematological parameters were in the normal range. Eosin mean value of the radiation workers($2.52{\pm}1.79%$) showed that a significantly lower than the control group($2.92{\pm}1.39%$). In the comparison of the results depending on the occupation period, it showed high value that the mean of the radiation workers group WBC, platelet, Lymph, Mono, Baso. Over 20 years of radiation workers WBC, Mono showed low values and less than 10 years of radiation workers mean value of Baso showed low values, there was no statistical significance. In the comparison of the results depending on the 4 years cumulative radiation dose, Over 5.0 mSv of Radiation works RBC($4.61{\pm}0.53$ vs $4.91{\pm}0.38$), Hct($41.51{\pm}4.07$ vs $43.97{\pm}3.40$), Eosin($1.74{\pm}1.14$ vs $2.92{\pm}1.39$) showed low value, it was statistical significance. 0.5~1.0 mSv radiation exposure workers Hb ($13.93{\pm}1.75$) showed a significantly lower value than that of the control group ($14.90{\pm}1.29$).

The Study of Energy Compensation Filter Thickness for Each Energy Area of Low Energy X-ray Beam Optimization on Active Electronic Personal Dosimeter (능동형 전자식 개인피폭선량계의 저에너지 X선 영역별 최적화를 위한 에너지보상 필터 두께에 대한 연구)

  • Kim, Jung-Su;Park, Youn-Hyun;Chae, Hyun-Sic
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.519-526
    • /
    • 2022
  • Electronic personal dosimeter (EPD) provide real time monitoring and a direct indication of the accumulated dose or dose rate in terms of personal dose. Most EPD do not perform well in low energy photon radiation fields present in medical radiation environments. It has poor responsibility and large error rate for low energy photon radiation of medical radiation environments. This study evaluated to optimal additional filtration for EPD using silicon PIN photodiode detector form 40 to 120 kVp range in medical radiation environments. From 40 to 80 kVp energy range, Al 0.2 mm and Sn 1.0 mm overlapped filtration showed good responsibility to dose rate and from 80 kVp to 120 kVp energy range, Al 0.2 mm and Sn 1.6 mm overlapped filtration showed good responsibility to dose rate.

Evaluation of Cancer Incidence Rate using Exposure Dose to Surrounding Normal Organs during Radiation Therapy for Prostate Cancer (전립선암의 방사선 치료 시 주변 정상장기 피폭선량을 이용한 암발생확률 평가)

  • Lee, Joo-Ah
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.351-356
    • /
    • 2022
  • The purpose of this study was to evaluate the cancer incidence rate and provide basic data by measuring the photoneutron dose generated during intensity-modulated radiation therapy and volumetric modulated arc therapy used in radiation therapy for prostate cancer. The optically stimulated luminescence albedo neutron dosimeter for neutron measurement was placed on the Rando phantom in the abdomen and thyroid and photoneutron dose generated was measured. As a result of the study, intensity-modulated radiation therapy (7 portal) was measured to be higher than volumetric rotational radiation therapy in both abdominal and thyroid locations. When the cancer incidence rate was evaluated using the nominal risk coefficient of ICRP 103, the cancer incidence rate due to exposure to the colon and thyroid during intensity-modulated radiation therapy was 9.9 per 1,000 people, and volumetric rotational radiation therapy for 1,000 people. It was 3.5 per person. Based on the principle of ALARA (As low as reasonably archievable), it is considered to be a guideline for minimizing the exposure dose to normal organs in the establishment of a radiation treatment plan.

An Estimate of Image Quality and Radiation Doses of Coronary Artery in MDCT Using Prospective and Retrospective ECG Gating Scan Mode (MDCT 관상동맥 조영 검사에서 전향적 동조화 및 후향적 동조화 기법의 화질과 선량 관계)

  • Oh, Jong-Kap
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.315-321
    • /
    • 2011
  • The goal of this study is to reduce patient exposure dose by providing image quality and radiation dose according to inspection methods. Volume Computed Tomography Dose Index(CTDIvol) and Dose Length Product(DLP) of prospective and retrospective ECG gating snapshot segment of Coronary CT angiography(CTA) were measured each snapshot segment methods. CT number, noise, uniformity, and resolution were also measured using phantom under the same condition of coronary CTA. The results showed that CT number, noise, uniformity and resolution are similar to each other. In terms of CTDIvol and DLP, however, measurement dose of prospective ECG gating snapshot segment was lower than the retrospective case by 37.5% and 40.3%. Therefore, it is highly recommended that in the coronary CTA, prospective ECG gating scan mode should be chosen to reduce patient dose.

Occupational Radiation Exposure in Korea: 2002 (2002년 국내 방사선 작업종사자의 직업군별 피폭선량)

  • Jeong, Je-Ho;Kwon, Jeong-Wan;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.4
    • /
    • pp.175-183
    • /
    • 2005
  • Dose distribution of Korean radiation workers classified by occupational categories was analyzed. Statistics of the occupational radiation exposure(ORE) in 2002 of the radiation workers in diagnostic and dental radiology were obtained from the Korea Food and Drug Agency(KFDA) who maintains the database for individual radiation dose records. Corresponding statistics for the rest of radiation workers were obtained by processing the individual annual doses provided by the Korea Radioisotope Association(KRIA) after deletion of individual information. The ORE distribution was classified in term of 28 occupational categories, annual individual dose levels, age groups and gender of 52733 radiation workers as of the year of 2002. The total collective dose was 66.4 man-Sv and resulting average individual ORE was 1.26 mSv. Around 80% of the workers were exposed to minimal doses less than 1.2 mSv. However, it appeared that the recorded doses exceeded 20 mSv for 43 workers in the industrial radiography and for 147 workers in the field of radiology. Particularly, recorded doses of 23 workers in radiology exceeded the annual dose limits of 50 mSv, which is extraordinary when the working environment is considered. It is uncertain whether those doses are real or caused by careless placing of dosimeters in the imaging rooms while the X-ray units are in operation. No one in the workforce of 16 operating nuclear power plant units was exposed over 20 mSv in 2002. Number of workers was the largest in their 30's of age and the mean individual dose was the highest in their 20's. Women were around 20% of the radiation workers and their average dose was around one half of that of man workers.

TLD dose variation of Magnetic Resonance Imaging Equipment (자기공명영상장비에서 열형광선량계의 선량 변화)

  • Je, Jaeyong;Kang, Eunbo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.473-476
    • /
    • 2012
  • The PET-MRI which has been installed and being managed recently uses both magnetic field and radiation. Most radiation workers wear a thermoluminescenct dosimeter (TLD) as a personal radiation dosimeter, and the TLD is affected both by a magnetic field and radiation. In this research, the same amount of X-ray was applied to 36 TLDs, and the changes in the dose of the 32 TLDs exposed to magnetic field at the location where its intensity of the magnetic resonance imaging (MRI) was about 5000 Gauss for eight hours with one-hour unit and that of the four TLDs not exposed to magnetic field were compared and checked. The measurement result showed that exposure dose of the TLD attached to the MRI changed irregularly depending on the amount of exposure time. Therefore, the TLD whose amount of changes little in the environment of a MRI is demanded to be developed.

Radiation Exposure According to Radiation Technologist' Working Departments (방사선 종사자 근무 분야별 피폭에 관한 검토)

  • Yoon, Chul-Ho;Yoon, Seok-Hwan;Choi, Jun-Gu
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.217-222
    • /
    • 2008
  • Radiation dose to radiologists working at three hospitals in Seoul was investigated from Jan 1, 2006 to Dec. 31, 2006. The results are as follows. First, radiation dose to radiologists at a cardiac angiography room was measured as 1.41mSv, the highest while radiation dose to radiologists at a department of radiation oncology was measured as 0.64 mSv, the lowest. Second, radiation dose proves to be in direct proportion to the number of X-ray treatment. Third, as for the radiation dose in X-ray treatments, radiologists in cardiac angiography room are exposed to the largest amount of radiation while radiologists in diagnostic radiology department are exposed to the smallest amount of radiation. Last, radiation dose at a cardiac angiography room is the largest and is followed by nuclear medicine, diagnostic radiology, and radiation oncology departments in order. According to ICRP, exposure less than 20mSv per year is highly recommended while radiation dose is allowed as long as it is ranged less than 50mSv per year or 100mSv within a 5-year period. Taking into account the results, radiation exposure does not do any harm to radiologists at any related departments in Korean hospitals because the dose per year is less than 1.60mSv.

  • PDF

A Study on Dose Reduction in Infant Skull Radiography (유아 두개골 방사선촬영에서 피폭선량 감쇄에 관한 연구)

  • Ahn, Byoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.387-392
    • /
    • 2017
  • When an infant has visited a hospital due to skull fracture, the rupture of a blood vessel, or skin wounds on the head resulted from an incident, accident, traffic accident, or disease, he/she becomes to undergo anterior/posterior and lateral skull imaging, which is a head test at the department of radiology. In the head test, if the adult skull imaging grid is applied to the imaging, the secondary radiation will be removed to enhance the contrast of the image. However, among the radiation exposure conditions, the tube voltage should be enhanced by 8~10 kVp leading to an increase in the patient exposure. The present study was conducted under assumption that if the same images can be obtained from infant skull imaging without using the skull imaging grid, the exposure dose will be reduced and the artifacts due to grid cut off can be prevented. The researcher measured the radiation dosage using a radiation meter and conducted the subjective evaluation (ROC, receiver operating characteristic) among medical image evaluation methods. Based on the results, when the images were taken without using the grid, the exposure dose was reduced by 0.019 mGy in the anterior/posterior imaging and by 0.02 mGy in the lateral imaging and the image evaluation score was higher by 4 points. In conclusion, if the images of the skulls of infants that visited the hospital are taken with out using the grid, the exposure dose can be reduced, the image artifacts due to grid cut off can be prevented, and the lifespan of the X-ray tube will be extended.