• Title/Summary/Keyword: 방사선피폭선량

Search Result 977, Processing Time 0.037 seconds

ANISN-MCNP 코드를 이용한 월성2호기 반응도제어기구 방사선흐름해석

  • 김용일;진영권;김교윤
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.269-274
    • /
    • 1996
  • 월성원자력발전소 2호기와 같은 CANDU 6형 원자로의 반응도제어기구 설치대에는 여러 반응도제어기구가 삽입되기때문에 원자로심으로부터의 방사선흐름현상으로 인한 방사선피폭이 예상될 수 있는 위치이다. 좁고 긴 반응도제어기구 도관에서의 방사선 흐름으로 인한 반응도제어기구 설치대에서의 방사선량을 예측하기 위해 몬테 칼로 MCNP 코드를 1차원 각분할법 코드인 ANISN과 연계하여 사용하였다. 월성원자력2호기의 상단차폐해석을 위한 ANISN 계산, 도관의 방사선흐름을 평가하기 위한 MCNP 계산, 그리고 반응도제어기구 설치대에서의 방사선량율 평가를 위한 MCNP 계산등 3단계 계산 기법의 적응이 시도되었다.

  • PDF

Quantification of Ceruloplasmin in Wale Rats Exposed to ${\gamma}$-radiation by Enzyme Linked Immunosorbent Assay (ELISA방법에 의한 방사선 피폭 후 흰쥐 혈액 내에서의 ceruloplasmin 정량)

  • Kim, In-Gyu;Park, Seon-Young;Kim, Kug-Chan;Lee, Kang-Suk
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.103-109
    • /
    • 1997
  • Adult male rats were exposed to a whole body with a single dose of 1.0, 2.0, 3.0, 5.0, and 7.0 Gy. The animals were sacrificed 48, 72, 96 and 216 hours following exposure. A competitive enzyme linked immunosorbent assay(ELISA) with antigen immobilized on the solid phase has been developed to measure ceruloplasmin in rat serum and complete dose response curves. Ceruloplasmin was purified from the plasma of turpentine treated male rats. Coating of ceruloplasmin had more effectiveness in 10 mM Tris-HCI, 150 mM sodium chloride, pH 7.4 than in 50 mM carbonate/bicarbonate buffer, pH 9.6. The coating range for ceruloplasmin was $70{\sim}140ng$/well. Levels of ceruloplasmin increased to maximum on the $72{\sim}96$ hours after irradiation. Slope of between response and dose was greatest value 96 hours following irradiation. Normal ceruloplasmin levels were not recorded 216 hours following exposure. In 0.1 Gy irradiated group, levels of ceruloplasmin also increased to maximum on the $72{\sim}96$ hours following irradiation. The concentration of this protein remained significantly different from control value, 196 hours after exposure. Ceruloplasmin was identified as one of the major acute phase protein following irradiation and further studies about gene expression and regulation would be necessary for radiation protection.

  • PDF

Patient Radiation Dose Values During Interventional Cardiology Examinations in University Hospital, Korea (심장혈관 조영술과 심장혈관 인터벤션의 환자 선량 평가)

  • Kim, Jung-Su;Lee, Joun-Hyuk;Jung, Hae-Kyoung;Kim, Jung-Min;Cho, Byung Ryul
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.27-33
    • /
    • 2016
  • The use of cardiac angiography (CA) and the interventional procedures is rapidly increasing due to the increase in modern adult diseases. Cardiovascular intervention (CI) is an examination method where radiation is applied to the same area for a long period, and thus may cause skin injury. In this study, we investigate the diagnostic reference level (DRL) of the cardiovascular intervention (CI) carried out by medical institutions and use it as a tool to reduce patient exposure dose. In this study, the DRL was set by acquiring information about the cumulative fluoroscopy time, cumulative fluoroscopy dose-area product (DAP), radiography DAP, cumulative DAP, air kerma, number of video clips, and the total number of images from the cardiac angiography and interventional procedures performed on 147 patients. The DAPs corresponding to the DRL of cardiac angiography(CA) and that of the interventional procedures were shown to be $44.4Gy{\cdot}cm2$ and $298.6Gy{\cdot}cm2$, respectively; the corresponding DRLs of fluoroscopy time were shown to be 191.5s and 1935.3s, respectively. A DRL is not a strict upper bound for radiation exposure. However, the process of setting, enacting, and reviewing the DRLs for the dose by medical institutions will contribute to a reduction in the unnecessary exposure dose of patients.

An Analysis of Carbon-14 Metabolism for Internal Dosimetry at CANDU Nuclear Power Plants (중수로 원전 종사자의 방사선량 평가를 위한 $^{14}C$ 인체대사모델 분석)

  • Kim, Hee-Geun;Lee, Hyung-Seok;Ha, Gak-Hyun
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.207-213
    • /
    • 2003
  • Carbon-14 is one of the major radionuclides released by CANDU Nuclear Power Plants(NPPs). It is almost always emitted as gas through the stack. From CANDU NPPs about 95% of all carbon-14 is released as carbon dioxide. Carbon-14 is a low energy beta emitter which, therefore, gives only a small skin dose from external radiation. As carbon dioxide Is physiologically rather inert gases for man's metabolism, the inhalation dose is probably less than 1 % of the ingestion dose. But this source of carbon-14, formed in a closed, nor-oxidative environment, was subsequently released into the workplace as an insoluble particulate when these systems were opened lip for re-tubing at CANDU NPPs. As a part of the improvement of dosimetry program at Wolsong Nuclear Power Plants, the carbon-14 metabolism based on references was investigated and studied to setup the internal dosimetry program due to inhalation of carbon-14.

Evaluation of entrance surface dose and image quality according to the installation of Bismuth shield in the case of endovascular treatment of cerebral aneurysm (뇌동맥류 코일 색전술 시 Bismuth 차폐체 설치에 따른 입사 표면 선량 평가 및 화질 평가)

  • Kim, Jae-Seok;Kim, Young-Kil;Choi, Jae-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.7
    • /
    • pp.779-785
    • /
    • 2019
  • By applying an ergonomically developed Bismuth shield to the endovascular treatment of cerebral aneurysm the radiation dose of the scalp and lens from the medical radiation exposure was reduced. The enrtance surface dose was analyzed by measuring the occipital parts, bilateral temporal parts, bilateral quadriceps, and nasal tip of the developed bismuth shield using a photostimulable fluorescence dosimeter before (Group A) before use (Group B). Signal to noise ratio (SNR) and contrast to noise ratio (CNR) analysis were used to evaluate the image quality when Bismuth shielding was used. The mean entrance surface dose of A group and B group was 26.92% lower than that of A group. The analysis of CNR and SNR was the same for both Roadmap and DSA. The use of Bismuth shielding is an alternative that can reduce the radiation impairment due to temporary hair loss and other stochastic effects that may occur after cerebrovascular intervention.

Radiation Dose during Fluoroscopy at the Organ from Extracorporeal Shock Wave Lithotripsy (체외충격파쇄석술에서 투시 시 주요 장기별 방사선 피폭선량)

  • Moon, Sung-Ho;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.5
    • /
    • pp.343-350
    • /
    • 2010
  • We measured the radiation exposure for 55 persons (male: 36, female: 19) who was diagnosed with kidney and ureter stones and received ESWL. The absorbed dose was measured at the organ which is expected to absorb relatively much radiation (kidney, bladder, liver). The radiation dose measurement voltage 80kVp, current of 5mA as a fixed model of the human body by using the Rando phantom with Radiophotoluminescent Glass Dosimeter. Absorbed dose was measured for two times (5 minute and 10 minute, each) and converted to effective dose. Mean number of treatment was 1.8 times (1~4) per patient was the mean time of radiation exposure533 seconds (248-2516). For the treatment of right renal stone, the effective dose of right kidney, left kidney, liver and bladder was 2.458mSv, 0.152mSv, 1.404 mSv and 0.019mSv, respectively. For the treatment of left renal stone, the effective dose of right kidney, left kidney, liver and bladder was 2.496mSv, 0.252mSv, 0.178 mSv, and 0.017mSv, respectively. For the treatment of distal ureter stone, the effective dose of right kidney, left kidney and bladder was 0.009mSv, 0.01mSv and 3.742mSv, respectively.

Convergence analysis of safety management for radiation workers and diagnostic radiation-generator devices of animal hospital in Korea (국내 동물병원의 진단용 방사선 발생장치 및 방사선 관계종사자 안전관리에 관한 융복합적 분석)

  • Kang, Kyoung-Mook;Suh, Tae-Young;Kim, Yong-Sang;Yun, Seon-Jong
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.4
    • /
    • pp.55-61
    • /
    • 2020
  • The various types of radiation-generator devices have been used in animal hospitals, and the safety for radiation workers is becoming important in Korea. This study investigated and analyzed the radiation safety management for diagnostic radiation-generator devices and radiation workers of animal hospital. The number of radiation-generator devices and radiation workers of animal hospital increased from 2,138 to 2,972 and from 2,644 and 5,733 for six years. The number of general X-ray, CT, C-arm, portable and dental X-ray in 2019 were 2,204, 58, 67, 770, and 14. The number of veterinarian, veterinary nurse, veterinary assistant, and others in 2019 were 4,236, 1,080, 404, and 13. The average exposure dose of radiation workers in 2018 were 0.21mSv in surface dose, 0.18mSv in depth doses. This study is expected to be the basic data for the safety management of radiation-generating devices and radiation workers in animal hospital.

A Study on the Reduction of Patient's Exposure Dose according to the Arrival Time of Contrast Media in Abdominal CT Scan using Bolus Tracking Technique (Bolus tracking 기법을 이용한 복부 CT 검사 시 조영제 도달시간에 따른 환자 피폭선량 감소에 관한 연구)

  • Lee, Seung yong;Han, Dong kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.93-100
    • /
    • 2021
  • The purpose of this study is to find out the factors that affect the patient's exposure dose during the abdominal CT scan using the bolus tracking technique, and reducing the radiation exposure to the patient during the abdominal CT scan using the bolus tracking technique by adjusting the delay time according to the corresponding factor. The experiment was divided into two parts, and the first experiment was conducted with 300 patients There were 188 males and 112 females, and their average age was 58±12.18(19~85). In the second experiment, 150 subjects (100 males and 50 females) who were undergoing their follow-up examination among the first experiment subjects, and the difference in dose before and after was compared by applying the delay time according to the influencing factor. As a result of the first experiment, there was a relationship between the arrival time of the contrast media and the heart rate, and it was found that the arrival time decreased as the heart rate increased for both men and women. As a result of the second experiment, the average dose of CTDIvol and DLP before/after applying the delay time according to the heart rate decreased 4.98 mGy and 5.33 mGy·cm in the male group, and 3.54 mGy and 3.88 mGy·cm in the female group. By applying proper delay time according to the patient's heart rate during abdominal CT scan with the bolus tracking technique, the radiation exposure dose of the patient can be reduced.

Analysis of Chromosomal Aberration Induced by Low Dose of Radiation (저선량방사선에 의한 염색체이상 빈도)

  • Yi, Chun-Ja;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.233-240
    • /
    • 1993
  • Chromosomal aberration analysis, as a basis for biological radiation dosimetry, was performed for radiation dose ranges below 150 cGy. The yield, ratio of lymphocytes with dicentric and/or ring chromosomes, was 0, 0, 0.4, 0.5, 0.6, 0.8, 1.8, 5.5, 8.0, and $18.5\%$ for 0,5, 10, 15, 20, 25, 50, 75, 100 and 150 cGy, respectively. The Qdr, ratio of dicentric and ring chromosomes in total lymphocytes, was 0, 0, 0.004, 0.005, 0.006, 0.009, 0.018, 0.055, 0.084 and 0.207, respectively. The Qdr, ratio of dicentric and ring chromosomes in lymphocytes with aberration, was 1.0 for the radiation doses up to 75 cGy and 1.05 and 1.11 for 100 and 150 cGy, respectively. From the results, it seems possible to estimate radiation dose from Ydr when the exposure is 25 cGy or more. All the 5 radiation workers studied, with exposure much less than 1 mSv per month, had chromosomal aberrations. And acentric fragment pairs, in addition to dicentric and ring chromosomes, showed good dose response relationship and so may be useful for biological dosimetry for low dose radiation.

  • PDF

Indoor Radon Levels and Effective Dose Estimation in Learning and Common Living Space of University (대학 내 학습공간과 공동 생활공간에 대한 실내 라돈 농도 측정과 유효선량 산출)

  • Kim, Jung-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.329-334
    • /
    • 2018
  • Radon which is natural component of air is a colorless and odorless radioactive gas. Radon exposure can also occur from some building materials if they are made from radon-containing substances by breathing. In this study, The radiation dose of radon concentration was detected at 8 buildings of the A university during 3-month from June. 2017 to August. 2017. We detected indoor radon exposure at 8 building of the university and estimated annual effective dose. The radon concentration of Hall G and Hall F of the A university represented 81 and $14Bq/m^3$ respectively and average indoor radon concentration represented $41.63Bq/m^3$. Average effective dose was estimated 0.40 mSv/y, maximum effective dose was 0.78 mSv/y and minimum effective dose was 0.13 mSv/y respectively. University is the place that students spend the almost whole time. We suggest ventilation and appropriate management of a building, which could reduce the natural radiation exposure by radon concentration.